NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. enmaa annt June 7,1999
+
Mr. Harold W. Keiser i
Chief Nuclear Officer & President -
Nuclear Business Unit Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, NJ 08038
SUBJECT:
CHANGE TO COMMITMENTS ASSOCIATED WITH GENERIC LETTER 89-13,
" SERVICE WATER SYSTEM PROBLEMS AFFECTING SAFETY-RELATED EQUIPMENT," HOPE CREEK GENERATING STATION (TAC NO. MA5449)
Dear Mr. Keiser:
We have completed our review of the May 10,1999, letter that was submitted by Public Service Gas and Electric Company (PSE&G) providing an updated status on the implementation of commitments that were made in response to Generic Letter 89-13, " Service Water System Problems Affecting Safety Related Equipment." It is our understanding that while you have been able to periodically clean and inspect the safety auxiliary cooling system (SACS) heat exchangers for the Hope Creek plant in accordance with the commitments that were made previously in a PSE&G letter dated August 1,1997, you have not been able to effectively monitor the pressure drop across the SACS heat exchangers due to limitations that exist in the sensitivity of installed instrumentation. Consequently, you have not been able to fully satisfy your commitment to monitor the pressure drop across the SACS heat exchangers (on the service water side) to detect the onset of macro fouling. In order to resolve this problem, the previous PSE&G commitment is being revised to do the following:
1 1)
During the next refueling outage, RF09, Hope Creek will open, inspect, and clean the
'D SACS heat exchangers in a manner consistent with the previous two outages. An appropriate frequency for SACS heat exchanger inspection will then be determined based upon the data collected during RF07, RF08, and RF09.
60g 2)
Using portable test equipment, baseline pressure drop readings will be taken by June 1, 1999, for all four SACS heat exchangers. Periodic pressure drop readings will then be taken as necessary (initially quarteriy) in order to monitor the heat exchangers such that the onset of macro fouling can be detected. Test equipment options for future measurements will be evaluated.
990610009i2 990607 PDR ADOCK 05000354 P
PDR J
o
(
H. Keiser June 7, 1999 Your revised commitment is acceptable tu the staff. However, micro fouling is also an important factor and should be included in your assessment of the SACS heat exchangers when establishing macro fouling acceptance criteria.
If you have any questions regarding this matter, please contact me at (301) 415-1420.
Sincerely, original signed by:
Richard B. Ennis, Project Manager, Section 2 Project Directorate l Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-354 cc: See next page DISTRIBUTION Docket File JClifford JTatum PUBLIC MO'Brien GMeyer, RGN-l PDI-2 Reading REnnis OGC JHannon ACRS hf d h{
y DOCUMENT NAME: G:\\PDl-2\\ HOPE CREEK \\LTRAS449.WPD OFFICE PDI-2/PM PQFf SPLB/
PDI-2/SC NAME REnnis M Nh((eI JHannon JCI rd CW/99 h/ N/99 h /7 /99 4 / i /99 DATE
/
' OFFICIAL RECORD COPY
- ;'OO21
I L,
(
iN H. Keiser June 7, 1999 l
Your revised commitment is acceptable to the staff. However, micro fouling is also an important factor and should be included in your assessment of the SACS heat exchangers when establishing macro fouling acceptance criteria.
If you have any questions regarding this matter, please contact me at (301) 415-1420.
Sincerely, 1
l original signed by:
Richard B. Ennis, Project Manager, Section 2 Project Directorate l Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-354 cc: See next page DISTRIBUTION Docket File JClifford JTatum PUBLIC MO'Brien GMeyer, RGN-l PDI-2 Reading REnnis OGC JHannon ACRS l
l l
i DOCUMENT NAME: G:\\PDI-2\\ HOPE CREEK \\LTRA5449.WPD 1
OFFICE PDl-2/PM PD#
SPLB/h PDI-2/SC l
NAME REnnis M Nhke$
JHannon JCibrd l
Cb/99 h/ h/99
[o /] /99 4/i/99 l DATE
/
' OFFICIAL RECORD COPY 4
i L
s-i
+
H. Keiser.
l Your revised commitment is acceptable to the staff. However, micro fouling is also an I
important factor and should be included in your assessment of the SACS heat exchangers i
when establishing macro fouling acceptance criteria.
If you have any questions regarding this matter, please contact me at (301) 415-1420.
Sincerely, M
Richard B. Ennis, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-354 cc: See next page i
f 4
l i
)
t A
\\
l Hope Creek Generating Station cc:
Jeffrie J. Keenan, Esquire Manager - Joint Generation Nuclear Business Unit - N21 Atlantic Energy P.O. Box 236 6801 Black Horse Pike Hancocks Bridge, NJ 08038 Egg Harbor Twp., NJ 08234-4130 Hope Creek Resident Inspector Richard Hartung U.S. Nuclear Regulatory Commission Electric Service Evaluation Drawer 0609 Board of Regulatory Commissioners Hancocks Bridge, NJ 08038 2 Gateway Center, Tenth Floor Newark, NJ 07102 Mr. Louis Storz Sr. Vice President - Nuclear Operations Lower Alloways Creek Township Nuclear Department c/o Mary O. Henderson, Clerk P.O. Box 236 Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Hancocks Bridge, NJ 08038 General Manager - Hope Creek Operations Mr. Elbert Simpson Hope Creek Generating Station Senior Vice President-P.O. Box 236 Nuclear Engineering Hancocks Bridge, NJ 08038 Nuclear Department P.O. Box 236 Director - Licensing Regulation & Fuels Hancocks Bridge, NJ 08038 Nuclear Business Unit - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Regional Administrator, Region i U.S. Nuclear Regulatory Commission 475 Allendale Road i
King of Prussia, PA 19406 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 i
l l
4 I