FERMI 2 PROCEDURE - MAINTENANCE TITLE:

Mechanical Snubber Maintenance PROCEDURE NUMBER:

35.000.075 REVISION:

3 1

1 SAFETT CLASSIFICATION: SR Billy Moore Name of preparer Billy Hall /s/

Date 07/16/86 Administrative Format Reviewer Gerry Jones /s/

Date 08/26/86 Technical Reviewer (s)

Date Date J. J. Wald /s/

Date 10/07/86 Supervisor, OA Stephen J. Booker /s/

Date 10/07/86 Resp Section Head or OSRO Member / Alternate Further Approval Required for SR or SP Procedures:

R. S. Lenart /s/

Date 10/07/86 OSRO Chairman or Alternate M

R. S. Lenart /s/

Date 10/07/86 Plant Manager The following approved Procedure Change Requests are incorporated in this revision:

M4495 This revision l X does l ldoes not constitute periodic review.

Revision Summary:

Periodic review. Change of format using guidelines of EFM-5015 ARMS - INFORMATION SYSTEMS DSN h(O M.f/)@17Mev 3

Date/*k~h7 DTC TPPADM s n PIS PIS File 1703.02 RecipienI d 7_

  1. Ad 9%Cs'shti (&

q r

8703260250 e70317 PDit ADOCK 05000341 P

PDR

POM 35.000.075 R;visien 3 Page 2 TABLE OF CONTENTS Page 1.0 Purpose......................................

4 2.0 E qu ipme n t Loc a t i on........................... 4 3.0 References...................................

4 4.0 Planning Information.........................

5 5.0 Precautions and Limitations..................

6 6.0 Prerequisites................................

7 7.0 Procedure....................................

8 7.1 Overhaul of Models PSA-1/4 and PSA-1/2.............................

8 7.2 Overhaul of Models PSA-1, PSA-3, and PSA-10.............................

18 g

7.3 Overhaul of Models PSA-35 and PSA-100..

31 7.4 Paddle Bearing Replacement.............

44 7.5 Post Maintenance Inspection, Testing and Restoration........................

44 ENCLOSURES PSA-1/4, PSA-1/2 Snubber Illustration, Parts List Inspection Locations and Reference Points (071986)...............................

PSA-1, PSA-3 and PSA-10 Parts Illustration, Parts List and Inspection Location Reference Points (071986)...............................

PSA-35 and PSA-100 Parts Illustration, Parts List and Inspection Location Reference Points (071986)...............................

PSA-1/4, PSA-1/2, PSA-1, PSA-3, PSA-10, PSA-35, and PSA-100 Special Tools and Fixtures (071986).............................

Paddle Bearing Staking (081386).................

100/ R611/1.0 102486

POM 35.000.075 Revision 3 Page 3 TABLE OF CONTENTS (CONT'D)

ATTACHMENTS 3

PSA-1/4 and PSA-1/2 Maintenance Data Sheet (081386)...............

PSA-1, PSA-3 and PSA-10 Maintenance Data Sheet (081386).......................... Attachment 2 PSA-35 and PSA-100 Maintenance Data Sheet (081386) Attachment 3 t

I POM 35.000.075 Revision 3 Page 4 1.0 PURPOSE 1.1 This Procedure provides information for the disassembly, inspection, and assembly of the Pacific Scientific Mechanical Dynamic Restraints (Snubbers) Model Numbers PSA-1/4, PSA-1/2, PSA-1, PSA-3, PSA-10, PSA-35, and PSA-100.

1.2 Only those sections that apply to the intended maintenance action need be performed. Steps within those sections performed must be completed in the sequence given unless otherwise indicated.

1.3 This Procedure addresses the concerns of Reference 3.2.4 Fermi 2 Technical Specification 3/4.7.5, Snubbers.

2.0 EQUIPMENT LOCATION "Not Applicable"

3.0 REFERENCES

3.1 Use Reference 3.1.1 Plant Operations Manual (POM) Procedure, 12.000.015, PN-12 (Work Order) Processing 3.1.2 POM Procedure, 12.000.055, In Process Material Control and Approved / Controlled Consumable Material Control 3.1.3 POM Procedure, 34.000.07, Snubber Functional Test 3.2 Source Reference 3.2.1 Nuclear Operations Policies and Programs Manuals 3.2.2 ANSI /ASME OM-4, Examination and Performance Testing of Nuclear Power Plant Dynamic Restraints (Snubbers )

l 3.2.3 ASME Code Section XI 3.2.4 Fermi-2 Technical Specification 3/4.7.5, Snubbers 3.2.5 POM Procedure, 31.000.02, Maintenance Record System 3.2.6 POM Procedure, 31.000.04, Control of Calibrated Maintenance Equipment 3.2.7 POM Procedure, 32.000.12, Requirements for Operation of Cranes, Hoists, and Lifting Devices 3.2.8 POM Procedure, 12.000.013, Radiation Work Permit i

i i

(

PON 35.000.075 Revision 3 Page 5 3.2.9 LUBE-001, EF-2 Lubrication Manual 3.2.10 EF-2 Approved / Controlled Materials Manual 3.2.11 Wyle Laboratories Model 100 Snubber Test Machine Serial No.101 Operating Manual 3.2.12 EF-2 Banger Control System Susmary Report, EFER 100 3.2.13 Pacific Scientific Repair and Overhaul Manual for Model PSA-1/4 and PSA-1/2 Mechanical Shock Arrestors 3.2.14 Pacific Scientific Repair and Overhaul Manual for Model PSA-1, PSA-3, and PSA-10 Mechanical Shock Arrestors 3.2.15 Pacific Scientific Repair and Overhaul Manual for PSA-35 and PSA-100 Mechanical Shock Arrestors 3.2.16 Pacific Scientific Installation and Maintenance of Mechanical Shock Arrestors, B21-01-000-SG-007 4.0 PLANNING INFORMATION 4.1 General 4.1.1 Manpower and equipment not listed should be specified in the Work Order Package.

4.2 Messuring and Test Equipment 4.2.1 Measuring and test equipment (M&TE) used in the performance of this maintenance task shall be documented on Attachment 1, 2 or 3 as applicable.

4.3 consumable Materials 4.3.1 Any consumable material which is to be used in lieu of an ites specified in this section shall be authorized for use by Nuclear Engineering and documented in the Remarks section of Attachment 1, 2 or 3 as applicable.

3 y

l t

-e POM 35.000.075 Revision 3 Page 6-d.3.2 The following consumable material shall be used in the performance of this procedure.

'.11 - Chevron NRRG 159 Lubricant.

2.

Loctice Retaining C'ompound F469.

^

3.

Cobehn solvent or the equi 5alent 4.

Lint free cloths 5.

Fel-Pro N-5000 t

6.

Solvent P-D-680

~~

4.4 Special Tools and Eadipment 1.

Refer to Enclosure 4 for List of Special Tools and fixt.ures.

x 5.D PRECAUTIONS AND LIMITATIONS 5.1 Establish a bo'undary around the work area. Houiekeeping and cleanliness requirements of Reference 3.1.3 POP Frocedure, 12.000.048, " Plant Housekeeping" shall be observed.

5.2 Establish a designated storage area for parts removed during disassembly and tag parts removed to ensure proper identification and reinstallation. If QA Level' 1 or ASME Equipme:r., stcre and s

tag parts in accordance with Reference 3.1.2 PCM Prc edure,

~

12.000.055, "In Proc.eas. daterial Control and approved / Controlled Consumable Materiad Contre!." Record storage location in the Rer. arks Section of the app 11:able attachment.

5.3 Materials will be used and controlled in accordance with Referhnce 3.1.2 in the performance of this procedure.

5.4 The following exclusive materials shall be' used in the performance of this procedure. No substitutes may be accepted.

5.4.1 Chevron NRRG 159 Lubricant.

5.4.2 Loctiie Retsiaing Compound RC40.

5.5.Special tools and holding fiTtures supplied by Pacific Reientific or equivalents are needed to overhaul snubbers. Refer te Etelosure 4 for a list of special to,ols and holding fixtu:en.

5.5 only those persons who have coup etfo the Wyle 100 Snubber Test

. Machine f. raining or who have received equivalent training vill operate the Snutber Test Machine.

s

{

s

.-_-__________m_

(,..

e P0H 35.000.075 N

Revision 3 i

Page 7 s

5.7 ' onif those persons who have completed the Pacific Scientific

3-Snabber Overhaul Training or have received equivalent training

/~)

will overhaul and/or repair Pacific Scientific Snubbers.

/

5.8 Disassembly of Pacific Scientific Snubbers is limited to those parts and assemblies listed in the enclosures. Prior to disassembly, read the applicable enclosure to determine extent of disassembly. Each assembly listed in the enclosures is a critical item requiring special techniques and tooling for repair and overhaul. Parts for these assemblies are not procurable.

6.0/-PREREQUISITES 6.1 The Nuclear Shif t Supervisor has been notified concerning the maintenance activity that will be performed and the subject equipment has been released for this maintenance procedure in accordance with Reference 3.1.1, POM Procedure 12.000.015, PN-21

[ Work Order] Processing.

6.2. The Snubber has been removed in accordance with Reference 3.1.3, PCM Procedure 34.000.07, " Snubber Functional Test" and has been transported to the disassembly area.

i 1

6.3 Enter Snubber Serial Number and Model Number in the applicable attachment of this procedure.

6.4 The Work Leader assigned the responsibility for performing this procedure has reviewed the work plan and understands the total job. He shall sign the Maintenance Data Sheet's " Prerequisites Met" alot (Attachment 1, 2, or 3) to document this understanding and that all other prerequisites have been met.

e

\\

l t

i t'

l

\\

r,___.,._

^

r i

,1 POM 35.000.075 Revision 3

[

Page 8 4

7.0 PROCEDURE 3

NOTE (1): ANSI /A3HE OM-4 requires that an Inservice Examination Failure Evaluation be performed, and the failed snubbers be grouped by the failure modes of generic, application induced, isolated, or unexplained see Reference 3.2.2, ANSI /ASME CH-4 Examination and Performance Testing of Nuclear Power Plant Dynamic Restraints (Soubbers) for 3'

definitions of modes.

NOTE (2): Conditions discovered during the overhaul / repair of<a snubber, not noted elsewhere in the applicable attachment, that will aid in this evaluation should be noted in 'the Remarks Section of the applicable attachment, l

O 7.1 Overhaul of Models PSA-1/4 and PSA-1/2 t

NOTE:

Refer,to Enclosure 1 for component identification and Ecciosure 4 for special tools and fixtures.

t rt 7.1.1 Disassembly 1.

Match-mark and remove the transition tube or rear bracket assembly as' applicable.

NOTE:

Disassembly is < limited to removal of f

those parts and assemblies listed in enelosure'l parts list. Prior to s

attempt ing disassembly of arrestor, read enclosure 1 to determine extent of disassembly permitted.

I CAUTION l

l Do not disassemble housing and insert!

l assembly (4), rod and bearing I

i assembly (19), or torque carrier and l l assembly (14); detail parts for these!

I assemblies are not procurable. Eachl

,~

j assembly is a critical item requiring'

,3.

/

l special techniques and tooling for l

l repair and overhaul.

I 2.

Match-mark the housing and install. essembly (4) to f

the inner tube (25) (insure match-marks will be visible with the outer tube installed).

c 3.

Using Truarc pliers, No. 03, remove and discard l

retaining ring (1) to free outer tube (2) from rod L

and bearing assembly (19),

f

(

i i

=

POM 35.000.075 R:visien 3 Page 9 4.

Using Truarc Pliers, No. 05 remove retaining ring (3) to free housing and inertia mass assembly (8) from inner tube (25). Discard retaining ring.

5.

Remove and discard ball (5) from housing and insert assembly (4).

[

6.

Remove washers (6, 7) from shaft of torque carrier and shaft assembly (14).

7.

Foc future reference record thickness of washers (7) used to determine quantity to install at reassembly. Discard washers.

8.

Remove inertia mass (8) from shaft of torque carrier and shaf t assembly (14). Remove and discard clutch spring (12) from inertia mass.

l l

9.

Remove and discard flat washer (13) from shaft of torque carrier and shaf t assembly (14).

10. Unscrew torque carrier and shaft assembly (14) from rod and bearing assembly (19).

11. Remove and.iiscard keeper rings (9) and capstan spring (10) from torque carrier and shaft assembly (14).

'2.

Remove and discard retaining ring (18) to free support washer (16) from inner tube (25).

I 13.

Remove retaining ring (1) with a probe placed in one of retaining ring holes, to free guide plate j

(24) and anti-rotation key (17).

