ML20006A757

From kanterella
Jump to navigation Jump to search
1REO1 Inservice Insp Summary Rept for Sys Pressure Tests at South Texas Project Electric Generating Station,Unit 1
ML20006A757
Person / Time
Site: South Texas 
Issue date: 01/09/1990
From: Mcintyre A, Pathak A, Timmaraju S
HOUSTON LIGHTING & POWER CO.
To:
Shared Package
ML20006A751 List:
References
NUDOCS 9001300148
Download: ML20006A757 (20)


Text

e i

COVER SHEET 1RE01 INSERVICE INSPECTION

SUMMARY

REPORT F

FOR SYSTEM PRESSURE TESTS AT THE SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 1 P. O. Box 289 Wadsworth, Texas - 77483 USNRC DOCKET NO.

50-498 OPERATING LICENSE NO.:

NPF-76 COMMERCIAL OPERATION DATE:

AUGUST 25, 1988 e::r> /

/-d9-90 Prepared by: A. P. Fathak Consulting Engineer - Codes & Stds.

Reviewed by:

I' 0 9 /9 9 o S. Timmaraju '

Sr. Consulting Eng. - Codes & Stds.

Approved by:

[l( )W D

/ 9 O A. C. McIntyre' Manager - Support Engineering Dept.

~

r i

4 I

L l

l l

9001300148 900116ADOCK0500g{S PDR Q

l' SCOPE 1RE01 SYSTEM PRESSURE TESTS The examinations summarized in this report were performed in accordance with the 1983 Edition through Summer 1983 Addenda of the ASME Code,Section XI which is applicable to the South Texas Project Electric Generating Station Unit 1.

This report covers selected ASME Code Class 1, 2, and 3 Systems / Components.

Examinations and tests required by the Code are scheduled in accordance with " Inspection Program B" as defined in IWB-2412 and IWC-2412 for ASME Code Class 1 cnd 2 Systems / Components.

All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P which established the examination frequency at each refueling outage.

The ASME Code Class 2 and 3 Systems /Cemponents were selected on a random basis.

This random selection process will continue until all ASME Code Class 2 and 3 Systems / Components are examined'in accordance with Table IWC-2500-1, Examijation Category C-H and Table IWD-2500-1, t

Examination Category D-A and D-B for ASME Code Class 2 and 3 Systems / Components, respectively.

These examination categories for ASME Code Class 2 and 3 Systems / Components established the examination frequency at each inspection period.

The remaining first period examinations are enticipated to be completed by the end of the third refueling outage which should occur within the first period time frame.

The System Leakage Test (IWA-5211(a)) conducted on Class 1 Systems / Components in accordance with Examination Category B-P also satisfied the system pressure test required by IWA-5214 (e) subsequent to the disassembly and reassembly of mechanical joints in ASME Code Class 1 components.

l l

,m m.

i I

i PAGE 1 cf 4 FORM NIS-1 CWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Frovisions cf the ASME Cod 3 RulO3 j

~

J v

1.

Chener )buston Lightira & Wwer Cmpany Elmetric Ttwer, P. O. Ekst 1700, )kuston, n 77001 (Name and Addzess of Owner) 2.

Plant Sxth Texas Project Electric Generatire 1,tation P. O. Box 289, Wadsworth, TX 77483 (Name ard Address of Plant) 3.

Plant Unit i

_ 4.

CWer Certificate of Authorization (if required)

N/A 5.

Ccrirnercial Service Date 08/25/88

6. National Board Naber for Unit N/A

. 7.

Cm ponents Inspected A!ME OIE CLASS 1 FIPDG AND CDENENIS Marufacturer Cm ponent or Manufacturer or Installer State or National Appartenance or Installer Serial No.

Prwinee Ib.

Board No.

REACIm VESSEL CDRETICN BGINEERDG/

1R10116tV101A VIETD G OLISE (M) 11073 N/A 22100 SIM. GENERAE R IR121NS'101A WESTDOCUSE (M) 2131 N/A WlB691 SD1. GENERAKR J

1R121NSG101B WESTDGOUSE (M) 2132 N/A WlB692 SIM. GENERAK R 1R121NEC101C WESTDGOUSE (M) 2133 N/A WlB693 i

SIM. GENERAE R 1R121NSG101D WESTDGOUSE (M) 2134 N/A WIB694 PRESSURIT2R IR111!E2101A WESTDGOUSE (M) 2141 N/A W18590 E PLNP 1R131NPP101A WESTDGOUSE (M) 1-115E580'01 N/A 28 E PLNP 1R131NPP101B VfSTDGOUSE (M) 2-!!5E580301 N/A 29 BC PLNP 1R131NPP101C WESTDGOUSE (M) 3-ll5E5KKD1 N/A 30 RC PLMP 1R131NPP101D WELTDGUJSE (M) 4-Il5ESKKD1 N/A 31 CLASS 1 i-PIPDC EBA!KD (I)

N/A N/A N/A CUCS1 VALVES VARIOUS N/A N/A N/A l-l l

l 1

l l

ICIE: Supplemental sheets in form of lists, sketches, or drawires may be used, provided (1) size is 81/2 in. X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, ard (3) each sheet is runbered ard the tuber of sheets is recorded at the top of this form.

