Forwards Revision 1 to Inservice Insp Program,First Interval for VC Summer Nuclear Station
ML20066E782
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/10/1982
From: Dixon O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20066E783 List:
References
NUDOCS 8211170181
Download: ML20066E782 (22)


Text

.

SOUTH CAROLINA ELECTRIC & GAS COMPANY Post orrics 7s4 COLuusiA. south CAROLINA 29218 O. W. DixON. JR.

Vice PneseoENT Nucitan OrtnatioNs November 10, 1982 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, DC 20555

SUBJECT:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Inservice Inspection Program Revision 1

Dear Mr. Denton:

In response to the Nuclear Regulation Commission questions communicated by telephone on September 19, 1982, regarding the Inservice Test Programs for valves and pumps, South Carolina Electric and Gas Company, acting for itself cnd as agent for South Carolina Public Service Authority, hereby submits ten (10) copies of Revision 1 to the Inservice Inspection Program along with appropriate relief requests.

The following explanations are offered in response to the NRC questions:

1) The attached pages (1 through 20) describe the valve test changes to GTP-002 Revision 4.
2) GTP-001 Revision 3 relief request A-1 for the four (4)

Diesel Fuel 011 Transfer Pumps has been rewritten to clarify the relief reque s t.

In addition, GTP-004 Revision 2 relier requests have been added for the following systems:

1) Post Accident H2 Removal
2) fiesidual Heat Removal
3) RB Spray Containment Sump Suction Guard Piping j(c)5/~7

) f(:>

' 8211170181 821110 '

PDR ADOCK 05000395 O PDR

Mr. Harold R. Denton Inservice Inspection Program Page Two November 10, 1982 Administrative Procedures AP-406, AP-407, and AP-405 have been rewritten and renumbered as SAP-145, SAP-304, and SAP-302 respectively.

WM-1.0 and WM-2.0 have been revised and are submitted as part of the program.

The procedures listed below in the lef t column are to be removed.

The procedures listed in the right column are to be inserted in the program at the appropriate location. Insert the relief requests behind the appropriate procedure.

REMOVE INSERT Introduction Introduction,.Rev. 1 AP-406 SAP-145, Rev. O GTP-001 GTP-001, Rev. 3


GTP-001, Relief Requests GTP-002 GTP-002, Rev. 4


GTP-002, Relief Requests GTP-004 GTP-004, Rev. 2


GTP-004, Relief Requests AP-407 SAP-304, Rev. O AP-405 SAP-302, Rev. O WM-1.0 WM-1.0, Rev. 2 WM-2.0 WM-2.0, Rev. 2 A black vertical bar in the right hand column of each page indicates a change to the procedure and/or the introduction to the program.

If there are any questions, please call us at your convenience.

Ve tr ours, Y' -

O. W. Dixon, r.

ARK:0WD:dwr Attachments cc: See Page Three

Mr. Harold R. Denton Inservice Inspection Program Page Three

  • November 10, 1982 cc: V. C. Summer G. H. Fischer H. N. Cyrus T. C. Nichols, Jr.

O. W. Dixon, Jr.

M. B. Whitaker, Jr.

J. P. O'Reilly (w/ attach)

H. T. Babb D. A. Nauman C. L. Ligon (NSRC) (w/ attach)

W. A. Williams, Jr.

R. B. Clary (w/ attach)

O. S. Bradham A. R. Koon (w/ attach)

M. N. Browne G. J. Braddick (w/ attach)

J. L. Skolds (w/ attach)

J. B. Knotts, Jr. (w/ attach)

B. A. Bursey (w/ attach)

NPCF File (w/ attach) l l

l l

Page 1 'of 20 SYSTEtt VALVE tlUt1BER CHAllGE REA30tl FOR CHAT 10E 1

AC XVG-7501 Stroke To correspond with Tech XVG-7502 Time Spec Stroke Time.

XVG-7503 Attachment I, Page 1 XVG-7504 i

l r

ih9,,

O l

u A

g.

