D Northem States Power Company 414 Nicollet Mall Minneapohs, Minnesota 55401 Telephone (612) 330-5500 October 21, 1985 Director Office of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT DOCKET NOS. 50-282 LICENSE NOS. DPR-42 50-306 UPR-60 Request for Exemption from the Requirements of 10 CFR Part 50. Appendix A.

GDC-4 Ref:

(a) NRC Generic Letter 84-04 dated February 1, 1984, " Safety Evaluation of Westinghouse Topical Reports Dealing with Elimination of Postulated Pipe Breaks in PWR Primary Main Loops (b) NSP letter dated October 24, 1984,

" Elimination of Large Reactor Coolant System Pipe Ruptures from Structural Design Basis" The purpose of this letter is to request, in accor-dance with the provisions of 10 CFR Part 50, Sec-tion 50.12, an exemption from the requirements of 10 CFR part 50, Appendix A, General Design Crite-rion 4 (GDC 4).

A check in the amount of $150.00 is attached as the review application fee for this exemption request in accordance with the require-ments of 10 CFR Part 170.

Exemption from the requirements of GDC-4 related to protection for dynamic effects associated with postulated pipe ruptures of primary coolant loop piping is sought in accordance with the guidance provided in Reference (a).

The basis of this re-quest is analytical work performed by the Westing-house Electric Corporation demonstrating the ex-tremely low probability of ruptures of this piping as noted in the attached reports:

@\\

WCAP-10640 Technical Bases for Eliminating Large Primary Loop Pipe Rupture as the Structural Design Bases for Prairie Island Unit 1 8511130315 051021 ADOCK0500g2 c,I,, p p C DR ad* iN(3F

Northem States Power Company Director:of NRR L0ctober 21.-1985 Page'2 WCAP-10928 Technicai Bases'for Eliminating Large Primary Loop Pipe Rupture as the-

-Structural Design Bases for Prairie Island

' Unit 2 WCAP-10930 Toughness criteria for Thermally Aged Cast Stainless Steel WCAP-10640 was previously submitted for the informa-tion of..the NRC-Staff with our letter dated October 24, 1984 (Reference b).

Copies of the proprietary version of.thisfreport (WCAP-10639)-were also pro-vided.

Proprietary versions of WCAP-10928 and WCAP-10930 will be provided under separate cover for NRC Staff review.

We :are aware that-this matter is currently-the subject of-NRC rule making.

A proposed rule related-to this issue was published in the Federal Register on July 1, 1985.

The purpose of making a submittal at this time,' prior to waiting for com-pletion of rulemaking, is to permit early staff review of alternate toughness criteria developed by Westinghouse for application to Unit 2.

If NRC action on the proposed rule is completed prior to completing review;of this request, our exemption request will.be with' drawn.

The attached

. reports will serve, however, the purpose of provi-ding the. supporting safety analyses required by the proposed rule.

Approval of this exemption request is required for the following reasons:

1. To close out Unresolved Safety Issue A-2 for Prairie-Island Units 1 and 2 2.

To permit removal, at a convenient time in the future, of pipe rupture restraints in-stalled in the reactor vessel shield wall of Units 1 and 2 to limit double ended pipe b'reak area (an early effort to close out Unresolved Safety Issue A-2 at Prairie Island).

We believe these devices have an overall negative effect on plant safety.

i

7 D

Northem States Power Company

. Director of'NRR October 21, 1985 Page.3 3.

To allow future removal, on a case-by-case

-basis-(or non-replacement when removed for inspection or: maintenance), of pipe whip and-Jet impingement devices on the reactor

-coolant loops where these. devices can be shown to have a negative effect on plant safety.

Please contact ~us-if you have any questions related to this request or if we can furnish additional iaformation related to this issue.

b Lw David Musolf Manager - Nuclear Supp rt Services c:

Regional Administrator-III, NRC Resident Inspector, NRC NRR Project Manager, NRC G Charnoff-Secretary of the Commission (Orig + 2 copies)

Attachments f

b.

cm Dir2ctor of NRR

~

21, 1985 October WCAP-10640 TECHNICAL BASES FOR ELIMINATING LARGE PRIMARY LOOP PIPE RUPTURE AS THE STRUCTURAL DESIGN BASIS FOR PRAIRIE ISLAND UNIT 1 September, 1984 S. A. Swamy R. A. Holmes Y. S. Lee H. F. Clark, Jr.

APPROVED:

\\&

n APPROVED:

J.'N.Chirigos,lanager E. R. Johnson, Manager Structural Materials Engineering Structural and Seismic Development APPROVED:8.S. 04'b i J. dcInerney, M&/ager Mechanical Equipment and Systems Licensing WESTINGHOUSE ELECTRIC CORPORATION Nuclear Energy Systems P.O. Box 355 Pittsburgh, Pennsylvania 15230 l

Q

\\ k t'

e..

FOREWORD This document contains Westinghouse Electric Corporation proprietary information and data which has been identified by brackets. Coding associated with the brackets set forth the basis on which the information is considered proprietary. These codes are listed with their meanings in WCAP-7211.

The proprietary information and data contained in this report were obtained at considerable Westinghouse expense and its release could seriously affect our competitive position. This infonnation is to be withheld from public disclosure in accordance with the Rules of Prac.tice, 10 CFR 2.790 and the information presented herein be safeguarded in accordance with 10 CFR 2.903.

Withholding of this information does not adversely affact the public interest.

