p.1 NSD-SAE-ESI-99-390 FARLE? UNITS 1 AND 2 LBB CALCULATION RESULTS DUE TO STEAM GENERATOR (SG) REPLACEMENT 1

AND SG SNUBBER ELIMINATION PROGRAMS j

UNIT - 1 Highest stressed location is at location 1 (reactor vessel outlet nozzle to pipe weld in j

the hot leg). Location 1 was also the highest stress location in the existing analysis.

j Loads Dimensions. Normal Loads and Normal Stress Lccation Outside Thickness Axial Bending Stress Comments Diameter Loads Moment (in.)

(in.)

(kips)

(in.-kips)

(ksi) 1 33.78 2.28 1458 25150 21.6 existing

[

1 33.78 2.28 1554 24380 21.53 new Note: Normalloads of deadweight, normal thermal expansion and pressure are combined by alaebraic sum method.

Faulted Loads and Stress Location Axial Loads Bending Stress Comments Moment (kips)

(in.-kips)

(ksi) 1 1768 30130 25.9 existing 1

1803.76 31586

_ 26.96 new Notes:

1.

Faulted loads of deadweight, normal thermal expansion, pressure and SSE are combined by absor'ute sum method.

2.

Ratio of new faulted stress / existing faulted stress is = 1.04 i.e., new faulted stress is increased by 4.0 %.

Material Properties Matciial Type: SA351CF8A Temperature: 614 F Average Yield Strength = 24642 psi Minimum Yield Strength = 21430 psi Minimum Ultimate Strength = 66470 psi Modulus of Elasticity, E = 25.23E6 psi J

9910290206'991010 PDR ADOCK 05000348 PDR 3,1 p

p. 2 NSD-SAE-ESI-99-390

. 0 C, C.

3 Assessment of A.r if:.9; Margins relative to; a) Flaw Size - Using faulted loads obtained by the absolute sum method, a margin of at least 2 exists between the critical flaw and the flaw having a leak rate of 10 gpm (the leakage flaw),

b) Leak Rate - A margin of 10 exists between the calculated leak rate froni the leakage flaw and the leak detection capability of 1 gpm.

c) 1.oads ' The leakage flaw was shown to be stable using the faulted loads obtained by the absolute sum method. Margin on loads of 1.0 is satisfied.

==

Conclusion:==

All of the recommended LBB margins are satisfied.

p. 3 NSD-SAE-ESI-99-390 UNIT - 2 4

i

- Highest stressed location is at location 1 (reactor vessel outlet nozzle to pipe weld in the hot leg). Location 1 was also the highest stress location in the existing analysis.

Loads Dimensions. Normal Loads and Normal Stress Location Outside -

Thickness Axial Bending Stress Comments Diameter Loads Moment (in.)

(in.)

(kips)

(in.-kips)

(ksi) q 1

33.81 2.30 1456 25150 21.4 existing

)

f 1

33.81 2.30 1554 24380 21.33 new Note: Normalloads of deadweight, normal thermal expansion and pressure are combined by aloebraic sum method.

Faulted Loads and Stress Location Axial Loads Bending Stress Comments Moment (kips)

(in.-kips)

(ksi) 1 1767 30130 25.7 existing 1

1803.76 31586 26.72 new Notes: 1.

Faulted loads of deadweight, normal thermal expansion, pressure and SSE are combined by absolute sum method.

2.

Ratio of new faulted stress / existing faulted stress is = 1.04 i.e., new faulted stress is increased by 4.0%.

Material Properties Material Type: SA351CF8A Temperature: 614*F Average Yield Strength = 22575 psi Minimum Yield Strength = 20217 psi Minimum Ultimate Strength = 66600 psi Modulus of Elasticity, E = 25.23E6 psi i

l

p. 4

~

l NSD SAE-ESI-99-390 l

0,C,8 I

\\

\\

Assessment of Marains l

Margins relative to:

a) Flaw Size - Using faulted loads obtained by the absolute sum method, a

)

margin of at least 2 exists between the critical flaw and the flaw having a leak

)

rate of 10 gpm (the leakage flaw).

l b) Leak Rate - A margin of 10 exists between the calculated leak rate from the l

Ieakage flaw and the leak detection capability of 1 gpm.

l c) Loads - The leakage flaw was shown to be stable using the faulted loads obtained by the absolute sum method. Margin on loads of 1.0 is satisfied.

==

Conclusion:==

All of the recommended LBB margins are satisfied.

t

p. 5 4

NSD-SAE-ESI-99-390 Reactor Pressure Vessel I

e COLD LEG HOT LEG 3

' '- {

l

,3

, g-

\\

Reactor Coolant Pump

\\

Steam Generator CROSSOVER LEG 4

l

=&

Q) p]= @

=4

\\

h h

Schematic Diagram of the Farley Plants RCL Showing Weld Locations