Forwards Responses to Category I Target Date Items Re Structural/Geotechnical Review,Per 840110-12 Meeting Agreements
ML20080B940
Person / Time
Site: Hope Creek 
Issue date: 01/26/1984
From: Mittl R
Public Service Enterprise Group
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 8402070326
Download: ML20080B940 (52)


Text

f v

19 9

PS G Company Pubhc Serwce (Bectnc and Gas i

80 Park Plaza, Newar k, NJ 07101/ 201430 8217 MAIL ING ADDRESS / P.O. Box 570, Newark, NJ 07101 Robert L. Mitti General Manager Nuclear Assurance and Regulation January 26, 1984 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20014 Attention:

Mr. Albert Schwencer, Chief Licensing Branch 2 Division of Licensing Gentlemen:

HOPE CREEK GENERATING STATION DOCKET NO. 50-354 NRC REVIEW OF STRUCTURAL /GEOTECHNICAL 'IOPICS Pursuant to the agreements reached at the meetings held on January 10, 11, and 12, 1984, to review HCGS structural /geo-technical topics with the NRC, attached is one (1) set of responses to those items denoted as Category I target date.

A listing of the attached Category I target date items, broken down by date of meeting, is as follows:

Meeting of January 10, 1984:

Items B.6, B.8, B.9, and B. ll Meeting of January 11, 1984:

Items A.7, A.10, A.11, A.15, A.17, B.1, B.2, B.3, B.4, B.5,B.6, B.7, B.8, B.9, B.12, and B.13 Meeting of January 12, 1984:

Items A.1, A.2, and A.3 (Items C.1, C.2, C.4, C.5, C.6, and C.7 will be included as part of Amendment 4 to the FSAR)

In addition, please note that four (4) advance sets of these responses were transmitted to D.

Wagner via Federal Express on January 23, 1984.

8402')70326 840126 gDRADOCK05000 pgl The Energy People g

4912 (4Vi 7 83

4-Letter to Mr. Albert'Schwencer 1/26/84 Should.you-have.any questions in this regard, do.not hesitate to contact us.

Very truly y/ours,

[7' R. L..Mittl

-General Manager -

Nuclear Assurance and Regulation JES:db

Attachment:

Resolution of NRC Comments on Structural /Geotechnical Topics CC:

D.

H.. Wagner (w/ attach.)

USNRC Licensing Project Manager OQ 14 01/02-A

w 4$

R00pon30 to NRC Audit Meeting Date:

Ja nua ry 10, 1984 Question No.:

B.6 QUBSTION:

Provide tabulations of shear moduli used for:

l soil column model

. design basis model

RESPONSE

The attached Figure 1 shows a typical soil column used for the deconvolution analysis.

The attached Figure 2 shows a schematic representation of the soil model used for the soil-structure interaction analyses.

The attached Table 1 shows a comparison of the final iterated shear moduli used in the deconvolution analysis (which corresponds to free-field conditions )

and the final iterated shear moduli used in the SSI analysis.

The column

  • soil f rom which the SSI values have been extr.:ted corresponds to a location underneath the reactor building, as indicated in Figure 2.

Note that the data provided corresponds to layers 20 to 53 in the soil column 's model.

The corresponding element numbers at similar depths underneath the reactor building are elements numbers 804 to 837.

l B.6-1

'9 4

LAYER #

g, 3,,.

WlF1111t=1 1 0 3' g,,,

CL(F111)k=3 304' U. 87' t 9 5' IL-CL(F111)k=3 g, p, 203

(

U. 71' atver tottom 2 9 4.5' Sand. k=2 D. 62' Etrkwood Clay.

p, y, kN 294' D. 4' 2 9 3' Free Fleid D. 40' 4 9 2.5' D. E' gg 8 9 5' Vincentown Sand.

k=2 D. 10 SO 9 9' E1. 100' Various Sands.

15 9 12.5' k=2 U. 300',n.wiewwwwwwartmwwwast awwin FIGURE'1 IDEALIZED FREE-FIELD SOIL COLUNi FOR DECONVOLUTION (POWER BLOCK AREA HORTH-SOUTH DIRECTION)

cs w ned Area

~ ~ "~g on...u ny ou wsay, v..

+, e-~

mi n.)

.. c. )

  • i o

.,,,,,,yf

'"' 7)

N ',,.:,,a c'") '.',._

  • i

,,i,

'N a M

' P' 6,,,, j C,,:'.

G rd

!;;'l'

%% q,.,

.J

,;f' N,,g r..c=>

n4% p~~ t.,

., f

,..\\..r-2 t

a_

,p j

.s

. -iX.

l N '*.

,,,,,, m i ri un

c. <,'.) -m>

r,a

,,,, ~

l i

w m

.y

.4,..,

r-,

os m

S k.

O O

O 8

O O

O OO O

8 O

O 6

6

~';

l j

m, l

I,'

C* C, * !.,,@ FFGPJyGP~h".?4"EP,F8~5 % "WP IA #

  • p i

l l

GL;_.x. L. _h?. 319_..!@.. e.. G..c2 '. ua 6?_..f D %::g.3,C " O da _6D o

ca

._dD

,1

/g04 Engineel-ing

/

Backfil'1 i

[

l-I j

  1. 05

/

[

[

l i

l i

/

N D'l j

t I

i 51W0

43 j

l I

I

/

1 04 Goudf3 N3 l

l l'

l

^ N/

. __ en cor :

l

e i

Column for i

"""^ ' -5.. '.. - I '

l which values of shear moduli are

./

shown in Table 1

'/

/

[

l j

j l

l 1

i i

l I

i l

DESIGN VERIFICATION 1 1 i

'i l

cm P.l i t.

I /

l !

i i

Joa nn m.. n e

j l

t

-/

l lc tces ho de_w.n ir., !

l i

c-us;:4 %

I in 'q_

r l/,

i lFS

,j p

ut e/#g l

i 8',

s I

}

~e g ' '<,),+ g og g.. ;3 '",,3, y,a g.-' 'g-j l"g. 'g 4g "*yg"g_.