This information has been provided for your internal use only and should not be released to persons or organizations outside the Directorate of Regulation and the ACRS without the express written approval of Westinghouse Electric Corporation. Should it become necessary to release this information to such persons as part of the review procedure, please contact Westinghouse Electric Corporation, which will make the necessary arrangements required to protect the Corporation's proprietary interests.

The proprietary information is deleted in the unclassified version of this report.

iii

fg7' L 0 LQ TABLE OF CONTENTS Section Title Pace

1.0 INTRODUCTION

1-1 1-1 1.1 Purpose 1 -1 1.2 Scope 1-1 1.3 Objectives 1.4 Background Information 1-2 2.0 OPERATION AND STABILITY OF THE PRIMARY SYSTEM 2-1 2.1 Stress Corrosion Cracking 2-1 2.2 Water Hammer 2-2 2.3 Low Cycle and High Cycle Fatigue 2-3 3.0 PIPE GEOMETRY AND LOADING 3-1 4.0 FRACTURE MECHANICS EVALUATION 4-1 4.1 Global Failure Mechanism 4-1 4.2 Local Failure Mechanism 4-2 4-3 4.3 Material Properties 4.4 Results of Crack Stability Evaluation 4-5 5-1 5.0 LEAK RATE PREDICTIONS 5-1 5.1 Introduction 5.2 General Considerations 5-1 5.3 Caiculation Method 5-1 5.4 Leak Rate Calculations 5-2 6-1 6.0 FATIGUE CRACK GROWTH ANALYSIS

7.0 ASSESSMENT

OF MARGINS 7-1 8-1

8.0 CONCLUSION

S 9-1 9.0 REFEREhCES APPEN0!X A- (

J c.e 4,3 a

v

LIST OF TABLES Table Title Pace 3-1 Prairie Island Primary Loop Data 3-3 6-1 Fatigue Crack Growth at [

] #

6-3 t

9 vit

.g I

M LIST OF FIGURES p

f.iggi Title

,P_ggi 3-1 Reactor Coolant Pipe 3-4 3-2 Schematic Diagram of Primary Loop Showing Weld Locations 3-5

- Prairie Island Unit 1 4-1

[

]

Stress Distribution 4-7 4-2 J v5 &a for SA376 TP316 Wrought Stainless Steel at 4-8 600*F 4-3 J vs &a for SA351 CF8M Cast Sthinless Steel at 600*F 4-9 4-4 J-&a Curves at Different Temperatures Aged Material 4-10

(

l

(7500 Hours at 400*C) 4-5

" Critical' Flaw Size Prediction 4-11 5-1 Analytical Predictions of Critical Flow Rates of 5-4 Steam-Water Mixtures i

5-2

(

l' # Pressure Ratio as a 5-5 Function of L/0 5-3 Idealized Pressure Drop Profile Through a 5-6 Postulated Crack 6-1 Typical Cross-Section of (

3.c.e 6-4 a

6-2 Reference Fatigue Crack Growth Curves for 6-5 g

j.c.e a

6-3 Reference Fatigue Crack Growth Law for (

6-6 J.c.e in a Water Environment at 600*F a

A-1 Pipe with a Through-Wall Crack in Bending A-2 ix

n

.u it i

1.0 INTRODUCTION

1.1 Purnose l

This report applies to the Prairie Island Unit 1 Reactor Coolant System (RCS) primary loop piping. It is intended to demonstrate that for the specific parameters of the Prairie Island plant, RCS primary loop pipe breaks need not be considered in the structural design basis. The approach taken has been accepted by the Nuclear Regulatory Commission (NRC) (Reference 1).

1.2 igggt The structural design basis for the RCS primary loop requires that pipe breaks be postulated. In addition, protective measures for the dynamic effects associated with RCS prim 4ry loop pipe breaks have been incorporated in the Prairie Island Unit 1 plant design. However, Westinghouse has demonstrated on a generic basis that RCS primary loop pipe breaks are highly unlikely and should not be tacluded in the structural design basis of Westinghouse plants (see Reference 2).

In order to demonstrate this applicability of the generic evaluations'to the Prairie Island plant, Westinghouse has performed a f racture mechanics evaluation, a determination of leak rates from a through-wall crack, a fatigue crack growth evaluation, and an assessment of margins.

1.3 Obiectives In order to validate tt.e elimination of RCS primary loop pipe breaks for the Prairie Island plant, the following objectives must be achieved:

a.

Demonstrate that margin exists between the critical crack size and a postulated crack which yields a detectable leak rate.

b.

Demonstrate that there is suf ficient margin between the leakage through a postulated crack'and the leak detection capability of the Prairie Island plant.

1-1

v f

c.

Demonstrate that fatigue crack growth is negligible.

1.a Backoround Information Westinghouse has performed considerable testing and analysis to demonstrate that RCS primary loop pipe breaks can be eliminated from the structural design basis of all Westinghouse plants. The concept of eliminating pipe breaks in the RCS primary loop was first presented to the NRC in 1978 in WCAP-9283 (Reference 3). That Tor kal Report employed a deterministic fracture mechanics evaluation and a probabilistic analysis to support the elimination

~

of RCS primary loop pipe breaks. That approach was then used as a means of addressing Generic Issue A-2 and Asymmetric LOCA Loads.

Westinghouse performed additional testing and analysis to justify the elimination of RCS primary loop pipe breaks. This material was provided to the NRC along with Letter Report NS-EPR-2519 (Reference 4).