NIS1.CL1.1RE01

L FORM NIS-1 (B:ck)

8. Dusnination Dates 08/25/88 to 11/01/89
9. Inspection Interval frun OB/25/8B to 08/25/9B
10. Abstract of Duminatims. Include a list of exaninations and a statenent concerning status of work required for current interval. Refer to Supplenantal Sheet Page 3 of 4.
11. Abstract of Conditims Hated No relevant conditions affecting pressure retaining boundaries were roted.
12. Abstract of Corrective Measures Reconmended ard Taken Refer to Npplanental Sheet Page 4 of 4.

We certify that the statutents rnade in this report are correct ard the exaninations ard corrective nessures taken cmform to the rules of the ASE Ccde,Section XI.

Certificate of Authorir.atico No. (if applicable)

N/A bcpiration Date N/A Date 0% 4 19 *.)O Signed }kuston Lighting & Power Co. By E d V

Omer 7 W.N. Kins %d Jr.

l QRrIFICA1E & INSERVIG INSPICTI(N I, tre undersigned, holding a valid ccrimission issued by the National Board of Boiler ard Prensure Vessel Inspectors and the State or Prwince of Texas ard enployed by latermens totual Casualty Co.

of law Grove, It

  • /* pected the ccatponents/ 4 80 and state ins described in this N

to Omer's Report during the period that to the best of ny kncwledge ard belief, the Owner has performed exaninations ard taken corrective neasures described in this Owner's Report in accortlance with the inspection plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his enployer makes any warranty, expressed or inplied, concerning the exaninations and corrective measures described in this Omer's Report. Furthernere, neither the Inspector nor his enployer shall be liable in any raanner for any personal injury or property danage or a loss of any kind arising frcrn or connected with this inspection.

1 Conmissions m

~ Inspector's Signature National Board, State, Province, ard Bdorsements Date 19 N8

~

~

NISI.CLI.1RE01

FORM NIS-1 (B:ck)

I

'.8. Busnination Dates 08/25/8B

'to 11/01/89

9. Inspection Intcrval frtso 08/25/SB to 08/25/99
10. Abstract of Emaninetions. Inc1We a list of exaninations and a statement concerning status of work required for current interval. Refer to Supplenantal % set Page 3 of 4.
11. Abstract of Ccaditicos Noted No relevant conditions affecting pressure retaining bourdaries were noted.
12. Abstract of Corrective Measures Fecerananded and Takan Refer to Supplanental Sheet Page 4 of 4.

We certify that the statements inade in this report are correct and the examinations and corr-etive measures taken conform to the rules of the ASE Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Dste Nh 4 19 *jo Signed Ibuston Liahting & Power Co. By M d V

Owner 7 W.N. Kir @ Jr.

GRTIFICAIE T INSERVI3 DEPB7ICN 1, the undersigned, holding a valid catrnission issued by the National Board of Boiler and Pressure Vessel l

Inspecten aM the State or Prtnince of Texas and enployed by 1Arnbermens tintual Casualty Co.

of long Grove, IL the cenpanents described in this Demer's Report during the period

  • /*

to

/ 4 -ff0 and state that to the best of try knowledge and belief, the Damer has performed exaninations and taken corrective treasures described in this Owner's Report in accordance with the inspection plan aM as riquired by the A!HE Code,Section XI.

By signing this certificate neither the inspector nor his enployer makes any warranty, expressed l

or inplied, concerning the exaninations aM corrective measures described in this Owner's Report. Ibrthernore, neither the Inspector nor his anployer shall be liable in any manner for any persczuti injury or property damage or a loss of any kird a. rising fran or connected with this inspection.

Cannissions m

~ fisiipector's Signature National Board, State, Province, and Ihdorsements Date 19 b

~

~

NISI.CLI.1RE01

PAGE 3 cf 4 SUPPLEMENTAL FOR i

ASME CODE CLASS 1 PIPING AND COMPONENTS i

1.

Omner _ }bustan Liahtira & Power Cmpany Electric hwer, P. O. Box 1700. )buston, n 77001 l

(Nans and Address of Olmer) 2.

Plant South hxas Project Electric Generatira Station P. O. Bax 289. Wadsworth, n 77483 (Nane and Address of Plant) 3.

Plant thit 1

4.

Owner Certificate of Authoritation (if requitsd)

N/A i

5.

Camercial Service Date 08/25/88

6. National Board Nanber for thit N/A
10. ABSTRACT OF EXAMINATIONS A System Leakage Test as proscribed by IWA-5211(a) for all ASME Code Class 1 Pressure Retaining Components was conducted in accordance with Table IVB-2500-1 Examination Category B-P, Item Nos. B15.10, B15.20, B15.30, B15.40, B15.50, B15.60 and B15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with IPSP15-RC-0001, Reactor Coolant System Leakage Pressure Test (Rev. 2) at the conclusion of the first refueling outage.

ASME Code Class 1 piping and valves are specifically identified in the above referenced procedure.

In addition, the above System Leakage Test also satisfied the requirement for a System Pressure Test subsequent to the disassembly and reassembly of mechanical joints in ASME Code Class I components as prescribed by IWA-5214(e).

Also, System Pressure Tests s.ubsequent to the disassembly and reassembly of mechanical joints in ASME Code Class I components as prescribed by IWA-5214(e) were conducted in accordance with OPGP03-ZE-0027, ASME Section XI Post-Maintenance Pressure Tests (Rev. 2) for individual work items performed outside the scope of the first refueling outage.

