ML20086G945

From kanterella
Jump to navigation Jump to search
1RE05 ISI Summary Rept for Sys Pressure Tests (Class 1 & 2)
ML20086G945
Person / Time
Site: South Texas 
Issue date: 06/29/1995
From: Pathak A, Thomas S, Timmaraju S
HOUSTON LIGHTING & POWER CO.
To:
Shared Package
ML20086G944 List:
References
NUDOCS 9507170317
Download: ML20086G945 (14)


Text

. _ _

COVER SHEET 1RE05 INSERVICE INSPECTION

SUMMARY

REPORT FOR SYSTEM PRESSURE TESTS

( CLASS 1 AND 2 )

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 1 P.O. BOX 289 WADSWORTH, TEXAS 77483 i

USNRC DOCKET NO: 50-498 OPERATING UCENSE NO: NPF-76 COMMERCIAL OPERATION DATE: AUGUST 25, 1988 O /I-$d g - 2(- 65~

I Prepared by:

K. PTathak, Consulting Engineer Reviewed by:

6 6[ 4 /91' 4

i S. Tunmaraiu, Sr. Consulting Er6. ;;

j 0MD Approved by:

S. E. Thomas, Manager - Design Er@.;;;ing Department i

i' 4

V e

i 4

n 9507170317 950711 i

PDR ADOCK 05000498 j

Q PDR

~

SCOPE 1RE05 SYSTEM PRESSURE TESTS The examinations summarized in this report were performed in accordance with the 1983 Edition through Summer 1983 Addenda of the ASME Code,Section XI which is applicable to the South Texas Project Electric Generating Station, Unit 1. This report covers selected ASME Code Class 1 and 2 Systems / Components. Examinations and tests required by the Code are scheduled in accordance with

" Inspection Program B" as defined in IWB-2412 and IWC-2412 for ASME Code Class 1 and 2 Systems / Components. All ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1, Examination Category B-P which established the examination frequency at each refueling outage. The ASME Code Class 2 Systems / Components were selected on a prorated basis. This prorated selection process will continue until all ASME Code Class 2 Systems / Components are examined in accordance with Table-2500-1, Examination Category C-H.

This examination category for ASME Code Class 2 Systems / Components established the examination frequency at each inspection period. The remaining second period examinations are anticipated to be completed by the end (9-25-96) of the second inspection period.

l The System Leakage Test [IWA-5211(a)] conducted on Class 1 Systems / Components in accordance with Examination Category B-P also satisfied the pressure tests required by IWA-5214 (e) subsequent to the disassembly and reassembly of mechanical joints in ASME Code Class 1 Systems / Components.

i

i j

FORM NIS 1 OWNER'S REPORT FOR INSERVICE INSPECTIONS Page 1 of 3 As required by the Provisions of the ASME Code Rules 1.

Owner Houston Liahtina & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Proiect Electric Generatina Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A i

5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 1 PlPING AND COMPONENTS l

Manufacturer State or Component or Manuiacturer or installer National r

ce Appurtenance or installer Serial No.

Board No.

+

REACTOR VESSEL COMBUSTION ENGINEERING /

11073 N/A 22190 1R101NRV101A WESTINGHOUSE (M)

G"

^

A WESTINGHOUSE (M) 2131 N/A W18691 NSG101A i

^

WESTINGHOUSE (M) 2132 N/A W18692 1NSG101B

^

21NSG101C

" "^

WESTINGHOUSE (M) 2134 N/A W18694 21NSG1O D

" A WESTINGHOUSE (M) 2141 N/A W18590 R

N 01 ESTWGHOUSE (M) 1-115E580G01 N/A 28 R13 PP101A I

^

R13 PP1018 H

(

11 580G01 N/A 30 j

R13 PP101C S

H S

4-115E580G01 N/A 31 R13 PP101D EBASCO (1)

N/A N/A N/A NG VARIOUS N/A N/A N/A g

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

..,.----:--s-,.-

.e

-,----.w----,--

.,.---~-4--,..,-----+--'.-m.-

- - +,. ~. - - - - - - -

FORM NIS-1 (Back)

Page 2 of 3

8.. Exar ination Dates 01/01/93 to 04/25/95
9. Inspection Interval from 08/25/88 to 08/25/98

. 10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. Refer to Supplemental Sheet Page 3 of 3.

11. Abstract of Conditions Noted No relevant conditions affecting pressure retaining boundaries were noted.

~

- 12. Abstract of Corrective Measures Recommended and Taken Refer to Supplemental Sheet Page 3 of 3.

j We certify that the statements made in this report are correct and the dxaminations an corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date

'N/A l

b Date M&A /f.