The NRC funded research through Lawrence Livermore National Laboratory (LLNL) to address this same issue using a probabilistic approach. As part of the LLNL research effort Westinghouse perfortned extensive evaluations of specific plant loads, material properties, transients, and system geometries to demonstrate that the analysis and testing previously performed by Westingnouse and the research performed by LLNL applied to all Westinghouse plants including Prairie Island (References 5 and 6). The results from the LLNL i

study were released at a Narch 28, 1983 ACRS Subconsnittee meeting. These studies which are applicable to all Westinghouse plants east of the Rocky Mountains determined the mean probability of a direct LOCA (RCS primary loop

-10 pipe break) to be 10 per reactor year and the mean probability of an

~

indirect LOCA to be 10 per reactor year. Thus, the results previously obtained by Westinghouse (Reference 3) were confirmed by an independent NRC research study.

Based on the studies by Westinghouse, LLNL, the ACRS, and the AIF, the NRC completed a safety review of the Westinghouse reports submitted to address asymmetric blowdown loads that result f rom a numoer of discrete break

. locations on the PWR primary systems. The NRC Staff evaluation (Reference 1) 1-2

s 5

1-J concludes that an acceptable technical basis has been provided so that asymmetric blowdown loads need not be considered for those plants that can demonstrate the applicability of the modeling and conclusions contained in the Westinghouse response or can provide an equivalent fracture mechanics demonstration of the primary coolant loop integrity.

This report provides a fracture mechanics demonstration of primary loop integrity for the Prairie Island plant consistent with the NRC position for not considering asyneetric blowdown.

1-3 i-

f C

10 OPERATION AND STABILITY OF THE REACTOR COOLANT SYSTEM The Westinghouse reactor coolant system primary loop has an operating history which demonstrates the inherent stability characteristics of the design. This includes a low' susceptibility to cracking failure f rom the effects of corrosion (e.g., intergranular stress corrosion cracking), water hammer, or fatigue (low and high cycle). This operating history totals over 400 reactor-years, including five plants each having 15 years of operation and 15 other plants each with over 10 years of operation.

2.1 Stress corrosion Crackina For the Westinghouse plants, there is no history of cracking failure in the reactor coolant system loop piping. For stress corrosion cracking (SCC) to occur in piping, the following three conditions must exist simultaneously:

. high tensile stresses, a susceptible material, and a corrosive environment (Reference 7).

Since some residual stresses and some degree of material susceptibility exist in any stainless steel ciping, the potential for stress corrosion is minimized by proper material selection immune to SCC as well as preventing the occurrence of a corrosive environment. The material specifications consider compatibility with the system's operating environment (both internal and external) as well as other materials in the system, applicable ASME Code rules, fracture toughness, welding, fabrication, and processing.

The environments known to increase the susceptibilty of austenitic stainless steel to stress corrosion are (Reference 7): oxygen, fluorides, chlorides, hydroxides, hydrogen peroxide, and reduced forms of sulfur (e.g., sulfides, sulfites, and thionates). Strict pipe cleaning standards prior to operation and careful control of water chemistry during plant operation are used to prevent the occurrence of a corrosive environment.

Prior to being put into service, the piping is cleaned internally and externally. During flushes and preoperational testing, water chemistry is controlled in accordance with written specifications. External cleaning for Class 1 stainless steel piping includes patch tests to monitor and control chloride and fluoride levels. For 2-1

+

Q

O Y

preoperational flushes. influent water chemistry is controlled. Requirements on chlorides, fluorides, conductivity, and pH are included in the acceptance criteria for the piping.

During plant operation, the reactor coolant water chemistry is monitored and maintained within very specific limits. Contaminant concentrations are kept below the thresholds known to be conducive to stress corrosion cracking with the major water chemistry control standards being included in the plant operating procedures as a condition for plant operation. For example, during j

normal power operation, oxygen concentration in the RCS is expected to be less than 0.005 ppm by controlling charging flow chemistry and maintaining hydrogen in the reactor coolant at specified concentrations. Halogen concentrations are also stringently controlled by maintaining concentrations of chlorides and fluorides within the specified limits. This is assured by controlling charging flow chemistry and specifying proper wetted surface materials.

l 2.2 Water Manner Overall, there is a low potential for water hanumer in the RCS since it is designed and operated to preclude the voiding condition in normally filled lines. The reactor coolant system, including piping and primary components, is designed for normal, upset, emergency, and faulted condition transients.

The design requirements are conservative relative to both the number of transients and their severity. Relief valve actuation and the associated i

hydraulic transients following valve opening are considered in the system design. Other valve and pump actuations are relatively slow transients with no significant effect on the system dynamic loads. To ensure dynamic system stability, reactor coolant parameters are stringently controlled. Temperature l

during normal operation is maintained within a narrow range by control rod position; pressure is controlled by pressurizer heaters and pressuriter spray also within a narrow range for steady-state conditions. The flow characteristics of the system remain constant during a fuel cycle because the only governing parameters, namely system resistance and the reactor coolant pump characteristics are controlled in the design process. Additionally, Westinghouse has instrumented typical reactor coolant systems to verify the flow and vibration characteristics of the system. Preoperational testing and i

2-2

.. ~...

_j

f

-O operating experience have verified the Westinghouse approach. The operating transients of the RCS primary piping are such that no significant water hammer can occur.