NISI.CL1.1RE01

-}

PAGE 4 cf 4 l

SUPPLEMENTAL FOR ASME CODE CLASS 1 PIPING AND COMPONENTS i-l.

Owner Hcustm Lishtira & Power Canpany Electric Tower, P. O. Box 1700, }tusten, H 77001 (Nam and Address of Owner) 2.

Plant South kvas Project Electric Generatira Ststion P. O. Box 280, Wadsworth, H 77483 (Nem ard Address of Plant) 3.

Plant thit i

4.

Owner Certificate of Author 1 ration (if required)

N/A S.

Camercial Service Date 08/25/88

6. Natimal Board Ranber for thit N/A l
12. ABSTRACT OF CORRECTIVE MEASURES RECOMMEtiDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued system operation. Appropriate corrective action was initiated to correct these leaks.

1

'NISl.CL1. IRE 01

PAGE 1 cf 5 FORM NIS-1 OWNER'S REPOPT FOR IZSERVICE INSPECTIONS As required by the Provision] cf the ASNK Cod) RulO3 1.

Cwner Ruston Lightira er Power Ccripany Eloetrie 'Idwer, P. O. Ikm 1700, Ruston, TX 77001 (Nane and Address of Chener) 2.

Plant S:uth hxas Project Electric Generatira Station P. O. Ikw 280, Wadsworth, 'IX 77483 (Nane ard Address of Plant) 3.

Plant Unit 1

4.

Chmer Certificate of AJthorisation (if required)

N/A 5.

Camercial Service Date 08/25/88

6. National Board Naber for thit N/A 7.

Ccripcments Inspected ASE CIKE CLASS 2 PIPIN3 A2 ONCNENTS Manufacturer Caiponent or Manufacturer or Installer State or Naticmal ppurtenance or Installer Serial No.

Prwinee No.

Board No.

PWST 1A i

2N121 NIT 101A BION MD4FAMLIS (M) 1100-15 N/A N/A HEI M 1A 2N1211FA101A PACInc PMS (M) 51605 N/A 382 NEI PMP IB 2N121NPA101B PACITIC P M S (M) 51606 N/A 383 ntSI INP IC 2N121NPA101C PACIMC MHPS (M) 51700 h/A 402 INSI 1HP 1A 2N121NPA102A PACITIC MHPS (M) 51701 N/A 420 IRSI PliP IB 2N121NPA102B PACIMC MHPS (M) 51702 N/A 421 i

INSI INP IC 2N121NPA102C PACIM C M HPS (H) 51703 N/A 422 CS INP 1A 2N101NPA101A PACInc MNPS (M) 51707 N/A 441 CS PHP IB 2N101NPA101B PACIFIC M HPS (M) 51708 N/A 442 CS INP IC 2N101NPA101C pas *ITIC M NPS (H) 51709 N/A 443 SI #C 'IK 1A 2N121NRC101A SOUIMEST FAB (H) 0043 N/A 362 SI ACC 'IK IB 2N12D@C101B S'UIHWEST TAB (M) 0044 N/A 363 SI ACC 'IK IC 2N121NR0101C SOUI1MEST FAB (M)

(045 N/A 364

~

CS EDGR 1A

{

2N101NED101A EBA930 (I) 220 N/A N/A CS 12UCIm IB 2N10lNED101B H W ED (I) 230 N/A N/A CS E:1.CIm IC 2NIO MED101C EEASED (I) 225 N/A N/A NOIE: Supplemental sheets in form of lists, sketches, or dravirgs may be used, prcvided (1) size is 81/2 in. X 11 in., (2) information in itens 1 thrw3h 6 on this report is included on each sheet, and (3) each sheet is trabered and the trJmber of sheets is recorded at the top of this form.

NIS1.CL2.1RE01

PAGE 2 cf 5 e

TORM NIS-1 (B ek)

6. Eksnination Dates 07/17/89 to

!!/01/89

9. Inspection Interval fran 0B/25/88,to 08/25'/98
10. Abstract of Durninations. Include a list of ourninatims and a statenent concerning status of work required for current interval. Refer to ibpplanantal Sreet Page 4 of 5.
11. Abstract of Cmditions Noted No relevant conditions affectirg pressure retain 1ng boxdaries were noted.
12. Abstract of Corrective Measures beenmerded ard Taken Refer to Supplanental Steet Page 5 of 5.

We certify that the statenrsnts made in this report are correct and the exaninations ard corrective naasures taken conform to the rules of the ASE Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date Ah N

19 % Signed _ Mxsten Lighting & Power Co. Bydk CWner gV W.' H. VQ, Jr.

1 V

QRTIFICA3E (F INSERVICE IttiPICTICN I, the undersigned, tolding a valid cenission issued by the National Board of Boiler ard Pressure Vessel Insrectors and the State or Prwince of hxas and enployed by hanbermans Matual Casualty Co.

of long Grwe, IL have inspected tie conponents described in this Owner's Report during the period

//'"/*A9 to

/~./ - MONF and state that to the best of ny knowledge and belief, the CWner t.as perforned exaninations and taken corrective measures describad in this Owner's Report in accordance with the inspection plan and as required by the A9E Code,Section XI.

