Forwards Revised Page 7,correcting Item 2 Re Total Fissile U Consumed for Current & Extended License Periods.Pounds to Kg Conversion Factor Inadvertently Omitted from 860822 Submittal
ML18149A456
Person / Time
Site: Surry  
Issue date: 12/10/1986
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Rubenstein L
Office of Nuclear Reactor Regulation
References
86-496B, TAC-62280, TAC-62281, NUDOCS 8612120284
Download: ML18149A456 (3)


Text

e e

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 W. L. STEWART VICE PRESIDENT NUCLEAR OPERATIONS December 10, 1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Lester S. Rubenstein, Director PWR Project Directorate No. 2 Division of PWR Licensing-A U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 Serial No.

NO/JDH Docket Nos.

License Nos.

ADDITIONAL INFORMATION REGARDING 40 YEAR OPERATING LICENSES 86-496B 50-280 50-281 DPR-32 DPR-37 On December 5, 1986 (Serial No. 86-496A) we provided additional information regarding 40 year operating licenses for Surry 1 and 2 which supplemented our original August 22, 1986 (Serial No.86-496) request.

We subsequently noted one error in our December 5, 1986 submittal.

On Page 7, Item 2, we discuss the total fissile uranium consumed for the current and extended license periods.

During our calcula-tions, we inadvertently omitted the pounds to kilograms conversion factor.

With the correct conversion factor applied during the calculations, the total fissile uranium consumption over the extended license period is still bounded by the total four unit uranium consumption values previously accepted by NRC in the Surry FES's.

A revised Page 7 with Item 2 corrected is attached.

We regret any inconvenience caused by this error.

Very truly yours,

~w~!:;-

Attachment 8612120284 861210 PDR ADOCK 0500~fi~O p

cc:

Dr. J. Nelson Grace Regional Administrator NRC Region II Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station Mr. Charles Price Department of Health 109 Governor Street Richmond, Virginia 23219 Mr. Chandu P. Patel NRC Surry Project Manager PWR Project Directorate No. 2 Division of PWR Licensing-A e

7 ENVIRONMENTAL IMPACTS (Uranium Fuel Cycle)

The impact of the uranium fuel cycle was considered in the Final Environmental Statement for Unit 1 (May 1972) and Unit 2 (June 1973).

In Section IX of the Unit 1 and the Unit 2 FES, each unit was estimated to operate for 30 years.

Enrichments of approximate-ly 3.1% and annual refuelings were assumed for both units.

The environmental impact on the uranium fuel cycle was found to be acceptable.

Since that time, two license amendments (Amendment Nos. 66/65 on February 25, 1981 and Amendment Nos. 73/74 on January 19, 1982) allowed an increase in the limiting reload enrichments specified in Technical Specification 5.A.3 from an original maximum reload enrichment of 3.6% to the current limit of 4.1% thus allowing longer operating cycles in lieu of the 12 month cycles assumed in the FES.

In each case, the environmental considerations were assessed and the NRC staff concluded that the amendments would not result in any significant environmental impact.

In assessing the impact on the uranium fuel cycle for the addition-al four years operation for Unit 1 and 4 1/2 years operation for Unit 2 (approximately 8 1/2 reactor-years additional operation), we have considered the following factors:

1.

The additional years of reactor operation would almost propor-tionally increase the total fissile uranium required.

This impact is justified in light of the continued benefit received from station operation.

2.

The units are expected to consume 19,380 kg of fissile uranium for Unit 1 and 19,388 kg of fissile uranium for Unit 2 over the current licensed periods.

This is expected to increase to 21,722 kg for Unit 1 and 22,180 kg for Unit 2 consumed over the extended 40 year period.

Therefore a 2 unit total of 38,768 kg for the current licensed period and 43,902 kg for the extended period are expected to be consumed.

These values were calculated based on the actual uranium loadings for past and current cycles and projected loadings for future

cycles, and were converted to the amount of uranium loaded which is actually consumed.

The Surry 1 and Surry 2 FES's gave values of 15,900 kg each for the expected fissile uranium to be consumed during the life of the reactors.

The Surry 3 and 4 FES gave a combined value of 51,000 kg for the expected fissile uranium consump-tion for Unit 3 and 4.

The total four unit consumption is 82,800 kg.

Thus, the total predicted value for Units 1 and 2 of 43,902 kg over the extended license periods is still bounded by the four unit total uranium consumption value accepted by the NRC in the FES's.

Based on our review of the previous NRC findings supporting two license amendments regardipg increases in enrichments, the lack of adverse impact on the fuel cycle due to increased enrichments, and the previous FES assessment for the units, we have determined that the FES values for consumed fissile uranium remain bounding for the additional operating period.