2.3 Low cvele and High Cvele Fatique Low cycle fatigue considerations are accounted for in the design of the piping system through the fatigue usage factor evaluation to show compliance with the rules of Section III of the ASME Code. A further evaluation of the low cycle f atigue loadings was carried out as part of this study in the form of a fatigue crack growth analysis, as discussed in Section 6.

4 High cycle fatigue loads in the system would result primarily from pump vibrations. These are minimized by restrictions placed on shaft vibrations during hot functional testing and operation. During operation, an alarm signals the exceedance of the vibration limits. Field measurements have been made on a number of plants during hot functional testing, including plants similar to Prairie Island. Stresses in the elbow below the reactor coolant pump have been found to be very small, between 2 and 3 ksi at the highest.

l These stresses are well below the fatigue endurance limit for the material and would'also result in an applied stress intensity factor below the threshold for f atigue crack growth.

1 2-3

- i

v i

3.0 PIPE GEOMETRY aNO LOADING A segment of the primary coolant hot leg pipe shown below to be limiting is sketched in Figure 3-1.

This segment is postulated to contain a circumf erential through-wall flaw. The inside diameter and wall thickness of the pipe are 2g.2 and 2.69 inches, respectively. The pipe is subjected to a normal operating pressure of 2235 psi. Figure 3-2 identifies the loop weld locations. The material properties and the loads at these locations resulting from deadweight, thermal expansion, and Safe Shutdown Earthquake are indicated in Table 3-1.

As seen from this table, the junction of the hot leg and the reactor vessel outlet nozzle is the worst location for crack stability analysis based on the highest stress due to combined pressure, dead weight, thermal expansion, and SSE (Safe Shutdown Earthquake) loading. At this location, the axial load (F,) and the bending moment (M ) are [

b

]

(including axial force due to pressure) and [

]"'"d,respectively. This location will be referred to as the critical location. The loads of Table 3-1 are calculated as follows:

The axial force F and transverse bending moments, M and M, are chosen g

for each static load (pressure, deadweight, and thermal) based on elastic-static analyses for each of these load cases. These pipe load components are combined algebraically to define the equivalent pipe static loads F, M, and M Based on elastic SSE response spectra analyses, 3

zs.

are obtained. The maximum amplified pipe seismic loads F '

yd' Zd d

pipe loads are obtained by combining the static and dynamic load components as follows:

4

+

F F, =

F, d

M

  • M Mb" y

z where:

y" ys yd "z "

Zs Zd 3-1 I

f y

j The normal operating loads (i.e., algebric sum of pressure, deadweight, and 100 percent power thermal expansion loading) at the critical location, i.e.,

the junction of the hot leg and the reactor vessel outlet nozzle, are as follows:

F=(

]a.c.e (including internal pressure) a

,,g 3.c.e The calculated and allowable stresses for ASME III NS-3600 equation g (faultec 1.e., pressure, deadweight, and SSE) and equation 12 (normal operating thermal stress) at the critical location are as follows:

Calculated Allowable Ratio of Equation Stress Stress Calculated /

Number fksi)

(ksi)

A110waole 9p

4. c.'s a,c.e 50.1 12 50.1 6

3-2

q n.

t TA8tf 3-1 PRAIRIE _ ISL Alle PtiftARY LOOP SATA Faulted toadsa a.c.e

?

/

o s

t & A

\\

\\

b,.-

i. mY

.a 8

Includes icternal pressure b Critical Location Note: The piping material for Pralrle Island tinit 1 is AS194 3M-TP316; for all fittings, the material is SA351-CFelt. Per the ASftE Code. Sect ton Ill. Sivision 1. the yleid strengths are the same for the two materials; however, the ultimate stress for the SA351-CF0ft is almost 5 ksi less. Consequently, the properties of SA351-CF8pl are given tr. this table.and will be used in the analyses set forth in this report even though there is no SA351-CFast material at the critical location.

4 w

f F

i

.ar 'T' ~,.

! k

.I 6

v 1. _ '

R t.

5a

.a I

l l

l 1

I

.1-1 l

l I

9 C

l C

l J

i L

__l

=

i 1

=

A l

I e

=

l 1

1 I

1 I

~

l I

N a

t V

34

,a 1

1

?

REACTOR PEESSURE VESSEL 3

HOT LEG COLD LEG 1

..,g REACTOR COOLANT PUMP CROSSOVER LEG a

G* B" i

A

.O e

HOT LEG Temperature: 599'F; Pressure:

2235 psi

,;/

CdOSSOVER LEG

)

Temperature: 536*F; Fressure: 2190 psi-COLD LEG Temperature: 536*F; Pressure: 2290 psi t

Figure 3-2 Schematic Diagram of Primary Loop Showing Weld Locations -

Prairie Island Unit 1 3-5

1 V

4.0 FRACTURE MECHANICS EVALUATION 4.1 Global Failure Mechanism Determination of the conditions which lead to failure in stainless steel must be done with plastic fracture methodology because of the large amount of deformation accompanying fracture. A conservative method for predictir.g the failure of ductile material is the [

]

This methodology has been shown to be applicable to ductile piping through a large number of experiments and will be used here to predict the critical flaw size in the primary coolant piping. The failure criterion has been obtained by requiring [

]a,c.e (Figure 4-1) when loads are applied. The detailed development is provided in Appendix A for a through-wall circumferential flaw in a pipe with internal pressure, axial force, and imposed bending moments. The [

]C for such a pipe is given by:

a,c.e g

)

where:

"a c.e

~

R 4-1 m-

y 1

a,c.e l

The analytical model described above a:curately accounts for the piping

, internal pressure as well as imposed axial force as they affect [

}"'

Good agreement was found between the analytical predictions and the experimental results (Reference 8).

