ML20236S922

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 871006-09.Violation Noted: Monthly Sampling & Analysis of Vent Gaseous Tritium Effluent Required by 870625 Not Accomplished Until 870720
ML20236S922
Person / Time
Site: Callaway Ameren icon.png
Issue date: 11/19/1987
From: Shafer W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20236S905 List:
References
50-483-87-31, NUDOCS 8711300182
Download: ML20236S922 (1)


Text

. .

NOTICE OF VIOLA-'[,

Union Electric Company Docket No. 50-483 As a result of the inspection conducted on October 6-9, 1987, and in l accordance with 10 CFR Part 2, Appendix C - General Statement of Policy and  ;

Procedure for NRC Enforcement Actions (1985), the following violations were identified:

1. Technical Specification 4.11.2.1.2 requires, in part, monthly sampling and analysis of the unit vent gaseous tritium effluent.

Contrary to the above, the monthly sampling and analysis of the Unit vent gaseous tritium effluent required by June 25, 1987, was not accomplished until July 20, 1987.

This is a Severity Level IV violation (Supplement I).

2. Technical Specification 6.8.1.a requires adherence to the applicable procedures recommended in Appendix A to Regulatory Guide 1.33, i Revision 2, February 1978. Section 7.e.(1) of the aforementioned '

Appendix A requires radiation work permit (RWP) procedures.

Administrative Procedure No. APA-ZZ-01000, Callaway Plant Health Physics Program, Revision 1, Section 4.13.4.1 requires individuals to obey RWP respiratory protection requirements.

Contrary to the above, on October 8, 1987, during an inspection tour of the fuel building, an inspector observed that workers performing activities governed by the restrictions of RWP No. 87-386-2, Reconstitution of Fuel Assemblies, were removing items from the water without wearing respirators as required by the RWP.

This is a Severity Level IV violation (Supplement IV).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each violation: (1) corrective action ,

taken and the results achieved; (2) corrective action to be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Consideration may be given to extending your response time for good cause shown.

Dated ANembe l) ifs *7

[0$Sah W. D. Shafer, Chi 4f w

Emergency Preparedness and l Radiological Protection Branch B711300182 971119 3 PDR ADOCK 050 G