14.

Discard retaining ring and anti-rotation key.

15. Extend rod and bearing assembly (19) fully to slide out of inner tube (25).
16. Using pivot bearing driver, No. 1801104-AT-2-2, and jam nut adaptor, No. 1801104-AT-2-1, loosen jam nut (20) and pivot bearing (22).
17. Hold pivot bearing in place and loosen jam nut.
18. Remove and discard jam nut lockwasher (21), pivot bearing, and ball (23).
19. Remove guide plate (24) from rod and bearing assembly (19).

t

POM 35.000.075 Revision 3 Page 10 7.1.2 Cleaning l

CAUTION I

I I

l SOLVENT P-D-680 OR APPROVED EQUIVALENT IS TOXIC AND l

l FLAMMABLE. AVOID PROLONGED CONTACT WITH SKIN AND KEEli l AWAY FROM OPEN FLAME. USE ONLY IN A WELL-VENTILATED l l AREA.

l l

CAUTION l

l l

l EYE PROTECTION SHOULD BE WORN WHEN COMPRESSED AIR IS l l USED TO DRY PARTS.

l l

CAUTION l

I I

l DO NOT IMMERSE TORQUE CARRIER AND SHAFT ASSEMBLY (14)l l OR ROD AND BEARING ASSEMBLY (19) IN SOLVENT. LEAKAGEi l OF SOLVENT INTO INTERIOR OF TORQUE CARRIER AND SRAFT l l ASSEMBLY WILL REMOVE LUBRICANT FROM INTERNAL PARTS I

l WHICH CANNOT BE RELUBRICATED.

l 1.

Wash all disassembled parts, except torque carrier and shaft assembly (14), and rod and bearing assembly (19), in solvent, using a non-metallic brush to loosen caked sediment and other foreign material.

2.

Wipe external surfaces and torque carrier of torque carrier and shaft assembly (14) and rod and bearing assembly (19) with a clean lint-free cloth moistened with solvent.

I 3.

Dry all parts using a clean lint-free cloth and/or filtered, dry compressed air at 20 psig maximum.

P0H 35.000.075 Revisien 3 P;gs 11 7.1.3 Inspection NOTE (1): Insure parts are free of rust, corrosion, dirt, grease, oil, and other contamination.

NOTE (2): Replace any part that cannot be reworked to meet inspection requirements. If defective part is repairable, note defect in remarks section.

NOTE (3): Brinell marks are allowed at edges of the torque carrier and shaft assembly (14) that contact tangs of capstan spring (10).

1.

Complete the following general inspection as follows:

a.

Visually check that all parts are clean and free from corrosion and deterioration.

b.

Check security of all parts not removed during disassembly, c.

Visually check all threaded parts for crossed or damaged threads. Reject parts if thread damage exceeds 50 percent of one thread. If damage to any one thread is 50 percent or less, note defects in Remarks section of.

d.

Check finishes of all metal parts for damaged or worn-through areas.

Note any defects in Remarks section of Attachment 1.

e.

Check all parts for burrs, nicks, scratches, cracks, or structural damage.

2.

Perform the following detail inspection. Refer to l

Sheet 3 of Enclosure 1 for Ic;aticus of detail parts and assemblies listed. Document results on i

POM 35.000.075 Revision 3 Page 12 NOMENCLATURE TYPE CHECK ACCEPTANCE AND INDEX NO.

OF CRITERIA (SEE ENCLOSURE 1)

INSPECTION PAGE 3 a.

Outer Tube (2)

Visual Evidence of deformation Bore of outer which may cause bore to tube shall be bind on inner tube during round and not operation.

interfere with outside dia-meter of inner tube b.

Torque Carrier Visual Check condition of ball Ball socket and Shaft socket at each and of must not show Assembly (14) shaft, condition of evidence of external threads.

damage or be deformed. No thread form damage allowed.

Dimensional Using torque carrier Runout shall not and shaft assembly exceed 0.005 in, runout test fixture (P/N 1801104CF1),

check runout on shaft.

c.

Rod and Bearing Visual Check spherical bearing Bearing shall Assembly (19) for freedom of rotation rotate smoothly and security of instal-without binding.

lation.

Visual Check condition of No evidence of internal threads and wear allowed.

for wear or galling on bearing surfaces.

Dimensional Using helical com bearing Shall be concen-concentricity fixture tric within 0.005 (P/N 1801533-CF-1),

inch.

check helical can bear-ing for concentricity to plug seat.

d.

Inner Tubs Visual Evidence of deformation Surface of inner Assembly (25) which may cause surface tube shall be to bind on outer tube round and not to during operation.

interfere with inside diameter of outer tube.

POM 35.000.075 Revision 3 Page 13 NOMENCLATURE TYPE CHECK ACCEPTANCE AND INDEX NO.

OF CRITERIA (SEE E4 CLOSURE 1)

INSPECTION PAGE 3 Visual Check for wear on surface.No evidence of mating with capstan wear allowed.

spring.

e.

Nameplate (27)

Visual After reassembly and Nameplate shall test, check nameplate be securely for security of attach-attached by drive ment.

screws.

7.1.4 Parts and Assembly replacement NOTE (1): The following paragraphs provide general replacement instructions for the arrestor:

NOTE (2): Brinell marks allowed at the edges of the carrier on the torque carrier and shaft

' assembly (14) that contact tangs of capstan spring (10).

NOTE (3): Replace torque carrier and shaft assembly (14), or rod acd bearing assembly (19), as an assembly if any part is defective. Detail parts of these assemblies are not procurable separately.

1.

Replace the following at each overhaul, regardless of condition.

a.

Retaining rings (1, 3, 15, and 18) b.

Flat washers (6, 7, and 13) c.

Support washer (16) d.

Lock washer (21) e.

Clutch spring (12) f.

Keeper rings (9) 3 Capstan spring (10) h.

Balls (5, 23) l l

1

i POM 35.000.075 Revision 3 Page 14 i.

Anti-rotation key (17) j.

Pivot bearing (22) k.

Jam nut (20) 2.

Replace parts where damage prevents complete and proper sating of parts and sealing surfaces.

3.

Replace any damaged threaded parts.

7.1.5 Assembly 1.

Lubricate parts as follows:

I CAUTION

\\

l I

l USE LUBRICANT SPECIFIED IN SECTION 5.4.1 ONLY.

l l NO SUBSTITUTE IS APPROVED FOR USE IN THE l

l ARRESTOR.

I a.

Using bearing, P/N 1801533-01, apply a light film of lubricant to shaft of leadscrew; then wipe off with lint-free cloth.

b.

Using a clean, lint-free cloth dampened with Item 4.3.2.3, wipe chromed surface of capstan of inner tube (25) clean of all oil or grease.

c.

Coat entire chromed surface with a light film of lubricant; then, wipe with a clean, dry, lint-free cloth.

2.

Using needle nose pliers, Install one new keeper ring (ii in bottom s.

slot in bore of torque carrier and shaf t assembly (14).

b.

Install new capstan spring (10) and second new keeper ring (9).

Verify proper seating of keeper rings and c.

capstan spring.

3.

Install new clutch spring (12) in bore of inertia mass (8). Make certain that clutch spring is centered in groove in inertia mass.

I Install new ball (5) into small bore of housing 4.

and insert assembly (4).

t i

l l

l k

POM 35.000.075 Revision 3 Fage 15 5.

Install new support washer (16) into groove in inner tube (25), and install new retaining ring (15) securing washer in place.

6.

Insert outer tube (2) onto inner tube (25).

7.

Install guide plate (24), with code number towards plug end, onto rods of rod and bearing assembly (19).

8.

Install rod and bearing assembly and guide plate into inner tube (25).

9.

Retain rod and bearing assembly in extended position and push guide plate down inside diameter of inner tube past groove for retaining ring (1).

10. Using Truare pliers, install new retaining ring below top of inner tube.
11. Use another guide plate to push retaining ring down to seat in groove. Verify proper seating of ring.
12. Fully extend rod and bearing assembly (19), then use a probe placed in a hole of the retaining ring (1) to turn retaining ring until hole for anti-rotation key (17) in inner tube (25) is visible between tangs of retaining ring.

l 13.

Install new anti-rotation key (17) using Magnet l

Tool, Part No. 1801104-MIT-2, to align and place key in hole of inner tube (25).

I Full rod and bearing assembly (19) so that a.

key is aligned with slot in guide plate (24).

14. Maintain rod and bearing assembly in a fully extended position to prevent key from falling out of inner tube (25).

l

15. Install torque carrier and shaf t assembly (14) into rod and bearing assembly (19).
16. Thread torque carrier and shaft assembly into rod i

and bearing assembly until movement is felt at l

plug and.

17.

Install new flat-washer (13) on shaf t of torque carrier and shaft assembly.

POM 35.000.075 Revision 3 Page 16 18.

Install inertia mass (8) on shaft of torque carrier and shaf t assembly (14) making sure that capstan spring (10) tangs are aligned between lips of clutch spring (12) in inertia mass.

19. Check inertia mass for freedom of movement and verify that rotational movement is 20 degrees maximum.

20.

Install new flat washers (6 and 7) the same thicknesses as old flat washers (13) as removed in disassembly.

s.

If exact thickness of washers are not known, c

install two washers (6), one washer (7), and proceed to next step.

21. Taking care not to lose washers (6 and 7) or ball (5), install housing and insert assembly (4).

22.

Using Truare pliers, install new retaining ring 2

(3) securing housing and insert assembly (4) in place.

23.

Shake back and forth lengthwise and listen for a rattle indicating inertia mass has a slight lateral movement.

24. If no movement is detected, remove one washer (7) and test again. Continue this process until a slight movement of the inertia mass is detected.

NOTE :

Washers (7) are 0.010 inch thick, therefore final inertia mass movement will be between 0.001 and 0.009 inch when proper installation is achieved.

Housing and insert assembly may rotate, but may not move up and down.

25.

If excessive rattle, and thus excessive lateral movement of the inertia mass is detected, install additional washers (7) until no movement is noticed, then remove one washer (7).

26. Thread new pivot bearing (22) fully into guide plate (24) and back out to insure threads do not bind in guide plate.

If any hesitation or binding is noticed, a.

discard both parts and replace with new parts.

POM 35.000.075 Revision 3 Page 17 27.

Install new ball (23) and pivot bearing (22) in bore of guide plate (24).

28.

Install new lock washer (21) and jam nut (20) on pivot bearing.

29. Tighten Pivot bearing (22) using pivot bearing driver, Part No. 1801104-AT-2-2 and jam nut adaptor, Part No. 1801104-AT-2-1; then back off approximately 60 to 90 degrees.

30. Holding pivot bearing (22) in place:

a.

Torque jam nut (20) to 25 inch pounds (24 -

26 in.1bs.); using jam nut adaptor and torque wrench No 6003. Document on.

31. Move outer tube (2) over shoulder of end plug.

Using Truarc Pliers, install new retaining ring (1) into groove on inside diameter of outer tube (2).

32.

Slowly extend and retract rod and bearing assembly (19) several times and verify there is no detectable binding or hesitation throughout the full stroke operation.

33. Adjust the housing and insert assembly (4) to the inner tube (25).

a.

Lightly clamp the snubber in a soft jawed vice in a vertical position with the telescoping end (rear bracket) up.

I CAUTION j

i l

l Do not relax the downward pressure and do l

lnot remove the retaining ring. Only relieve!

l the grip enough to allow for free rotation l l of the lua.

I b.

Using the Truere pliers relax the grip of the retaining ring (3). Do not relieve the retaining ring.

c.

While lightly pressing down on the paddle lug, turn the telescoping end to align the match marks then allow the retaining ring (7) to seat solidly.

POM 35.000.075 Revision 3 Page 18 d.

Remove the snubber from the vice.

Slowly stroke the snubber to check for e.

binding.

NOTE:

If snubber is to be functionally tested with the extension tube removed, do not install the extension tube until after functional testing.

34.

Install the rear bracket or extension tube as follows:

Align match-marks made during disassembly in a.

(Step 7.1.1.1).

b.

Lubricate the bolts with Item 4.3.2.4.

Torque bolts to 22 inch pounds (20 - 24 in.

c.

Ibs.) Document on Attachment 1.

d.

Lockwire with.040 inch diameter stainless steel lockwire.

e.

Slowly stroke the snubber to ensure no binding.

7.1.6 Document the completion of Section 7.1 on Attachment 1.

7.2 Overhaul of Models PSA-1, PSA-3, and PSA-10 NOTE:

Refer to Enclosure 2 for component identification and for special tools and fixtures.