-*g__"g

- ~p f"w,.6 *g'~g 'gj e3 '"g "g p'go. e B :

3

.4a

  • ts P e i ><a ! i a "<.T'. => ' o ' < i W o <,a :3 y' ? %'"< m.mh... 3.. 49_. Le

~

FIGURE 2: S0ll-STRUCTURE INTERACTION MODEL (SCHEMATIC)

l 4

e

e..n n.n n. e n. n..m e. d. A. n. d o m m.m.m m m. m m m m. n. d e m,n,d w o, m.

o e.ge

.o,

.e ea e# 4 0 0 9 9 e 9 4 0 4 0 9 0 0 0 6 0 0

  • 4 4 0 9 8 9 e ee e e s y w w t.4 w w w w e # w q.J i6sog W w w w we.aw w wIaw we.#eawt.Jetaf W w g

g d 4 Pt M 89trtdP4e@PeetodW@Meeeed94 4 O po N N ** se @

e e mi art O e c.P M e p F P M d e Pe P e e e e tp @ c 4 4 ** e J A ** ao P e N en eeee w

9atn e p 3 4emgee eseN M ggrbd**ec se em @ p @ e e e e e e e M e4 W't 89 M 8'b si 89 e e e e e e e e e e'n O ** N N g

@ @ 6 J9 g

ee e e e e ee e o e e e e e o e e ee e e e o e e o e e e* e e #

egGOOOGOWeGWGO9e9eeOOeOOemOOOOOOeO es.

b 44 P'-'"

T O

E O

N w=

e o ee e o ee e ee e eeo e e e ee oe e o e * *

  • e oe # *
  • ng c c ga.89 eSWSfftd @ eW9e G N 3 Oft 9.W9PseO N esie eseseM d P P 3o e e o se e e m. ** e d om e e. 4 se.P.e en me c F R Me e t P. e G.G.e o O O p

trl ** e P P 4.

dea medooMee eee

.=

P a. se se N N N M ce M N 89 M M M

  • ew

'D e a

e e M 89 89 M 89 89 89 M M M *

  • e *
  • e t==0

&D C

I O

x

.e e e m m.e. u n e e e m e e. ~ n n e e d ~ e r o -o n n e e * ~

g g

. o

.-------~~nnennununneMMMnMMn w

eeeeeeeeeeeeeeaeaeeeaeeeaeeeeaeeae W

i CC Wm ZZ t

MO Ob

{

W *--e ra

      • Z Ct; O wy 8

N

&D

=C ZQ

  • -* Z

.,,~,

.e

.e

_e

u. Oc e e = e e e e o a o.c. e e, o e,n e,, a,,

,e a,.,..,.,3 c,.,.,

n e,

ee e ee oe ee: e ee e

i.#ww w w ww=#wawwwww wi.ewww,w waw

,saw,.,,w aw,w, g

z e 8' N d ** O N O b e d 8* @ m @ N O W* O M d e h e rg N es at c 9m P e p Cd e

e P " O" @e O P e P P ** E @ e ce g= ano e e se o,.p'b M, og,9 N, h m.e N N 89 e, em,. e e se P e S O e 9

  • 5 e d8 W

w 3d e og p g p

,f 4s g p g,,.

,3

,,,,q g

e

  • 4 e c e e e e e e e e e, M c as e M e e e e e e e e e e e c c,., a n

i e e e e e e e oe e e e e e e e eee e e e e o e o e o e e e e e l

.e e e # O o e e e o o e o e o o i,.,, a o e 3 o r. e oeoe aaao6 w es L') La.J e-e y h'

d CC "O

  • C 6 CL EE

{

OO U La CE o

3 w **

ee ee ee eoe,,e e e

,,e

, e e,

e, e,,,

e e a e o e ce e d = e.

  • era e14 e ce e e e e ce e,.e. e.. m n e, o,., P e eaw ed ee m e e e u o e e4== a q q JV O

"e a '

d O if9 P, e 4 e e e.re a erPeeo

  • * * = = * -== n a w n -t at c we e M e,,d,.
n. e. e

.J.e, *= c **we e es e es e M M wies e M,.,

ee

. eeeee..

na U

8=

,_j CO KC O

g M

e w

e a es M e e d e. e e.. c e e eee.ee ceMeed=ee u,

N M N N 848 N et M M M M W9 M M 89 889 8'l M M W9 e e e e e e e e e e gg c g9 go 3"e i

me

Responso to NRC Audit Meeting Date January 10, 1984 Question No.:

B.8 QUESTION:

Provide calculation showing how torsional stif fness was established for the reactor building.

RES PONSE:

A typical calculation of evaluating torisonal stif fness is provided in the attachment.

This calculation is performed for beam element between nodes 101 and 294 of Figure 1.

The procedure consists of assigning a number to each wall contributing to the torsional stif fness of the system.

(This is shown in Figure 2).

For each wall, axial and shear areas are computed.

The total shear area in a given direction is computed by adding the contribution of each individual wall in that particular direction.

The contribution of the perpendicular walls is neglected.

For example, in determining the total shear area in the Y-direction, wall 2 will contribute but wall 13 will not be considered.

For special cases such as wall 1 (circular section ),

half of the area is contributed to each direction.

The procedure for arriving at the total torsional stiffness at the location of interest is shown in the tables attached.

B.8-1

o.

Reactor hailding Shell so so Center of Mass s<

2 Ceaser of Rigidity or Massless Point Y 5-W) l d

ro R1sid ~ ~

/ o X (N-5) dyh-Translational and/or Rotational Spring F<

Interlot Strucaire

  • + y;#

f

~g 3 rc A

Radweste

&p Drywell seedon

  • (,,

m ei

,4,-

w ar s-do (vp

  1. 4, 30 tQ \\

Bh y

  • g$*- k r>**

sA

'r', shse1YWau~

Sy Cd.

]*3

  • /

j;

& Podestal ' *'

it

->J'-*n-

  • i.e.r 1.
  • )

y ani a

ao a w

IM 40,,

N' 40,,

' 4 4

ff<m dg mi 48 L _ j(,$T R a

a, n

v y

    • f 4

"a f

a a<

,,s

~ #

M

Aar,

, pf p n

l, sq.

?u j

y $

M l'*

< 91 2,

,A

' or y n %,~

vn or m f q w.

3 45 W'

^*

s,

s

' ^*

y l, mo se kl.

W T gg l'3 as a I

06 An

~ !* '

pg~

&/

mr M;

~M om r.2(

/*

Y*

FIGURE 1:

REACTOR BUILDING MATHEMATICAL MODEL

ni.no n.cn i iv % s, v.....

EDS, 0 LEAR

(

)

S AN FR ANCISCO, C%JTFORNI A 94104 220 MONTGOM E RY ST, a e (415) 4?15056 JOS NO.

PRwJECT yy

/reaWe s c +1=

0esf) J'w & i

?' 4 'p W <V

_ e.

DATE CLIENT TITLE SOudiu/

/defs 6 4 b

NE&

cnecaty (D

Ed Est '- 0 "

9M>

p-I l'l$

%.Ts 1

3 frae25 a /

IVsdr G

cY. WD" (3. wat/.s *2s C R' / N'-3/e#-A)>< Y

^' '

% Roche 4"9 1

3

/

b Beam Element 7

Between nodes

' - 4~

I i

4 100 & 130

/\\

.,i, i

f ji,

s. t.

