Text
.
.
. L&
Aj_M
.
U.
NUCLEAR REGULATORY C01^11SSION
-
.
,
0FFICE,OF INSPECTION AND E iFORCEMENT
,
,
REGION V
.~
.
50-139/75-01 ) IE-V-64
'
4IE Inspection Report No.
70-115/75-01 )
50-139 Licensee University of Washinaton Docket No.70-115 R-73
-
-
"
License No. Sf'M-108
-
R-73/F-2
.
Priority SNM-108/4-2
Facility Nuclear Reactor Laboratory Category
.
Location Seattle, Washinoton
.
Type of Facility Academic Institution Type of Inspection Announced
.
Dates of Inspection June 2-3. 1975 Dates of Previous Inspection flone
3 7[
Principal Inspector e
.
Date
. Kobori, Auditor
-
Accompanying Inspectors
[O' ' "
7$
.
G. H. Hamada, Chemist / Statistician Date Date
-
Other Accompanying Personnel:
None Reviewed by
/
.<'-
)
f
'
V. N. Rizzobbhief, Materials and Plant D^t" Protection Branch 8204210618 011110
~
PDR FOIA POLLOCK81-399 PDR IE-V-52 Copy ?!o.
'/
.
'
.
"
'
-
,
,
REPORT OF INSPECTION OF SAFEGUARDS CONTROL OF NUCLEAR 1%TERIALS AT
,
UNIVERSITY OF WASHINGTON SEATTLE, WASHINGTON
. A.-
INTRODUCTION
.
.
1.
Inspection dates at the University of Washington were June 2-3, 1975.
This was the first safeguards inspection of this licensee.
2.
The current inspection covered the status of safeguards controls as of the inspection dates, June 2-3, 1975.
3.
University of Washington, a State run nonprofit educational institution, has limited quantities of special nuclear material (SNM) for use in the conduct of educational activities. These quantities include, primarily, fuel for a research reactor (Argonaut-type), Pu/Be neutron sources, and small amounts of U-235 (93%), U-233 and Pu foils which, except for some scrap, are all in encapsulated form.
The University has a6 Argonaut-type training reactor located on campus with an authorized power level of 100 KW (thermal).
4..
University of Washington currently holds two licenses, SNM-108 and R-73 for SNM.
,
B.
SCOPE OF INSPECTION 1.
University of Washington is designated a Group II licensee for safeguards purposes and is exempt from major portions of 10 CFR 70.51 and 70.58.
This inspection, therefore, covered only the applicable requirements of Part 70 and the AEC licenses.
.
2.
The inspect' ion included the following:
a.
Review of records, reports and source documents, b.
Review of material control procedures.
A ' physical inventory of SNM.
c.
d.
Determination of compliance with applicable requirements of 10 CFR 70, "Special Nuclear Materials."
.
_
-
-.
.
.
.
.
m
.
-
.
.
-2-C.
SUiMARY OF FINDIllGS 1.
Determined that the licensee had not developed, established, or maintained written nuclear material control and accounting procedures for use in accounting for SilM in his possession under license.
2.
Determined that the licensee was currently in full compliance with remaining applicable requirements of 10 CFR 70, "Special Nuclear flaterials."
3.
Enforcement Action Violations
?
None.
-
Infractions Contrary to 10 CFR 70.51(c), the fluclear Reactor Laboratory did not develop and maintain' written nur. lear material control and accounting procedures as required.
Deficiencies
!
None.
D.
LICENSEE ACTION ON PREVIOUSLY IDENTIFIED ENFORCEf1ENT ITEMS Not applicable.
E.
UNUSUAL OCCURRENCES None.
.
F.
OTHER SIGNIFICANT FINDINGS l
Current Findings l
'
None.
l Status of Previously Reported Unresolved Items l
None.
-
l
l.
.
.
.
.
.
.
._ -
. _Co.. A ye
- ~3
=~
m
-
_
.
-3-
,
G.
MANAGEMENT INTERVIEW The results cf the inspection were discussed with Dr. G. Woodruff, Director, Nuclear Engineering Laboratories; A. Wakefield, Assistant to Director; and W. P. Miller, Manager, Nuclear Reactor Laboratory Operations, at the conclusion of the inspection of June 3,1975.
H.
REPORT DETAILS 1.
Individuals contacted Gene L. Woodruff, Director, Nuclear Engineering Laboratories W. P. Miller, Manager, Nuclear Reactor Laboratory Operations A. Wakefield, Assistant to Director 2.
Physical Inventory of Nuclear Materials Except for a single item consisting of encapsulated U-235 foils which is kept in a vault in the Cyclotron Building, all other SNM materials were housed in the Nuclear Reactor Building.
a.
Argonaut-type Training Reactor (License No. R-73)
This reactor is housed in a building of its own and is under the direction of Dr. Gene L. Woodruff, Director.
Nuclear Engineering Laboratories.
Dr. Woodruff serves
'
under Dr. A. L. Babb, Professor and Chairman, Department of Nuclear Engineering.