7.2.1 Disassembly NOTE:

Disassembly is limited to removal of those parts and assemblies listed in Enclosure 2 parts list.

I CAUTION I

I I

l Do not disassemble end plug assembly (25), I lor support cylinder assembly (33); detail l lparts for these assemblies are not l

l procurable. Each assembly is a critical l

l item requiring special techniques and l

l tooling for repair and overhaul.

I 1.

Hatch-mark and remove the transition tube or rear bracket as applicable.

FON 35.000.075 Revision 3 Page 19 2.

Remove retaining ring (1) and dust cover (2) from housing (7). Discard retaining ring.

I CAUTION l

l l

l UBEN PERFORMING FOLLOWING STEP 7.2.1.3, USE CARE l l TO AVOID SHEARING EEADS FROM FILISTER READ SCREWS!

l(3). IF SUCH OCCURS, END PLUG ASSEMBLY (21) l lMUST BE REPLACED.

i NOTE (1): Threads of filister head screws (3) are coated on installation with Item 4.3.2.2 Loctite Retaining Compound to prevent loosening.

NOTE (2): To remove screws, it may be necessary to use a screwdriver and an adjustable wrench to develop sufficient torque to rotate screws. Attach adjustable wrench to shank of screwdriver, not to handle.

3.

Remove and discard filister head screws (3) and flat washers (13) to frae position indicator tube (5) from end plus assembly (25).

4.

Slide off position indicator tube (5).

5.

Match-mark the housing (7) to the support cylinder assembly (33) (insure the match mark will be visible with the outer tube installed).

6.

Using heavy duty truarc pliers, remove and discard retaining ring (6) to free housing (7) from support cylinder assembly (33).

l CAUTION 1

1 I

I INSTALL ARRESTOR IN HOLDING FIKTURE WITH FIKTURE l l CLAMPED AROUND SUPPORT CYLINDER ASSEMBLY (33),

1 INOT AROUND TELESCOPING CYLINDER. CLAMPING FORCE l l MAY PERMANENTLY DEFORM TELESCOPING CYLINDER.

l 7.

Install and cleep arrestor horisontally in appropriate holding fixture.

8.

Using Truarc Fliers, Part No. RE-0150, remove retaining ring (8) from ball screw shaf t.

a.

Slide off flat washers (9, 10, and 13) and inertia muss (11).

POM 35.000.075 Revision 3 Page 20 b.

Discard retaining ring and flat washers.

9.

Remove clutch spring (12) from bore of inertia mass (11).

10. Using Truarc Pliers, Part No. RE-0150, remove retaining ring (14) from shaft of leadscrew.

Slide off flat washers (13 and 15) and torque a.

drum (16).

b.

Discard retaining ring and flat washers.

NOTE:

If machine key (28) comes off with torque drum (16), reinsert into slot in the inner race (29) and key way in shaft of ball bearing screw assembly (27).

11. Using needle nose pliers, remove one keeper ring (17) to free capstan spring (18) from bore of torque drum (16).

a.

Remove capstan spring and second keeper ring (19).

b.

Discard capstan spring and keeper rings.

I CAUTION I

I I

l DO NOT REMOVE SETSCREWS (24), UNLESS IT IS l

l NECESSARY TO REMOVE END PLUG ASSEMBLY (25) FOR l

l REPLACEMENT. IF NECESSARY, USE A DRILL WITH l

l DRILL SIZE NO. 30 FOR PSA-1 AND NO. 23 FOR PSA-3 l l AND PSA-10, TO REMOVE DISTORTION ON THREADS OF l

l TELESCOPING CYLINDER, CAUSED BY SETSCREW. DRILL l l ONLY TO DEPTH NECESSARY TO REMOVE DISTORTION SO l l THAT END PLUG ASSEMBLY CAN ROTATE FREELY. USE l

l EYE PROTECTION, AND REMOVE ANY LOOSE DRILL l

l SHAVINGS WITH CLEAN COMPRESSED AIR.

l

12. Using Allen Wrench, remove and discard setscrews (24) form support cylinder assembly (33).
13. Remove end plug assembly as follows; a.

Install arrestor in holding fixture, Part No.

1801103AT4.

POM 35.000.075 Revision 3 Page 21 b.

Install appropriate torque wrench adapter on end plug assembly (25).

Using breaker bar as a lever, rotate end plug c.

assembly counterclockwise to loosen.

d.

Remove breaker bar and torque wrench adapter.

I CAUTION l

l 1

l IF TELESCOPING CYLINDER ROTATES WHEN END PLUG l

l ASSEMBLY (25) ROTATES COUNTERCLOCKWISE, INTERNAL l l DAMAGE HAS OCCURRED. (BALLSCREW ASSEMBLY HAS l

l BECOME UNSTAKED). SUPPORT CYLINDER ASSEMBLY (33) l l MUST BE REPLACED, AND DEFECTIVE SUPPORT CYLINDER l l ASSEMBLY RETURNED TO PACIFIC SCIENTIFIC FOR l

l REPAIR.

l Unscrew and remove end plug assembly (25) e.

from telescoping cylinder of support cylinder assembly (33).

7.2.2 Cleaning l

CAUTION I

I I

l SOLVENT P-D-680 OR APPROVED EQUIVALENT IS T0XIC l lAND FLAMMABLE. AVOID PROLONGED CONTACT WITH SKIR lAND KEEP AWAY FROM OPEN FLAME. USE ONLY IN A l

l WELL-VENTILATED AREA.

l l

CAUTION l

1 l

l EYE PROTECTION SHOULD BE WORN WHEN COMPRESSED AIR' I IS USED TO DRY PARTS.

l l

CAUTION I

l l

l DO NOT DetERSE SUPPORT CYLINDER ASSEMBLY (33) IN l l SOLVENT. LEAKAGE OF SOLVENT INTO INTERIOR OF l

l SUPPORT CYLINDER ASSEMBLY WILL REMOVE LUBRICANT l l PROM INTERNAL PARTS WHICM CANNOT BE RELUBRICATED.I 1.

Wash all disassembled parts, except support cylinder assembly (33), in solvent, using a non-metallic brush to loosen caked sediment and other foreign material.

l

POM 35.000.075 Revision 3 Page 22 2.

Wipe external surfaces of support cylinder essembly (33) with a clean lint-free cloth ac'stened with solvent.

3.

Dry all parts using a clean lint-free cloth and/or clean compressed air at 20 psig maximum.

7.2.3 Inspection NOTE (1): Parts must be free of rust, corrosion, dirt, grease, oil, and other contamination.

NOTE (2): Replace any part that cannot be repaired or reworked to meet inspection requirements.

NOTE (3): If defective part is repairable, note defect in Remarks Section and assign part for repair.

1.

Complete the following general inspection:

NOTE:

Brinell marks are allowable at edges of torque drum (16) that contact tangs of capstan spring (18).

a.

Visually check that all parts are clean and free from corrosion and deterioration.

b.

Check security of all parts not removed during disassembly.

Visually check all threaded parts for crossed c.

or damaged threads. Reject parts if thread damage exceeds 50 percent of one thread. If damage to any one thread is 50 percent or less, document defects in Remarks section of.

d.

Check finishes of all metal parts for damaged or worn-through areas.

Document any defects in the Remarks section of Attachment 2.

I Check all parts for burrs, nicks, scratches,

e.

cracks, or structural damage.

2.

Perform the following detail inspection. Refer to Sheet 5 of Enclosure 2 for locations of detail l

parts and assemblies listed. Document results on.

I

PON 35.000.075 Revision 3 Page 23 NOMENCLATURE TYPE CHECK ACCEPTANCE AND INDEX NO.

OF CRITERIA (SHEET 5 0F INSPECTION ENCLOSURE 2) a.

Position Visual Evidence of deformation Bore of position Indicator which may cause bore to indicator tube Tube (5) bind on support cylinder shall be round during operation.

and not int er f e re with outside dieseter of support cylinder.

b.

End Flug Visual Check bearing for free-Bearing shall Assembly (25) dom of rotation and rotate smoothly security of installation. without binding.

Bearing shall securely in-atalled.

c.

Support Operational Extend and retract Telescoping Assembly (3) telescoping cylinder cylinder shall through several complete extend and cycles.

retract through full stroke with-out hesitation or binding.

d.

Nameplate (35)

Visual Check nameplate for Nameplate shall security of attachment, be securely l

attached by drive l

screws (34).

l l

POM 35.000.075 Revision 3 Page 24 7.2.4 Parts and assembly replacement 1.

Replace all parts or assemblies that are damaged or wo rn.

NOTE (1): Brinell marks are allowable at edges of torque drum (16) that contact tangs of capstan spring (18).

NOTE (2': Replace end plug assembly (25), or support cylinder assembly (33), as an assembly if any part is defective.

Detail parts of these assemblies are not procurable separately.

2.

Replace the following at each overhaul, regardless of condition, s.

Retaining rings (6, 1, and f) b.

Flat washers (9, 10, 13, and 15) c.

Clutch spring (12) d.

Keeper rings (17 and 19)

Capitan spring (18) e.

f.

Filister head screws (3) g.

Sotscrews (24) 3.

Replace parts where damage prevents complete and proper mating of parts and sealing surfaces.

1 NOTE:

Do not " chase" threads of screw type fasteners.

4.

Chase all damaged threads (if damage to one thread is 50 percent or less) using the appropriate tap or die.

i L

POM 35.000.075 Revision 3 Fage 25 7.2.5 Assembly 1.

Lubricate parts as follows:

I CAUTION l

l l

l Use lubricant specified in Section 5.4.1 only. l lNo substitute is approved for use in the l

l arrestor.

I Using a soft-bristle brush, apply a light a.

film of lubricant to entire ball screw shaft, g

b.

Using a soft-bristle brush, apply a light film of lubricant to external threads of telescoping cylinder (26).

Using a clean, lint-free cloth dampened with c.

Cobehn solvent, wipe chromed surface of m

capstan spring (18) clean of all oil or grease.

d.

' Coat entire chromed surface of capstan spring (18) with a light film of lubricant; then, wipe with a clean, dry, lint-free cloth.

NOTE:

Clamp holding fixture around support cylinder, not around telescoping cylinder.

2.

Install and clamp support cylinder assembly (33) horizontally in appropriate holding fixture.

3.

Using a clean, lint-free cloth dampened with Cobehn solvent, wipe capstan spring diameter of support cylinder assembly (33) clean of all oil or grease.

4.

Coat entire chroned surface of support cylinder assembly (33) with a light film of lubricant; then wipe with a clean, dry lint-free cloth.

5.

Using needle nose pliers:

a.

Install one new keeper ring (19) in bottom slot in bore of torque drum (16).

b.

Install new capstan spring (18) and second new keeper ring (17).

6.

Slide torque drum (16), with assembled parts (19 and 18), on capstan of support cylinder assembly (33).

l

POM 35.000.075 Revision 3 Page 26 NOTE:

Torque drum (16) endplay should be 0.000 to 0.031 inch. If necessary, alter quantity of washers (13 and 15) to obtain proper endplay.

7.

Using Truarc Pliers, Part No. 02, install new flat washers (13 and 15), and retaining ring (14) to secure parts to shaf t of ball bearing screw assembly (27).

8.

Manually extend and retract telescoping cylinder while observing torque drum (16) for freedom of

(

rotation.

9.

Install new clutch spring (12) in bore of inertia mass (11). Make certain that lips of clutch spring are centered on slot in inertia mass.

10.

Install new flat washer (13) on shaf t of ball screw.

11.

Install inertia mass (11) in accordance with the following instructions.

I CAUTION l

l l

l WHEN INSTALLED, BOTH TANGS OF CAPSTAN SPRING (18)l l MUST BE LOCATED IN SLOT INERTIA NASS, BETWEEN l

! CLUTCH SPRING LIPS. SINCE INSTALLATION OF l

l INERTIA MASS IS A BLIND PROCEDURE, PAY STRICT l

l ATTENTION TO THE FOLLOWING INSTRUCTIONS TO VERIFM l PROPER INSTALLATION. D4 PROPER INSTALLATION OF l

l INERTIA MASS WILL CAUSE IMPROPER BRAKING ACTION l lOF THE ARRESTOR DURING OPERATION.

l a.

Rotate torque drum (16) until both tangs of capstan spring (18) are in the uppermost position.

b.

Visually align slot in inertia mass (11) so that tangs of capstan spring (18) are centered between lips of clutch spring (12) in inertia mass.

c.

With shaf t of ball screw centered in hub of inertia mass (11), and tangs of capstan spring (18) visually centered between lips of clutch spring, carefully slide inertia mass straight in until bottomed.