MT t

Lt6

' i-6

/

  • 1-i" s-

=>

~\\

L

. Jro '

ec '

a--w -m,.

3 y

]

\\

tusmmunenusnw[.7sw77rw-iL E @nf JG c

e N

s s s Beam Element

/

50 N

k 101 & 294

,[

/q }ffl 'd, Betwen nodes 6

d

.d'

  • 6 y

6ge s

y v

/

4

,/

j 9

/,

e o

L th metic

,[

f x

4 I

A,.w.!

\\ 'h j (vA

,P L, t'.L. I S 4-o'

. /,^

j

/

1 A

N Qt k,

4 } '""

x l

-}M,3 L' m..c

--1 Y ~--

mm-- e

  • u

/

l h

rr.2_s i

'-O' NJO _ g,

'et I

n '.,

o72r-_c2

' - o.

i.

g. --

k t

)

Gl'--

,y

,g 2'

.,p-

?!![

%3- : h &g

's k-t 76 B ( Rt.4 on H,)

FIGURE 2 s

6 E. L. G,1 W^LLS @

+

y~

7-z a

2 l

2

Asx, A37, g ARE A A
Asy, X
ygg, Agx, y,4, 4,y ca, c q,,

g x

0 g

3x c4, y

xss. )

y,c. )

X IO X 10 g

g

~

a o

z N

$ h

l 15s3 36 [ 791 49 f'-

79f-SN C'OI C'O' O

UI

-17 05l.3p.st o s51L/_-

o 2 3 o 1 _ v_

v n

y e

2 687 75$

f 37. '7f -93 5

-6h 304:0 - tio.y5 s.Ac}2,

[r m,

~

l m

b 7 M59 /

Q 3

IRA 9.%7h lM9.b7b 9A75 sted gg.g 77 7 m

y p

7 n o If 13 00" 13.'o

-37, o"

-AsIf -54 05

o. O.?Ro / F l

9 19*00" 13 O 37 O' A stjo 19 9h o*00 52. / mh G

e t'

A

(,

18 06 ts.o

-st.c'

- 1497p -9s.05

o. l730 / i ni b

4 4

7 95'00 s,s.8 -37. o'

-20390 -5A $5

c. f6o 7 /(

l

~

e..,..

7 140 50 lic 10 -37 o

-l49s)9

-M.o,

o.tf O V f 2 i

V

/ f 9

75 05 7_90 (2 o '

om.o -5 05 0 0019 R

J n

o n

/

4 ?.

c P

~

10

%*O 55 0 37:0 >

pcv,.o y19.ns c.0219 5gg z g

)

9 x

o c,,

c F

.E s!

1 5 %

e> M

  1. =

1 I

\\

2 R=

7=

z 2

ma x m A,.T Asy. y ARE A As, Asy ycs.

Asx Yes. Asy Xcs. %q S

nt n y

9

?

g xse p y,c. )

X IO n io g,

~

PC g *

% 00) - A7 o' 13??f l9'97

  • 143 l-5 y f' ',

11 36 00 f-h 11 18 o 0 15 00, a f-o'

~

149} 0

(? op, 0 0736 /

564 75' 56Ak5' 93 b S2504f 126*h 9*0NY Y

Q u

n 13 f

9

  • c pz.o,

77 6 2 f %'0!

tcq > N o.mW

! 8 y1 ps o' J

g z

w du c,

19

,tt.o o"

  1. 8 o /

775 2136 0 109 af o. 33m o

g

/

a m

m v

y

_r (11

n f(

36 00 3s o' 37 O' 1332 0 69.il o t'75N<

9 0

1 17 y, oo "

36 o' 37 o' 1332d 69M o 175U

)

p p,3..

(g

?&*0a 36*Ol

.37sh-l3320

-49 c.0006 /

f y

'l n-

-l?37.'C

* k 0 00C? l 4

19 36 co' as o

-37o c

6 9

N

,n

'b d

(

.O 20 160 05 t00 0]

-lot 5 -lolcc.o

.6s M ct4%

& f 5

E E

C z

g x

O D' T W

d 5

\\g a

.h r)

EDS NUCLEAR: 220 MONTGOMERY ST.

SAN FRANCISCO, CALIFORNIA 94104 e

Joe no.

Cucar sv.

pg g g

oavec L. -

PROJECT PE C R C C k,_

f.

situ RLA c70p, bLD6, 6% w WALLS wi E or:

SHEAR A l2Ch ~r: 9 m cN CcN W u'-

0 Cl.

bA :A

~

\\

i

%. 0 "4

9 r

G

'O a:

is

  • o 5

'3 63 6\\

N tt 0

A K D

9 9

7 7

~

g o

o q

o o

s e e s

c

',M k.

b_@

.Gr p

O O

gQ

,'O o

te et m

m.

m m5 4

o f

C O

O C4

~-c n.} s O g i es y l7 ;R J-E W

g.

E Y

h w')?

(

9 k

y o r~

Il e t-4 A

MVg y

e m

m

'd a

6X l

o '-

L f

s?

sta o

9 k.

v

_8

_E Q

y, l-x pi A

M q

m C's d

I X

I M

o c.

y T

gj N

'6%

4 N 9-sO

  • D'

, o.

>y J.N O

,h 3

C.

-p o

cs

+

os, E

d d

O o

o _.

y

  1. 2' 4

O.

' S,N d

m m

g_

N K

I

' t I

I

\\

.u'

,la 9

s o.

5 f

9 0

m I

e x

r i

t'

~w

(

D O

k D

4

~

8 e

m L

i 6

o b

x A

p I

i 4

e, 1

T h.

%q,

Q

'q 9

~

0

  • A y

m i

a A

S "a

i 7-o m

1-h T

i k.' 'o..

N e

o x

o e.

c gj\\

C3 o

c M

i..

q, z

m e

g m

gs e

a e

w m

8 e

6 h.

,th p

p x

r b

m w

,9 a

4 i

M O'> i{

6' FT N 0ll">SS

-n e

Rocponco to NRC Audit Meeting Date:

January 10, 1984 Question No.:

B.9 QUESTION:

Provide calculations showing drywell stick model developme;st ( provide for one seetion only ).

RESPONSE

The methodology used in the development of the Drywell stick is covered in detail in Attachment I (

Reference:

Impell Report No. SED-76-017, Rev. 5).

In summary, equivalent beam properties were obtained based on analyses of the drywell structure using an axisymmetric model.