By signing this certificate neither the Inspector nor his enployer makes any warranty, expressed or inplied, concerning the exaninations and corrective neasuris described in this CWner's Report. Furthernere, neither the inspector nor his unployer shall be lisble in any manner for any rersonal irduty or property damage or a los an kind arising frun or connected with this inspection.

~

Cenissions I d $2f, inspector's Signature National Board, State, Prwince, and Endormenents Date

/" Y-

_19 9C l

l l

f i

NISI.CL2.1RE01 l

l l

l-

i FORM NIS-1 (Back)

8. Emaninetim Dates 07/17/89 to 11/01/89 9.1:wrpection Interval frtrn 08/25/'1 to 08/25/?1
10. Alstract of Durninatims. Include a list of exaninations and a statenant concerning status of work regaired for current interval. Refer to SLpplenantal Sheet Page 4 of 5.
11. Abstract of Ccrditions Noted l

No relevant conditions affecting pressure retaining beundaries were noted.

12. Abstract of Corrective Measures Roccrmanded ard Taken Refer to Supplanental Sheet Page 5 of 5.

%e certify that the staternants inade in this report are correct and the exaninations ard corrective rusasures taken confonn to the rules of tJe A9E Code,Section XI.

Certificate of Authorisation No. (if applicable)

N/A Dcp1 ration Date N/A Date_ Eh

'4 19 3 0 Signed buston Lighting er Power Co. By.

~

U Omer W.'H.KirQ,Jr.

~

CIRrIFICA3E T INSERVICE INSPETI(N I, the urdersigned, holding a valid ccurrnission issued by tJe National Boartl of Boiler and Pressure Vessel Inspectors ard the State or Prevince of Texas aM anployed by 11rnbennens Wtual Casualty Co.

of Innt Grtwe, IL have inspected the certponents descrited in this Omer's Report during the period

//'/-89 to

/- /- M ON f*

aM state that to the test of ny knculedge aM belief, the Oeer has performed exaninations and taken corrective naasures descrited in this Omer's Report in accortlance with the inspection plan and as regaired by the A!HE Code,Section XI.

By signing this cenificate neither tJe Inspector nor his enployer makes any warranty, expressed or inplied, concerning the exaninations ard corrective rueasures described in this Omer's Report. Furthennore, neitJer the Inspector nor his a:ployer shall be liable in any rnanner for any personal irdury or property damace or a los an kird arising frtru or connected with this inspection.

Conmissions IdM inspector's Signature National Boarti, State, Pituince, and Bdorsenents Date

/~ Y*

19 9C NISA.CL2.1RE01

PAGE 3 cf 5 i

SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS i

1.

Chmer _ Mcuston Lishtira er Power Cmpany Electrie 7dwer, P. O. Besc 1700, }kustcm, TK 77001 (Nate and Ackiress of Chmer) 2.

Plant Scuth Texas Project Electric Generstire Station P. O. Box 289, Wadsworth, 'IX 77483 (Nans and Ackiress of Plant) 3.

Plant thit 1

4.

Owner Certificate of Authorization (if required)

N/A I

S.

Ccamercial Service Date 8/25/88

6. National Board Nanber for thit N/A Manufacturer I

Caponent or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province W.

Board W.

Class 2 Pipira EBA9]O (I)

N/A N/A N/A i

Class 2 valves V W OUS N/A N/A N/A 1

l l

l 1

l l

l NISA.CL2.1RE01

PAGE 4 cf 5 SUPPLkNENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS 1.

Owner Mcuston Liahtira & Power Ccmpany Electric hr, P. O. Box 1700, Ituston. 'IX 77001 i

(Name and Addssa of Chmer) 2.

Plant _ South hxas Project Electric Generatire Station P. O. Box 289. Wadsworth, TX 77483 (Neo and Addrwas of Plant) 3.

Plant thit 1

4.

Owner Certificate of Autlerization (if required)

N/A 9

5.

Camercial Service Date 08/25/88

6. National Boart! Nanber for 11 nit N/A 10.

ABSTRACT OF EXAMINATIONS I

System Functional Tests as prescribed by IWA-5211(b) were conducted on selected ASME Code Class 2 Pressure Retai.11ng Systems / Components in accordance with Table IWC-2500-1, Examination Category C-H, Item

(

Nos. C7.10, C7.30, C7.50, and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted in accordance with IPSP15-CS-0001, Containment Spray System Functional Pressure Test (Rev. 3) and IPSP15-SI-0001, safety Injection System Functional Pressure Test (Rev. 3).

ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures.

The above test procedures were conducted during the time period of July 17, 1989 to November 1, 1989.

NISA.CL2.1RE01

PAGE 5 Cf 5 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS g

1.

Chmer _ Ibuston Lightira In Power Cdwany Eloetrie 7bwer, P. O. Best 1700, }buston, TX 77001 (Nme ard Address of Chener) 2.

Plant _ Scuth Texas Pmject Electric Generatire Station P. O. Box 280, Wadsworth, 2X 77183 (Nas ard Addreas of Plant) 3.

Plant Unit 1

4.

Owner Certificate of Auttorization (if required)

N/A 5.

Comnertial Service Date 08/25/88

6. National Board Mmber for thit N/A
12. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections.

These leaks were evaluated and determined acceptable for continued system operation.

Appropriate corrective action was initiated to correct these leaks.

