Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20217K94415 October 1999SER Accepting Util Alternative Proposed Relief Request RR-ENG-2-4 for Second 10-year ISI Interval at Stp,Units 1 & 2 Pursuant to 10CFR50.55a(a)(3)(i)Nondestructive Examination
ML20217K91515 October 1999SER Authorizing Util Relief Request RR-ENG-2-3 for Second 10-year ISI Interval of Stp,Units 1 & 2 Pursuant to 10CFR50.55a(a)(3)(i)Nondestructive Examination
Incorporated by reference
NOC-AE-000676, Monthly Operating Repts for Sept 1999 for South Texas Project,Units 1 & 2.With30 September 1999Monthly Operating Repts for Sept 1999 for South Texas Project,Units 1 & 2.With
ML20217D05330 September 1999Rev 1 to STP Electric Generating Station Unit 2 Cycle 7 Colr
ML20217D04830 September 1999Rev 1 to STP Electric Generating Station Unit 1 Cycle 9 Colr
ML20211P8419 September 1999Safety Evaluation Supporting Alternative Proposed by Licensee to Surface Exam to Perform Boroscopic VT-1 Visual Exam of Pump Casing Welds within Pump Pits for Welds Covered by Relief Request RR-ENG-24Incorporated by reference
ML20211P7819 September 1999SER Approving Second 10-year Interval Inservice Insp Program Plan Relief Request RR-ENG-2-8 (to Use Code Case N-491-2) for South Texas Project,Units 1 & 2Incorporated by reference
ML20211Q6739 September 1999Safety Evaluation Accepting First 10-yr Interval ISI Program Plan Request for Relief from ASME Code Case N-498Boric Acid
Hydrostatic
VT-2
Incorporated by reference
NOC-AE-000643, Monthly Operating Repts for Aug 1999 for South Texas Project,Units 1 & 2.With31 August 1999Monthly Operating Repts for Aug 1999 for South Texas Project,Units 1 & 2.With
ML20212E51931 August 1999Rev 3 to SG-99-04-005, STP 1RE08 Outage Condition Monitoring Rept & Final Operational Assessment
ML20211F45324 August 1999Safety Evaluation Supporting Licensee Proposed Alternative to Defer Partial First Period Exams of flange-to-shell Weld to Third Period & Perform Required Ultrasonic Exams,Both Manual & Automated,During Third PeriodNon-Destructive Examination
Incorporated by reference
ML20211F51123 August 1999Safety Evaluation Supporting Licensee Proposed Alternative Contained in Request for Relief RR-ENG-30Nondestructive Examination
VT-2
Incorporated by reference
ML20210C94131 July 1999Rev 1 to SG-99-07-002, South Tx,Unit 1 Cycle 9 Voltage- Based Repair Criteria 90-Day Rept, Jul 1999
ML20210R36331 July 1999Monthly Operating Repts for July 1999 for South Tx Project, Units 1 & 2.With
ML20210D91623 July 1999Safety Evaluation Accepting Inservice Testing Relief Request RR-56 Re Component Cooling Water & Safety Injection Sys Containment Isolation Check Valve Closure Test FrequencyEnforcement Discretion
Probabilistic Risk Assessment
Incorporated by reference
Foreign Material Exclusion
Large early release frequency
ML20210D48221 July 19991RE08 ISI Summary Rept for Steam Generator Tubing of South Texas Project Electric Generating Station Unit 1
ML20210D44921 July 1999Revised Chapters to Operations QA Plan, Including Rev 9 to Chapter 1.0, Organization & Rev 6 to Chapter 16.0, Independent Technical Review
NOC-AE-000583, LER 99-S03-00:on 990619,failure to Revitalize Sdg Number 11 Was Noted.Caused by Failure to Communicate Status of Sdg. Subject Sdg Revitalized on 990619 & Licensee Will Develop Security Force Instruction Re Sdgs.With15 July 1999LER 99-S03-00:on 990619,failure to Revitalize Sdg Number 11 Was Noted.Caused by Failure to Communicate Status of Sdg. Subject Sdg Revitalized on 990619 & Licensee Will Develop Security Force Instruction Re Sdgs.With
ML20207H6368 July 1999Safety Evaluation Approving 2nd 10 Yr Interval ISI Program Plan Request to Use ASME Section XI Code Case N-546 for Licenses NPF-76 & NPF-80,respectivelyNondestructive Examination
VT-2
Incorporated by reference
ML20216D7487 July 19991RE08 ISI Summary Rept for Welds & Component Supports of STP Electric Generating Station,Unit 1Nondestructive Examination
VT-2
Liquid penetrant
NOC-AE-000593, Monthly Operating Repts for June 1999 for Stp,Units 1 & 2. with30 June 1999Monthly Operating Repts for June 1999 for Stp,Units 1 & 2. with
NOC-AE-000570, LER 99-S01-00:on 990527,discovered That Unescorted Access Had Been Inappropriately Granted.Caused by Failure to Follow Procedure.Util Verified That Individual Did Not Have Current Unescorted Access at STP or Any Other Util.With28 June 1999LER 99-S01-00:on 990527,discovered That Unescorted Access Had Been Inappropriately Granted.Caused by Failure to Follow Procedure.Util Verified That Individual Did Not Have Current Unescorted Access at STP or Any Other Util.With