19.j_1 Signed Houston Lichtina & Power Co.

By (T

Owner

[lD. Halpin.

Systems Engineering Manager i

CERTIFICATE OF INSERVICE INSPECTION

{

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Texas and employed by ' Arkwricht Mutual Insurance A of Norwood. MASS.

have inspected the components described in this Owner's Report during the period 3-6,-OK to_ 6 - M -4 f

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the inspection plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or.

i implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

j FACTORY MUTUAL SYSTEM 4

- > e du Commissions TX-826 B.R. Russell, inspector's Signature National Board, State, Province, and Endorsements Date 6 19 I i

l

,t

".e4549%

_. ~.,. _

m..,._m

~_.._,,,,.....-.--.....~,._m,,,..,~...,_._..,,,-,,___.,_.c

.,,....,,,,,.,-.._.y,-

~~

SUPPLEMENTAL FOR Page 3 of 3 ASME CODE CLASS 1 PIPING AND COMPONENTS -

l 1.

Owner Houston Uchtino & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Project Electric Generatino Station P.O. Box 289. Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 10.

ABSTRACT OF EXAMINATIONS A System Leakage Test as prescribed by IWA 5211 (a) for all ASME Code Class 1 Pressure Retaining Components was conducted in accordance with Table IWB-l 2500-1, Examination Category B-P, item Nos. B15.10, B15.20, B15.30, B15.40, l

B15.50, B15.60 and B15.70.

The Pressure Test and VT-2 visual examinations were conducted in accordance with Plant Surveillance Pressure Test Procedure, OPSP15-RC-0001, Reactor Coolant System Leakage Pressure Test (Rev. 2) at the conclusion of the fifth refueling outage. ASME Code Class 1 piping and valves are specifically identified l

t in the above referenced procedure.

Also, System Pressure Tests subsequent to all of the disassembly and reassembly

['

of mechanical joints in ASME Code Class 1 components as prescribed by IWA-5214 (e) were conducted in accordance with OPGP03-XE-0027, ASME Section XI Repair, Replacement and Post-Maintenance Pressure Testing (Rev. 8) for individual work items performed during the fifth refueling outage as a result of the performance of the System Leakage Pressure Test described above.

l i

l 12.

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN The Visual Examinations (VT-2) performed during the Pressure Test found minor i

leakage at mechanical joints such as valve stems and flanged connections. These leaks were evaluated and determined acceptable for continued system operation.

Appropriate corrective action was initiated to correct these leaks.

I f

i I

,--ev-~m.--mem

+.. - -,-_m,,

m,

l Page 1 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules i

1.

Owner Houston Liahtina & Power Comoany Electric Tower, P.O. Box 1700 Houston, TX 77001 (Name and Address of Oviner) 2.

Plant South Texas Project Electric Generatina Station P.O. Box 289. Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PlPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No.

Board No.

RCFC COIL 11 A AMERICAN AIR FILTER 906796-A1 N/A 805 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-A2 N/A 806 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-A3 N/A 807 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-A4 N/A 808 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-A5 N/A 809 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-B1 N/A 835 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-B2 N/A 836 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-83 N/A 837 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-84 N/A 838 2V141VHX001 RCFC COIL 11 A AMERICAN AIR FILTER 906796-85 N/A 839 2V141VHX001 RCFC COIL 12A AMERICAN AIR FILTER 906796-A6 N/A 810 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-A7 N/A 811 2V141VHX002 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number cf sheets is recorded at the top of this *orm.

Ireolct2

.,~

Page 2 of 9' FORM NIS 1 (Back)

8. ~ Examination Dates 01/01/93 'to 04/25/95
9. Inspection Interval from 08/25/88 to 08/25/98
10. Abstract of Examinations. ' Include a list of examinations and a statement concerning status of work required for current interval. Refer to Supplemental Sheet Page 9 of 9.

11.' Abstract of Conditions Noted No relevant conditions affecting pressure retaining boundaries were noted.

12. Abstract of Corrective Measures Recommended and Taken Refer to Supplemental Sheet Page 9 of 9.

We certify that the statements made in this report are correct and the examinations an corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date M&1 /6,19 98 Signed Houston Lichtino & Power Co.

By O

Owner lYD. Halpin SystemEngineeringManager CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesselinspectors and the State or Province of Texas and employed by Arkwricht MutualInsurance

,QA. of Norwood. MASS.

have inspected the components described in this Owner's Report t

during the period 6-M.,

  1. 6 to S-##-6(, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the inspection plan and as required by the ASME Code,Section XI.

