1RE06 ISI Summary Rept for Repairs & Replacements STP Generating Station,Unit 1
ML20117H559
Person / Time
Site: South Texas 
Issue date: 08/20/1996
From: Harris W, Lashley M, Pathak A
HOUSTON LIGHTING & POWER CO.
To:
Shared Package
ML20117H558 List:
References
NUDOCS 9609090326
Download: ML20117H559 (7)


Text

1' l

COVER SHEET 1RE06 INSERVICE INSPECTION

SUMMARY

REPORT l

l FOR REPAlRS AND REPLACEMENTS l

SOUTH ' TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 1 P.O. BOX 289 i

WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-498 OPERATING LICENSE NO: NPF-76 COMMERCIAL OPERATION DATE: AUGUST 25, 1988 o / b 'd.

E- /fM Prepared by:

A'. P.Pathak, Consulting Engineer

~

Reviewed by: I g/N

  1. -M-3 6 W. R!Har'ris, Supervising Engineer I 2O Approved by:

/M. SYLashle Manager - Reliabilty Engineering Division 4

l 9609090326 960829 PDR ADOCK 05000498 G

PDR

>JUTH TEXAS PROJECT UNIT - 1 ASME CODE SECTION - XI 1RE06 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 & 2)

R OR R SR PROJ. ID OF MFG..SN AND NB ITEM / COMP R OR R COMP.

NO.

NO.

ITEM (TPNS NO.)

(IF ANY) OF COMP.

DESCRIPTION DESCRIPTION ANil DATE 1-93-096 RH-170709 N/A PACIFIC PUMPS PUMP SEAL INSTALLED Hell-COIL IN A B.R. RUSSELL 6/27/96 MARK NO.

HOUSING SPARE SEAL HOUSING FOR TX-826 348918-1-AA RHR PUMPS 1-94-054 CV-315342 1R171TCV0037C BORG WARNER VALVE REMOVED AND REPLACED B. R. RUSSELL 7/25/96 SN: 29575 PODY TO BONNET SEAL WELD TX-826 1-94455 CV-176300 1R171TCVOO36C BW/IP VALVE REPLACED VALVE B.R. RUSSELL 7/25/96 SN: 95SD0201 TX-826 1 94-119 HC-203310 N/A N/A PIPING SPOOL INSTALLED A TEMPORARY B.R. RUSSELL 6/27/96 BLIND FLANGE AT SPOOL TX-826 HC-1003 1-95-050 51-323709 2N121TSIO1208 ANDERSON-VALVE REPLACED DISC AND BODY B.R. RUSSELL 6/27/96 GREENWOOD TO BONNET SEAL WELD TX-826 SN: A3828 1-95-052 WL-316734 B1WLFV4913 WKM VALVE REPLACED PLUG B.R. RUSSELL 6/27/96 SN: 70-119184 TX-826 NB: 1877 1-95-059 RH-319445 2R161TRH0169 EDWARD VALVES VALVES REPLACED VALVES B.R. RUSSELL 7/1/96 2R161TRHO170 SN: 50AHM TX-826 SN: 51 AHM 1-95-070 RC-32OO68 AIRCPCV0655A GARRETT RELIEF VALVE REPLACED PLUG AND B. R. RUSSELL 7/25/96 SN: P-138 SOLENOID VALVE TX-826 Page 1

SOUTH TEXAS PROJECT UNIT - 1 ASME CODE SECTION - XI 1RE06 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 & 2)

R OR R SR PROJ. ID OF MFG..SN AND NB ITEM / COMP R OR R COMP.

NO.

NO.

ITEM (TPNS NO.)

(IF ANY) OF COMP.

