. . . . . .. .- . - _ _ .. - .--

l.

COVER SHEET 1RE06 INSERVICE INSPECTION

SUMMARY

REPORT FOR SYSTEM PRESSURE TESTS >

( CLASS 1 AND 2 )  ;

j SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 1

! P. O. BOX 289

WADSWORTH, TEXAS 77483 USNRC DOCKET NO
50-498 OPERATING LICENSE NO: NPF-76 COMMERCIAL OPERATION DATE: AUGUST 25, 1988 b f~

/

B. J. 5H!of't,' Consulting Engineer y: .

'W. R. Harris. ' Supervising Engineer y; [d/ f M 5.'Tashley,' i - Reliability Engineering Division J

v609090318 960829 8 DR ADOCK 0500

i i- -

SCOPE 1

5 1RE06 SYSTEM PRESSURE TESTS 1

! The examinations summarized in this report were performed in j accordance with the 1983. Edition through Summer 1983 Addenda of j the ASME Code,.Section XI which is applicable to the South Texas

Project Electric Generating ~ Station, Unit 1. This report covers I

selected ASME Code Class 1 and 2 Systems / Components. Examinations and tests required by the Code are scheduled in accordance with

" Inspection Program B" as defined in IWB-2412 and'IWC-2412 for ASME Code Class 1 and 2 Systems / Components. All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P which established the examination frequency at each refueling outage. The ASME Code Class 2 Systems / Components were selected'on a' prorated basis. This prorated selection process will continue until all ASME Code Class 2-Systems / Components are examined in accordance with Table-2500-1, Examination Category C-H. This examination category for ASME Code Class 2-Systems / Components established the examination frequency at each. inspection period. The remaining third period examinations are anticipated to be completed by the end (9-24-99) of the third inspection period.

The System Leakage Test [IWA-5211(a)] conducted on Class 1 Systems / Components in accordance with Examination Category B-P also satisfied the pressure tests required by IWA-5214(e) subsequent to the disassembly and reassembly of mechanical jointe in ASME Code Class 1 Systems / Components. j l

I l

i

-. ,_ . . - - , - . . . -. - - - . . . . - , , . . - ,. .n

T Page I of 3 FORM NIS-1 OWNERPS REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules l

6 1.' Owner Houston Lichtinc & Power Company Electric Tower. P. O. Box 1700. Houston . TX 77001

2. Plant South Texas Project Electric Genciptine Station P.O. Box 289. Wadsworth. TX 77483 .
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A I
5. Commercial Service Date 08/25/88 6. National Board Number for Unit N/A  !

.i

7. . Components inspected ASME CODE CLASS 1 PIPING AND COMPONENTS Component or Manufacturer Manufacturer or State or National Appurtenance or Installer Installer Serial Province Board No.

i No. No.

! REACTOR VESSEL COMBUSTION ENGR / 11073 N/A 22190 IR10lNRV101 A WESTINGHOUSE (M)

STM. GENERATOR 1A WESTINGHOUSE (M) 2131 N/A W18691 1R121NSG10!A STM.GENERATORIB. WESTINGHOUSE (M) 2132 N/A W18692 1R 121NSG101B STM.GENERATORIC WESTINGHOUSE (M) 2133 N/A W18693 I R121NSG101C

l. STM. GENERATOR 1D WESTINGHOUSE (M) 2134 N/A Wl8694 l 1R121NSG101D PRESSURIZER 1 A WESTINGHOUSE (M) 2141 N/A W18590 IR!!1NPZ101 A ,

RC PUMP I A WESTINGHOUSE (M) 1-il5E580G01 N/A 28 1R131NPP101 A RC PUMP IB WESTINGHOUSE (M) 2-Il5E580G01 N/A 29 1R131NPP101B RC PUMP IC WESTINGHOUSE (M) 3-ll5E580G01 N/A 30 1R131NPP101C RC PUMP 1D WESTINGHOUSE (M) 4-115E580G01 N/A 31 1R131NPP101D CLASS 1 PIPING EBASCO (I) N/A N/A CLASS 1 VALVES VARIOUS N/A N/A N/A 1

l l

4 i

4 1

! Note: Supplemental rhects in the form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 11 in.,(2) l information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the l number of sheets is recorded at the top of this form.