To develop the correct displacement pattern and benchmark both models, an anti-symmetric unit load was applied to the axisymmetric model.

As seen by the results in the attached Figure B-228, the equivalent beam model used for subsequent analysis reproduces very closely the displacement pattern obtained by the axisymmetric shell model.

A sample calculation of the equivalent beam properties between elevation 86.92 f t and 91.06 f t is provided in Attachment II.

l l

l l

l B.9-1

4 e

s i

I i

l l

ATTACHMENT I r

U 1

l m

SED-76-017, Revision 5 9.0 DISCUSSION OF SPECIAL STUDIES During the course of the Hope Creek seismic analysis, a number.of special studies were required in order to evaluate the effect of isolated structural components on the overall structural response of the Power Block area.

In

.-i_

addition, work was performed to summarize and envelope the floor response i..

spectra for individual buildings, in order to generate building envelope curves. In addition, a study was performed to investigate effects on seismic response due to cancellation of Unit 2.

~

g.1 Drywell Study The mathematical model for the Drywell constructed by the conventional approach of classical beam theory, when incorporated in the Reactor Building model, appeared to produce unrealistically high response results for the Drywell base shear and moment. In order to cccurately identify the interaction effects between the Drywell and other structural components of the Reactor Building, the Drywell dynamic properties were re-evaluated by means of an axisymmetric shell analysis under static and dynamic loadings.

Initially, a unit static shear was applied at the shear lug location of the axisymmetric shell model (Figure B-225). As can be seen from Figure B-226, the results showed that large longitudinal moments and circumferen-l_

tial forces occurred at those critical areas having abrupt change in geometric shape. An " equivalent" beam model was then constructed to match the static deflection of the shear model. This model had two (2) flexible short segments at the base of the Drywell and at the intersection of the cylindrical shell portion and the spherical shell portion (Figure B-227).

As a result of these flexible segments, the model is much more flexible than the " classical" beam model.

A comparison of static displacements between the three models is presented in Figure B-228. As can be seen from the figure, the revised beam model

=

closely matches the displacement pattern of the axisymmetric model, with both being considerably more flexible than the " classical" beam model.

In order to confirm the dynamic properties of the " equivalent" model, frequency and mode shape analyses, followed by a fixed base response spectrum analysis using the Regulatory Guide 1.60 Design Spectrum, were performed for both the axisymmetric shell model and the equivalent beam

=

model. As evidenced by Figures B-229 through 8-233, good agreement between the response of these two models was found.

I' 4: c result of the above analyses, the Drywell properties for the Reactor L-Building analyses were based on the equivalent beam model.

(

l l

1 _,

4l

'c 35>76017 FEVSION 2

=

l

=

I T

  • Node Number

.S 80nly few typiest nodes are shovr.)

i

  • 100" ( of syn. met.y, e3 j

o es

+00 -

l9 y

'24

+40 17 31

+70 -

3f

+40 -

33

,41 44

  • S,,

g

+50 -

b s1

- =

~

t1 m

3

.0 C7 o

o.,

' $3

+20 -

73

- =

+10 -

77

&l I

Base E1.86.92' 37 e

s s

s 0

10 20 30 40 Distance (ft)

-a DRYWEIl AXIfn"C!ETPJC MODEL TOTAL.1 ODES = 87 l k-FIGURE B-225 L.

PUBLIC SERVICE ELECTRIC & GAS CO.

SEISMIC STRUCTURAL

~ ~

ANALYSES HOPE CREEK PROJECT

3ED-76417 FEVEON 2

. vn

' $ of symmetry 8

At 9 - 0 I

i

~. Longmdinal moment

  • no *

-- Ciramferannal moment

- -Longtudinal bree a

--- Circumforsonal bree At 9 - too

+00 w Shear bree (Terce is 2 kip /S) 40 4 1 kip bree 4 shear Ing locanon

/

g v

=

50 3

l 2

f as s

4 i

c

\\

l '

  • N 4'

i

'Q,,k,{,.

d 40 5.,

N g*,,%,

N, g

' j 40 N \\,

\\\\

'\\

+so l ;_

t,

8 s

.g

/!

l !

/ l sto l

/

, nase rl. ss.s2 N

^

^\\

l ai -

/

i e# r o-ERTTYLI. - A.M! METRIC SHELL STCDr! r87 NODEST SHILL STRESS

=l FIGURE B-226 S

em ANALYSES g

HOPE CREEK PROJECT J

a p.

M76017 RMSON 2 1

1 1

~

1 1

192.38 - ol e Node Numte r Class Pei t'.

189.41 02 o Node Nu:r.hr (11ssa ess Peint 184.29

  • 1 177.30 4

o5 174.33 168.00

'6 3

in:i? : !!

I 154.00 "9

146.45

- olo 11 141.20 136.03 "12 1

128.00

<'13 121.63 ole

'15 114.00 107.00

'16 1

103.59 017 100.17

'i18 91.06 o19 1

I 86.92

,20

/ //fi // f DRYWELL EQC7 VALENT BE.Of %f0 DEL l3 m_m

,- N-. 0 I

1

'I 3

eUstiC service ELECTRIC & GAS CO.

SEISMIC STRUCTURAL i

ANALYSES HOPE CREEK PROJECT x]

.._x SED-7&O17 FEVt5CN 2 I_

. l' W Ie STAEC DISPT AcntCT COTTPARISCN I_a.

. - Seam Model,'3ased o: 3eam heot1 Ig Equivalent Beam Model 200

- ~ ~ AusNetrt: Shell Model

=

/

/

I i

l

/

180

=

a

~.I

/

/

I

/

=

~ l D f0 M ' I O *&F 4 160

=

l

/

i-i l

1" 5

2 1

I u

120 i

~

i si 100 I

I i

80 0

1. 0 LO
3. 0
4. 0
1 Displacement (x 10-5 ft. )

1 DRYWELL (FREE STANDING FIGUIE B-228 44 e

ANALYSES m

HOPE CREEK PROJECT u

___7,--

)

SED-76017 MVSON 2

. m i

MODE SMAPE COMPARISON - TIPST MODE m.

Equnalent Beam Model

-- - Axisymmetric Shell Model e,

- - 200 TREQUENCY Beam Model.13 = 6.80 cps Shell Model, f = 6.33 cpe g

\\

180

\\

\\

a m,

f E-160 g

.a

=

\\

g

\\

j

.l -

\\

j

\\

140

\\

\\

.m 120 m,

. goo 1

'ou

-1. 0

-0.3

0. 5
1. 0 DP.NELL ITREE STAND!NC)

FIGURE B-229 3-t a

'}

PUBLIC SERVICE ELECTRIC & GAS CO.