DESCRIPTION DESCRIPTION ANil DATE 1-95-101 SG-324063 1R121NSG101C WESTINGHOUSE STEAM DRILLED AND TAPPED B.R. RUSSELL 7/25/96 SN: 2133 GENERATOR SECONDARY MANWAY TX-826 NB: W18693 COVER 1-95-102 RC-329385 N1RCPSV3450 CROSBY SsFETY VALVE REPLACED SAFETY VALVE B.R. RUSSELL 7/25/96 SN: N60491-OO-OOO7 TX-826 NB: 1124 1-95-103 RC-329386 N1RCPSV3451 CROSBY SAFETY VALVE REPLACED SAFETY VALVE B.R. RUSSELL 7/29/96 SN: N60491-OO-OOO8 TX-826 NB: 1125 1-95-104 RC-329387 N1RCPSV3452 CROSBY SAFETY VALVE REPLACED SAFETY VALVE B.R. RUSSELL 7/29/96 SN: N60491-OO-OOO9 TX-826 NB: 1126 1-95-110 FW-333183 AIFWFV7141 WKM VALVE SEAL WELDED PACKING B.R. RUSSELL 7/25/96 SN: 536738 LEAK OFF PLUG TX-826 NB: 1994 1-95-111 FW-333184 A1 FWFV7142 WKM VALVE SEAL WELDED PACKING B.R. RUSSELL 7/25/96 SN: 536739 LEAK OFF PLUG TX-826 NB: 1995 1-96-002 MS-324362 2S101TMSO543 EDWARD VALVES VALVE REPLACED VALVE B.R. RUSSELL 7/25/96 SN: 25AEX TX-826 1-96-005 RC-176819 1R141XRCOOO1A WESTINGHOUSE VALVE REPLACED STEM AND B.R. RUSSELL 7/29/96 SN: W750001 LINK ASSEMBLY TX-826 NB: W14271 Page 2

SOUTH TEXAS PROJECT UNIT - 1 ASME CODE SECTION - XI 1RE06 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 & 2)

R OR R SR PROJ. ID OF MFG SN AND NB ITEM / COMP R OR R COMP.

NO.

NO.

ITEM (TPNS NO.)

(IF ANY) OF COMP.

DESCRIPTION DESCRIPTION ANil DATE 1-96-006 RC-176815 1R141XRCOOO18 WESTINGHOUSE VALVE REPLACED STEM AND B. R. RUSSELL 7/29/96 SN: W750011 LINK ASSEMBLY TX-826 NB: W18058 1-96-007 MS-341349 A1MSPV7411 CONTROL COMP. INC.

VALVE REPLACED PLUG B.R. RUSSELL 7/22/96 SN: 35199-1-2 TX-826 1-96-008 MS-331143 NIMSPSV7430A DRESSER SAFETY VALVE REPLACED DISC B. R. RUSSELL 7/25/96 SN: BT-02172 TX-826 1-96-015 CV-341887 2R171TCVO145A ROCKWELL VALVE REPLACED PLUG B.R.RUSSEL*_

7/22/96 SN: 1-183 TX-826 1-96-018 MS-341336 NIMSPSV7430B DRESSER SAFETY VALVE REPLACED DISC B. R. RUSSELL 7/22/96 SN: BT-02176 TX-826 1-96-038 CV-325116 2R171TCVO754 EDWARD VALVES VALVE INSTALLED A NEW B. R. RUSSELL 6/27/96 SN: XJ-51 VALVE IN EXISTING TX-826 LINE (3* CV-1215) 1-96-039 SG-203221 1R121NSG101C WESTINGHOUSE STEAM REPLACED SECONDARY B.R. RUSSELL 7/22/96 SN: 2133 GENERATOR SIDE MANWAY COVER TX-826 NB: W18693 1-96-043 SG-325405 1R121NSG101A WESTINGHOUSE STEAM REPAIRED BOLT HOLE B. R. RUSSELL 7/29/96 SN: 2131 GENERATOR TX-826 NB: W18691 Page 3

SOUTH TEXAS PROJECT UNIT - 1 ASME CODE SECTION - XI 1RE06 INSERVICE INSPECTION

SUMMARY

REPORT FOR REPAIRS AND REPLACEMENTS (CLASS 1 & 2)

R OR R SR PROJ. ID OF MFG. SN AND NB ITEM / COMP R OR R COMP.

NO.

NO.