4

}

4 A- , . , . . ,, .,. -.

. . 1 Page 20f 3 i

i FORM NIS-1 (Hack) fl. Examination Dates 06/22/95 to 07/24/96 9. Inspection Interval from 08/25/88 to 09/24/99 1

l

10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for ,

i current interval. Refer to Supplemen'. I P' eet Page 3 of 3.

I 1. Abstract of conditions Noted No relevant conditions affecting pressure retaining boundaries were noted. )

12. Abstract of Corrective Measures Recommended and Taken j 4

Refer to Supplemental Sheet Page 3 of 3. 1 I We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to i the rules of the ASME Code,Section XI. i Certificate of Authorization No. (if applicable) N/A Expiration Dat N/A j Date M 20 19 95 Signed Houston Lichtinc & Power Co. By Owner [ TJ Jordan ystems Engineering Manager 4

i ..

i CERTIFICATE OF INSERVICE INSPECTION i

$ I 1, the undersigned, holding a valid commission issued by the Natic tal Board of Boiler and Pressure Vessel Inspectors i and the State or Province of Texas and employed by Arkwricht Ii tual Insurance Co. of N_orwood. MASS. have inspected the components described in this Owner's Report during ~he period 6-22-6/JiiP214-47Go 3 and state that to the best of my knowledge and belief, the Owner hr. performed examinationsand taken corrective

measures described in this Owner's report in accordance with the ir,spection plan and as required by the ASME Code,Section XI. '

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning j I

i- the examinations and corrective measures described in this Owner's Report. Furthermoie, neither the Inspector nor his j employer shall be liable in any manner for any personal injury or porperty damage or a loss of any kind arising from or i connected with this inspection. i f I t m # Commissions TX-821._

B. R. Russell, inspector's Signature National Board, State, Province, and Endorsements Date _ j~~J*d - ___ _19fd ._

l l

1

. Page3 of 3 SUPPLEMENTAL PAGE FOR ASME CODE CLASS 1 PIPING AND COMPONENTS

1. Owner Houston Lichtinc & Power Company Electric Tower. P. O. Box 1700. Houston . TX 77001
2. Plant Equi.).T,s_xas l Poriect Electric Generatine Station P.O. Box 289. Wadsworth. TX 77483
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 08/25/88 6. National Board Number for Unit N/A
10. ABSTRACT OF EXAMINATIONS i

A System Leakage Test as prescribed in IWA-5211(a) for all ASME Code Class 1 Pressure Retaining Conponents was conducted in accordance with Table IWB-2500-1, Examination Category B-P, Item Nos. B15.10, B15.20, B 15.30, l B 15.40, B 15.50, B 15.60, and B 15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with Plant Surveillance Pressure Test Procedure, OPSP15.RC-000), Reactor Coolant System Leakage Pressure Test (Rev. 3) at the conclusion of the sixth l

refueling outage. ASME Code Class 1 piping and valves are specifically identified in the above reference procedure. j Also. System Pressure Tests subsequent to all of the disassembly and reassembly of mechanicaljoints in ASME Code Class I components as prescribed by IWA-5214(e) were conducted in accordance with OPGP03-ZE-0027, ASME Section XI Repair, Replacement and Post-Maintenance Pressure Testing (Rev. 9) for individual work items performed during the sixth refueling outage as a result of the performance of the System Leakage Pressure Test described above.

12. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during the Pressure Test found minor leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued operation.

Appropriate corrective action was initiated to correct these leaks.

l l

1 i

l

Page I of 3 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS

, As required by the Provisions of the ASME Code Rules

1. Owner Houston Lichtinc & Power Comnany Electric Tower. P. O. Box 1700. Houston . TX 77001
2. Plant South Texas Proiect Electric Generatine Station P.O. Box 289. Wadsworth. TX 77483
3. Plant Unit i 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 08/25/88 6. National Board Number for Unit N/A
7. - Components Inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Component or Manufacturer Manufacturer or State or National Appurtenance or Installer Installer Serial Province Board No.

No. No.