POM 35.000.075 Revision 3 Page 27 d.

Ensure that tangs of capstan spring (18) are properly centered as follows:

1)

Rotate inertia mass (11) quickly clockwise and counterclockwise on shaft of leadscrew.

NOTE (1): If capstan spring (18) tangs are properly centered, the interval between pings will be relatively short, the audible sound will be faint, and the rotational travel between pings will be limited to a few degrees (approximately 5*).

NOTE (2): If capstan spring (18) tangs are improperly centered (only one tang, or neither, between clutch spring lips) the interval between pings will be several times longer, the audible sound will be louder, and the rotational travel between pings will be many degrees greater (approximately 30*).

2)

While maintaining a relatively constant rotational speed, listen for an audible

" ping" as the capstan spring tangs strike the clutch spring lips at the limits of travel. Listen also to the length of the interval between pings.

3)

Repeat proceeding Steps 7.2.5.11.d.1 and 7.2.5.11.d.2 until inertia mass (11) is properly installed.

POM 35.000.075 Revision 3 Page 28 NOTE:

Inertia mass endplay should be 0.005 to 0.020 inch. If necessary, alter quantity of flat washers (9 and 10) to obtain proper endplay.

12. From the following list, use the appropriate Truarc Pliers to install new flat washers (9 and 10); the new retaining ring (8) to secure part to shaft of leadscrew.

Snubber l Truarc Fliers Model Part No.

PSA-1 l RE-015 PSA-3 l RE-018 PSA-10 l RE-03

13. Secure dust cover (2) in bore of housing (7) with new retaining ring (3).

14.

Install housing (7). Using the appropriate Truarc Pliers, install new retaining ring (6), beveled side upward, to secure housing in place.

15. If replaced, screw end plug assembly (25) onto telescoping cylinder of support cylinder assembly until threadr bottom out.

NOTE:

Installation is okay if gauge will not enter gap between end plug assembly and telescoping cylinder, or enters gap with a maximum clearance of 0.010 inch.

16. Fully extend telescoping cylinder. Using Go/No-Go cause, check end plug assembly (25) for proper installation.
17. Using appropriate adapter and torque wrench, torque end plus assembly (25) to 50 inch pound (40-60in. Ibs.).

Document results in.

18. Adjust position of housing (7) so that flate of housing are parallel to sides of end plug assembly (25) within 0.030 inch.
19. Remove assembled arrestor from holding fixture.
20. Torque new setscrews (24) as follows:

a.

Coa t threads of new setscrews (24) with Loctite retaining compound.

POM 25.000.075 Revision 3 Page 29 b.

Using hand torque driver and hex drive, install setscrews in end plug assembly and torque to following values.

Model Torque (in.-lb)

PSA-1 15 in. Ibs. (10 to 20)

PSA-3 20 in. Ibs. (15 to 25)

PSA-10 20 in. Ibs. (15 to 25) c.

Document setscrew torque in Attachment 2.

21. Slide position indicator tube (5) over telescoping 9

tube of support cylinder assembly (33). Rotate tube until mounting holes in tube and end plug assembly (25) are aligned.

22. Coat threads of filister head screws (3) with Loctite retaining compound. Secure position indicator tube (5) to end plug assembly (33) with new filister head screws and new flat washers (4).

23.

If new housing (7) was installed:

Remove drive screws (34) and nameplate (35) a.

from old housing.

b.

Secure nameplate to housing with new drive screws.

24 Adjust the housing (7) to the support cylinder assembly (33) as per the match mark of Step 7.2.1.5 as follows :

Lightly clamp the snubber in a soft jawed a.

vice in a vertical position with the telescoping end (rear bracket) up.

NOTE:

Do not relax the downward pressure and do not remove the retaining ring. Only relieve the grip enough to allow for free rotation of the lug.

b.

Using the truere pliers relax the grip of the retaining ring (6). Do not remove the retaining ring.

c.

While pressing down on the paddle lug, turn the telescoping end to align the match marks then allow the retaining ring to seat solidly.

POH 35.000.075 Revision 3 Page 30 d.

Remove the snubber from the vice and slowly stroke the snubber to check for binding.

NOTE:

If the snubber is to be functionally tested with the extension tube removed, do not install the extension tube until after functional testing.

25. Install the rear bracket or extension tube as per match marks of step 7.2.1.1 as follows:

a.

Lubricate the boir.s with Fel-Pro N-5000 b.

Torque the Rear Leacket or the Extention tube to the following torque values:

Model Torque (in. Ibs.)

PSA-1 45 in. 1bs (40 - 50 in. 1bs.)

PSA-3 120 in 1bs. (110 - 130 in.

Ibs.)

PSA-10 440 in. Ibs. (420 - 460 in.

1bs.)

c.

Document actual torque on Attachment 2.

d.

Lockwire with.040 inch diameter stainless steel lockwire.

e.

Slowly stroke the snubber to ensure no binding.

7.2.6 Document the completion of Section 7.2 on Attachment 2.

l 1

1 l

l

3 i

PON 35.000.075 Revision 3 Page 31 7.3 overhaul of Models PSA-35 and PSA-100 NOTE:

Refer to Enclosure 3 for component identification and for special tools and fixtures.

7.3.1 Disassembly NOTE (1): Disassembly is limited to removal of those parts and assemblies listed in the recommended spare parts list.

NOTE (2): Mark, or otherwise record, rotational alignment of end cap assembly (19) and support cylinder assembly (21) to aid in duplication of alignment during assembly.

I CAUTION I

I I

l Do not disassemble inertia mass assembly (12), torque l l carrier assembly (14), end cap assembly (19), or l

isupport cylinder assembly (21); detail parts for l

l these assemblies are not procurable. Each assembly l

lis a critical item requiring special techniques and l

l tooling for repair and overhaul.

I 1.

Remove Position Indicator Tube (3) if not previously removed during test.

2.

Install and clamp arrestor horizontally in appropriate holding fixture. Clamp around housing of support cylinder assembly (21).

3.

Using mallet and punch, straighten deformations in locking washer (6) in three places to unlock adapter nut (4), or transition tube (5), from housing of support cylinder assembly (21).

4.

Install appropriate torque wrench adapter on adapter nut (4), or on transition tube (5),

depending upon configuration of arrestor being disassembled. Engage adapter setscrews with slots of nut or tube.

5.

Insert breaker bar in socket or torque wrench adapter. Using breaker bar as a lever, rotate adapter nut (4), or transition tube (5),

counterclockwise until lose.

6.

Remove breaker bar and torque wrench adapter ring.

7.

Unscrew and remove adapter nut (4), or transition tube (5). Remove and discard locking washer (6).

POM 35.000.075 Revision 3 Page 32 8.

Remove retaining ring (7) and dust cover (8) from bore of adapter nut (4), or transition tube (5).

9.

Remove and discard cotter pin (9). Remove and discard castellated nut (10) and flat washer (2) to free inertia mass assembly (12) from torque carrier assembly (14).

10.

Extract inertia mass assembly from bore of support cylinder assembly (21) housing.

NOTE:

The ring may be reached through the holes in the bottom of the torque carrier assembly (14).

11. Release retaining ring (7) from capstan. To release the retaining ring, use truare pliers 0500 (PSA 35) or S-6700 (PSA 100).
12. With the retaining ring released, pull on the torque carrier (14) to remove it with assembled parts (11, 12, and 13) from the support cylinder assembly (21).
13. Remove washer (15) (PSA 35) or wear ring (15) (PSA 1001 from pinion gear of torque carrier assembly (14).
14. Using needle nose pliers, remove one keeper ring (16) to free capstan spring (17) from bore of torque carrier assembly (14).
15. Remove and discard capstan spring (17) and second keeper ring (16).

FON 35.000.075 Revision 3 Fage 33 l

CAUTION l

l l

l WHEN PERFORMING FOLLOWING STEP 7.3.1.16. USE CARD i TO AVOID SHEARING HEADS FROM FILISTER READ SCREWS!

l(1). IF SUCH OCCURS, END CAP NUT (20) NUST BE l

l REPLACED.

I NOTE:

Threads of filister head screws (1) are coated on installation with Loctite Retaining Compound to prevent loosening.

To remove screws, it may be necessary to use a screwdriver and a adjustable

(

wrench to develop sufficient torque to rotate screws. Attach adjustable wrench to shank of screwdriver, not to handle.

16. Remove filister head screws (1) and flat washers (11) to free position indicator tube (3) from end cap nut (20). Discard screws and flat washers.
17. Unscrew and remove end cap assembly (19) from telescoping cylinder of support cylinder assembly

( 21 ).

18. Rotate end cap nut (20) clockwise to remove.

POM 35.000.075' Revision 3 Page 34 NOTE:

End cap nut (20) has lef t-hand threads and must be rotated clocivise, rather than counterclockwise to remove.

7.3.2 Cleaning l

CAUTION l

1 l

l l SOLVENT P-D-680 0"t APPROVEL 1,QUIVALENT IS TOIIC AND l

lFIJNMABLE. AVoliFROLMGED' CrHTnCT WITH SKIN AND KEEli l AWAY FROM OPEN F A E.

USE ONLY IN A WELL-VENTII.ATED l l

lAREA.

l CAUTION l

o I

1 l EYE PROTECTION SHOULD BE WORN WHEN COMPRESSED AIR IS e

lUSED TO DRY PARTS.

'_ j I

CAUTION l

i I

l l DO NOT IMMERSE SUPPORT '.l FLINDER ASSr.MBLY (21) IN l

I l SOLVENT. LEAKAGE OF P5LVENT IN,TO INTERIOR OF SUPPORT l l CYLINDER ASSEMBLY WILL REH351 LVLellCANT FROM INTERNAL I l PARTS WHICH CANNOT BE RELU?>?<ICATED.

l 1.

Wash all disassembled parts, except support cylinder asseroSly (11), in solvent, using a non-metallic trast cc loosen caked sediment and other foreign me>.erial.

2.

Wipe external surf a:es of support cylinder assembly (21) with a clean lint-free cloth unistened with solvent.

3.

Dei all parts using a cleso lint-free cloth and/or clean ecmpressed air at 20'p.ig. maximum.

\\

i f

' ^ - ^

\\.

PON 35.000.075 Revision 3 Page 35 7.3.3 Inspection NOTE (1): Replace any part that cannot be repaired or reworked to meet inspection requirements.

NOTE (2): If defective part is repairable, note defect and assign part for repair.

1.

Complete the following inspection:

NOTE:

Brinell marks are allowable at edges of torque carrier assembly (14) that contact tangs of capstan spring (17).

i s.

Visually check all parts are clean and free frem corrosion and deterioration.

. t.

b.

Check to be sure that all rivets and drive screws are tight, and that the unremoved retaining rings, screws, bearings, etc., are securely in place.

c.

Visually check all threaded parts for crossed or damaged threads. Reject parts if thread damage exceeds 50 percent of one thread. If damage to any one thread is 50 percent or less, document defect in Remarks of i

v d.

Check finishes of all metal parts for damaged or worn-through areas. Document any defects

\\

in Remarks of Attachment 3.

Check all parts for burrs, nicks, scratches, e.

cracks, or structural damage. Document any defect in Remarks of Attachment 3.

f 2.

Perform the following detail inspection. Refer to Sheet 3 of Rnclosure 3 for locations of detail parts and assemblies listed. Document results on 3.

s

\\

~

l i

I I

\\

\\

POM 35.000.075 Revision 3 Page 36 NOMENCLATURE TYPE CHECK ACCEPTANCE AND INDEX NO.

OF CRITERIA c

(SHEET 3 0F INSPECTION ENCLOSURE 3)

J!

a.

Inertia Mass Visual Clutch spring for secure Spring shall be Aesembly (12) installation in shell, securely instal-and for evidence'of led. There shall deformation.

be no deforma-s' tion.

Check shell for evidence No cracks, breaks of damage.

or gouges shall be evident.

l Check hub for secure Hub shall be.

riveting to shell and for securely riveted evidence of scoring on in place. There hub shaft caused by defec-shall be no scor-tive ' needle bearing in ing on hub sha f t.

torque carrier assembly.

/

if b.

Torque Carrier Visual Check bearings for free-Bearings shall Assembly (14) dom of rotation and for rotate smoothly, evidence of looseness.

without binding.

Check pinion rear splines Bearings shall for nicks, chips, or be securely cracks.

installed.

c.

End Cap Visual Check bearing for free-Bearing shall Assembly (19) dom of rotatier, and rotate smoothly security of installation.

without binding.

Bearings shall be securely l

installed.