ITEM (TPNS NO.)

(IF ANY) OF COMP.

DESCRIPTION DESCRIPTION ANil DATE 1-96-046 SG-325408 1R121NSG101D WESTINGHOUSE STEAM REPAIRED BOLT HOLE B.R. RUSSELL 7/29/96 SN: 2134 GENERATOR TX-826 NB: W18694 1-96-059 CV-344272 2R171TCV0248B ANCHOR DARLING VALVE REPLACED VALVE B. R. RUSSELL 7/29/96 SN: ET550-10-13 TX-826 1-96-062 SN-311279 2C111XSfkf04A TELEDYNE BROWN STM. GEN. (1 A)

REMOVED METAL FROM B. R. RUSSELL 7/29/96 ENGINEERING UPPER LATERAL CLEVIS END TO RELIEVE TX-826 SN: 401-21 (PART No.)

SUPPORT THE SNUBBER BINDING Page 4

F-089T-b46P-082/0G2nUG08'E516:18 8048320602 FRAf1ATOME TECH ltC l

l l

F RAMATO M E 7ECHHOL0$IE3 Te Eth Moser, South,Te as Project 20553A-6(11/95) x From customer j

Randy Schaef,

SG Product Development, x4009 or nie Topical.rrs l

Subj.

Dete Electrosiceve" Questions 8/8/96 t

This memo is in response to your questions per telecon on August b,1996.

Question 1) Are the compressive stesses in the tube due to the installation of an l

electrosleeve"in the longitudinal and hoop directions?

The resulting stresses in the tube due to the installation of an electrosleeeve" are l

compressive at the tube outside surface and are approximately 25 to 30,kai,in both the longitudinal and hoop directions. These stresses exist only in the tube behind the sleeve.

These stresses reduce through the tube thickness and are balanced by tensile stresses in the sleeve.

l Tube buckling cannot occur due to these compressive stresses due to the short tube length l

affected and the thickness of the sleeve / tube combinathn.

For a tube locked into the TSPs, a small tensile loading may develop as a result of these l

compressive stresses. The worst case tube c6uld see a 3.2 ksi tensile stress in the unsleeved portion of the tube span.

Question 2) is the 140F plating temperature the result of a exothermic reaction?

No.

l The 140F plating fluid temperature is the result of heaters placed in the solution tanks and along the process delivery hose. This 140F fluid temperature at the probe represents a proferred process temperature.

l l

cc:

JE Galford PM Mastilovic JR Pugh

80483206G2 FRAMATOME TECH INC F-089 T-246 P-002/002 AUG 08 '95 16:18 1

l F RAMATO M E TECHNOL068ES l

To l

Keith Moser, South Texas Project 20553A-6(11/951 nw i

Fmm Customer l

Randy Schaef,

SG Product Development, x4009 or File Topical.rrs l

suti.

Date Electrosiceve" Questions 8/8/96 i

This rnemo is in response to your questions per telecon on August 8,1996.

l Ouestion 1) Are the compressive stesses in the tube due to the installation of an electrosleeve"in the longitudinal and hoop directions?

The resulting stresses in the tube due to the installation of an electrosleceve" are compressive at the tube outside surface and are approximately 25 to 30,ksi,in both the l

longitudinal and hoop directions. These stresses exist only in the tube behind the sleeve.

l These stresses reduce through the tube thickness and are balanced by tensile stresses in the l

sleeve.

Tube buckling cannot occur due to these compressive stresses due to the short tube length affected and the thickness of the sleeve / tube combination.

l For a tube locked into the TSPs, a small tensile loading may develop as a result of these l

compressive stresses. The worst case tube c6uld see a 3.2 ksi tensile stress in the unsleeved portion of the tube span.

I i

l Ouestion 2) is the 140F plating temperature the result of a exothermic reaction?

No.

l The 140F plating fluid temperature is the result of heaters placed in the solution tanks and along the process delivery hose. This 140F fluid temperature at the probe represents a preferred process temperature.

cc:

1 JE Galford PM Mastilovic JR Pugh