ML18152B417
| ML18152B417 | |
| Person / Time | |
|---|---|
| Site: | Surry |
| Issue date: | 05/17/1999 |
| From: | Mccarthy J VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| To: | NRC (Affiliation Not Assigned) |
| References | |
| 99-273, NUDOCS 9905210220 | |
| Download: ML18152B417 (3) | |
Text
CATEGORY 1 REGULAl.Y INFORMATION DISTRIBUTIO.YSTEM (RIDS)
ACCESSION NBR:9905210220 DOC.DATE: 99/05/17 NOTARIZED: NO DOCKET#
FACIL:50-281 ~urry Power Station, Unit 2, Virginia Electric & Powe 05000281 AUTJ;~.:WW,&
AUTHOR AFFILIATION MCCAR'tHY/J.H.
Virginia Power (Virginia Electric & Power Co.)
RECIP.NAME RECIPIENT AFFILIATION
SUBJECT:
Provides notification of number of steam generator tubes that were plugged during spring 1999 Refueling Outage.
DISTRIBUTION CODE: AOOlD COPIES RECEIVED:LTR _(_ENCL{)
SIZE:~~~~~~
TITLE: OR Submittal: General Distribution NOTES:
05000281 RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-1 LA 1
PD2-1 PD 1
EDISON,G.
1 INTERNAL: ACRS 1
(!ILE CENTE~ 1 NRR/DE/EEIB 1
NRR7DE7EMCB 1
NRR/DE/EMEB 1
NRR/DSSA/SPLB 1
NRR/DSSA/SRXB 1
NRR/SPSB JUNG,I 1
NUDOCS-ABSTRACT 1
OGC/RP 1
EXTERNAL: NOAC 1
NRC PDR 1
NOTES:
1 NOTE TO ALL "RIDS" RECIPIENTS:
C A
T E
G 0
R y
1 D
0 C
u M
.E N
T PLEASE HELP US TO REDUCE WASTE,. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 16 ENCL'
e VIRGINIA. ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 May 17, 1999 Director of Nuciear Reactor Regulation Serial No.:
99-273 United States Nuclear Regulatory Commission Washington, DC 20555-0001 NLOS/mm Docket No.:
50-281 License No.: DPR-37 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 2 STEAM GENERATOR TUBE INSPECTION REPORT Planned inservice inspection of the Surry Unit 2 "A" steam generator was completed during the spring 1999 Refueling Outage.
In accordance with Surry Power Station Technical Specification 4.19.F.a, this letter provides notification of the number of steam generator tubes that were plugged during the outage. The. following nine tubes were plugged:
Steam Generator "A" Row Column 1
36 4
43 4
45 6
38 Specifics Tube was preventively plugged because it would not allow passage of a standard 0.720 inch eddy current probe. This tube did allow passage of a 0.680 inch eddy current probe.
The tube was examined to the extent practicable and no defects were found.
Plugged fc;>r a pit-like indication on the cold leg side of the steam generator at 2.44 inches above the tube sheet..
Plugged for two pit-like indications on the cold leg side of the steam generator at 2.3 and 3.2 inches above the tube sheet.
Plugged for two pit-like indications on the cold leg side of the steam generator at 3.8 and 4.2 inches above the tube sheet.
9905210220 CJ90517
1 PDR ADOCK 65000281 I
p p~
'7 e
7 36 7
49 7
57 9
51 Steam Generator "C" Row Column 25 13 Plugged for a pit-like indication on the cold leg side of the steam generator at 4. 7 inches above the tube sheet.
Plugged for two pit-like indications on the cold leg side of the steam generator at 4.27 and 5.47 inches above the tube sheet.
Plugged for a pit-like indication on the cold leg side of* the steam generator at 3.06 inches above the tube sheet.
Plugged for a pit-like indication on the cold leg side of the steam generator at 3.19 inches above the
- tube sheet.
Specifics Plugged for a pit-like indication on the cold leg side of the steam generator at 2.2 inches above the tube sheet.
No new commitments are being made as a result of this letter.
If you have any questions concerning these results, please contact us.
Very truly yo __ u_rs ___