Enclosure to NRC-98-0088 ENCLOSURE-PART1 PROPOSED TECHNICAL SPECIFICATION PAGE MARK-UP INCLUDED PAGE:
3.5.1 l
1 9906030313 990528 I
PDR ADOCK 05000341 P.
PDR,,
r L.
3/4.5 EMERGENCY CORE COOLING SYSTEMS 3/4.5.1 ECCS, OPERATING LIMITING CONDITION FOR OPERATION 3.5.1 The emergency core cooling systems shall be OPERA 8LE with:
a.
The core spray system (CSS) consisting of two subsystems with each subsystem comprited of:
1.
Two OPERABLE CSS pumps, and 2.
An OPERABLE flow path capable of taking suction from the suppression chamber and transferring the water through the spray sparger to the reactor vessel.
i E e S' E b.
The low pressure coolant injection (LPCI) system of the residual heat gigg; removal system consisting of two. subsystems with each subsystem g; t a g comprised of:
yuE' E B El' 1.
Two OPERABLE LPCI (RHR) pumps, and 4gcg
% *u i a 2.
An OPERA 8LE flow path capable of taking suction from the g,cgg suppression chamber and transferring the water to the reactor u," u,
vessel.***
.g*g5 g
8%EE The high pressure cooling injection (HPCI) system consisting of:
g >g c.
E-o 1.
One OPERABLE HPCI pump, and g E $,*
%"24 2.
An OPERABLE flow path capable of taking suction from the c;a: a-suppression chamber and transferring the water to the reactor. 9Ju vessel.
ag,;
=E - -
d.
The automatic depressurization system (A05) with at least five Eua" OPERABLE ADS valves.
"o3g APPLICABILITY:
OPERATIONAL CONDITION 1, 2* ** I and 3* **.
E.onasf
- t~"
,5824
-u f E.
22 C
- The HPCI system is not required to be OPERABLE when reactor steam done g,ggg pressure is less than or equal to 150 psig.
8g-
e gmg5g 0**";rr 7:=t;t Of = LM! initi:ti:: :i;ni,
- nt
- r
- : tic: i: r:;ind t:
ag;,o
=="y :;= th: t:n: :=ti= n?n; :: f= ilit:t; LPc! :;: n ti:, if th; g ggg LPCI y:t= i: in th: ""P. :h:td:= =: ling =d: :f :;gr:t!= ;:-
a,c,g c 5;=ifi=ti= 3.t.0.1.
,See Special Test Exception 3.10.6.
ggggi
"""a*
O FERMI - UNIT 2 3/4 5-1 O
7
- ~,
l l
l Enclosure to NRC-98-0088 ENCLOSURE - PART 2 PROPOSED TECIINICAL SPECIFICATION REVISED PAGES INCLUDED PAGE:
3.5.1 i
l 1
l l
.____._.________________a
(
t ;
I l
3,. 5 EMERGENCY CORE COOLING SYSTEMS
~
3/4,5.1 ECCS - OPERATING LIMITING CONDITION FOR OPERATION 3.5.1 The emergency core cooling systems shall be OPERABLE with:
a.
The core spray system (CSS) consisting of two subsystems with each subsystem comprised of:
1.
Two OPERABLE CSS pumps, and 2.
An OPERABLE flow path capable of taking suction from the suppression chamber and transferring the water through the spray sparger to the reactor vessel.
b.
The low pressure coolant injection (LPCI) system of the residual heat removal system consisting of two subsystems with each subsystem comprised of:
1.
Two OPERABLE LPCI (RHR) pumps, and 2.
An.0PERABLE flow path capable of taking suction from the suppression chamber and transferring the water to the reactor vessel.***
c.
The high pressure cooling injection (HPCI) system consisting of:
1.
One OPERABLE HPCI pump, and 2.
An OPERABLE flow path capable of taking suction from the suppression chamber and transferring the water to the reactor
- vessel, d.
The automatic depressurization system (ADS) with at least five OPERABLE ADS valves.
APPLICABILITY:
OPERATIONAL CONDITION 1, 2* ** # and 3* **.
- The HPCI system is not required to be OPERABLE when reactor steam dome pressure is less than or equal to 150 psig.
- Low pressure coolant injection (LPCI) subsystems may be considered OPERABLE during alignment and operation for decay heat removal with reactor steam I
dome pressure less than the Residual Heat Removal (RHR)_ cut-in permissive I
pressure in OPERATIONAL CONDITION 3, if capable of being manually realigned I
and not otherwise inoperable.
l
- See Special Test Exception 3.10.6.
FERMI;- UNIT 2 3/4 5-1 Amendment'No.