U. S. P3UCLEAR REGULATORY COMunSSioN r.nt*rORt.1[6G (7 77)

LICENSEE EVENT REPORT co visot etOcx: l l l l l l (PLE ASE PRINT OR TYPE ALL REQUIRED INFORMAriONI 101:1 Lal LI al ni Pl il@l 0101 14 5 10101010101 LicEr. E r.vvoEH 10101@!4li11111il@l h 26 LICP.3E TYPE JG I

Si CAI $$

l@

l o a Lactr.3EE C .,6E Corr t lol1I sl ".[gjl Ll@l Ol 510l COCK 01013l 4 l 8 @l 68 I69l 012 l7 Ek ENT l 7 l 8 l@l1 l1REPORT D ATE 74 7$ l2 l01718 DATE 80l@

7 6 60 61 ET NU*.tBER EVENT DESCRIPTION AND PRO 8 ABLE CONSEQUENCES h I o l 2 l l While in Mode I the steam line pressure insernnentnrinn ncencinena ufch nrosenrn l Io lal l transmitter PT-484 failed low. Steam pressure Loops 1, 2, 3 Protection Channel II l

[op.:; l was declared inoperable at 2235 on 10/27/78 and placed in the tripped condition. l to is1 I The channel was restored to an operable status at 0033 on 10/28/78. Tech Spec. 3. 3. 2.q lo is l l action statement requirements were met (other protection channels were operable). l l 0 l 7 l l This occurrence had no ef fect on the health and safety of the general public. l gi i 80 I a 9 SYSTEM CAUSE C A:.lSE COMP. VALVE COOE CODE SUS;OCE COMPONENT CODE SUSCODE SUBCODE O o l it al@ I rl@ I c l@ 11 IN is IT la lu l@ LP_jh [Zj h 1;J 12 13 18 19 20 7 8 9 11 SEQUENTI AL OCCURRENCE REPORT REVISION

,_ EVE?.T vE A R R EPORT NO. CODE TYPE NO L

@ g.ER'gAO17 I a I l-l 10 18 10 I l/l 10131 Lt_1 l---J l_0_J

_2n 22 23 24 26 27 23 29 30 34 32 TAK N ACT ON ON P ANT T HOURS 22 SB IT FO 9. 5 PPLIE ' MA F C RER gg lClgl34Z lg l35Z lg l [N Jg lY l g [N J g lW l1 l2 l0 lg 34 36 3lJ0 l0 l0 l 4J 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS ke Iitol1 Loop power supply isolated /non-isolated (NLP) card PQY-484 (style 2837A12C02) failure.l

[,l3 l l PQY-484 was replaced. The replacement card was calibrated and the ch nnel functionally

- , j tested in accordance with FNP-1-STP-213.10. Other NLP card failures have been reportej l in LER's 78-025/03L-0 and 78-052/03L-0. l I

tile iI l 8 9 80 STA S *. POWE R OTHER STATUS IS O R DISCOVERY OESCRIPTION li is I LEjg l 1 l 0 l 0 j@l NA l l A [gl NA l 80 ACTIVITY CO TENT HELEAsED OF RELE ASE A*.100NT OF ACTivtTY LOC ATioN OF RELE ASE R l Zl @ gl it NA u

l l o

NA 83 l

' ~

m i

'.W 'tM H fi Pt. UEf.CHtPTION NA til71 1 01 01 Ol@lZI@l

  • l

' ' ' ,ERsom'L%u'2ES

NUYPER 05SCRIPitON li I, I I 01 01 Ol@l NA 30 l

n r t+ 9 il IJ t OM OF OR DAY AGE f o F ACILt TY TYPE DE SCR,p r a gg NA l lir l u l L, zi@l,a

- EQ ini L>E CHIPTsON N^ i IIIIIIiIiIIIi 81 l L,LL11 - 24 Lb; 81"'] O 8 0 %9 " " "5 C. Hairston. III pnoye: (205)899-5156 2

, _ r: A'.f E .0F. PRE P AH E R U.