Be. tics ID for evidence None allowed, of elonastion or danare.

I d.

Position Visual Evidence of deformation Bore of position s

Indicator which may cause bore to indicator tube Tube (3) bind on support cylinder shall be round during operation.

and not interfere with outside diameter of support cylinder.

i I

l l

t

POM 35.000.075 Revision 3 Page 37 NOMENCLATURE TYPE CHECK ACCEPTANCE AND INDEX NO.

OF CRITERIA (SEEET 3 0F INSPECTION ENCLOSURE 3) e.

Support Operational Extend and retract tele-Telescoping Cylinder scoping cylinder through cylinder shall Assembly (21) several complete cycles extend and (0 to 6 inches on scale).

retract through full stroke with-Out hesitation or

binding, f.

Nameplate Viaaal Check nameplate for Nameplate shall (23) security of attachment.

be securely attached by drive screws (22).

7.3.4 Repair and Replacement 1.

Replace all parts or assemblies that are damaged or vorn.

NOTE (1): Brinell marks are allowable at edges of torque carrier assembly (14) that contact tangs of capstan spring (17).

NOTE (2): Replace inertia mass assembly (12) torque carrier assembly (14), end cap assembly (19), or support cylinder assembly (21) as an assembly of any part is defective. Detail parts of these assemblies are not procurable separately.

2.

Replace locking washer (6), cotter pin (9),

cate11sted out (10), flat washers (2 and 11),

keeper rings (16), capstan spring (17), and filister head screws (1) at each overhaul, regardless of condition.

3.

Replace parts where damage prevents complete and proper mating of parts and sealing surfaces.

4.

Repair threaded parts, if damage to one thread is 50 percent, or less, by chasing threads with appropriate tap or die. Do not repair screws.

5.

Clean all parts removed or reworked as described in cleaning, Section 7.3.2.

POM 35.000.075 Revision 3 Page 38 7.3.5 Assembly 1.

Lubricate parts as follows:

NOTE:

Use lubricant specified in Section 5.4 only. No substitute is approved for use in the arrestor.

a.

Using a soft-bristle brush, apply a light film of lubricant to threads of adapter nut (4), or transition tube (5), end cap assembly (19), and end cap nut (20).

1)

Using a soft-bristle brush, apply a light film of lubricant to splines of pinion gear.

.i Pack ball bearings and needle bearings so that the cavity around the balls or needles is approximately half filled with grease. Use fingers for the ball bearings and a small probe, stick or syringe for the needle bearings.

b.

Lubricate support cylinder assembly (21) as follows:

1)

Using a soft-bristle brush, apply a light film of lubricant to threads of telescoping cylinder and cylinder housing, and to splines of planetary gears until lubricant is distributed evenly over splined surfaces.

2)

Manually extend and retract telescoping cylinder to rotate planetary gears until lubricant is distributed evenly over splined surfaces.

NOTE:

Clamp holding fixture around housing of support cylinder assembly (21), not around telescoping cylinder.

2.

Install and clamp support cylinder assembly (21) horizontally in appropriate holding fixture.

NOTE:

End cap nut (20) has left-hand threads and must be rotated counterclockwise, rather than clockwise, to tighten.

3.

Install end cap nut (20) on telescoping cylinder of support cylinder assembly (21).

I

POM 35.000.075 Revision 3 Page 39 a.

Manually rotate end cap nut counterclockwise until finger tight against shoulder of telescoping cylinder.

4.

Install end cap assembly (19) in telescoping cylinder until end cap bottoms against telescoping cylinder.

NOTE (1): Rotate end cap assembly (19) clockwise to tighten. Just before end cap l

assembly bottons on telescoping

(

cylinder, rotate end cap assembly with a quick, snappy action so that it seats snugly against cylinder.

NOTE (2): This adjustment is necessary to assure proper orientation of end cap assembly (19) with accessory parts during installation.

I CAUTION i

l I

l ROTATION OF END CAP ASSDiBLY (19)

I i

l l SHALL BE RESTRICTED TO MINIMUM l

lNECESSARY TO OBTAIN ALIGNMENT. UNDER1 lNO CIRCUMATANCE SHALL END CAP ASSEMBLY, l BE ROTATED MORE THAN ONE TURN FROM ITs l BOTTOMED POSITION ON END CAP NUT (20).!

5.

Rotate end cap assembly (19) counterclockwise until alignment marks placed on end cap assembly and support cylinder assembly (21) are aligned.

6.

Torque end cap nut (20) to 150 ft. Ibs. as follows:

I a.

Using two screws provided, secure appropriate torque wrench adapter to end cap nut (20).

b.

Insert torque wrench in socket of torque wrench adapter.

c.

Using torque wrench as a lever, rotate end cap aut (20) clockwise, against end cap assembly (19), until torque wrench clutch slips, indicating that proper torque has been applied. Document torque on Attachment 3.

d.

Remove torque wrench and torque wrench adapter.

l

POH 35.000.075 Revision 3 Page 40 7.

Install capstan spring as follows:

Using needle nose plidrs, install one new a.

keeper ring (18) in bottom slot in bore of shell of torque carrier assembly (14).

b.

Install new capstan spring (17).

Install Second new keeper ring (18).

c.

NOTE:

Washer (15) and wear ring (15) perform the same function.

8.

Install washer (15) PSA 35) or wear ring (15)

PSA 100) on pinion gear of torque carrier assembly (14). Apply a light coat of grease to washer or wear ring.

9.

Slide torque carrier assembly (14), with assembled parts (15, 12, and 17) on capstan of support cylinder assembly (21).

Wiggle torque carrier assembly back and forth a.

until pinion gear engages planetary gears and torque carrier is fully seated.

~

b.

Using Truarc Pliers, instal 1 retaining ring in capstan, c.

Ensure that retaining ring is properly seated.

10. Manually extend and retract telescoping cylinder while observing torque carrier assembly (14) for freedom of rotation.

l t

1 i

l POM 35.000.075 Revision 3 Page 41 11.

Install inertia mass assembly (12) in accordance with the following instructions:

1 l

CAUTION

[

l I

l WHEN INSTALLED, BOTH TANGS OF CAPSTAN SPRING (17)i l MUST BE LOCATED IN SLOT OF INERTIA MASS SHELL, l

l BEIVEEN CLUTCH SPRING LIPS. SINCE INSTALLATION l l OF INERTIA MASS ASSEMBLY (12) IS A BLIND l

l PROCEDURE. PAY STRICT ATTENTION TO THE POLLOWING l l INSTRUCTIONS TO VERIFY PROPER INSTALLATION.

l l IMPROPER INSTALLATION OF INERTIA MASS ASSEMBLY l

l WILL CAUSE IMPROPER BRAKING ACTION OF THE l

l ARRESTOR DURING OPERATION.

I Rotate the torque carrier assembly (14) until a.

the tangs of the capstan spring (17) are pointing up.

b.

Visually align slot in shell of inertia mass assembly (12) so that tangs of capstan spring (17) are centered between lips of clutch spring of inertia mass assembly.

With bolt of torque carrier assembly (14) c.

centered in hub of inertia mass assembly (12), and tangs of capstan spring (17) visually centered between lips of clutch spring, carefully slide inertia mass assembly straight in until bottomed, d.

Verify that tangs of capstan spring (17) are properly centered as follows:

1)

Rotate inertia mass assembly (12) quickly clockwise and counterclockwise on bolt of torque carrier assembly (14).

l i

1 I

i

POM 35.000.075 Revision 3 Page 42 NOTE (1): If capstan spring (17) tangs are properly centered, the interval between pings will be relatively short, the audible sound will be faint, and the rotational travel between pings will be limited to a few degree (approximately 5').

NOTE (2): If capstan spring (17) tangs are improperly centered (only one tang, or neither, between clutch spring lips) the interval between pings will be several times longer, the audible sound will be louder, and the rotational travel between pings will be many degrees greater (approximately 30').

2)

While maintaining a relatively constant rotational speed, listen for an audible

" ping" as the capstan spring tangs strike the clutch spring lips at the limits of travel. Listen also the length of the interval between pings.

3)

Repeat preceding steps (1) and (2) until certain that inertia mass (12) is properly installed.

12.

Secure inertia mass assembly (12) to bolt of torque carrier assembly (14) with new castellated (10) and new flat washer (2).

nut

13. Tighten castellated nut (10) against washer; then, rotate nut counterclockwise until next groove is aligned with cotter pin hole in bolt of torque carrier assembly (14).

14.

Install cotter pin (9) to retain caste 11sted nut I

I (10).

15. Secure dust cover (8) in bore of adapter nut (4),

or transition tube (5), with retaining ring (7).

f Make certain that retaining ring is properly seated in groove.

f 16.

Seat new lockirg washer (6) on flange of adapter l

f (4), or transition tube (5), depending upon nut j

configuration of arrestor being assembled.

1

1

' PoM 35.000.075 Revision 3 Page 43 17.

Install adapter nut, or transition tube, in housing of support cylinder assembly (21).

Manually tighten nut, or tube, until bottomed against housing.

18. Torque adapter nut er tensition tube to 150 ft.

Ibs. (140 - 160 ft. Ibs.) as follows:

a.

Verify that locking washer (6) is seated flat between housing of support cylinder assembly (21) and flange of adapter nut (4), or transition tube (5).

b.

Install appropriate torque wrench adapter on adapter nut (4), or transition tube (5),

engaging setscrews of adapter with slots of nut or tube, c.

Insert torque wrench in socket of torque wrench adapter.

d.

Using torque wrench as a lever, rotate

, adapter nut (4), or transition tube (5),

clockwise until torque wrench clutch slips, indicating that proper torque has been applied. Document torque on Attachment 3.

19. Remove torque wrench and torque wrench adapter.
20. Using mallet and punch, deform locking washer (6) a minimum bend radius of 60' in three places:

s.

One into housing slot of support cylinder assembly (21) b.

Two into slots of adapter nut (4), or transition tube (5).

21.

If new support cylinder assembly (21) was installed:

a.

Remove drive screws (22) and nameplate (23) from old support cylinder assembly, b.

Steure nameplate (23) to support cylinder assembly with new drive screws.

22.

Remove assembled arrestor from holding fixture.

23.

Slide position indicator tube (3) over telescoping tube of support cylinder assembly (21). Rotate tube until mounting holes in tube and end cap nut (20) are aligned.

POM 35.000.075 Revision 3 Page 44 24.

Coat threads of filister head screws (1) with Loctite retaining compound. Secure position indicator tube (3) to end cap nut (20) with new filister head screws (1) and new flat washers (2).

25.

Install transition tube (5), if applicable.

7.3.6 Document completion of Seciton 7.3 on Attachment 3.

7.4 Paddle Bearing Replacement 7.4.1 To remove a paddle bearing, drive the old bearing from its hole using a brass drive pin and hammer.

7.4.2 To install a new paddle bearing, proceed as follows:

1.

Prior to reinstallation of bearing:

Remove any metal burrs from hole in eyerod.

a.

b.

Check spherical bearing for burrs, dirt, grit or rust. Clean inside and outside of spherical bearing if required.

2.

Center the race of the spherical bearing in the hole. If reinstalling a split race type bearing, position the split on center line toward the threaded end of assembly, see Figure 1 of.

Check to see that the bearing moves freely inside the race.

3.

Place the assembly on the wood block so that the spherical ball of bearing is centered in the hole in the block, see Figure 2 of Enclosure 5.

4.

Use a center punch and ball peen hammer to stake the bearing in four places for small bearings, six places for PSA-35 and 100, on each side approximately 1/16" from the edge of the hole.

Depth of stake should be only enough to retain bearing race in place.

5.

Check to insure bearing totates freely in the race.

7.5 Post Maintenance Inspection, Testing and Restoration 7.5.1 Functionally test the snubber in accordance with Reference 3.1.3.

Document results on the appropriate Attachment.

P0M 35.000.075 Revision 3 Page 45 7.5.2 Ensure that all equipment labels and/or nameplates are reinstalled.

7.5.3 After completion of the work, the Protection Leader /

Work Leader shall sign the Maintenance Order and process the PN-21 in accordance with Reference 3.1.1.

