05000387/LER-1982-025, Forwards LER 82-025/01T-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-025/01T-0.Detailed Event Analysis Encl
ML20066B121
Person / Time
Site: Susquehanna 
Issue date: 10/26/1982
From: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20066B123 List:
References
PLA-1367, NUDOCS 8211060403
Download: ML20066B121 (2)


LER-1982-025, Forwards LER 82-025/01T-0.Detailed Event Analysis Encl
Event date:
Report date:
3871982025R00 - NRC Website

text

..

PPat Pannsylv nia Powcr & Light Company Two North Ninth Street

  • Allentown, PA 18101
  • 215/ 770 5151 i

October 26, 1982 Mr. R.C. Haynes Director, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 SUSQUEHANNA STEAM ELECTRIC STATION LICENSEE EVENT REPORT 82-025/0lT-0 ER 100450 FILE 841-23 Docket No. 50-387 PLA-1367 License No. NPF-14

Dear Mr. Haynes:

Attached please find a copy of Licensee Event Report No. 82-025/01T-0.

This event was determined to be reportable per Technical Specification 6.9.1.8.b, in that the chlorine detectors were declared inoperable and the action statement could not be complied with. This occurred due to an inconsistancy in the Technical Specifications allowing both Control Room Emergency Outside Air Supply Systems to be taken out of service.

f 6

H.W. Keiser Superintendent of Plant-Susquehanna DGM/cw cc:

A. Schwencer Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555 G. Rhoads Resident Inspector U.S. Ficlear Regulatory Commission P.O. Box 52 Shickshinny, PA 18655 8211060403 821026 PDR ADOCK 05000387 S

PDR gc+

Attachment Licensee Event Report 82-025/0lT-0 While in an outage from startup testing, in Operational Condition 4, both chlorine detectors were declared inoperable due to a lack of electrolyte.

The action statement requires one Control Room Emergency Outside Air Supply System train be put in recirculation. At this time, it was noted that both CRE0 ASS trains were out of service for modifications. The CRE0 ASS specifi-cation allows both trains to be inoperable in 0.C. 4, provided core alterations are suspended.

Because the CRE0 ASS action statement allowed both trains to be inoperable, the chlorine action statement could not be adhered to and the unit was in a condition less conservative than permitted by the action state-ment.

One chlorine detector was returned to service within approximately 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />, and the remaining detector was operable shortly thereafter. To prevent recurrence, the operators reviewed the event and were cautioned as to releasing equipment from service.

Further; a Technical Specification change will be submitted to delete the inconsistancy in the two specifications.