SEISMIC STRUCTURAL

~

ANALYSES 2

HOPE CREEK PROJECT g

nJ

3ED-7&O17 FEVERTA 2 l

M W

MODE 5 RAPE COV.PARISO - $ECCND MODE

=

quhalent Beam *:cdel

~ ~~ A.T. symmetric Shell :: odd 200 TREQt*NCY

\\

Eeam Model, f

  • l7'4? #p$

2

\\

=

5. ell 3todel, f = 17.10 cpe

\\

130 2

N s

N'g s

e

\\\\

s N

(-'140 3

g I

I 120 g

~

l m

1 100/

/

/

/

90 i

=

-1.0

-0.5 0.5

1. 0 DRYTELI. IFREE STANDING) l t

FIGURE B-230 4

O ANALYSES g

HOPE CREEK PROJECT J

e EIF7601< IE! EON 2 REOL'LATCRY CUIDE 1.60 RESPON>E SPECTRt31 ANALWJ 3tANnft37 HCRITOMAL ACCELERATION CO3f?AR50N w

~

..- Or# Beam Stodel 3

Equivalent Beam 3!odel luu '

Az1 symmetric Shell Stodel

=

/

/

ll 180 -

//

a g

/r ir' O

w, -

E

/s

/

5 a

l ll 1

120 -

il g

jf' e

o a

100 '

  • l 4

~

u SO 0

10 20 30 2

Horizontal Acceleration (ft/sec,

o DRYWELL rFREE STANDTNG)

J FIctme B-2n

  • M g

e ANALYSES HOPE CREEK PROJECT

1

].

SED-7&O17 IE/ISON 2 a

\\

REGULATQRY Ct.TE 1.60 SESPONi SPEC--'. " ANALYSTS MANTSC! MORI2ONTAL DISPIACEMLT COMPAPl50N

=

Onc.M Beam Model

~

Eqm alent Beam Model 200 A.tisymmecac Shell Modd I

/

I

/

?

/

-[

l

/

1so -

o o

,/

t I

o l

s' 160 I

/

l'

/

=

i

/

i

/

=

%m-n'

/

t i

I i

8 q

1

=

o2 I

/

i

/

M*

l

\\

l

~

8 0

1 l

I j'

100 -

f I

, o' 1

e 80 i

i 0

0. 5
1. 0
1. 5 Displacement (x 10-2 m l

DRYWET L fTREE STANDING a

FIGJRE B-232 5

m ANALYSES HOPE CREEK PROJECT

_ O

\\

~

!]

SED-76417 FEVt90N 2 I

m, RECT.*LATORY CLTE 1.60 RESPONSE SPEC R*J3! ANALYSIS

~

3 LOC 3tT*313tOMENT COMPAF.ISON

- -- Ort;;1:a1 Beam Model Equaalent Beam Model Ausymmunc 9 411 Model 200 ISO

\\

\\

160

\\

E

\\

\\.

\\.

2 140

\\,

\\

\\

\\

120 s

\\

s

\\

s

\\.

IJO g

's

\\

\\

\\

s G.96-i 0

1.0

1. 0

- 3. 0

4. 0 4

Moment (x 10 bytt)

DRY'A 2LL # FREE STANDING)

FIGURE B-233 e

O ANALYSES HOPE CREEK PROJECT

e 1

ATTACHMENT II l

i

' Attachment to Response B-9 Development of Equivalent Beam Model Properties t.ylvlt><ti" l3esut alo/e/

~

~

Cl+ye-d e l9 coc <did To Lo o, 9' 0 0.

s O%

d

~

M = VI. o6 kjt-z 4

.=

a
F =. I jy O BE ok Nk WM, Lo d v.us s

V 3

d. B 6.Q '

l s Q>4 yx.(go) = c. f 4 so$ to' jf c a.ic'fp? d,pe'/Jow) o c 6 utk SO:10*) ~ 0 "92/< 'O' 11' Qo.o'jwaAf!/bg)

o. p f217 to'"- c, f wi sio

~

.y a

9-

2. Jl0 s to

=

50 -G. i4 v

f2eh I. E. l)gevie4.ct.N

"'Itist of IYA bCb(M b' fi s", PP%

3 it e r GEI 1

Sg- 0 0+ t) 4 ge( s 6) 9 1

gel

+

(4 + $ ) EI. 8 Lt. = -

4

. f 4"O N O

,,,,g y, p,I o.i/Je~no*-a14w1naj,,,3gpm f;0/- Uar+

1 a. n r,,o -r zz/n e

z 4 TEM I

CUENT i),uwo//

L, sra sl

~ sL

,)

Crnbi l

j

- i -

/d O. *W l$

yr/

l""Mo //./ l*8tP{

l" 'J/f l/7)

I '"'2 *' //

h EDS NUCLEAR:

220 MONTGO! AERY ST.

SAN FRANCISCO. CALIFORNIA 94104

s..)

.s 6 EZ t

s

,,(,,gl74-9}

(th ->

e sez

/1 Y =

l [z 4 ~0 r, (z.

g ser i*

[h 4 'd) ~ /

g, pe.

SdZ 321 EI 0l

[0 IOz V

IL je(f+4) A f(ist)

  • ~

/

hh fG

+

1

($

k T 8.')

I*

g p ( ltz *

~~

y

  • l) t gg ? $L/ +

SS b

f

$)-/

a C, g e i

V iTru cutNT

/)<enu/ //

Ann n!. e sh tlM P 0*/b l

/

'n i

/dO, rJT)/2.

ut/

l"2/0 /21 l'"'6Cid l" 2/1/ h 7 l "' A-II h

EDS NUCLEAR:

220 MONTGOMERY S.

~.}

b

~S

/{st 4=

0.fde s /0 9 = Z..?T rinY

= i. o 6 - 7/ o c=- 9.D x to '

.o - o,3

TlGu, T = 3 2.1. S k*107.I M,

iaz z e ruo)z

+=

A-l'6A ey z

/

u - r. n Ist It]

1* 322.

