Forwards GE Rept, Susquehanna Unit 1 CRD Housing Cap Screw Corrosion. Rept Completes Action on Item
ML18040A906
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 07/21/1988
From: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
To: Russell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML17156A693 List:
References
PLA-3062, NUDOCS 8808010216
Download: ML18040A906 (2)


Text

ACCELERATED DI JBUTION DEMONSTRATION SYSI'EM p REGULAT INFORMATION DISTRIBUTIO YSTEM (RIDS)

ACCESSION NBR:8808010216 DOC.DATE: 88/07/21 NOTARIZED: NO DOCKET FACIL:50-387 Susquehanna Steam Electric Station, Unit 1, Pennsylva 05000387 50-388 Susquehanna Steam Electric Station, Unit 2, Pennsylva 05000388 AUTH. NAME AUTHOR AFFILIATION KEISERiH.W. Pennsylvania Power & Light Co.

RECIP.NAME RECIPIENT AFFILIATION RUSSELL,W.T. Region 1, Ofc of the Director

SUBJECT:

Forwards util rept on control drive housing cap screw R corrosion.

DISTRIBUTION CODE: IEOlD TITLE: General (50 Dkt)-Insp Rept/Notice of COPIES RECEIVED:LTR t ENCL Violation I

SIZE:

Response

f'5 D NOTES:LPDR 2 cys Transcripts. 050003878 LPDR 2 cys Transcripts. 05000388 RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD1-2 PD 1 1 THADANI,M 2 2 4

INTERNAL: ACRS 2 2. AEOD 1 1 NRR MORISSEAU,D DEDRO NRR/DLPQ/PEB NRR/DOEA DIR ll ll 1

1 1

1 1

1 NRR/DLPQ/QAB 10 NRR/DREP/EPB 10 1

1 1

1 1

1 NRR/DREP/RPB 2 2 NRR/DRIS DIR 9A 1 '

1 10'RR/PMAS/ILRB12 1 1 NUDOCS-ABSTRACT 1 OE LIEBERMANgJ 1 1 OGC 15-B-18 1 1 1 1 RES/DSIR DEPY 1 1 R FILE 01 1 1 EXTERNAL: LPDR 2 2 NRC PDR 1 1 NSIC 1 1 NOTES: 2 2 S

TOTAL NUMBER OF COPIES REQUIRED: LTTR 28 ENCL 28

I I

~PQQQ, Pennsylvania Power 8 Light Company Two North Ninth Street ~ Allentown, PA 18101-1179 ~ 215m0-5151 JUL 21 1988 Harold W. Keiser Senior Vice President-Nuclear 21 5/770.4194 Mr. William T. Russell Regional Administrator Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 SUSQUEHANNA STEAM ELECTRIC STATION CRD BOLT REPORT Docket Nos. 50-387 PLA-3062 FILE R41-2 and 50-388

Dear Mr. Russell:

As requested by your staff, attached is a copy of General Electric's Report on the Control Rod Drive Housing Cap Screv Corrosion. This letter completes our action on this item.

Very truly yours, H. W. Keis Attachment NRC Region I Mr. M. C. Thadani, NRC Project Manager Mr. F. I. Young, NRC Sr. Resident Inspector 88080i02ib 88072i P