4.2 Local Failure Mechanism The local mechanism of failure is primarily dominated by the crack tip behavior in terms of crack-tig blunting, initiation, extension and finally crack instability. Depending on the material properties and geometry of the pipe, flaw size, shape and loading, the local failure mechanisms may or may not govern the ultimate f ailure.

The stability will be assumed if the crack does not initiate at all.

It has been accepted that the initiation toughness measured in terms of J from a g

J-integral resistance curve is a material parameter defining the crack

-initiation.

If, for a given load, the calculated J-integral value is shown to be less than the J, of the material, thee the crack will not initiate.

If g

the initiation criterion 's not met, one ein calculate the tearing modulus as defined by the following relation:

7

. il

.JL.

app da 2

,f 4-2

r, where:

T,p, = applied tearing modulus E = modulus of elasticity f=[

]"'C # (flow stress) o a = crack length a

(

3.c.e In summary, the local crack stability will be established by the two-step criteria:

J<J gc t

T,,, < T,,

' ' J ?, J gc In this analysis, a hypothesized circumferential through-wall [

J c.e flaw is taken as a reference flaw and is used as a basis for a

evaluation.

4.3 Material Procerties The primary loop piping material for Prairie Island Unit 1 is ASTM a

376-TP316, a wrought product form. The material for the primary loop fittings is SA351-CFBM, a cast product form. Welds exist as indicated in Figure 3-2.

The minimum yield stress for these materials, namely SA376-TP316 and SA351-CF8M, given in the ASME Code Section III, Division 1 are the same.

The ultimate stress for the cast product form is somewhat less and is used in this report.

l The tensile and flow properties of the critical location, the hot leg and the reactor vessel nozzle junction, are given in Table 3-1.

a l

The ASTM designation is the information of record and predates the SA designation.

J 4-3

v t

The pre-service fracture toughness of both the wrought and cast materials in terms'of J have been found to be very high at 600*F. Typical results are given in Figures 4-2 and 4-3 taken from References 9.

J is observed to be 2

gg well over 2000 in-lbs/in. However, cast stainless steels are subject to thermal aging during service. This thermal aging causes an elevation in the yield strength of the material and a degradation of the fracture toughness, the degree of degradation being proportional to the level of ferrite in the material. To determine the effects of thermal aging on piping integrity, a detailed study was carried out in Refe ence 10. In this report, fracture toughness results were presented for a material representative of [

]C

Toughness results wre provided for the material in the fully aged condition and these properties are also presented in Figure 4-4 of this report for information. The J value gg for this material at operat*ing temperature was approximately [

]*'C and the maximum value of J obtained in the tests was in excess of [

]a,c.e The tests of this material were conducted on small specimens and therefore rather short crack extensions.

(maximum extension 4.3 nun) so it is expected that higher J values would be sustained for larger specimens. [

ay.c.e Therefore, per Ref.10 it may be concluded that the degree of thermal aging expected by end-of-life is less than that which was produced in [

j

)."'Cd Hence, the Jge. values for Prairie Island Unit 1 at end-of-life would be expected to be considerably higher than those reported for [

]**C in Figure 4-4 (also see Reference 11). In addition, the tearing modulus for the Prairie Island Unit 1 materials would be greater than a

g y.c.e Available data on aged stainless steel welds (Reference 10 and 11) indicate

'the J values f r the worst case welds are of the same order as the aged k

material, but the slope of the J-R curve is steeper, and higher J-values have 2

been obtained from fracture tests (in excess of 3000 in-lbs/in ).

The j

4-4 i

b applied value of the J-integral for a flaw in the weld regions will be lower than that in the base metal because the yield stress for the weld materials is much higher at temperature. Therefore, weld regions are less limiting than the cast material.

In the fracture mechanics analyses that follow, the fracture toughness properties of [

]' ' # # discussed above will be used as'the criterion against which the applied fracture toughness values will be compared.

4.4 Results of Crack Stability Evaluation Figure 4-5 shows a plot of the [

3,c.e as a function of a

through-wall circumferential flaw length in the [

]**# of the main coolant piping. This [

]"'## was calculated for Prairie Island from data for a pressurized pipe at 2235 psi with an axial force of [

]"'C #, operating at 599'F with [

]"'C

properties. The maximum applied bending moment of (

J.c.e in-kips can a

be plotted on this figure, and used to determine a critical flaw length, which is shown to be [

J,c.e inches.

a In Table 3-1, the outer surf ace axial stress (e,) at the critical location is seen to be (

l c.e Stresses due to the internal pressure of a

2235 psi are as follows (see Reference 12):

11.1 ksi g (circumferential stress):

o e radial stress: 0 r

The von Mises effective stress, e,pp, (see Reference 13) is given by e,ff =

(8, - e )

  • I'c - 'r) + I'a - 'c) r and is [

J,c.e a

4-5

v

,1 Thus the effective stress is less than the yield stress and by the Von Mises plasticity theory yielding does not occur. Hence, linear elastic fracture mechanics is applicable for. analyzing the pipe with hypothesized flaws. The analytical method used for the local stability evaluation is sununarized below.