RWST I A BROWN I100-15 N/A N/A 2N121NTF101 A MINNEAPOLIS (M)

HHSI PUMP I A PACIFIC PUMPS (M) 51695 N/A 382 2N121NPA101 A HHSI PUMP IB PACIFIC PUMPS (M) 51696 N/A 383 2N121NPA101B HHSI PUMP lc PACIFIC PUMPS (M) 51700 N/A 402 2N121NPA101C LHS1 PUMP 1 A PACIFIC PUMPS (M) 51701 N/A 420 2N121NPA102A LHS1 PUMP IB PACIFIC PUMPS (M) 51702 N/A 421 2N121NPA102B LHS1 PUMP IC PACIFIC PUMPS (M) 51703 N/A 422 2N121NPA102C CS PUMP I A PACIFIC PUMPS (M) 51707 N/A 441 2N10lNPA101 A CS PUMP 1B PACIFIC PUMPS (M) 51708 N/A 441 2N10lNPA101B CS PUMP IC PACIFIC PUMPS (M) 51709 N/A 442

_2N101NPA101C SI ACCUM TANK I A SOUTHWEST FAB (M) 0043 N/A 362 2N121NRC101 A SI ACCUM TANK IB SOUTHWEST FAB (M) 0044 N/A 363 i 2N121NRC101B SI ACCUM TANK IC SOUTHWEST FAB (M) 0045 N/A 364 2N121NRC101C ASSOCIATED CLASS 2 EBASCO (1) N/A N/A PIPING ASSOCIATED CLASS 2 VARIOUS N/A N/A N/A VALVES Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. X 1 I in.,(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

, Page 3 of 3

, FORM NIS-I (Hack)

8. Examination Dates 06/22/95 to 07/24/96 9. Inspection Interval from 08/25/88 to 09/24/99 1
10. Abstract of Examinations Include a list of examinations and a statement concerning status of work required for I current interval. Refer to Supplemental Sheet Page 3 of 3.

l 1

11. Abstract of conditions Noted '

I No relevant conditions affecting pressure retaining boundaries were noted,

12. Abstract of Corrective Measures Recommended and Taken  !

Refer to Supplemental Sheet Page 3 of 3. l l

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to l the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) N/A Expiratio ate N/A Date 9 !80 19 N Signed _ Houston Lichtinc & Power Co. By _

/ Owner

/ TJ Jordan Systems Engineering Manager CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Texas and employed by Arkwricht Mutual Insurance Co. of Norwood. M ASS. have inspected the components described in this Owner's Report during the period 6-22-96' to M #-@ ,

and state that to the best of my knowledge and belief, the Owner has performed examinationsand taken corrective measures described in this Owner's report in accordance with the inspection plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, nei'her the Inspector nor his employer shall be liable in any manner for any personal injury or porperty damage or a loss of any kind arising from or connected with this inspection.

_ Commissions TX-826 B. R. Russell, Inspector's Signature National Board, State Province, and Endorsements i

Date__ _ _ _ _ N_~ _19_h__

1 ww

~ ,.

. Page 3 of 3

~ ' SUPPLEMENTAL PAGE FOR ASME CODE CLASS 2 PIPING AND COMPONENTS

1. Owner Un91!np Lichtinc & Power Company Electric Tower. P. O. Box 1700. Houston . TX 77001
2. Plant South Texas Poriect Electric Generatine Station P.O. Box 289. Wadsworth. TX 77483
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 08/25/88 6. National Board Number for Unit N/A
10. ABSTRACT OF EXAbilNATIONS System Functional and inservice Pressure Tests as prescribed by IWA-5211(b) and (c), respectively, were conducted on selected A SME Code Class 2 pressure retaining components in accordance with Table IWC-2500-1, Examination Category C-H, Item Nos. C7.10, C7.30, C7.50, and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted during the third period of examination in accordance with the following Plant Surveillance Pressure Test Procedures:

OPSP15-CS-0001 Containment Spray System Functional Pressure Test (Rev. 2)

OPSP15-FW-0001 Feedwater System Inservice Pressure Test (Rev.1)

OPSP15-RC-0001 Reactor Coolant System Leakage Pressure Test (Rev. 3)

OPSP15-SI 0001 Safety Injection System Functional Pressure Test (Rev. 0)

ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures. These tests were conducted during the time period of May 17,1996 to July 24,1996.

12. ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKf;E The Visual Examinations (VT-2) performed during the Pressure Test found minor leakage at mechanicaljoints such as valve stems and flanged connections. These leaks were evaluated and determined accepable for continued operation.

Appropriate corrective action was initiated to correct these leaks.

l l

j

__ . _ . _ _ _ . -- . - .