An SNM license, SNM-108, Amendment 2, also permits possession and use of certain SNM materials for other than reactor related activities.
(1)
The inventory held under the R-73 license was as follows:
I l
Symbol - ZXW-(Fuel)
Element Isotope
'
3688 gms (U)
3437gms(U-235)
l (cold)
668gms(U)
623 gms (U-235)
i 224 gms (U)
209 cms (U-235)
,
Totals *
4580 gms (U)
4269 gms (U-235)
Totals **
4574 gms (U)
4261 gms (U-235)
.
- Not corrected for burnup.
'
- Corrected for burnup to 12/74.
.
.-
- - - -
.
..
.,
'
eM... - -
_
.x
,
-
_ - _
_
.
-4-Symbol - ZXW-(Other)
Element Isotope
-
Metal Chips & Slugs 29.7 gms (U)
27.7 gms (U-235)
(remnants of orig.
fuel material)
~
(2)
The inventory held under SNM-108 was as follows:
Symbol - ZXW Element Isotope
'
Pu/Be Source M-83 15.82 gms Pu 14.72 gms Pu fissile
"
"
M-84 15.96 14.86
"
"
M-85 15.97 14.87
"
"
"
"
"
"
M-86 15.99 14.88
"
"
"
"
M-87 15.93 14.83
"
"
"
"
M-915 31.99 30.00
"
"
Total 111.66 gms 104.16 gms Fission Counter 1.84 gms U l.72 gms U-235 Symbol - HAY Element Isotope 1 Capsule of Encap-17. 7 gms (U)
16.5 gms (U-235)
sulated U Foils Scrap U Foil 7. 2 gms (U)
6.7 gms (U-235)
1 Capsule of Encap-24.16 gms (Pu)
2I. gms (Pu fissile)
sulated Pu Foils 1 Capsule of Encap-13. O gms (U)
12.9 gms (U-235)
sulated U-233 Foils Total 24. 9 gms (U)
23.2 gms (U-235)
'
Total 24.16 gms (Pu)
22 gms (Pu fissile)
Total 13. O gms (U)
12.9 gms (U-233)
l b.
Except for the fuel in the reactor and the two bundles of irradiated fuel in cooling, all other items were accounted for and identified by serial number and/or other markings.
The irradiated bundles were viewed in place in the storage wells, but no attempt was made to read their serial number..
-
.-
,
'
-
.
-
_-
.
%,
xy g=
- -
,
-5-c.
A copy of a computer run of their burnup calculations was obtained.
Burnup calculations are performed semi-annually using standard procedures. A conversion factor of 1.25 grams U-235 consumed per megawatt-day is applied to the power output.
The U-236 production is also accounted for in the calculation.
The U-235 consumed for the period July 1974 through December 1974 was 0.327 grams. The U-235 consumed overall, from April 1961 through December 1974 was 8.2 grams.
3.
Records and Reports
.
The licensee maintains files of Forms AEC-741, " Nuclear Material Transaction Report" (and its predecessor Form AEC-388), and Forms AEC-742, " Material Status Report," supplemented by inventory listings as his formal record. The licensee holds SNM under two separate reporting identification symbols (RIS),
HAY and ZXW.
Separate document files are maintained by RIS.
Establishment of a simplified ledger type record was suggested to the licensee, although it is not required by existing regulations.
The inspection disclosed that the licensee had not prepared written material control or accounting procedures (sufficient to enable the licensee to account for the SNM in his possession under license) as required by 10 CFR 70.51(c).
The licensee indicated that procedures did not then exist separately or in conjunction with other laboratory procedures (such as the radiation safety manual).
However, practices in material control and accounting were determined to be adequate.
Reporting identification symbol HAY is assigned to the University of Washington by the Richland Operations Office of j
the Energy Research and Development Administration (ERDA).
Symbol ZXW is assigned to the University for reporting of all
'
,
other SNM materials held at the Nuclear Reactor Laboratory, I
other than HAY material.
Presently, all ZXW inventory is ERDA leased material supplied under ERDA educational assistance programs.
With the exception of 10 CFR 70.51(c), the University has satisfactorily complied with applicable requirements of 10 CFR 70, such as Parts 70.51(b) with respect to records and Parts 70.52, 70.53a and 70.54 with respect to reporting.
.
-
- - - - -
.
.
'
.
.
.
.
,
'
'
y g i TiG _E s C Z ' "' -
,
,
.
-6-4.
Nuclear Material Balances (June 3,1975)_
Summary material balances from licensee's records are as
-
follows:
.
Symbol - HAY Element Isatope Enriched Uranium 25 gms U 23 gms U-235 Plutonium 24 gms Pu 22 gms Pu fissile U-233 13 gms U 13 gms U-233 Symbol - ZXW Element Isotope
,
Enriched Uranium 4,605 gms U 4,288 gms U-235 Plutonium 112 gms Pu 104 gms Pu Fissile All uranium included above was enriched to approximately 93 percent U-235.
.
.
d e
.W
.
-
- -