i The stress intensity factors corresponding to tension and bending are expressed, respectively, by (see Reference 14)

K

=a F

(a) t F

I*I Kb=e b

~

where F (a) and F (a) are stress intensity calibration factors g

b corresponding to tension and bending, respectively, a is the half-crack angle, o is the remote uniform tensile stress, and e 8 * ' "'" I' g

b fiber stress due to pure bending. Data for F (s) and F I*I ""' I1"'"

t b

in Reference 15. The effect of the yielding near the crack tip can be.

incorporated by Irwin's plastic zone correction method (see Reference 15) in which the crack length, 4, in these formulas is replaced by the effective crack length, a,ff, defined by a,ff = a + 21r ey for plane stress plastic corrections, where e is the yield strength of y

the material and K is the total stress intensity due to combined tensile and bending loads. Finally, the J -value is determined b'y the relation Jg=

7 2

K /E, where E = Young's Modulus (25.3 x 106,34),

J was calculated for a through-wall flaw (

]*'C inches long (the 2

reference flaw) and found to be [

]****' in-lbs/in. The flaw was a

increased by 50% (

J.c.e and J was found to be [

]***.

Both of these values are less than J;g for the worst case [

3 c.e cast material described above. Thus crack initiation a

is not expected to occur in the Prairie Island piping even for circumferential through-wall flaws up to [

]8'C inches long under the loading conditions given.

4-6

o, a,c.e

,;;i;:llllli111,,,

2.

~ wum A...

D a

a,c.a FIGURE 4-1

[

3 STRESS DISTRIBUTION 4-7 i

=

7 a c.e I

(-

t Figure 4-2 J vs.a for 5A376 TP316'Wrougn: Stainless Steel at 600*F 4-3

r a,c.e i

i i

i t

t L

Figure 4-3 J vs la for SA351-CF8M Cast Stainless Steel at 600'F 4-9

r-

.i.

u..

FIGURE 4-4 J-t.a Curves at Different Temceratures for Aged Material (

Ja.c.s (7500 Hours at 400*C) 4-10

=

a,c.e L

l I

v i

FLAW GEOMETRY OD 34.58 in,

=

2.69 in, t

=

2235 psi p

=

i l

L Figure 4-5

" Critical" Flaw Size Prediction 4-11

v 1

5.0 LEAK RATE PREDICTIONS 5.1 Introduction Fracture mechanics analysis has shown that postulated through-wall cracks in the primary loop would remain stable and not cause a gross failure of this component.

If such a through-wall crack did exist, it would be desirable to detect the leakage.such that the plant could be brought to a safe shutdown condition. The purpose of this section is to discuss the method which will be used to predict the flow through such a postulated crack and present the leak rate calculation results for through-wall circumferential cracks.

5.2 General Considerations The flow of hot pressurized water through an opening to a lower back pressure causes flashing which can result in choking. For long channels where the ratio of the channel length, L, to hydraulic diameter, D '

3 H

greater than [

]a.c.e. both [

]a,,e must be considered.

In this situation the flow can be described as being single-phase through the channel until the local pressure equals the saturation pressure of the fluid. At this point, the flow begins to flash and choking occurs.

Pressure losses due to momentum changes will dominate for_(

J.c.e a

However, for large L/0 values, friction pressure drop will become important H

and must be considered along with the momentum losses due to flashing.

1.

5.3 Calculation Method The basic method used in the leak rate calculations is the method developed by L

of the choked exit plane, as j.c.e a

The flow rate through a crack was calculated in the following manner. Figure 5-1 from Reference 16 was used to estimate the critical pressure, Pc, for the primary loop enthalpy condition and an assumed flow. Once Pc was found for a

]**

given mass flow, the [

5-1 l

l

T 3

was found from Figure 5-2 taken from Reference 16.

For all cases considered, since [

]a.c.e Therefore, this method will yield the two-phase pressure drop due to momentum effects as illustrated in Figure 5-3.

Now using the assumed flow rate 6, the frictional pressure drop can be calculated using a,c.e

&Pg=

(5-1) where the friction factor f is determined using the [

']"'"

The crack relative roughness, c, was obtained from fatigue crack data on stainless steel samples. The relative roughness value u, sed in these

^ d'RMS.

calculations was [

]

The frictional pressure drop using Equation 5-1 is then calculated for the assumed flow and added to the [

J.c.e to obtain the total pressure drop f rom the primary system a

to the atmosphere. That is, for the primary loop Absolute Pressure - 14.7 = [

]****'

(5-2) for a given assumed flow G.

If the right-hand side of Equation 5-2 does not agree with the pressure difference between the primary loop and the atmosphere, then the procedure is repeated until Equation 5-2 is satisfied to within an ace.:ptable tolerance and this results in the flow 'velue through the crack. This calculational procedure has been recommended by [

]" d for this type of [

]" calculation.

5.4 Leak Rate calculations Leak rate estimates were performed by applying the normal operating bending moment of (

.]8'C in addition to the normal operating axial a

force of [

J.c.e These loads were applied to the hot les pipe containing the postulated reference [

]a c.e through-wall 5-2

(

?

flaw and the crack opening area was estimated using the method of Reference 14.