Page 2'of 20 S YSTEf1 VALVE flUt1BER- CHAT 1GE REASOff FOR CHA11GB BD XVG-503A Stroke Time To correspond with Tech XVG-503B- Specs XVG-503C Category A to B GTP-002 Deleted Attachment I, Page 3 Leak Test Requirement i

(

i l

O 4m

  • - - Pago 3 of 20 SYSTEtt VALVE flUt1BER CHANGE REAS0i! FOR CHANGE CC XVG-9605 Stroke Time To correspond with Tech XVG-9606 Spec  !

XVG-9568 XVG-9600 GTP-002 Attachment I, Pages 4 & 5 4

.]

I il i }

l I

^

i

Pc;ge 4 of 20 1

S YSTE!! VALVE, flUffBER CHAtlGE REASOli FOR CHAllGE .

CS XVT-8152 Stroke Time To correspond to' Tech

XVT-8149A Specs.

XVT-8149B.

XVT-8149C GTP-002 '

XVT-8103 XVT-8112 Attachment I, Page 8 CS XVT-8100 Relief Request relief.to stroke XVT-8112 Request Test valves during cold shutdown - cannot secure RCP: Seal Water during plant operations.

GTP-002 Attachment I, Page 8 CS XVG-8106 Deleted Valves do not receive a XVG-8109A From signal and are always

, XVG-8109B- . Program open. Thus Category B XVG-8109C Passive valves - deleted from attachment i CS LGV-115B Stroke Changed stroke time from-LCV-115D Time 10.to 14 seconds based upon Preservice/ Baseline Tests.  !

GTP-002 )

Attachment I, Page 9 CS XVR-8117 Moved to Moved valve from Appendix Section XI J to Section XI to ensure l valve is lift tested and l leak tested.

Attachment I, Page 11 GTP-002 i

\

l \

~~

I

{'

l.

(

i

  • I .,

p Page 5 pf 20 l

S YSTE!! VALVE flUt1BER CHANGE REAS0ll FOR CHANGE /

FS' XVG-6797 Stroke Time To correspond with ..

Tech Specs GTP-002 t, I

Attachment I, Page 18 ,

t I-

'l

/

}

f f

t

  • m a

s t

Page 6 of 20 S YSTE!! VALVF. flUf1BER CHANGE REASOt! FOR CHAllGE l

FW XVK-1633A Stroke Time To corresoond with-XVK-1633B Tech Spec's XVK-1633C GTP-002 Attachment I, Page 19 i

e 4

P,agni7 of 20 S YSTEtt VALVE ;1 UMBER CHANGE REAS0tl FOR CHANGE r

IA XVG-2660 Stroke Time To correspond with

XVG-2662A Tech Specs XVG-2662B GTP-002 Attachment I, Page 21 i

a G

+,

3 Page 8 o'f 20 N S YSTEf1 VALVE fluf1BER CHAtlGE REASOll FOR CHA!JGE ND XVD-6242A Stroke Time To correspond with XVD-6244B Tech Specs GTP-002 Attachment I, Page 26 8

i l

1 b

I Page.9 of 20 S YSTEf1 VALVs NUf1 Belt CHAf1GE REASOff FOR CHAtlGE RC XVT-8095A Category A Not Containment Isolation XVT-8095B to XVT-8096A Category B XVT-80968  ;

Stroke Time Changed from 16 to 23 seconds after engineering approval.

GTP-002 Attachment I, Pages 27 & 28 RC PCV-445A Stroke Test Stroke test at cold PCV-443B Relief shutdown. If valve were PCV-444B Request to fail closed during plant j operation, some overpressure I protection would be lost. I GTP-002 l Attachment I, Page 28 t

1 i

l l

n-

Page 10'of 20

  • ~

S YSTEl! VALVS flUMBER CHANGE REASoll FOR CHANGE SI XVG-8961 Stroke Time To correspond with XVG-8971 Tech Specs 8 XVG-8880  !-

XVG-8860 GTP-002 i Attachment I, Page 34 & 35 L SI XVG-8888A From Categor:r To correspond with FSAR XVG-8888B A to Categor:r Revision.

XVG-8889 B .

GTP-002 Attachment I, Page 38 SI XVG-8801A From To correspond with FSAR XVG-8801B Category A Revision.