END OF TEXT

(

)

e aw,---w w--h--%

,wm---mw, m

ww-.--

--a


v----

-wy-

-T-w-

,m--

mwn

-m------


m-

+-

E oue1 Page 1 of 3

"^~ ^" "s;'ealan"#"a"^a: Pan' ""-

PSA-l/4 AND PSA-1/2 SNUBBER 37 U

)

{

c,p l

1

POM 35.000.075, Page 2 of 3 071986 PSA-1/4 AND PSA-1/2 PARTS LIST I FIG. & l l

l UNITS l USABLEi l INDEX l

l l PER l

ON l NO.

l PART No.

l 1234567 DESCRIPTION lASSY l CODE i l

l 1

l I

i i

i i

i 3

! l 1801104-05 l ARRESTOR, Mechanical Shock, Model PSA-1/4. I REF l

A l l 1801104-07 l ARRESTOR, Mechanical Shock, Model PSA-1/2.l REF l

B e

1

-1 1 0911100-89 l. RING, Re t a in ing............. l 1

l l

l

-2 l 1801247-01 l. TUBE, Outer...............l 1

l A

l l

l 1801247-03 l. TUBE, Outer...............I 1

l B

l 1

-3 1 0911100-90 l. RING, Re t a in ing............. l 1

l i

1

-4 l 1801900-01 l. ROUSING AND INSERT ASSEMBLY....... I 1

l l

l

-5 l 1801367-01 I. BALL..................l 1

l

}

....l 2

i

}

l

-6 l 0903100-36 l. WASHER.

1 AR l

l

-7 1 0903100-37 l. WASHER,

l 1

-8 1 1801241-01 I. IN ERT IA MAS S.............. l 1

I l

.l 1

l 1

l

-9 l 1801537-01 l. RING, Keeper......

.l 1

l l

l

-10 l 1801612-01 l. SPRING, Capstan..

.l 1

l l

l

-11 l 1801537-01 l. RING, Keepe r..

l

-12 l 1801305-01 l. SPRING, C lutch............. I 1

1 1

.l 1

l 1

f l

-13 1 0903100-50 l. WASHER, Flat l

l

-14 l 1801861-01 l. CARRIER AND SHATT ASSEMBLY, Torque...l 1

l A

l l

l 1801862-01 l. CARRIER AND SHAFT ASSEMBLY, Torque

.l 1

l B

.I 1

l l

1

-15 1 0911100-91 l. RING, Retainer..

.l 1

l l

l

-16 1 1801306-01 l. WASHER, Support............

l

-17 l 1801303-01 l. KEY, Anti-rotation

..l 1

l l

l

-18 1 0911100-88 l. RING, Retaining..

..I 1

l 1

-19 l 1801533-01 l. ROD AND BEARING ASSEMBLY.

..I 1

l A

l i 1801533-01 I. ROD AND BEARING ASSEMBLY....

.l 1

1 E

l

-20 l NAS671-8 1. NUT, Jamb......

.l 1

l l

l

-21 1 MS35335-31 l. WASHER, Lock..

..l 1

l l

l

-22 l 1801311-01 l. BEARING, Pivot

.I 1

I l

..............l 1

l I

l

-23 l 1801367-01 l. BALL............

l

-24 l 1801252-01 l. P.UIDE PLATZ....

.I I

I l

.I 1

l A

I 1

-25 l 1801250-01 l. TUBE, Inner..........

..l 1

l B

l l

l 1801250-03 l. TUBE, Inner....

.l 4

l l

j

~26 1 AN535-2-2 l. SCREW, Drive..

l

-27 l 1801301-01 l. N AMEPLAT E................ l 1

l I

l l

l l

l

5* b $.

902

.k~wE 03"

=> $o *e q" gma

,.OZ g 4

o,Q9995mM TR E

SN If LL a

A r

k B

e n

NAG TN SI HG

\\PR LP

/

1].

CN AP

" \\-

TI CS UR E

. g.

CS T

7-

_LH dI m

LA e

y L

gi n

G R

N E M>

D N

N I

NW A

R I

AY EL F, Y R

BB L

M I B DE R M NS RE AS AS A

\\C S A D

,,sI F.

O R

UT P

EE QF TB H A UU H

O T/

S L

\\LA B

y,

. \\

GN I.

I T RO e

AV

,EMQ,j EI BP E

I 6

n r

[

u-L ACG I N RI O-ER HA PE SB I

POM 35.000.075, Pege 1 of 5 071986 PSA-1, PSA-3, AND PSA-10 PARTS ILLUSTRATION, PARTS LIST, AND INSPECTION LOCATION REFERENCE POINTS MD PSg.30 PARTS II,lUSTwy I

^#

  • l V

1 h *

1 4

35

)

9i I

t M

(?

W}

/.

(-

\\

A 6

sz ft t$,

'f.

11 29 3I At 24 Jc 21 St

.\\

'}

sf I

3 A

i nu g

u l

l

POM 35.000.075, Page 2 of 5 071986 PSA-1, PSA-3, AND PSA-10 PARTS LIST l FIG. & l l

l UNITS lUSABLEi l ITEM l

l l PER l

ON l NO.

I PART NO.

I1234567 DESCRIPTION lASSY l CODE l l

I I

I i

i i

I i

i

! l 1801102-05 l ARRESTOR, Mechanical Shock, Model PSA-1.. I REF I

A l

l 1 l 1801106-05 l ARRESTOR, Mechanical Shock, Model PSA-3.. l REF l

~B l

l l 1801103-07 l ARRESTOR, Mechanical Shock, Model PSA-10.l REF l

C l

l

-1 1 0911100-84 l. RING, Retaining.

.I 1

l A

l l 0911100-80 l. RING, Retaining..

.l 1

l B

l l

l 0911100-96 l. RING, Retaining.

.l 1

l C

l

.I 1

l A

l 1

-2 1 1801232-01 I. COVER, Dust.

.l 1

l B

l l

l 1801260-01 l. COVER, Dust.

.l 1

l C

l l

l 1801217-01 l. COVER, Dust.

l

-3 l AN503-8-4 l. SCREW, Filister head..........l 3

l A

l l

l AN501A10-4 l. SCREW, Filister head..........I 3

l B

i l

l AN501A10-5 l. SCREW, Filister head..........l 3

l C

l

.l 3

l A

I 1

-4 l AN960-8 l. WASHER, Flat

.I l

B,C i l

l AN960-10L l. WASHER, Flat 1

-5 l 1801238-05 I. TUBE, Position indicator

.I 1

l A

I I

i 1801267-05 l. TUBE, Fosition indicator

.I 1

l B

1 l

l 1801216-05 l. TUBE, Position indicator....

.I I

I C

l 1

-6 1 0911100-98 1. RING, Retaining.

.l 1

l A

.I 1

I B

1 l

1 0911100-81 l. RING, Retaining.

l l 0911100-97 i. RING, Retaining.

.I 1

l C

l

.l 1

l A

l

-7 1 1801281-05 I. HOUSING..

.l 1

l B

i l

l 1801274-05 i. HOUSING...

.l 1

l C

l l 1801360-07 I. HOUSING.

l

-8 1 0911100-111 l. RING, Retaining.

.I 1

l A

l l 0911100-110 l. RING, Retaining..

.I 1

l B

l I 0911100-109 I. RING, Retaining.

.I 1

l C

l

.l 1

l A

-9 1 0903100-41 I. WASHER, Flat

.l AR l

B i

I l 0903100-33 I. WASHER, Flat

.I 1

l C

i l

l 0903100-39 1. WASHER, Flat

.l AR l

A l

1

-10 1 0903100-23 I. WASHER, Flat

.l AR l

B l

l l 0903100-33 1. WASHER, Flat

.I 1

l C

l l 0903100-38 l. WASHER, Flat

.I 1

l A

l

-11 1 1801224-03 l

INERTIA MASS.

l l 1801276-01 1

INERTIA MASS..

.l 1

l B

l l 1801205-01 I. INERTIA MASS..

..I 1

l C

l l

-12 1 1801288-01 l. SPRING, Clutch............. l 1

l A

l l

l 1801272-01 l. SPRING, Clutch............. l 1

l B

l l

l 1801201-01 l. S P RING, C lut ch............. l 1

l C

I l

-13 1 0903100-41 l. WASHER, Flat

..I 1

l A

..l AR l

B l

l l 0903100-33 l. WASHER, Flat

..l 1

l C

l l

l 0903100-39 l. WASHER, Flat I

I I

i I

I l

t

P0H 35.000.075, Page 3 of 5 071986 PSA-1, PSA-3, AND PSA-10 PARTS LIST l FIG. & l l

l UNITS lUSABLEi l ITEM l

l l PER I

ON I

l NO.

1 PART NO.

l 1234567 DESCRIPTION l ASSY l CODE i l

l 1

l l

I I

i i

l

-14 l 0911100-99 l. RING, Re t a inin g............. l 1

l A

l l

l 0911100-100 l. RING, Retaining........

.l 1

l B

l l

l 0911100-101 l. RING, Retaining....

.l 1

l C

I l

-15 1 0903100-42 l. WASHER, Flat

.l AR l

A l

l l AN960-716 l. WASHER, Flat

.l AR I

B i

l l 0903100-43 l. WASHER, Flat

.l AR l

B l

l l 0903100-45 I. WASHER, Flat

.l AR l

C l

l

-16 l 1801218-03 l. DRUM, Torque

.l 1

l A

I l

l 1801275-03 l. DRUM, Torque......

.I 1

l B

i i

i 1801206-01 I. CARRIER, Torque.............I 1

l C

l

-17 l 1801538-01 l. RING, Keeper

.I 1

1 A

l l

l 1801539-01 l. RING, Keeper.........

.l 1

l B

l 1

1 1831540-01 I. RING, Keeper

.l 1

l C

l 1

-18 l 1801c13-01 l. SPRING, Capstan.

.l 1

l A

l l

l 1801614 -01 l. SRRING, Capstan..

.l 1

l B

l l

l 1801615-01 I. SPRING, Capstan.

.I 1

l C

l l

-19 l 1801538-01 l. RING, Keeper..

.l 1

l A

i l

l 1801539-01 l. RING, Keeper

.I 1

1 B

l l

l 1801540-01 1. RING, Keeper..

.l 1

l C

l 1

-20 l 1801235-01 I. NUT, Bearing retainer.....

.l 1

l A

l l

l 1801262-01 l. NUT, Bearing retainer.

.l 1

i B

l l

l 1801214-01 l. NUT, Bearing retainer..

.I 1

l C

i l

-21 1 1801236-01 l. RACE Thrust outer (For replacement l

2 i

A l

l l

l order Kit No. 1811041 -01 ).

.I i

i l

l 1811041-01 l. KIT, Thrust bearing (Replacement l REF l

A l

l l

for Part No. 1801236-01)..

.I l

I l

l 1801442-01 l. RACE ASSEMBLY, Outer (For replacement 1

2 i

B i

l l

l order Kit No. 1811042-01)..

.l I

i j

l 1811042-01 l. KIT, Thrust bearing (Replacement l REF i

B l

l l

l for Part No. 1801442-01)..

.l l

l l

l 1801443-01 1. RACE ASSEMBLY, Outer (For replacement l

2 i

C l

l j

order Kit No. 1811043-01).......l l

I l 1811043-01 l. KIT, Thrust bearing (replacement l REF l

C l

l l

for Part No. 1801443-01)..

.l l

l

-22 >*1801493-02 l. BALL (0.1860 inch /4.724 mm diameter) l 8

l A

l l

l l

(Included in Kit No. 1811041-01)...l l

l 1

>*1801493-03 I. BALL (0.1865 inch /4.737 nun diameter) l 8

l A

l l

l l

(Included in Kit No. 1811041-01)...l l

l l

>*1801493-02 l. BALL (0.1860 inch /4.724 son diameter) l 12 l

B i

l l

l

{ Included in Kit No. 1811042001)...l l

l l

>*1801493-03 l. BALL (0.1865 inch /4.737 sun diameter) i 12 l

B l

l l

l (Included in Kit No. 1811042-01)...l l

I

]

F*1801493-02 l. BALL (0.1860 inch /4.724 mm diameter) l 16 I

C i

l l

l (Included in Kit No. 1811043-01)...l I

I l

>*1801493-03 l. BALL (0.1865 inch /4.737 mm diameter)

I 16 I

C I

I l

l (Included in Kit No. 1811043-01) l I

l l

l l

l I

I

POM 35.000.075 Enclosura 2, P:ge 4 of 5 071986 PSA-1, PSA-3, AND PSA-10 PARTS LIST l FIG. & 1 l

l UNITS l USABLEi l ITEM i

l l PER l

ON l

1 NO.

1 PART No.

I1234567 DESCRIPTION IASSY l CODE l

)

l l

l l

I I

J l

-23 l 0911100-82 l. RING, Retaining.............I 1

l B

l 1

-24 l AN565B8H3 l. SETSCREW..