The leak rate was calculated using the two-phase flow formulation described above. The computed leak rate was [

]a.c.e In order to determine the sensitivity of leak rate to flaw size, a through-wall flaw [

]a.c.e in length was postulated. The calculated leak rate was [

3.c.e a

The Prairie Island plant has an RCS pressure boundary leak detection system

' which is consistent with the guidelines of Regulatory Guide 1.45 for detecting leakage of 1 gpm in one hour. Thus, for the [

]

inch flaw, a factor in excess of 80 exists between the calculated leak rate and the criteria of Regulatory Guide 1.45.

Relative to the [

], a factor of over 23 exists.

5-3

s

~

- a,c.e

,=

t=I i

U h

N<3 2

STAGNATION ENTHALPY (10 Stu/lb) 1 Figure 5-1 Analytical Predictions of Critical Flow Rates of Steam-Water Mixtures 54

~

m m,

=. - - -

a,c.e

~ e 48 9

m w

E 5

E a,

Y

- u2eu LENGTM/ DIAMETER RATIO (L/D) a,c.e Figure 5-2 [

j Pressure Ratio as a Function of L/0 5-5

-w e

-,e.*

--e.,-,,,,7

-,r--

y-

,,,y,,,---v.-

,-,v-v,--,

s s

l i

1

_ a,c.e a,c.e

/

7 t

=

1 Figure 5-3 Idealized Pressure Drop Profile Through a Postulated Crack 5-6

4 6.0 FATIGUE CRACK GROWTH ANALYSIS To determine the sensitivity of the primary coolant system to the presence of small cracks, a fatigue crack growth analysis was carried out for the [

]a,c.e region of a typical system (see Location

(- ]

of Figure 3-2).

This region was selected because it is typically one of the highest stressed cross sections, and crack growth calculated here will be typical of that in the entire primary loop.

A(

]"'C # of a plant typical in geometry and operational characteristics to any Westinghouse PWR System. [

y.c.e a

All normal, upset, and test conditions were considered and circumferentially oriented surface flaws were postulated in the region, assuming the flaw was located in three different locations, as shown in Figure 6-1.

Specifically, these were:

"'C

Cross Section A:

Cross Section B:

Cross Section C:

Fatigue crack growth rate laws were used [

]C

The law for stainless steel was derived from Reference 18, with a very conservative correction for the R ratio, which is the ratio of minimum to maximum stress during a transient.

For stainless steel, the fatigue crack growth formula is:

4.48 ff=(5.4x10

) K,fp inches / cycle 6-1 y-y v-

e where K,,, = K,, (1-R)0.5

" " " min #" max

[*

j.c.e a

a c.e

[

]

where: [

] a c.e The calculated fatigue crack growth for semi-elliptic surface flaws of circumferential orientation and various depths is sunmarized in Table 6-1, and shows that the crack growth is very small, regardless [

a3.c.e 6-2

E 1

8 TABLE 6-1 Ft.TIGUE CRACK GROWTH AT [

3a,c.e (40 YEARS)

FINAL FLAW (in)

~a,c.e INITIAL FLAW (IN)

[

la.c.e

[

ja.c.e 0.292 0.31097 0.30107 0.30698 0.300 0.31949 0.30953 0.31626 0.375 0.39940 0.38948 0.40763 0.425 0.45271 0.4435 0.47421 i

l l

i-1 l

i l

6-3 i

l

t*+

m s

w--,

,.,w-.4 w,

-r--,

-.._g

1 e

-e 1

}a,c.e i

Figure 6-1 Typical Cross-Section of [

ja.c,e 6-4

E

- a.c. e f

50

>U

.saw3 Os 2

- E Es 4-

- a><sz

' h Ceouu4eu i

)

Figure 6-2 Reference Fatigue Crack Growth Curves for [

i Ja.c.e 6-5

b East 2 4

I

- a.c. e t

7 4

J J

i j

i:'

i.-

1=

i-J J

i a

7

.?

=

4 :

Figure 6-3 Reference Fatigue Crack Growth Law for[

Ja.c.e in a Water Environment at 6000F 4-t Y

a 6-6 4-

?

4 v

e---

w

-3

,w.-,

.avc.-

r

+,,w4-m,--.-*,,..

w een,.-

.--,we-e-,-,,

,.+,,-ww

-vm--

.e-

o o

7.0 ASSESSMENT

OF MARGINJ For a through-wall circumf erential flaw (

] C d for the faulted loading conditions. A f actor of of (

about 2 exists between this value and the critical Jgg

]

for fully aged cast material of chemistry worst than that existing in the Prairie Island cast fittings. Thus initiation would not be

. anticipated for this s tuat on. The test results for the worst case material i

i show J-values to near [

]C

Increasing the hypothesized flaw by 50% to (

]' ' C d increased the applied J to [

for the fully aged lC # which is still less than J7g material.

As shown in Section 3.0, a margin of a factor of not less than 4 exists betwaen calculated and ASME Code allowable faulted condition and thermal stresses.

In Section 4,4, the " critical" flaw size using (

]C metnod is calculated to be [

]a,c.e inches. Based on the above, the " critical" flaw itze will, of course, exceed [

]C

In Section 5.0, it is shown that a flaw of (

J.c.e would yield a a

leak rate in excess of [

l.c.e while for a (

]C inch flaw, the a

leak rate is over [

).a,c.e Thus, there is a margin of at least 4 between the flaw size that gives a leak rate well exceeding the criterion of Regulatory Guide 1.45 and the " critical" flaw size of (

J.c.e a

In summary, relative to

1. M Prairie Island Unit 1 is enveloped by the J values employed in testing a.

of fully aged material.

7-1

b.