~

NISA.CL2.lRE01

PAGE 1 cf 9 FORM NIS-1 OWER'S REPORT FOR INSERVICE INSPECTIONS As requir:d by the Provisions of the ASME Cod) R"l;1 9 1.

Cheer _ ltuston Lightirut & Power Chipany Electric hr, P. O. Ikot 1700, )tuston, E 77001 (Neie and Address of Owner) 2.

Plant Scuth Texas Project Electric Generatitut Station P. O. B:n 289 Wadsworth, TK 77483 (Nam and Address of Plant) 3.

Plant mit 1

4.

Owner Certificate of Autforization (if required)

N/A 5.

Ccrme:1:ial Service Date 08/25/88

6. National Board N,snber for ilnit N/A 7.

Cartponents inspected ASE (DDE CIJSS 3 FIPDG AND OMOBfIS Manufacturer Ca ponent or Manufacturer or Installer State n National Appartenance or Installer Serf al No.

Prwinee No.

Board No.

R(M INP 1A 3R271t@A101A IRWARD TAWDR 812701 N/A 64 RiW INP IB 3R271NPA101B HAWARD TARDR 812702 N/A _

65 R WST 1A 3R271NIF101A BION MDNPAIOLIS 1100-05 N/A N/A CH EKPANSIQ4 2K 3Vil1VISO%

RPID I!CUSIRIES N-2536-10 N/A B1426 Of EKPANSIQ1 E 3VI1IVTS005 RFDO DOUSIRIES N-2536-20 N/A 81427 Of EXPANSIO4 E 3Vil!VIS006 REED DOUSIRIIS N-2536-30 N/A 81430 A}U SV111VHX026 AMERICAN AIR FIIMR 906438-N1 N/A 2381

  1. U 3v111VHX025 AMERICAN AIR FIIMR 906438-11-1 N/A 2361
  1. U 3V111VHX024 AMDUCAN AIR FIIMR 906438-J1 N/A 2363
  1. U 3VillVHX016 AMERICAN AIR FIIMR 906438-K2-1 N/A 2368
  1. U 3VlllWN017 AMERICAN AIR FIIMR 906438-K2-2 N/A 2369
  1. U 3VlllWN018 AMERICAN AIR FIL'ITR 906439-K2-3 N/A 2370 MU 3VillW N007A AMERICAN AIR FIIMR 906048-Al N/A 1724
  1. U 3VillWN007B AMERICAN AIR FIIMR 906048-A2 N/A 1725
  1. U 3V111VHX010A AMERICAN AIR FIIM R 906948-A5 N/A 1728
  1. U 3VI1IVN010B AMERICAN AIR FIIMR 906948-A6 N/A 1729 ICIE: Supplemental sheets in fem of lists, sketches, or drawings may be used, prwided (1) site is 81/2 in. X 11 in., (2) infomation in itens 1 thrtugh 6 on this report is inclu: led on each sheet, and (3) each sheet is rusobered and the rnsuber of sheets is recorded at the top of this fom.

NISA.CL3.1RE01

PAGE y cf 9 FORM NIS-1 (B ck)

8. Busninatico Dates 07/17/89 to 11/01/89
9. Inspection Interval fran OB/25/88 to 08/2.5/dB
10. Abstract of Burninaticas. Include a list of examinations and a statement concerning status of work required for current interval. Refer to Supplemental Sheet Page 8 of 9.
11. Abstract of Conditims Noted i

No relevant conditims affecting preasure retaining boundaries were noted.

i

12. Abstract of Cortictive Haasares Recersnanded and Taken Refer to Npplanantal 9eet Page 9 of 9.

.i We certify that the statenents rnade in this report are correct and the exaninations and corrective naasures taken conform to the rules of the /&E Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A bcpiratim Date N/A r

Houston Lighting &

Date MW N 19% Signed Power comenny By M M b b s

V Owner

" W. H. Y ey, Jr.

CIRrIFICA2E & INSERVI2 IMSPILTICN I, the undersigned, holding a valid ccmnission issued by the National Board of Boiler and Pressure Vessel Inspectnrs and the State or Province of Texas and anployed by 11:nbernens Matual Casaalty Co.

of long Grove, IL have inspected the conponents described in this Omer's Report during the period

//- / <$ 9 to

/~ 4-90 ard state l

that to the best of ny knowledge and belief, the Owner has perfonned exaninatims and taken corrective neasures described in this (kner's Report in accordance with the inspection plan and as required by the A&E Code,Section XI.

By signing this certificate neither the Inspector nor his enployer makes any warranty, expressed or inplied, concern exaninaticos and corrective neasures described in this Owner's Report. Furtiermore, neither the Inspec r nor a at.ployer shall be liable in any manner for any personal irdury or property damage or a loss f any k arising frorn or connected with this inspection.

l 1

Catmissions N dNa

- '=-

Inspector's Signature National Board, State. Province, and Briorsetents Date

/- # -

19 90 l

l l

l l

NISI.CL3.1RE01

6 r

FORM NIS-1-(Back)

8. Buninetim Dates 07/17/89 to 11/01/89
9. Inspection Interval 12rcro 08/A5/03 to 0B/25/98
10.. Abstract of Enaninations. Include a list of exaninations and a staternent concerning status of work regaired for current interval. Refer to Sgplernantel Reet Page 8 of 9.
11. Abstract of Corditions !bted No relevant conditions affecting pruasare retainirig bourdaries were noted.
12. Abstract of Corrective Measures Reccrsnarded ard Taken Refer to Supplernantal Reet Page 9 of 9.