{T*

{t '

As,-

s.9'+

Ckab

/Z 51 2 4 (/"C) Z Q=

10 2. / 2

=

l'trAs fA t/

0. C L 6 ( E A) ~ /. D$3 ( Ed ) * /

-/.oJJ(d4) + 20.04/ (if)= Il J

Bo r 4/

- ft.ol.7) fI/)

3./3]

c 4 = (0.128)f6! oy/) - {t.of1)'

c ro.rz8X10

-f t pD co.rzs)(Joset)- (i.ofj)s

"#'$If 50 "

4=

f.5 /

/ /0 " !

f

~f 6-c-2.Jc/fstO

^

ITEM CUENT Pran1 11b~*l1.l

/.,M S de,y reo fl O ##b -

id o, en)/2.

my I'* " 4 4 2 l** 4o/

I""! 4,h,

I'"'t ' / /

EDS NUCLEAR: 220 MONTGOMERY ST.. SAN FRANCISCO. CALIFORNIA 94104

Response to NRC Audit Meeting Date:

January 10, 1984 Question No.:

B.ll OUESTION:

Define location of (x, y, z)

"0" reference points for auxiliary building model.

l RES PONSE:

The attached Figure 1 shows the auxiliary building mathematical model.

The auxiliary building plan at the ground elevation (elevation 54.0 f t ) is shown in Figure 2.

The reference coordinate system used for the calculations of building properties is shown in F igure 2.

Based on this coordinate system the following is calculated:

a.

The center of rigidity for the Control /Radwaste area has x,y, z coordir. ate (in f t. ) of (0.84, 114.09, 54.0).

This joint corresponds to nodal point 39 in Figure 1.

b.

The center of rigidity of the Diesel Generator area has x,y,z coordinates (in ft.) of (0.0,

-89.70, 54.0).

This point corresponds to nodal point 128 in. Figure 1.

c.

The center of mass of the complete plan system of walls has x,y,z coordinates (in f t.) of (0.0,

-13.00, 54.0).

This point corresponds to nodal point 2 in Figure 1.

This is the node at which the translational and rotational motions are input to the building model.

l B.ll-1

.__ _ _ o _ -_._ _

m.._.--,,. _ _ m _.,, _, __

SED-76 017 REVEON 3 Access Control /Radwaste Area

[4g p

Si h d'

c Diesel Generator Area 9

-/

[$.-

s i

WW<1($V' l} V l5 v~

l O

ses Y(E W)

X(N-5)

I.

AUXILIARY BUILDING MATHDfATICAL MODEL FIGURE 1 PUBLIC SERV!CE ELECTRIC & GAS CO.

SEISMIC STRUCTURAL ANALYSES HOPE CREEK PROJECT gy

~

(a.

4

_=

SED-76 017 REVEON 3 N

NY I

f-r.g s

mss s s m s s s s s s sss s m s

.s y.

m.

s s

,6 sY,;

N\\ \\ N sX A Y \\ \\ \\ sa

.g s

is s s s s u s s s,ssuxxu i s s s u3m N

s s

s s_

o 5

s s

k Nxxxxxxxxxxxu xxxAssssssuss) m Control y

s s

Radwaste l

Area s

s s

s s

s N

s F1. El. 54'-0" F1. El. 54'-0" s

s s

N

\\

=i s

s s

N 2

N s

I N

N ss s, _

6 _. s s rx s s s s s s s s s s s s I

Diesel Area Fl. E1.54'-0" F1.E1.54'-O" Co b

t 1

m

' ]

i 1

Ref: Drawing #SK-C-635(A)

~

<m j

kN N N Ni MEMBER 39-40 l

i i

MEMBER 128-140

]

AUXILIARY BUILDING PLAN AT ELEVATION 54'-0"

}

FIGURE 2

.m m.

PUBLIC SERVICE ELECTRIC & GAS CO.

SEISMIC STRUCTURAL ANALYSES HOPE CREEK PROJECT

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

A.7 QUESTION:

Provide a simplified calculation for overturning of reactor building foundation mat.

moment

RESPONSE

The factor of safety against overturning for the reactor building as'given in FSAR Appendix 3H was based on the energy method approach described in BC-TOP-4A (FSAR Reference 3.7-1). During discussions with the NRC, the NRC requested the factor of safety against overturning be esiculated using conventional methods.

The factor of safety against overturning using conventional methods is 3.60 which exceeds the minimum safety f actor of 1.10 specified by SRP Section 3.8.5-11 of NUREG-0800 FSAR Appendix 3H will be revised to indicate the factors of safety against overturning by both the energy method and conventional method.

l t

i A.7-1

O Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

A.10 QUESTION:

Justify the boundary conditions used at the base of the drywell shield wall.

RESPONSE

The drywell shield wall was modeled using a finite element analysis. The base was assumed to be at el. 83 f t-0 in., since this is the elevation of the junction with the support pedestal.

Calculations and drawings indicate that the reinforcement required at al. 54 ft-0 in. was extended to el. 83 ft-0 in.

The reinforcement design was reviewed by Mr. L. Yang of the NRC Scaff during the NRC Structural Audit.

l l

A.10-1

ROCponco to NRC Audit Meeting Date:

January 11, 1984 Question No.:

A.ll QUESTION:

Justify the boundary conditions used for the analytical model of the reactor building dome.

RESPONSE

As presented to Mr. L. Yang of the NRC Staf f, the model boundary is cut off at el.

201 ft.

The boundary at el. 201 f t is assumed to be restrained.

Our justification is as follows:

- A plot of the deformations under lateral loads shows that most of the displacements die out at the elevation of the corbel (elevation 239 ft), which is well above the cut-off elevation.

- The cylinder wall is continuous below the cut-off elevation to provide for the continuity effect in the vertical (meridional) direction.

The cut-off elevation also corresponds to the elevation of the operating floor diaphragm which provides a fixed condition in the radial and circumferential directions.

l A.ll-1

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

A.15 QUESTION:

Explain whether a heavy load drop event needs to be considered for the intake structure gantry crane.

If so, provide the results of a heavy load drop for the intake structure roof.

RES PONSE:

As discussed with Mr. D. Jeng of the NRC Staff, a heavy load drop event need not be considered for the intake structure gantry crane for the reasons stated in HCGS FSAR paragraph 9.1.5.3.3hh.

l l

1 l

l A.15-1

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

A.17 QUESTION:

Provide a typical calculation for the knuckle region of the re:ctor building dome using critical loads.

l

tES PONSE:

As presented to Mr. L. Yang of the NRC Staf f, the I

area of transition from the cylindrical to spherical portion of the dome (knuckle region) sustains the highest moments and axial forces.

In the meridional direction, the maximum f actored moment of l

5375 f t-lbs/f t is combined with 32,590 lbs of axial compression.

Meridional reinforcement of No. 7 bars spaced at 18 in. is provided on both faces.

The circumferential reinforcement of No. 9 ba rs at 18 in. on each face is based on the maximum f actored l

tension of 5320 lbs/f t and moment of 1401 ft-lbs/ft.

l l

l l

l t

A.17-1

Response to NaC Audit Meeting Date:

January 11, 1984 Question No.:

B.1 QUESTION:

Provide the deflected shape and the soil contact pressures for the reactor building foundation mat (if contact pressures are non-uniform).