Margins at the critical location of at least 4 on faulted conditions and thermal stresses exist relative to ASME Code allowable values.

2.

Flaw Size a.

A margin of at least 4 exists between the ' critical" flaw and the flaw yielding a leak rate of (

]a c.e b.

If (

]"'C d is used as the basis for " critical" flaw size, the margin' for global stability compared to the reference flaw would be near 5.

c.

A margin of at least 50% exists between the reference flaw size [

]"'C# and the established minimum " critical" flaw size. Flaw initiation is shown not to occur for either case, J<J gg for flaws of size of at least (

J.c.e inches.

a 3.

Leak Rate A margin in excess of 80 exists for the reference flaw (

)C # between calculated leak rates and the criteria of Regulatory Guide 1.45.

i 7-2

8.0 CONCLUSION

S This feport justifies the elimination of RCS primary loop pipe breaks for the Prairie Island Unit 1 plant as follows:

a.

Stress corrosion cracking is precluded by use of f racture resistant materials in the p'ipini' system and controls on reactor coolant chemistry, temperature,- pressure, and flow during normal operation, b.

Water htmmer should not occur in the RCS piping because of system design, testing, and operational considerations.

1' x

s.

c.

The e'ffects of low and high cycle fatigue on the integrity of the primary piping are negligibie.

.A d.

Adequate margin exists between the leak rate of the reference flaw and the criteria of Reg. Guide 1.45.

e.

Ample margin exists between the reference flaw chosen for leak detectability an'd the " critical" flaw.

f.

Ample margin exists in the material properties used to demonstrate end-of-life (relative to aging) stability of the reference flaw.

The reference flaw will be stable throughout reactor life because of the ample margins in d, e and f above and will leak at a detectable rate which will assure a safe plant shutdown, t

Based on the above, it is concluded that RCS primary loop pipe breaks should

~

not be considered in,the structural design basis of the Prairie Island Unit 1 plant.

s.

4 b

4 8-1 4

=

9.0 REFERENCES

j 1.

USNRC Generic letter 84-04,

Subject:

" Safety Evaluation of Westinghouse Topical Reports Dealing with Elimination of Postulated Pipe Breaks in PWR Primary Main Loops", February 1,1984.

2.

Letter from Westinghouse (E. P. Rahe) to NRC (R. H. Vollmer),

NS-EPR-2768, dated May 11, 1983.

3.

WCAP-9283, "The Integrity of Primary Piping Systems of Westinghouse l

Nuclear Power Plants During Postalated Seismic Events," March,1978.

4.

Letter Report NS-EPR-2519 Westinghouse'(E. P. Rahe) to NRC (O. G.

Eisenhut), Westinghouse Proprietary Class 2, November 10, 1981.

5.

Letter from Westinghouse (E..P. Rahe) to NRC (W. V. Johnston) dated April 25, 1983.

6.

Letter from Westinghouse (E. P. Rahe) to NRC (W. V. Johnston) dated July 25, 1983.

7.

NCREG-0691, " Investigation and Evaluation of Cracking Incidents in Piping in Pressurized Water Reactors", USNRC, September 1980.

1 8.

Kanninen, M.

F., et. al., " Mechanical Fracture Predictions for Sensitized Stainless Steel Piping with Circumferential Cracks". EPRI NP-192, September 1976.

9.

Landes, J.

D., et. al., Fracture Toughness of 316 Stainless Steel Piping Material at 600*F, Westinghouse R&D Report 79-703-PIPRE-R1, May 17,1979 (Westinghouse Proprietary Class 2).

9-1

  • O
10. WCAP-10456, "The Ef fects of Thermal Aging on the Structural Integrity of Cast Stainless Steel Piping For M NSSS," M Proprietary. Class 2, November.

1983.

11. Slama, G., Petrequin, P., Masson, S.

H., and Mager, T. R., "Effect of Aging on Mechanical Properties of Austenitic Stainlest Steel Casting and Welds", presented at SMiRT 7 Post Conference Seminar 6 - Assuring Structural Integrity of Steel Reactor Pressure Boundary Components, August 29/30, 1983, Monterey, CA.

12. Ourelli, A.

J., etI a1., Introduction to the Theoretical and Exoerimental' Analysis of Stress and Strain, McGraw Hill Book Company, New York, (1958), pp 233-236.

13. Johnson, W. and Mellor, P.

B.,

Enaineerina Plasticity, Van Nostrand Relmhold Company, New York, (1973), pp 83-86.

i

14. Tada, H.,

"The Effects of Shell Corrections on Stress Intensity Factors and the Crack Opening Area of Circumferential and a Longitudinal Through-Crack in a Pipe," Section II-1, NUREG/CR-3464. September 1983.

15. -Irwin, G.

R., " Plastic Zone Near a Crack and Fracture Toughness," Proc.

7th Sagamore Conference, P. IV-63 (1960).

.)

16.

[

i.

j.c.e a

17. (

a3.c.e 9-2 s 3

o o

18. Bamford, W.

H., " Fatigue Crack Growth of Stainless Steel Piping in a Pressurized Water Reactor Environment," Trans.. ASME Journal of Pressure versel. Technology, Vol. 101. Feb. 1979.

19. [

3a c.e

20. (

3a,c.e d

e b

9-3

,-.,,.,r--,-,--.,.-.m~

< a

-, ~. -

r i

e APPENCIX A a.c.e 6

l I

k I

I e

I e

t i

O A-1

.