?

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or i

implied, concerning the examinations and corrective measures described in this Owner's Report.

i Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACTORY MUTUAL SYSTEM Commissions TX-826 j

B.R. Russell, inspector's Signature National Board, State, Province, and Endorsements l

Date 6-ZZ - 19 T i

j l

.+

i W

1 i

k 8

IftCICf 2

Page 3 of 9 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS

^

1.

Owner Houston Liahtina & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Project Electric Generatina Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No.

Board No.

RCFC COIL 12A AMERICAN AIR FILTER 906796-A8 N/A 812 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-A9 N/A 813 l

2V!41VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-A10 N/A 814 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-B6 N/A 840 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-87 N/A 841 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-B8 N/A 842 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-89 N/A 843 2V141VHX002 RCFC COIL 12A AMERICAN AIR FILTER 906796-810 N/A 844 2V141VHX002 RCFC COIL 118 AMERICAN AIR FILTER 906796-A11 N/A 815 2V141VHX003 RCFC Colt 118 AMERICAN AIR FILTER 906796-A12 N/A 816 2V141VHX003 RCFC COIL 11B AMERICAN AIR FILTER 906796-A13 N/A 817 2V141VHX003 RCFC COIL 11B AMERICAN AIR FILTER 906796-A14 N/A 818 2V141VHX003 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/Tiii.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Irec$ ct2 4

Page 4 of 9 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS l

1.

Owner Houston Liahtino & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Project Electric Generatino Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No.

Board No.

RCFC COIL 11B AMERICAN AIR FILTER 906796-A15 N/A 819 2V141VHX003 RCFC COLL 11B AMERICAN AIR FILTER 906796-B11 N/A 845 2V141VHX003 RCFC COLL 11B AMERICAN AIR FILTER 906796-B12 N/A 846 2V141VHX003 RCFC COIL 118 AMERICAN AIR FILTER 906796-813 N/A 847 2V141VHX003 RCFC Colt 11B AMERICAN AIR FILTER 906796-B14 N/A 848 2V141VHX003 RCFC CO!L 118 AMERICAN AIR FILTER 906796-815 N/A 849 2V141VHX003 RCFC COIL 12B AMERICAN AIR FILTER 906796-A16 N/A 820 2V141VHX004 RCFC COIL 128 AMERICAN AIR FILTER 906796-A17 N/A 821 2V141VHX004 RCFC COIL 12B AMERICAN AIR FILTER 906796-A18 N/A 822 2V141VHX004 RCFC COIL 12B AMERICAN AIR FILTER 906796-A19 N/A 823 2V141VHX004 RCFC COIL 128 AMERICAN AIR FILTER 906796-A20 N/A 824 2V141VHX004 RCFC COIL 12B AMERICAN AIR FILTER 906796-B16 N/A 850 2V141VHX004 Note: lupplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i, sm

Page 5 of 9 SUPPLEMENTAL FOR i

ASME CODE CLASS 2 PIPING AND COMPONENTS 1.

Owner Houston Liahtina & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Proiect Electric Generatino Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No.

Board No.

RCFC COIL 128 AMERICAN AIR FILTER 906796-B17 N/A 851 2V141VHX004 RCFC COIL 128 AMERICAN AIR FILTER 906796-B18 N/A 852 2V141VHX004 RCFC COIL 12B AMERICAN AIR FILTER 906796-B19 N/A 853 2V141VHX004 RCFC COIL 12B AMERICAN AIR FILTER 906796-B' 0 N/A 854 2

y 2V141VHX004 RCFC COIL 11C AMERICAN AIR FILTER 906796-A21 N/A 825 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-A22 N/A 826 2V141VHX005 RCFC COLL 11C AMERICAN AIR FILTER 906796-A23 N/A 827 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-A24 N/A 828 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-A25 N/A 829 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-821 N/A 855 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-822 N/A 856 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-823 N/A 857 2V141VHX005 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

trec5ct2

Page 6 of 9 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS 1.

Owner Houston Lichtina & Power Comoany Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Project Electric Generatina Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A i

I 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No.

Board No.

RCFC COIL 11C AMERICAN AIR FILTER 906796-824 N/A 858 2V141VHX005 RCFC COIL 11C AMERICAN AIR FILTER 906796-825 N/A 859 2V141VHX005 RCFC COIL 12C AMERICAN AIR FILTER 906796-A26 N/A 830 2V141VHX006

)

RCFC COIL 12C AMERICAN AIR FILTER 906796-A'27 N/A 831 2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906796-A28 N/A 832 2V141VHX006 RCFC CO!L 12C AMERICAN AIR FILTER 906796 A29 N/A 833 2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906796 A30 N/A 834 2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906736-826 N/A 860 2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906796-B27 N/A 861 2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906796 828 N/A 862 j

2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906796-B29 N/A 863 2V141VHX006 RCFC COIL 12C AMERICAN AIR FILTER 906796-830 N/A 864 2V141VHX006 i

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

tensco i

Page 7 of 9 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS 1.

