05000387/LER-1982-057, Forwards LER 82-057/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 82-057/03L-0
ML20071Q847
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 12/20/1982
From: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20071Q849 List:
References
NUDOCS 8212290441
Download: ML20071Q847 (1)


LER-2082-057, Forwards LER 82-057/03L-0
Event date:
Report date:
3872082057R00 - NRC Website

text

-

y .

s. o Q Pennsylv nle Pow;r & Light Company Two North Ninth Stre < A:lentown, PA 18101
  • 215/ 770 5151 December 20, 1982 Mr. R.C. Ilaynes Director, Region I U.S. Nucicar Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 SUSQUEHANNA STEAM ELECTRIC STATION LICENSEE EVENT REPORT 82-057/03L-0 ER 100450 FILE 841-23 Docket No. 50-387 PLA-1447 License No. NPF-14

Dear Mr. Ilaynes:

Attached please find a copy of Licensee Event Report No. 82-057/03L-0.

This event was determined to be reportable per Technical Specification 6.9.1.9.b in that the Reactor Cere Isolation Cooling was inoperable when the ramp generator failed during a Startup Test.

-Q'f// d'PU /s ll.W. Keiser Superintendent of Plant-Susquehanna DGM/cw cc: A. Schwencer Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555 G. Rhoads Resident Inupector U.S. Nuclear Reguintory Commission P.O. Box 52 Shickshinny, PA 18655

("212290441 821220 PDR ADOCK 05000387 6 PDR

_ u