IR 05000269/1982020

From kanterella
Jump to navigation Jump to search
IE Enforcement Meeting Repts 50-269/82-20,50-270/82-20, 50-287/82-21 & 50-369/82-19 on 820521.No Noncompliance Noted.Major Areas Discussed:Corrective Actions Re Breach of Reactor Bldg Integrity Due to Uncapped Calibr Line
ML20054K129
Person / Time
Site: Oconee, McGuire, 05000000
Issue date: 06/11/1982
From: Robert Lewis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20054K128 List:
References
50-269-82-20, 50-270-82-20, 50-287-82-21, 50-369-82-19, NUDOCS 8207010143
Download: ML20054K129 (2)


Text

-

UNITED STATES

4, NUCLEAR REGULATORY COMMISSION

'

e REGION 11 o,4 gf 101 MARIETTA ST., N.W., SUITE 3100 g***** g ATLANTA, GEORGIA 30303 Report Nos. 50-269/82-20, 50-270/82-20, 50-287/82-21 and 50-369/82-19 Licensee: Duke Power Cmpany.

P. O. Box 2178 01arlotte, NC 28242 Facility Name: Oconee Uni ts 1, 2, 3 and McGui re Uni t 1 Docket No. 50-269, 50-270. 50-287 and 50-369 License Nos. DPR-38, DPR-47, DPR-55 and NPF-9 Moctirg at the Region 11 office Approved by:

~. 6,

.

d////fL

~

. C. Leyfi s, irector, PRP Division Dat6 Signed SU,t#RY An enforconent meeting was held on May 21, 1982 to discuss corrective actions concerning breach of reactor building integrity due to an uncapped calibration line connected to a sensing line for reactor buildirg pressure switch 1PS-22.

This finding will be described in special inspection report 50-269/82-11. Other inspection findings were also discussed.

.

8207010143 820615 PDR ADOCK 05000269 G

PDR

[

_ _ _ _ _ _ _

..

o DETAILS 1.

Personnel Attending Meeting Duke Power Company (DPC)

W. 0. Parker, Jr., Vice President, Steam Production H. B. Tucker, hunager, Nuclear Production J. Ed. Smith, Oconee Station Manager M. D. McIntosh, McGuire Station Manager R. C. Adams, I&E Engineer R. T. Bond, Licensing Engineer Region II R. C. Lewis, Director, Division of Project and Resident Programs J. A. Olshinski, Director, Division of Engineering and Technical Programs H. C. Dance, Chief, Reactor Projects Branch No. 2, PRP e

J. C. Bryant, Chief, Reactor Projects Section 2A, PRP F. Jape, Chief, Test Program Section, ETP W. T. Orders, Oconee Senior Resident Inspector A. J. Ignatonis, Project Inspector 2.

Management Meeting NRC representatives expressed their concerns regarding the licensee's failure to follow procedures requiring replacement of an instrument calibration line cap which resulted in an open line penetrating the Oconee 1 reactor building and which degraded the initiation logic for Train A of the reactor building spray system. Other recent inspection findings at Oconee and at McGuire were also discussed. These findings pertained to failure of licensee controls in the areas of communication between plant station groups; the following of controlling procedures; and the accuracy and completeness of reportable occurrence reports. The DPC representatives acknowledged their understanding of the findings and proposed corrective actions to prevent recurrence.