Forwards Suppl to Application for Amend to Facility Operating Licenses DPR-29 & DPR-30 Re TS Upgrade Program
ML20113C343
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 06/25/1996
From: Kraft E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20113C344 List:
References
ESK-96-124, NUDOCS 9607010146
Download: ML20113C343 (2)


Text

f I

Commonw calth lilison Compan)

Quad Citics (.cncrating Nation

'2lilu 206dt Asenue Nortti Cordova, 11.61212-9710 ret un6s+2241

- ESK-96-124

(

June 25,1996 U. S. Nuclear Regulatory Commission Attn: Document Control Desk i-Washington, D.C. 20555 l

Subject:

Quad Cities Nuclear Power Station Units 1 and 2 l

Supplement to Application for Amendment to Facility Operating Licenses DPR-29 and DPR-30, Appendix A, Technical Specifications for the Technical Specifications Upgrade l

Program (TSUP)

' NRC Docket Nos. 50-254/265

References:

(a) P. Piet letter to T. Murley (U. S. NRC), dated March 26,1993, i

(b) P. Piet letter to U.S. NRC, dated November 14,1995 (Comed submittal regarding TSUP clean-up).

(c) P. Piet letter to U.S. NRC, dated May 10,1996.

(d) P. Piet letter to U.S. NRC, dated June 14,1996.

The purpose of this letter is to revise the package submitted in Reference (a), Reference (b),

Reference (c) and Reference (d). A summary and Comed's assessment of the proposed changes are provided below. The marked-up pages are provided in Attachment A, and the retyped pages are provided in Attachment B.

Comed proposes to change the required load ranges for the Emergency Diesel Generator (DG) monthly surveillance (TSUP Surveillance Requirement (SR) 4.9. A.2.d), the 18-month endurance run (24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> surveillance) (TSUP SR 4.9.A.8.h) and the 18-month Load Reject test (TSUP SR 4.9.A.8.c) from a range of 2375 to 2500 kW (2625 to 2750 for 110% portion of 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> test) to a range of 2470 to 2600 kW (2730 and 2860.for 110% portion of 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> test). Comed also proposes to change the 2000 hour0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> rating limit from 2850 kW to 2860 kW. At the time of the original TSUP submittal (Reference (a)), the Final Safety Analysis Report (FSAR) stated the DG design load as 2500 kW and the 2000 hour0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> rating as 2850 kW. During the Updated Final Safety Analysis Report (UFSAR) rebaseline project, the numbers were changed to 2600 kW and 2860 kW, respectively, to clarify a discrepancy between the FSAR and the ectual phnt configuration. This change to the TSUP requirements will allow the Technical Specifications to reflect the design. Because this change is consistent with the plant design, this change is acceptable.

/f'g('/

1 I

~

9607010146 960625 PDR ADOCK 05000254 P

PDR A Unicom Company i -

--u-

ESK-96-124 USNRC June 25,1996 The proposed supplemental changes have been approved by Commonwealth Edison's (Comed)

Onsite and Offsite Review in accordance with Company procedures. Comed requests that the proposed changes be approved as submitted to become effective upon completion of the entire TSUP project.

Please direct any questions or comments concerning this letter to Nick Chrissotimos, Regulatory Assurance, at (309)654-2241, extension 3100.

Sincerely,

$. lbA E. S. Kraft Quad Cities Site Vice-President

Attachment:

A. Marked-Up TSUP Pages B. Retyped TSUP Pages cc:

H. J. Miller, Regional Administrator - RIII R. M. Pulsifer, Project Manager - NRR C. G. Miller, Senior Resident Inspector - Quad Cities Office of Nuclear Facility Safety - IDNS D.C. Tubbs, MidAmerican Energy Co.