We certify that the statener,ts innde in this report are correct ard the exaninaticns afd corrective measures taken conform to the rules of the ASE Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Ekpiration Date N/A r

Houston Lighting 6 Date Auw 4 191 Signed Power conrsnesv By l

V Omer H. Y ey, Jr.

QRTIFICE T INSERVI2 INSPICTICN I, the undersigned, holding a valid ccrtrnission issued by the National Board of Boiler ard Pressure Vessel Inspectors and the State or Prwince of Texas ard eriployed by 1Arnbernens mtual Casualty Co.

of long Grwe. It have inspected the ccrponents described in this Owner's Report during the period

//- / f6 F to _ /~ 4-FC and state that to the best of rrtf knowledge and belief, the Omer has performed exaninations and taken corrective naasures described in this Cwner's Report in accortiar'ce with tre inspection plan and as regaired by the MNE Code,Section XI.

By signing this certificate neither the inspector nor his artployer rankes any warranty, expressed or inplied, concernirgexaninations and corrective neasures described in this Omer's Report. Furtherwore, neither the Inspec}er nor it s eriployer shall be liable in any manner for any personal irdury or property dsnage or a loss f any k arisir6 frtro or connected with this inspectico.

Ccrrmissions

~/ I d M Inspector's Signature National Board, State, Prwince, and Erdorsements Date

/- / -

19 90 i

i i

l I

i i

l l

i NISA.CL3.1RE01 1

PAGE 3 cf 9

' ~

SUPPLIMENTAL FOR ASME CODE CLASS 3 PIPING AND COMPONENTS 1.

Omer Houston Liahtira & Power Ccmpany Electrie 'Itwer. P. O. Besc 1700, }kustm TX 77001 (Name ard Addreas of Owner) 2.

Plant South Texas Project Electric Guratire Station P. O. Besc 289. Wadsworth, TX 77483 (Name and Address of Plant) 3.

Plant W it 1

4.

Owner Certificate of Autterization (if required)

N/A 5.

Canarcial Service Date 08/25/88

6. Natimal Board Ntsnter for thlt N/A Manufacturer Coganent or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

  1. U 3V111% dol 3A AMERICAN AIR FIL'ITR 906048-A9 N/A 1732 NU 3VillWD013B
  1. ERICAN AIR FILTilR 906948-A10 N/A 1733
  1. U 3V10lVAK)07
  1. ERICAN AIR FILTTR 906438-Al N/A 2329
  1. U 3V101VM008
  1. ERICAN AIR FI11tTR 906438-B1-1 N/A 2333
  1. U 3VllVAFOO9 AMERICAN AIR FILTER 906438-B2-1 N/A 2335
  1. U 3V101V#010 AMERICAN AIR FILTER 906438-Cl N/A 2337 l
  1. U 3V101VM011 AMERICAN AIR FILTTR 906438-A2 N/A 2330
  1. U 3V10lVM012 AMERICAN AIR FIUTR 906438-Dl-1 N/A 2339
  1. U 3V10lV#013 AMERICAN AIR FIlaTR 906438-D2-1 N/A 2341
  1. U 3V10lVM014 AMERICAN AIR FIlaTR 906438-El-1 N/A 2343
  1. U 3V10lVM015
  1. ERICAN AIR FIISTR 906438-E2-1 N/A 2345
  1. U 3v10lVM016
  1. ERICAN AIR FILTER 906438-F1-1 N/A 2347
  1. U 3V10lVMOl8
  1. ERICAN AIR FIIaTR 906438-F2-1 N/A 2349
  1. U 3V10lVMOl9
  1. ERICAN AIR FIIa1R 906438-Gi-!

N/A 2351

  1. U 3V10lVNO20
  1. ERICAN AIR FIIa1R 906438-Gi-2 N/A 2352
  1. U 3V10lVM021
  1. ERICAN AIR FIl3TR 906438-Gi-3 N/A 2353 l

l.

NIS1,CL3.1RE01

r-PAGE 4 cf 9 SUPPLENENTAL FOR ASME CODE CLASS 3 PIPING AND COMPONENTS 1.

Chmer Houston Liahtira & Power Ccmpany Electric Tdwer, P. O. Best 1700, }tustcm. TX 77001 (Nate and Address of Owner) 2.

Plant _ South Texas Project Electric Generatira Station P. O. Best 289, Wadsworth, 'IX 77483 (Nans and Addreas of Plant) 3.

Plant tAtit 1

4.

Owner Certificate of Authorization (if required)

N/A 5.

Camercial Service Date 08/25/88

6. Naticnal Boarti Rather for thlt N/A Marufacturer Ccmponent or Marufacturer or Installer State or National Amurtenance or Installer Serial No.

Province Ib.

Board No.

  1. U 3V10lVM022 AMERICAN AIR FIL71R 906438-M1 N/A 2357
  1. U 3v101VM023 AERICAN AIR FILTTR 906438-H2 N/A 2358
  1. U 3V121V#010
  1. ERICAN AIR FILTTR 906438-12-1 N/A 2373
  1. U 3V121V#0l!