XVG-8885 to Category j.

XVG-8884 B GTP-002  ;;

, XVG-8886 .

Attachment I, Page 31 SI XVC-8940A Added to Verify closing of valves XVC-8940B Program as per NRC Comments.

Category C GTP-002 Attachment I, Page 38 & 39 1

J 4

l w_ 4

P, age 11 of 20 S YSTEf1 VALVE flUtfBER CHANGE REAS0tl FOR CHANGE  ;

SP XVC-3013A Added To inccrporate NRC l XVC-3013B Relief Comments. j' Request K-3 GTP-002 Attachment I, Page 41 l

l i

I 4m __ ]

Pagp>12.of 20 S YSTEf1 VALVE flUMBER CHANGE REASON FOR CHANGE SS XVA-9311A Stroke Time To correspond with XVA-9311B Tech Specs- i XVA-9312A i XVA-9312B GTP-002 XVM-9356A XVM-9356B Attachment I, Pages 43, 44

. XVM-9357 and 45 XVM-9364B XVM-9365B XVM-9364C XVM-9365C XVM-9398A i

XVM-9398B

=XVM-9398C XVM-9387 XVM-9339 XVT-9341 i I

SS XVM-9393A From To correspond with_ Tech XVM-9398B Category A Tech Specs XVM-9398C- to Category B GTP-002 Attachment I, Page 44 ~

1

\

bh- u

l

. . Page 13 of 20 S YSTEf1 VALVE hut 1BER CHANGE REASON FOR CHANGE CS XVT-8102A Deleted From Cateogry A Passive XVT-8102B from To Category B Passive XVT-8102C Appendix J No test required XVT-8368A Testing on B Passive Valves XVT-8368B Program XVT-8368C Per NRC Phone call on 9/13/82 0

l

\.

mm k

, . Pcg2 14 of 20 S YSTE!! VALVE flUt1BER CHANGE REASOff FOR CHANGE DN XVD-8767 Added These valves are Appendix J XVD-8768 Valves to Tested.

Program GTP-002 Attachment I, Page 59 l

l I

9 m

Pago 15 of 20 SYSTEli VALVE NUf1BER CHANGE REASOli FOR CHANGE HR XVX-6051A Moved valves Valves no longer receive XVX-6031B to Appendix emergency saf3 guard signal XVX-6051C J testing XVX-6032A Program GTP-002 XVX-6052B XVX-6053A Attachment I, Page 60.

XVX-6033B d

1

-r i

i

  • i Pega 16.of 20

~

S YSTEf! VALVE flUt1BER CHA11GE REAS0t1 FOR CHAllGE IA XVT-2680 Added valves Valves are in Appendix J XVT-2679 to Appendix Tested.

J Testing Program GTP-002-Attachment I, Page 61 4

5 6 a F a i

i f'

m ,

sing lw .

Page 17.of 20 S YSTEf t VALVE flUt1BER CHA?!GE REAS0l! FOR CHAf1GE NG XVG-6587 Added Valves are Appendix J XVC-6588 Valves to Tested.

Appendix J Testing GTP-002 Program Attachment I,.Page 62 w-

, . Pago'18 pf 20 S YSTEf1 . VALVE flUt1BER CHAtlGE REAS0il FOR CHAllGE SF XVD-6671 Added~ valves Valves are Appendix J XVD-6672 to Appendix . Tested.

XVD-6697 J Testing XVD-6698 GTP-002 Attachment.I, Page 6'5 9

8 e

l l' -

Paga 19 of 2'O S YSTEf1 VALVE fluf13ER CHAT 1GE REASoll FOR CHAllGE WL XVD-7135 Added valves Valve is Appendix J to Appendix Tested.

J Testing.

GTP-002 Attachment I, Page 66

.~

Pega 2,0 of 20 S YSTEf t . VALVE T1Ut1BER CHANGE REAS0il FOR CHANGE

' FS XVG-6772 Added valves Valves are Appendix J XVG-6773 to Appendix Tested.

J Testing.-

GTP-002 Attachment I, Page 67

\.