.l 3

l A

i l

l AN565B1032H4l. SETSCREW................l 3

l B

i l

l AN565B1032H31. SETSCREW................l 3

l C

l l

-25 l 1801,860-01 l. PLUG ASSEMBLY, End........... l 1

l A

l l

l 1801858-01 l. PLUG ASSEMBLY, End......

.l 1

i B

l l

l 1801856-01 l. PLUG ASSEMBLY, End......

.I 1

C l

1

-26 l 1801227-01 I. CYLINDER, Telescoping....

.I 1

A l

l l 1801270-01 l. CYLINDER, Telescoping..

.I 1

B l

l 1801211-01 l. CYLINDER, Telescoping.

.l 1

l C

l

-27 l 1801382-01 l. SCREW ASSEMBLY, Ball bearing...

.I 1

l A

i l

l 1801324-01 l. SCREW ASSEMBLY, Ball bearing...

.I 1

l B

l l

l 1801384-01 l. SCREW ASSEMBLY, Ball bearing...

.I 1

l C

l

-28 l 1801287-01 I. KEY, Machine

.l I

l A

l l

l 1801280-03 l. KEY, Machine

.I 1

l B

l l

l 1801298-01 I. KEY, Machine

.l 1

l C

I I

-29 l 1801230-01 l. RACE, Inner thrust (For replacement l

1 l

A i

i l

l order Kit No. 181141-01)..

.I I

l j

l 1811041-01 l. KIT, Thrust bearing (Replacement l REF l

A l

l l

for Part No. 1801230-01).

.1 I

i i

l 1801264-01 l. RACE, Inner thrust (For replacement i

1 l

B l

l l

l order Kit No. 1811042-01).

.I l

i l

l 1811042-01 I. KIT, Thrust bearing (Replacement l REF l

B l

l l

1 for Part No. 1801264-01)

.I i

l l 1801391-01 l. RACE, Inner thrust (For replacement l

1 i

C i

l l

i order Kit No. 1811043-01).

.l 1

l l

I 1811043-01 I. KIT, Thrust bearing (Replacement l REF l

C i

l l

l for Part No. 1801391-01)..

.1 I

I

-30 l MS24694-S1 l. SCREW, Flathead......

.I 3

1 A,B i l

l MS24694-S92 l. SCREW, Flathead...

.l 3

l C

l l

-31 1 MS35790-9 l. WASHER, Lock..

.l 3

l A,B' l

l MS35790-25 l. WASHER, Lock.........

.l 3

i C

1

-32 l 1801234-01 l. KEY, Anti-rotation..

.l I

l A

l I

l 1801265-01 1. KEY, Anti-rotation

.I 1

l B

l l

i 1801212-01 l. KEY, Anti-rotation

.l 1

l C

i 1

-33 l 1801226-01 l. CYLINDER, Support.

.l 1

1 A

l l 1801277-01 l. CYLINDER, Support.

.l 1

l B

l l

l 1801210-01 l. CYLINDER, Support.

.l 1

l C

l l

-34 l AN535-2-2 I. SCREW, Drive

.l 4

l l

l

-35 l 1801301-01 l. NAMEPLATE.............

.l 1

l l

1 I

I I

I I

l

POM 35.000.075 Ercissure 2 Pege 5 of 5 071986 PSA-1, PSA-3 AND PSA-10 INSPECTION LOCATION REFERENCE POINTS CLUTCH AN71 307A710N END PL":

P051710N INDICA 70T

\\

SUFFOA7 PREC1310A CYLINDERLEAD SCREb

\\

\\

INERTIA FA55 ASSEMILY TURE

\\

\\\\

i g" DUST d

[

El

{

w I

j ]lCOVIP

\\

(({ \\ }

T

\\ O<

c x

n s

l l

l

\\ Qi

. " '/

)

I

/

i RECIRCULATINO BALL ASSEMBLY

[

g SPF. ERICA.

TE.*SCOPIN; SUPPORT THRUST BEARINO REAFIN:.

CYLIN;tR m g,gg, CAP 57A.N TOPQ"I 8PRINO DRUM

POM 35.000.075, Page 1 of 4 071986 PSA-35 AND PSA-100 PARTS ILLUSTRATION, PARTS LIST AND INSPECTION LOCATION REFERENCE POINTS PSA-35 AND PSA-100 PARTS ILLUSTRATION

.G

[

e

,l Qh s p-3 3h

/'

7*

s

7 f'e N

/ ".

7 n. )$ V jy.

/_,,

z(

@h/

e a

i i

I s

OJ

i P0M 35.000.075, Page 2 of 4 071986 PSA-35 AND PSA-100 PARTS LIST l FIG. & I l

l UNITS lUSABLEi l INDEX l

l l PER I

ON 4

l No.

l PART NO.

l 1234567 DESCRIPTION IASSY. I CODE i i

l i

I i

l l

l l

l 1

l l 1801112-09 l ARRESTOR, Mechanical Shock, Model PSA-35.1 EF l

A l

l l 1801112-11 l ARRESTOR, Mechanical Shock, Model PSA-35.1 REF l

B l

l l 1801112-13 l ARRESTOR, Mechanical Shock, Model PSA-35. l EF l

C l

l l 1801119-09 l ARREST 0R, Mechanical Shock, Model PSA-100.1 EF l

D I

i 1 1801119-11 l ARREST 0R, Mechanical Shock, Model PSA-100.1 EF l

E l

l l 1801119-13 l ARRESTOR, Mechanical Shock, Model PSA-100.1 EF l

F l

l

-1 l AN501-416-8 l. SCREW, Filister head..........I 3

l A,B,C i l

1 AN501-516-10 l. SCREW, Filister head......

.l 3

1 D,E,F i l

-2 l AN960-416L l. WASHER, Flat..............l AR l A,B,C i l

l AN 960-516L l. WASHER, Flat..............l AR l D.E.F l l

-3 1 1801455-03 l. TUBE, Indicator........

.I 1

l A,B,Ci l

l 1801438-03 l. TUBE, Indicator.............I 1

l D,E,F i 1

-4 l 1801506-05 l. NUT, Adapter..............I I

l A

l l

l 1801506-07 l. NUT, Adapter..............I 1

l B

i l

l 1801507-05 l. NUT, Adapter..............I 1

l D

i l

l 1801507-07 l. NUT, Adapter..........

.l 1

l E

l 1

-5 l 1801480-01 l. TUBE, Transition............I 1

l C

1 l

l 1801478-01 l. TUBE, Transition.....

.l I

l T

i

-6 l 1801497-01 l. WASHER, Locking.............l 1

l A,B,C l

l 1801526-01 l. WASHER, Locking.............l 1

l D,E,F l

-7 l 0911100-80 l. RING, Retaining........

.I 1

l A,B,C l l

l 0911100-106 l. RING, Retaining.............I 1

l D,E,F i l

l

-8 l 1801260-01 l. COVER, Dust...............l I

l A, B,C

  • I l 1801217-03 l. COVER, Dust...............I 1

l D,E, F,

l 1

-9 l MS24665 ';2 l. PIN, Cotter...............l

,I l

l l

l

-10 l AN 310-4 l. NUT, Castellated.......

.I 1

l l

l

-11 l AN960-416 l. WASHER, Flat..............l AR I A,B,C i l

i AN960-416L l. WASHER, Flat 1 AR l

D,E, F,

1

-12 l 18C.58-01 l

INERTIA MASS ASSEMBLY..........l 1

l A, B,C,

I l 1801863-01 l. INERTIA MASS ASSEMBLY..........l 1

l D,E,F i l

-13 1 0903100-45 l. WASHER.................l 1

l D,E,F l

-14 l 1801867-01 l. CARRIER ASSEMBLY, Torque...

.l 1

l A,B,C i l

l 1801865-01 l. CARRIER ASSEMBLY, Torque...

.I I

l D,E,F l l

-15 1 0903100-48 l. WASHER.................I 1

l A,B,C i l

l 1801524-01 l. RING, Wear........

.l 1

l D,E,T l l

-16 l 1801540-01 l. RING, Keeper..............I 1

l A,B,C i l

l 1801611-01 l. RING, Keeper..............l 1

l D,E,F l 1

-17 l 1801615-01 l. SPRING, Capstan......

.l 1

l A,B,C l l

l 1801617-01 l. SPRING, Capstan.........

.l 1

l D,E,F i l

l l

1 1

1 l

i PoM 35.000.075, Page 3 of 4 071986 PSA-35 AND PSA-loo PARTS LIST I FIG. & I l

l UNITS l USABLE l l DRDEX l

l l PER I

05 l

l NO.

I PART NO.

I1234567 DESCRIPTION lASSY. I CODE l l

l i

l i

i I

-18 l 1801540-01 I. RING, K ee pe r.............. I 1

l A,B,C l l

l 1801611-01 l. RING, K. pe r.............. I 1

I o,E,r i l

-19 l 1801546-03 I. C AP AS S EMBLY, End............ l 1

l A,B,C!

I i 1801545-03 I. C AP ASS EMBLY, End............ I 1

l D,E,F l 1

-20 1 1801451-03 I. Nur, End cap..............I 1

1 A,B,C i l

l 1801432-03 I. nut, End cap..

.........I 1

1 D,E,r i

-21 l 1801866-01 I. CYLINDER ASSEMBLY, Support.......l 1

l A,B,C i l

l 1801864-01 i. CYLINDER ASSEMBLY, Support.......l 1

l D.E.T I l

-22 l AN535-2-2 I. SCREW, Drive..

........l 4

l l

1

-23 1 1801301-01 I. NAMEPLATE................l 1

l l

1

-24 l 1801201-01 I. SPRING, Clutch.............l 1

l A,B,C l l

l 1801409-01 l. SPRING, Clutch.............l 1

l D,E,F l i

I I

I I

I l

l

-. ~.. - - - - - - - - -.,

PoM 35.000.075 Enclesure 3 Pege 4 of 4 071986 PSA-35 AND PSA-100 INSPECTION LOCATION REFERENCE POINTS l

CLL'TCn mAMEPLATE (23).SPRINO 3

I

$jIC^IOK Top o'.*t, As Y 9) car:r f

Ntteu

.ta s,;,

<=>

t g~.

__ _2

[

_M W d.

4 O

{

sik sinsrs

=

l-5 % CaFitF E

l 7y 1

^

BEAP!hO TELESCOPING INERTIA CYLINpgp t nAss.

SHtll SUPPORT PINION CYLIN:rg (21)

CES l

I PON 35.000.075 j

r Enclasura 4, Peg 2 1 cf 3 071986 PSA-1/4, PSA-1/2, PSA-1, PSA-3, PSA-10, PSA-35 AND PSA-100 SPECIAL TOOLS AND FIXTURES PSA-1/4 AND PSA-1/2 i

DISASSEMBLY TOOLS Adaptor, Jam Nut, Part No.180lI04-AT-2-1.... Pacific Scientific Pivot Bearing Driver, Part No. 1801104-AT-2-2.. Pacific Scientific Pliers, Needle Nose..

.......... Commercially Available Pliers, Truarc, Part No. 03 and 05........ Waldes Kohinoor Inc.

47-16 Austel Place Long Island City, NY 11101 ASSEMBLY TOOLS Pivot Bearing, Driver, Part No. 1801104-AT-2-2.. Pacific Scientific Adaptor, Jam Nut, Part No. 1801104-AT-2-1.... Pacific Scientific Torque Wrench, Part No. 6003........... Torvaal 524 Washington St.

Chagrin Falls, OH 44022 Pliers, Truarc, Part No. 01, 03 and 05...... Waldes Kohinoor Inc.

47-16 Austel Place Long Island City, NY 11101 i

Bearing, Part No. 1801532-01........... Pacific Scientific l

Magnet Tool, Part No. 1801104-MIT-2....... Pacific Scientific l

l e

r 70M 35.000.075 Exc1csuro 4, P:gs 2 of 3 071986 PSA-1, PSA-3, AND PSA-10 DISASSEMBLY TOOLS Adaptor, Torque Wrench, End Plug:

Part No. 1801102AT9 (Model PSA-1)...... Pacific Scientific Part No. 1801106AT9 (Model PSA-3)...... Pacific Scientific Part No. 1801103AT9 (Model PSA-10)..... Facific Scientific Fixture, Holding:

Part No. 1801102AT5 (Model PSA-1)...... Pacific Scientific l

Part No. 1801106 AT5 (Model PSA-3)...... Pacific Scientific Part No. 1801103AF1 (Model PSA-10)..... Pacific Scientific Part No. 1801103AT4 (all).......... Pacific Scientific Pliers, Truere:

Part No. 02................. Waldes Kohinoor, Inc.