AMERICAN AIR FIISTR 906438-L1-1 N/A 2371

  1. U 3V121V#012 A E RICAN AIR FI12TR 906438-M1-1 N/A 2375
  1. U 3V121V#013 AMERICAN AIR FILTTR 906438-M1-2 N/A 2376
  1. U 3V121VM014
  1. ERICAN AIR FILITR 906438-MI-3 N/A 2377
  1. U 3V121VHX012A
  1. fRICAN AIR FI12TR 906948-K1 N/A 1772
  1. U 3V121VHX012B
  1. ERICAN AIR FIlaTR 906948-K2 N/A 1773
  1. U

_3V121VHX013A

  1. ERICAN AIR FI12TR 906948-K3 N/A 1774 NU 3V121VHX013B
  1. fRICAN AIR FIISTR 906948-K4 N/A 1775
  1. U 3V121VHX014A AMERICAN AIR FIISTR 906948-K5 N/A 1776
  1. U 3V121VHX014B AMERICAN AIR FILITR 906948-K6 N/A 1777 ESS OHL1JiR 11A 3Villv0001 B3GNA7NER 93090 N/A 54521 ESS -OU11JiR 1IB 3VII190002 BOR3-WARNER 93089 N/A 54560 ESS QUILER llc 3V11190003 BORMIAINER 93088 N/A

$4645 l

t NIsl.CL3.1RE01 i~

PAGE 5 cf 9 SUPPLEMDiTAL FOR ASME CODE CLASS 3 PIPING AND COMPONENTS 1.

Owner buston Liahtira & Power Ccmpany Electric 'Ibwer, P. O. Ban 1700, }kuston, R 77001 (Name and A&iress of Nner) 2.

Plant South Texas Project Electric Generatire Station P. O. Box 289, Wadsworth, TX 77483 (Name and Akiress of Plant) 3.

Plant thit 1

4.

Nner Certificate of Authorization (if required)

N/A 5.

Cometrial Service Date 08/25/88

6. National Boan! Ntaber for thit N/A t

Marnfacturer Cenpanent or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

P,rovince No.

Board No.

ESS O{IIJRt 12A 3Vil1VO004 B3G-WARER 4-1857 N/A 573 %

ESS QC112R 128 3VillV0005 B3G-WAR 4ER 4-1856 N/A 57397 ESS O{ILIJ!R 12C 3VI11V0006 BOGWARER 4-1858 N/A

$7395 ESS Of M 11A 3Vil!VPA004 BTrYN JADcDI 841-H-0006 N/A 49 ESS Qi ItF 11B 3V111VPA005 BYIEN JA03N 841-H-0007 N/A 51 ESS 01 PHP llc 3VillVPA006 BYIEN JAOcKN 841-H-0006 N/A 53 SPY AID TK 1A M10lNTS101A REDO INDLEIRIES N2330-10 N/A 73877 SPY AID E IB W10lNIS101B RED INDLEIRIES N2330-20 N/A 73878 SPY ADD 'DC IC E10lNTS101C RED INIESIRIES N2330-30 N/A 73879 SBDG #11 30151MDG0lM 00TER EM!RGY 4 7195 N/A N/A SBDG #12 l

_3Q151MDGD234 OXPER ENERGY M)-71%

N/A N/A SBIU #13 3015 DOG 0334 CDTER ENERGY M)-7197 N/A N/A STARr AIR R #11 3Q151MrS0134 000FER ENERGY 8L2101 N/A 1036 START AIR R #12 3015DGS0234 00TER ENER3Y 812102 N/A 1037 START AIR R #13 3Q151MrS0334 COOPER ENE mY 80601 N/A 1040 START AIR TK #14

_3Q151 MISO 434 CDTER ENEKY S 0 602 N/A 1041 i

l l

l NI$1.CL3.1RE01

+

PAGE 6 cf 9 SUPPLEMENTAL FOR ASME CODE CLASS 3 PIPING AND COMPONENTS j

1.

Chmer Houstm Liahtira & Power Conpany Electric Tower, P. O. Best 1700. Houston, TX 77001 i

(Nate and Address of Owner)

]

2.

Plant South hxas Project Electric Generatire Station P. O. Box 289, Wadsworth, TK 77483

)

(Name and Address of Plant) l 3.

Plant W it 1

4.

Owner Certificate of Authorir.ation (if twquired)

N/A i

5.

Cermercial Service Date 08/25/88

6. National Board Neber for linit N/A Manufacturer Conpanent or Manufacturer or Installer State or National i

Appurtenance or Installer Serial No.

Province No.

Board No.

SIART AIR 'DC #15 3Q151MTS0534 CDT!!R PNDCY IH1201 N/A 1042 SIART AIR 'DC #16 30151M130634 (DTER ENDCY 8H1202 N/A 1043 SBID PGf #11 30151ME001%

DELAVAL 980021-1 N/A N/A SBID PWf #12 30151)fCD2%

DE1AVAL 980021-5 N/A N/A SBID PGe #13 3Q!511f003%

IE AVAL 980021-6 N/A N/A 1D HEATER #11 30151 M 134 E. L. WIFGAND 9C2303 N/A 1517 ID HEAD!R #12 3Qlfl W 234 E. L. WrEGAND 9C2302 N/A 1516 ID HEA'D!R #13 3Q151 6 334 E. L. WIlOAND 9C2304 N/A 1544 ID Puf #11 3Q151tfUOl34 DE1AVAL 9D2003