RESPONSE

As indicated in FSAR Appendix 3D, Load Combination 1.4D + 1.7L + 1.0F1 (F1 la load due to post-accident containment flooding) governs the flexural reinforcing requirements for the reactor building basemat.

This load combination also governs the maximum deflected shape of the reactor building foundation.

As shown in Sketch B.1-1, the maximum deflection occurs under the drywell pedestal and radiates outward in an expected dish shupe pattern.

Load combinat' ion D + L governs the soil contact pressuree for the reactor building foundation.

As shown in Sketch B.1-2, the maximum soil contact pressure is 8.21 ksf (compression) and does not exceed the estimated allowable static bearing capacity of 12 ksf for the Vincentown Formation as discussed in FSAR Section 2.5.4.10.

This maximum contact pressure distribution is assumed to occur during the construction stage when all dead and live loads are applied and the site dewatering system is not turned off.

The above was discussed with Mr. L. Yang of the NRC during the NRC Structural Audit.

l B.1-1

1 llll I!

I 1ill l

7 o

h O

7 T

Y

)

S E

D H

/

C 0

)/

\\

N

. J 1

I s

m F

~

/

(

o

( w[

g N

E

[

i\\

P

+

7 A

t H L c.

.\\

/

S 7

/

/

/

JJ 4

D

/

1

/ /

/

E T

+

C D

/O-

^

E D

1 L

4 F

l E

1 D

B 3s x

i

\\/

N N O H O

I C

I T

T O

T A

E l

S-f A N K

D I

S N B q

/

/

\\

U M O O F

C Y

R R G D o A T

N A 4

w O

I C N A U D

L 4

I s\\

o L

E R

I R

U O B

F

\\

2 R

2 O

T C

4 A

/

[

E s

R g

4 s

I

\\

I a

y

-G.5/

-S.I9

-3.02

-2.G0

~s75

-4.52

-3.97

-3. /5 I

l s

-G OI

- 4. 2/

- 3.73

-3.00

-7.03

-5./.9

-4.59

-3.69

-G 00

-537 5

.y

. 6 01

~6.89

-G.46

-4

-63

-3.BT.f

-706

-735 -7tS

.02 T

-788 <%

-729

[ "f M

U Nk -G.7G -E3/ g GS/ 747 g e 64

.k w 4 k h h $$

N' 7

.52 M h

N N

-775 %- -72

- G.G5

-725 -708

-597 f

O

- G.4 6 -621 '

.5.73\\od S

-4.

-4 83

-4 56 2.64 I

r.

-2.76

-2.G2

-2.51

-lG9 y

/92 L G" l

REACTOR BUILDING FOUNDATION SOIL CONTACT PRESSURES (KSF)

FOR LOAD COMBINATION D + L

("

" indicates compression)

SKETCH B.1-2

Response.to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.2 QUESTION:

Provide calculations for the factors of safety against sliding and overturning for OBE and SSE cases for the drywell shield wall.

RESPONSE

The maximum overturning moments at the base of the drywell shield wall are 410,000 k-ft (OBE case )

820,000 k-ft (SSE case)

The f actors of safety against overturning are:

F.S. = 6.42 > 1.5 (OBE case)

F.S. = 2. 7 3 > 1.1 (SSE case )

The maximum shears at the base of the drywell shield wall are 4580 kips (OBE case )

6380 kips (SSE case )

The factors of safety against sliding are:

F.S. = 3.79 > 1.5 (OBE case )

F.S. = 2.72 > 1.1 (SSE case )

Calculations for the factors of safety against sliding and overturning for OBE and SSE cases for the drywell shield wall were reviewed by Mr. L. Yang of the NRC Staf f during the NRC Structu il Audit.

B.2-1

Response to hRC Audit Meeting Date:

January 11, 1984 Question No.:

B.3 QUESTION:

Provide calculations of seismic shear force distribution in the cylinder wall.

RESPONSE

The seismic shear forces are distributed to the shear walls in proportion to the relative rigidities of the shear walls.

l The total seismic shear forces at the base of the reactor building shell are Condition Direction l

Shear (kips)

OBE

, North-South 27,400 OBE East-West 30,500 SSE l North-South 48,000 SSE i

Eas t-Wes t 71,000 The seismic shear forces at the base of the cylinder wall and the percentages of the total reactor building seismic shear forces are:

Shear Percentage of Condition Direction (kips)

Total Shear OBE North-Sou th 6,356 23 OBE East-West 6,482 21 i

SSE l North-South 11,134 23 SSE i

East-West 15,090 21 It should be noted that the values represent the results of the analysis performed prior to the cancellation of Unit 2.

The calculations incorporating the result of the Unit 2 cancellation study are in j

process.

l Calculations of seismic shear force distribution were reviewed by Mr. L. Yang of the NRC Staf f during the NRC Structural Audit.

B.3-1

RsOponOS to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.4 QUESTION:

Provide calculations for overturning of the cylinder wall.

RES PONSE:

The maximum overturning moments at the base of the cylinder wall are:

1.792 x 106 k-ft (OBE case) 3.05 x 106 k-ft (SSE case)

The factors of e:fety against overturning are:

F.S. = 3.8 > 1.5 (OBE case)

F.S. = 2.1 > 1.1 (SSE case )

Calculations for overturning of the cylinder wall were reviewed by Mr'. L. Yang of the NRC Staf f during the NRC Structural Audit.

f, B.4-1

' w :: "

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.S

,UESTION:

Explain the assumptions used for tha deep beam design Q

of the fuel pool walls.

RES PONSE:

The design of the fuel pool walls is in conformance with the Portland Cement Association (PCA) publication,

" Design of Deep Beams".

This method considers the nonlinear stress distribution along the height of the wall.

The stresses and tensile forces were determined from the appropriate design curves in the PCA publication as a function of the height to span ratio of the wall.

The reinforcing steel was designed to resist the tensile forces.

Calculations and drawings of the fuel pool walls were reviewed by Mr. L. Yang of the NRC Staf f during the NRC Structural Audit.

l l

t I

t I.

l B.5-1

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.6 OUESTION:

Explain the method of inputting the loads into the ASHSD dome model.

RESPONbE:

As presented to Mr. L.

Yang of the NRC Staff, the lateral seismic loads were input into the computer analysis employing a partial Fourier Series representation of the load.

A uniform lateral load was applied by combining the second harmonic of the radial and tangential loads.

B.6-1

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.7

)

QUESTION:

Provide calculations demonstrating that the dynamic

)

effects of tornado depressurization are not gove rning.