Part No. RE-015 47-16 Austel Place Part No. S67, Heavy Duty Long Island City, NY 11101 ASSEMBLY TOOLS Adaptor, Torque Wrench, End Plug:

Part No. 1801102 AT9 (Model PSA-1)...... Pacific Scientific Part No. 1801106AT9 (Model PSA-3)..

. Pacific Scientific Part No. 1801103AT9 (Model PSA-10)..

. Pacific Scientific Fixture, Holding:

Part No. 1801102AT5 (Model PSA-1)..

... Pacific Scientific Part No. 1801106AT5 (Model PSA-3)..

. Pacific Scientific Part No. 1801103AFI (Model PSA-10)..

. Pacific Scientific Gauge, Co/No-Go:

Part No. 1801102GA2 (Model PS A-1)..

. Pacific Scientific Part No. 1801106GA2 (Model PSA-3)..

... Pacific Scientific Part No. 1801103G42 (Model PSA-10)..... Pacific Scientific Fliera, Truarc:

Part No. 02................. Waldes Kohinoor Inc.

Part No. RE-015 (Model PSA-1) 47-16 Austel Place Part No. RE-018 (Model PSA-3) long Island City, Part No. RE-031 (Model PSA-10)

NY 11101 Part No. 867, Neavy Duty

POM 35.000.075, Page 3 of 3 071986 PSA-35 AND PSA-100 I

DISASSEMBLY TOOLS Adaptor, Torque Wrench, Adaptor Nut and Transition Tube:1801112AT8 (Model PSA-35)..... Pacific Scientific Part No. 1801119AT8 (Model PSA-100)..... Pacific Scientific Part No.

Fixture, Holding:

Part No. 1801112AT27 (Model PSA-35)..... Pacific Scientific Part No. 1801119AT26 (Model PSA-100)..

. Pacific Scientific Pliers, Truarc, Part No. 0500.......... Waldes Kohincor, Inc.

47-16 Austel Place Pliers, Truarc, Part No. S6700 Long Island City, NY 11101 ASSEMBLY TOOLS Adaptor, Torque Wrench, Adaptor Not and Transition Tube:

Part No. 1801112 AT8 (Model PS A-35)..... Pacific Scientific 1801119AT8 (Model PSA-100)..... Pacific Scientific Part No.

Adaptor, Torque Wrench, End Cap Nut:

Part No. 1801112 AT10 (Model PSA-35 )..

. Pacific Scientific Part No. 1801119 AT10 (Model PS A-100).... Pacific Scientific Fixture, Holding:

Part No.1801112 AT27 (Model PSA-35)..

. Pacific Scientific Part No. 1801119 AT26 (Model PSA-100)

. Pacific Scientific l

Pliers, Truare, Part No. 0500.......... Waldes Kohinoor Inc.

Austel Place Pliers, Truarc, Part No. S6700.........

47-16 Long Island City, NY 11101 l

l t

l l

l l

l

.a I

P0H 35.000.075 Exclosure 5, Pcge 1 of 1 081386 PADDLE BEARING STAKING STAKE AT 4 POINTS (6 POINTS FOR LARGE BEARINGS) EACH SIDE OF POSITION AS SHOWN SPHERICAL BEARINC

\\!

SNUSSER END CAP 3

,g NOTE:

,"1,arge Bearins" applies to PSA-35

/

and PSA-100 Snubbers.

[

f A,.

O i

STAKING TIGURE I SPHERICAL BEARING SNUBBER END CAP

\\

.(\\

l

'N.I.l!.h.k,

{

l 1

1 BLOCK WITH CENTER HOLE TO CLEAR SPHERICAL BALL OF BEARING STAKING TIGURE 2

-,----,-,,,,--,.--,1--w---

---.,_n

\\.. (

' +,

s P0M 33.000.075

/

Attachnent 1, P ge 1 cf 3 081386 PSA - 1/4 and PSA - 1/2 i

MAINTENANCE DATA SHEg"\\

\\

(

I C

Serial No. >

Model No.

\\>

PN-21 }do. '

PIS No.

b' l

Prerequisite s-Met

\\

Sgtnat,ur,e /Date s

+

Ac'cepta rr s M&TE Verified by/

Step No.

Description Data Crit'eria Serial No.

Date 7.1.3.2.s outer Tube Insp.

Sat;__

Bore of outer' s

  • Unsat tube shall be
  • k round and nat :

i interfere with' outside diameter of inner tube.

NA:

/

[

7.1.3.2.b Torque Carrier /

Shaft Assy Insp.

%'N 1.

Visual Sat Ball socke* must

  • Unsat not show evidence of dac. age - or be '

is deforup;'No 3

thread fora dam-t age allowed.

NA

/

s.

(

2.

Sisensional

,A Run oup shall not exceed

/

)

O.005 in. '

1 t

\\

3 7.1.3.2.c Rod and Bearing Ass). Insp.

.~'

1.

Bearing Visual Sat Bearing shall g

  • Unsat rotate am?othly without binding. _ NA l'g;_'

u 2.

Thread Visual Sat No evidence of

  • Unsat wear allowed.

MA

/

\\

N

3., Dimensional i

Sts11 be concentric with-

/

in 0.005 inch.

p

\\

)

  • All discrepancies and/or corrective action shall be specifically described in the s

?

Remarks Section.

/

i

~

5 l

t i

\\

W POM 35.000.075, Page 2 of 3

081386

\\

PSA - 1/4 and PSA - 1/2 MAINTENANCE DATA SHEET FN-21 No.

i 3

Acceptance M&TE Verified by/

S crte N o '. -

Description Data Criteria Serial No.

Date

%,,j,v:

'(

7.1.3.2.d Inner Tube Assembly i.

1.

. Deform. Visual Sat Surface of inner

  • Unsat tube shall be round and not to interfere with

(

)~

inside diameter of outer tube.

NA

/

L

')

,I s 2.

We'ar Visual Sat No evidence of

I

,}

  • Unsat wear allowed.

NA

/

i.

r 7.1.3.2.e Nameplate Sat _

Nameplate shall

  • Unsat _

be securely attached by drive screws.

NA

/

s 7.1.5.30 Jam Nut Torque '

Torque Jam Nut to 24 to 26 in. Ibs.

/

/

t N

7.1.5.34 22 in. pounds N

c.

Rear Bracket or Extention Ti.be '

(20 - 24 in. Ibs.)

['Y'ef

/

Torque, h

7.1.6 Overhaul of Models Sat PSA-1/4 and PSA 1/2 *Unsat _

Completed NA

/

I

) i \\ j..

){

,i$

\\

/

1

\\

'y y

r h*

/

\\.

  • All discrepancies and/or corre'etive action shall be specifically described in the i

)

Remarks Section.

?,.

~

t k

.,f,t t,

s

',n

's s

1 s

v POM 35.000.075 Attechnent 1, P:ga 3 of 3 J)' '

081386 v '.

PSA - 1/4 and PSA - 1/2

-e i) i MAINTENANCE DATA SHEET e

P PN-21 No.

f,)#

Test Equipment Serial No.

Calibration Due Date l l {.,

i l

4 REMARKS

's[

Completed by:

i Nacle (P: int )

Signature Initials Employed by Date

/

Reviewed by Foreman

/

Date i

/

Approved by Maintenance Engineer

/

Date or Delegate

\\-

i t

  • T l'

l POM 35.000.075, Pcge 1 of 3 081386 PSA - 1. PSA - 3, and PSA - 10 h

MAINTENANCE DATA SHEET Serial No.

Model No.

PN-21 No.

PIS No.

/

Prerequisites Met Signature /Date Acceptance h&TE Verified by/

Step No.

Description Data Criteria Serial No.

Date 7.2.3.2.s Position Indicator Sat Bore of position

  • Unsat Indicator tube Insp.

shall be round and not interfere with outside dia-meter of support support cylinder.

NA

/

7.2.3.2.b End Plug Assembly Sat _

Bearing shall

  • Unsat rotate smoothly

- 7thout binding.

) ating shall securely installed. NA

/

7.2.3.2.c Support Cy1 Assy Sat Telescoping Operation Check

  • Unsat cylinder shall extend and re-tract through full stroke with-out hesitation or binding.

NA

/

7.2.3.2.d Nameplate Sat Nameplate shall

  • Unsat be securely attached by drive screws (34).

NA

/

7.2.5.17 End Plug Torque Torque End Plug (25) to 50 inch pounds (40 - 60 in. Ibs.)

/

Model Torque in.lbs.

7.2.5.20.c Setscrew (24) Torque PSA-1 10 to 20 in.lbs.

PSA-3 15 to 25 in.lbs.

PSA-10 15 to 25 in.lbs.

/

  • All discrepancies and/or corrective action shall be specifically described in the L

Remarks Section.

6

P0H 35.000.075 Attcchsent 2, Pags 2 of 3 081386 PSA - 1, PSA - 3, and PSA - 10 MAINTENANCE DATA SHEET PN-21 No.

MTE Verified by/

Acceptance Step No.

Description Data Criteria Serial No.

Date Model Torque in. Iba.

7.2.5.25.

c.

Rear Bracket or PSA-1 40 to 50 in.lbs.

Extention Tube PSA-3 110 to 130 in.lbs.

PSA-10 420 to 460 in.lbs.

Torque 7.2.6 Overhaul of models Sat PSA-1, 3, and 10

  • Unsat Completed NA

/

Test Equipment Serial No.

Calibration Due Date REMARKS l

  • All discrepancies and/or corrective action shall be specifically described in the Remarks Section.

POM 35.000.075 Attcchment 2, P:ge 3 of 3 081386 PSA'- 1, PSA - 3, PSA - 10 MAINTENANCE DATA SHEET PN-21 No.

1 Completed by:

Name (Print)

Signature Initials

% 1oyed by Date

/

Reviewed by Foreman

/

Date

/

Approved by Maintenance Engineer

/

Date i

}

or Delegate i

^ ~ ' - -

POM 35.000.075 Attechnent 3, P gs 1 cf 3 081386 PSA - 35 and PSA - 100 MAINTENANCE DATA SHEET Model No.

Serial No.

PIS No.

PN-21 No.

Prerequisites Met

/

Signature /Date Step Acceptance M&TE Verified by/

No.

Description Data Criteria Serial No.

Date 7.3.3.2.a Inertia Mass Assy (12)

Sat Spring shall be (Clutch spring)

  • Unsat___

securely install-ed.

There shall be no deforma-nation.

NA

/

(Shell)

Sat No cracks, breaks

  • Unsat or gouges shall be evident.

NA

/

i (Hub )

Sat ___

Hub shall be

  • Unsat securely in place. There shall be no scoring on hub shaft.

NA

/

7.3.3.2.b Torque Carrier Assy (14)

Sat ___

Bearings shall

  • Unsat___

rotate smoothly, Bearings shall be securely l

installed.

NA

/

7.3.3.2.c End Cap Assy Sat Bearing shall

  • Unsat___

rotate smoothly without bind.

No evidence of elongation or damage. None allowed.

NA

/

  • All discrepancies and/or corrective action shall be specifically described in the Remarks Section.

(

POM 35.000.075 Attcchment 3, Prga 2 of 3 081386 PSA - 35 and PSA - 100 MAINTENANCE DATA SHEET PN-21 No.

M&TE Verified by/

Acceptance Step Wo.

Description Data Criteria Serial No.

Date 7.3.3.2.d Position Indicator Tube (3)

Sat Bore of position

  • Unsat indicator tube shall be round and not interfere with outside dia-meter of support cylinder.

NA

/

7.3.3.2.e Support cyl Assy(21)

Sat Telescoping

  • Unsat cylinder shall extend and re-tract through full stroke with-out hesitation or binding.

NA

/

7.3.3.2.f Nameplate Sat Nameplate shall

  • Unsat be securely attached by drive screws (22).

/

ft. Ibs.150 ft. Ibs.

7.3.5.6.c End Cap Assy.

/

(140 - 160)

Torque 7.3.5.18.d Adapter Nut (4) or transition 150 ft. Ibs,

/

tube (5) Torque (140 to 160) 7.3.6 Overhaul of models Sat PSA - 35 or 100

  • Unsat completed NA

/

  • All discrepancies and/or corrective action shall be specifically described in the Remarks Section.

POM 35.000.075 Attcchment 3, P:gs 3 cf 3 081386 PSA - 35 and PSA - 100 MAINTENANCE DATA SHEET a

l PN-21 No.

Test Equipment Serial No.

Calibration Due Date REMARKS l

Completed by:

Name (Print )

Signature Initials Employed by Date Reviewed by

/

Forecan

/

Date Approved by

/

Maintenance Engineer

/

Date or Delegate l