,N/A N/A 1D Puf #12 3Q151tfUO234 II!!AVAL 9D2002 N/A N/A 10 Puf #13 3Q1511EID334 II!1AVAL 8G1501 N/A N/A Jitt WIR CLR #11 30151 6 134 AMIRICAN STANDARD 910 301 N/A 33817 JICT WIR CIA #12 30151 M 234 Alf!RICAN STANDARD 9F0303 N/A 33816 JICT WIR CIR #13 3Q151 6 334 Alf!RICAN SIANDARD 9t0302 N/A 33818 ID CLR #11 3Q151M136 AM2RICAN STANDARD 960 306 N/A 33838 ID CLR #12 30151 M 236 AMERIC,W STANDARD 960304 N/A 33836 NISA.CL3. IRE 01

g PAGE 7 cf 9 SUPPLEMENTAL FOR ASME CODE CLASS 3 PIPING AND COMPONENTS i

1.

Omer Heustm Liahtira & Power Ccmpany Electric Tower, P. O. Base 1700, )buston, 'Dt 77001 (Nes and Address of Owner) 2.

Plant South hxas Project Electric Generatire Station P. O. Best 289. Wadsworth, 'DC 77483 (Nme and Addtwas of Plant) 3.

Plant Unit 1

4.

Chmer Certificate of Authorization (if required)

N/A Ccrmercial Service Date 08/25/88

6. Natimal Board Reiber for thit N/A Manufacturer Cenpanent or Manufacturer or Installer State or National L

Apsurtenance or Installer Serial No.

Province No.

Board No.

10 CIA #13 30151 2 336 AMFRICAN STANDARD 9tG305 N/A 33837 SB Jitt WIR M 3Q1511%B01% _

CRANE DEMDG NDC-001336 N/A N/A SB JICE WIR M 3Q151MAB02%

CRANE IEMDU NtC-001335 N/A N/A a xr m M 30151MAB03%

CRANE DEMDG NDC-001337 N/A N/A JICT WIR CIE M 3Q151tfXDl%

CRANE DEMDG BE1701 N/A N/A JICT WIR CIE M 3Q15DfXD2%

CRANE DEMDC 9A1301 N/A N/A Jict WIR CIIC M 3Q1511FXD3M CRANE DEMDG 9A1303 N/A N/A Jitt WIR CIE HIR

_30151 6 135 E. L. VI1EAND 900502 N/A 1514 M VIR CIIC HIR 3Q151 6 235 E. L. VI1GAND 9CD504 N/A 1519 JICT WIR CIRC HIR 3Q151 M 335 E. L. VI1GAND 9C0506 N/A 1515 CLASS 3 PIPING EBASI) (I)

N/A N/A N/A CIASS 3 VALVES VARIOUS N/A N/A N/A NISA.CL3.1RE01

[L l

PAGE 8 cf 9 SUPPLEMENTAL FOR ASME CODE CLASS 3 PIPING AND COMPONENTS j

1, Owner Houston Liahtira as Power Ccripany Electric 'huer, P. O. Box 1700. Houston, TX 77001 (Nme ard Mdress of Chmer) 2.

Plant South Texas Pro.foet Electric Generatira Station P. O. kat 280, Wadsworth, TK 771.8, 3

(Nane and Address of Plant) l 3.

Plant Unit 1

4.

Owner Certificate of Autkrir.ation (if required)

N/A 4

5.

Ccumercial Service Date 08/25/88

6. National Board N.inber for Unit N/A j
10. ABSTRACT OF EXAMINATION System Functional and Inservice Tests as prescribed by IWA-5211(b) and (c),

respectively, were conducted on selected ASME Code Class 3 Pressure Retaining Systems / Components in accordance with Table IWD-2500-1, l

Examination Category D-A, Item No. D1.10 and Examination Category D-B, Item No. D2.10.

The Pressure Tests and VT-2 visual examinations were conducted in accordance with IPSP15-CH-0001, Essential Chilled Water System Inservice Pressure Test (Rev. 1), IPSP15-DG-0001, Standby Diesel Generator System Tunctional Pressure Test (Rev. 3), and IPSP15-RM-0001, Reactor Makeup Water System Functional Pressure Test (Rev. 1).

ASME Code Class 3 piping and valves are specifically identified in the above referenced procedures. The above testa procedures were conducted during the time period of July 17, 1989 to November 1, 1989.

t 6

NISI.CL3.1RE01

4; i i

_g y-PAGE 9 cf 9

+

g SUPPLEMENTAL i

FOR-

%-?

ASME CODE CLASS 3 PIPING AND COMPONENTS

( %

a.

,1) 1.

Owner._ Houston Liahtira & Power Capany Electric 'Ibwer, P. O. Bax 1700, Houston, TX 77001 (Nee and Address of Owner) 2.

Plant South Texas Pro.f act Electric Generatira Station P. O. Box 280. Wadsworth, 'DC 77483 (N me and Address of Plant) 3.

Plant Unit __

1 4.- Owner Certificate of Auttorization (if aquired)

N/A 4

5.

Camercial Service Date 08/25/88

6. National Board Neber for Unit,

N/A

12. -

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical. joints such as valve stems and flanged connections.

These leaks were evaluated and determined acceptable for.

- continued systern operaticri. - Appropriate corrective action was initiated to correct.these leaks.

NIS1.CL3.1RE01 c