RES PONSE:

As presented to Mr. L. Yang of the NRC Staf f, the computer analysis is performed in the following manner

- Dead loads, live loads, seismic loads and tornado depressurization loads are applied to the model individually.

- For each individual loading the shears, moments and axial forces are established for each element.

- The above information is then input into a post processor routine which combines and factors the individual loads into the potentially controlling load combinations.

- The resultant moments an forces are generated for each element.

- To simplify the interpretation of the output, the routine selects the shears, axial forces, and moments from the loading combination that yields aither the maximum or minimum value in each direction for each element.

. These maximum and minimum values are then used

[

for the design.

Accordingly, the controlling elements may have loads and moments in various directions conservatively combined from more than one loading combination.

Therefore, it is not possible, nor is it necessary to confirm that the effects of tornado depressurization are not governing.

t B.7-1

Response to NRC Audit Meeting Date:

January ll, 1984

{

Question No.:

B.8 QUESTION:

Provide worst case calculation of auxiliary building room subject to abnormal pressure.

RESPONSE

A calculation of the design of an auxiliary building room subject to abnormal pressure was shown to Mr. D. Jeng of the NRC during l

the structural audit.

The following areas of the calculation were reviewed:

- Calculation of forces and momer.ts due to abnormal pressure

- Cambination of forces and moments due to abnormal pressure with forces and moments due to other loads

- Determination of reinforcing steel requirements.

All areas of the calculation were described to the satisfaction of Mr. Jeng.

l 1

B.8-1

Response to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.9 QUESTION:

Provide maximum tangential shear stresses in the drywell shield wall and the cylinder wall.

RESPONSE

The maximum tangential shear stresses are:

136.2 k/ft for drywell shield wall 148.1 k/ft for cylinder wall The shear calculations were reviewed by Mr. D. Jeng of the NRC Staff during the NRC Structural Audit.

B.9-1 l

R3npon;e to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.12 QUESTION:

Provide static factor of safety against overturning for intake structure.

RESPONSE

The factor of safety against overturning for the intake structure as given in FSAR Appendix 3G was based on the energy method approach described in BC-TOP-4A (FSAR Reference 3.7-1).

During discussions with the NRC, the NRC requested the f actor of safety against overturning be calculated using conventional methods.

The factor of safety against overturning using conventional methods is 1.12 which exceeds the minimum safety factor of 1.10 specified by SRP Section 3.8.5-II of N UR EG -0 800.

FSAR Appendix 3G will be revised to indicate the f actors of safety against overturning by both the energy method and conventional method.

i B.12-1

R2ponco to NRC Audit Meeting Date:

January 11, 1984 Question No.:

B.13 QUESTION:

Provide two or three calculations illustrating use of 0.9 dead load factors.

l

RESPONSE

Three calculations illustrating the use of the 0.9

~

dead load factor for the reactor building were reviewed by Mr. L. Yang of the NRC Staff during the

{

the NRC Structural Audit.

Similar celculations eximL for other Seismic Category I structures.

B.13-1

R30pon2s to NRC Audit Meeting Date:

January 12, 1984 Question No:

A.1 Question:

Describe the procedures which assure that the I

post-modification seismic loads for the torus were examined and that the torus structure was found to be adequate to resist the post-modifi-cation seismic loads.

Response

The evaluation of post-modification seismic loads for the torus was separated into two parts:

An evaluation for horizontal loads and an evaluation for vertical loads.

The support design for the torus, i.e. pinned-pinned vertical columns and pinned lateral restraints, assures that horizontal and vertical behavior are uncoupled, thus allow-ing consideration of them separately.

This was confirmed by the results of the selsn.ic analysis of the unmodified structure, which also show that responses in each of the horizontal and vertical directions are dominated by one structural mode.

For horizontal loads, an evaluati7n was made of the effects of the torus modifications on the horizontal seismic analysis for the unmodified con-figuration.

It was concluded that the effect of the torus modifications on the horizontal seismic response of the torus is negligible.

The modifica-tions added to the torus consist mainly of local column connection stiffening which does not sig-nificantly change the dominant horizontal torus frequency.

The original analysis for horizontal loads is conservative, since the stiffening effect, though insignificant, would tend to increase the dominant frequency, resulting in lower accelerations applied to the torus because of the position of the frequency en the response spectrum curve.

The evaluation described above was performed as part of the Hope Creek Plant Unique Analysis.

For vertical loads, a new analysis was performed l

using a finite element model of the modified torus.

The results of this analysis are documented in the Hope Creek Plant Unique Analysis Report.

R0gponso to NRC Audit Meeting Date:

January 12, 1984 Question No:

A.2 Question:

Justif,y the methods used to consider fluid structure interaction ef fects for analysis of the torus.

Response

Fluid structure interaction effects are considered in the torus analysis through the use of a fluid added mass formulation which results in a " consistent" mass matrix, i.e. a mass matrix having off-diagonal terms, representing the mathematical coupling of the fluid.

Fluid compressibility and surface gravity effects are neglected.

It is also assumed that there is no irrotational flow (viscosity), no steady flow (aerodynamics) and no non-linear effects (cavitation).

The assumption of an incompressible fluid is apy.

priate if structural frequencies of interest are not in the range of either fluid sloshing frequencies or fluid accoustic frequencies.

Fluid sloshing fre-quencies for the Hope Creek torus are less than 1 hz.

Accoustic frequencies of the torus are obtained by dividing the velocity of sound in water by a charac-teristic length.

Using the maximum water depth in the torus as the characteristic length, gives a corres-ponding accoustic frequency of over 50 hertz.

The dominant structural frequencies of the torus for the loadings defined in NUREG-0661 range from 15 hertz to 35 hertz.

They are sufficiently far removed from the sloshing and acoustic frequencies of the fluid, so as to justify the assumption of an incompressible fluid.

l

a e,

Respor.se to NRC Audit Meeting Date:

January 12, 1984 Question No:

A.3 Question:

Describe how the effects of relative seismic dis-placements of the torus were considered for the stress evaluation of the vent system.

Response

The effects of relative seismic displacements of the torus on the vent system were considered by approximating the maximum relative support dis-placements using the floor response spectra.

The maximum dispigcement for each support is predicted by Sd = Sag /w, where Sa is the spectral acceleration in g's at the high frequency end of the spectrum curve, g is the gravity constant, and w is the fundamental structural frequency of the torus in radians per second.

The resulting displacements from this calculation, 0 01 in. in the horizontal direction and 0.017 in, in the vertical direction, are small compared with those of other major vent system loadings such as SRV discharge and pool swell and have a neglible effect on the vent system.

4