Owner Houston Liahtina & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Project Electric Generatina Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

REGEN HX 1 A JOSEPH OAT CORP 2380-1 A N/A 2051 2R171NHX101A LETDN REHEAT HX 1 A JOSEPH OAT CORP 2312 2A N/A 984 SR191NHX103A LETDN HX 1 A JOSEPH OAT CORP 2312-1 A N/A 986 5R171NHX102A R. C. FILTER 1 A PALL TRINITY 35280 N/A 18966 2R171NFR101A R. C. FILTER 1B PALL TRINITY 35281 N/A 18967 2R171NFR101B EXCESS LETDN HX 1 A JOSEPH OAT CORP 3212-3A N/A 988 SR171NHX103A RHR HX 1 A JOSEPH OAT CORP J-2312-4 A N/A 990 2R161NHX101 A RHR HX 1B JOSEPH OAT CORP J 2312-4B N/A 991 2R161NHX101B I

RHR HX 1C JOSEPH OAT CORP J-2312-4C N/A 992 l

2R161NHX101C RHR PUMP 1 A PACIFIC PUMP 51731 N/A 343 1

2R161NPA101A RHR PUMP 1B PACIFIC PUMP 51732 N/A 344 2R161NPA101B Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I 1

leeolci2 m

Page 8 of 9 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS i

.i 1.

Owner Houston Lichtino & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Proiect Electric Generatino Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 7.

Components inspected ASME CODE CLASS 2 PIPING AND COMPONENTS Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.

Province No.

Board No.

RHR PUMP 1C PACIFIC PUMP 51733 N/A 345 2R161NPA101C j

ASSOC. CLASS 2 EBASCO (1)

N/A N/A N/A PIPlNG ASSOC. CLASS 2 VARIOUS N/A N/A N/A VALVES 4

I i

Note: Supplemental sheets in form of hsts, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

1,eos sut

.,s

Page 9 of 9 SUPPLEMENTAL FOR ASME CODE CLASS 2 PIPING AND COMPONENTS 1.

Owner Houston Liahtino & Power Company Electric Tower, P.O. Box 1700, Houston, TX 77001 (Name and Address of Owner) 2.

Plant South Texas Project Electric Generatino Station P.O. Box 289, Wadsworth, TX 77483 (Name and Address of Owner) 3.

Plant Unit 1

4. Owner Certificate of Authorization (if required)

N/A 5.

Commercial Service Date 08/25/88

6. National Board Number for Unit N/A 10.

ABSTRACT OF EXAMINATIONS System Functional and Inservice Pressure Tests as prescribed by IWA-5211 (b) and (c), respectively, were conducted on selected ASME Code Class 2 pressure retaining components in accordance with Table IWC-2500-1, Examination Category C-H, item Nos. C7.10, C7.30, C7.50 and C7.70.

The Pressure Tests and VT-2 visual examinations were conducted during the second period of examination in accordance with the following Plant Surveillance Pressure Test Procedures:

OPSP15-CC-0001 -

Component Cooling Water System Inservice Pressure Test, (Rev.1)

OPSP15-CM-0001 -

RCB H Monitioring Functional Pressure Test, (Rev. 5) 2 1 PSP 15-CV-0001 -

Chemical and Volume Control System inservice Pressure Test, (Rev. 2) Inside Containment Portion Only 1 PSP 15-MS-0001 -

Main Steam System inservice Pressure Test (Rev. 5)

OPSP15-RC-0001 -

Reactor Coolant System Leakage Pressure Test (Rev. 2)

OPSP15-RH-0001 -

Residual Heat Removal System Inservice Pressure Test (Rev.1)

ASME Code Class 2 piping and valves are specifically identified in the above referenced procedures. These test procedure were conducted during the time period of January 1,1993 to April 25,1995.

12.

ABSTRACT OF CORRECTIVE MEASURES RECOMMENDED AND TAKEN w

The Visual Examinations (VT-2) performed during these Pressure Tests found only minor leakage at mechanical joints such as valve stems and flanged connections.

These leaks were evaluated and determined acceptable for continued system operation. Appropriate corrective action was initiated to correct these leaks.

ireo5ct2

. - - -