ML20196G58223 June 1999LER 99-S02-00:on 990601,failure to Maintain Positive Control of Vital Area Security Key Was Noted.Caused by Lack of Attention to Detail.Discussed Event with Operator Involved IAW Constructive Discipline ProgramStolen
ML20195J68717 June 1999Safety Evaluation Supporting Proposed Alternative Contained in RR-ENG-2-5.Proposed Alternative Authorized Per 10CFR50.55a(a)(3)(i) for 2nd ISI IntervalIncorporated by reference
ML20196A23915 June 1999Change QA-042 to Rev 13 of Operations QAP, Reflecting Current Organizational Alignment for South Texas Project & Culminating Organizational Realigment That Has Been Taking Place During Past Several MonthsNondestructive Examination
Fire Protection Program
NOC-AE-000563, Monthly Operating Repts for May 1999 for Stp,Units 1 & 2. with31 May 1999Monthly Operating Repts for May 1999 for Stp,Units 1 & 2. with
ML20206U54118 May 1999Non-proprietary Errata Pages for Rev 2,Addendum 1 to WCAP-13699, Laser Welded Sleeves for 3/4 Inch Diamete Tube Feedring Type & W Preheater SGs Generic Sleeving Rept
ML20206A77230 April 1999STP Electric Generating Station Unit 1 Cycle 9 Colr
NOC-AE-000543, Monthly Operating Repts for Apr 1999 for Stp,Units 1 & 2. with30 April 1999Monthly Operating Repts for Apr 1999 for Stp,Units 1 & 2. with
ML20205H03231 March 1999Change QA-040 to Rev 13 of Operations QA PlanNondestructive Examination
NOC-AE-000507, Monthly Operating Repts for Mar 1999 for Stp,Units 1 & 2. with31 March 1999Monthly Operating Repts for Mar 1999 for Stp,Units 1 & 2. with
ML20205A37822 March 1999STP Electric Generating Station Simulator Certification Four Yr Rept for Units 1 & 2
ML20204B27115 March 1999Safety Evaluation Authorizing 990201 Request to Authorize Alternative to Regulations Per 10CFR50.55a(a)(3)(i) That Would Revise Start of Second 120-month IST Interval to No Later than 011201Incorporated by reference
ML20207M92312 March 1999Amended Part 21 Rept Re Cooper-Bessemer Ksv EDG Power Piston Failure.Total of 198 or More Pistons Have Been Measured at Seven Different Sites.All Potentially Defective Pistons Have Been Removed from Svc Based on Encl Results
NOC-AE-000468, Monthly Operating Repts for Feb 1999 for South Texas Project Electric Generating Station.With28 February 1999Monthly Operating Repts for Feb 1999 for South Texas Project Electric Generating Station.With
ML20207D11024 February 1999Change QA-039 to Rev 13 of Operations QA Plan, for STP
ML20203H83617 February 1999Safety Evaluation Supporting Request for Relief from ASME Code Requirements for Class 3 Piping for PlantVT-2
ML20202H9623 February 1999SER Accepting Change to EALs Used in Classification of Emergency Conditions
ML20202E84731 January 19992RE06 ISI Summary Rept for SG Tubing of STP Electric Generating Station,Unit 2
ML20216G20131 January 1999City Public Svc of San Antonio Annual Rept 1998-1999
ML20199G59631 January 1999Cycle 7 Voltage-Based Repair Criteria Rept for Jan 1999Nondestructive Examination
B.5.b Mitigating Strategies
ML20199K77121 January 1999Safety Evaluation Accepting ISI Program Request for Relief for ASME Cose Repair Requirements for Code Class 3 PipingVT-2
ML20199G81619 January 1999SER Accepting Util 970707 Response to NRC 970509 RAI Re GL 92-08, Thermo-Lag 330-1 Fire Barriers. NRC Finds No Significant Safety Hazards Based on Application of Util Ampacity Derating MethodologySafe Shutdown
Fire Barrier
ML20199H49811 January 19992RE06 ISI Summary Rept for Welds & Component Supports of Stp,Unit 2Nondestructive Examination
VT-2
Liquid penetrant
ML20206Q3754 January 19992RE06 ISI Summary Rept for Sys Pressure Tests (Class 1 & 2)VT-2
ML20206Q3724 January 19992RE06 ISI Summary Rept for Repairs & Replacements
ML20216G21731 December 1998Houston Industries 1998 Annual Rept. App a 1998 Financial Statements & Us Securities & Exchange Commission Form 10-K Encl
NOC-AE-000403, Monthly Operating Repts for Dec 1998 for South Texas Project Unit 1 & 2.With31 December 1998Monthly Operating Repts for Dec 1998 for South Texas Project Unit 1 & 2.With
ML20216G15231 December 1998Central & South West Corp 1998 Summary Annual Rept & Securities & Exchange Commission Form 10-K
ML20198M34328 December 1998SER Accepting Util Request for Relief from ASME Code Repair Requirements for ASME Code Class 3 Piping for South Texas Project,Unit 2