05000387/LER-1982-052, Forwards LER 82-052/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 82-052/03L-0
ML20070F994
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 12/07/1982
From: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20070F997 List:
References
PLA-1426, NUDOCS 8212210343
Download: ML20070F994 (1)


LER-2082-052, Forwards LER 82-052/03L-0
Event date:
Report date:
3872082052R00 - NRC Website

text

_ _ _ _ _ _ _ _ _ _ _ _

Pennsylvania Power & Light Company Two North Ninth Street

  • Allentown, PA 18101
  • 2151 770 5151 December 7, 1982 Mr. R.C. Haynes Director, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 SUSQUEHANNA STEAM ELECTRIC STATION LICENSEE EVENT REPORT 82-0'> 2 /03L-0 ER 101450 FILE 841-23 Docke t No. 50-387 PLA- 1426 License No. NPF-14

Dear Mr. Haynes:

Attached please find a copy of Licensee Event Report No. 82-052/03L-0.

This event was determined to be reportable per Technical Specification 6.9.1.9.b, in that the dif ferential pressure instrument indicated Zone I of the secondary containment failed to maintain the required vacuum.

H.W k e Superintendent of Plant-Susquehanna DGM/cw cc: A. Schwencer Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555 G. Rhoads Resident Inspector U.S. Nuclear Regulatory Coraission P.O. Box 52 Shickshinny, PA 18655 8212210343 821207 PDR ADOCK 05000387 @

S PDR

. - - ,k e Pennsylv::nia Pow:r & Light Comp:ny Two North Ninth Street

  • Allentown, PA 18101
  • 215/ 770 5151 l

December 7, 1982 Mr. R.C. Haynes Director, Region I U.S. Nuclear Regul.atory Commission 631 Park Avenue King of Prussia, PA 19406 SUSQUEuANNA STEAM ELECTRIC STATION LICENSEE EVENT REPORT 82-052/03L-0 ER 100450 FILE 841-23 Docket No. 50-387 PLA- 1426 License No. NPF-14

Dear Mr. Haynes:

Attached please find a copy of Licensee Event Report No. 82-052/03L-0.

This event was determined to be reportable per Technical Specification 6.9.1.9.b, in that the differential pressure instrument indicated Zone 1 of the secondary containment failed to maintain the req' aired vacuum.

/ //f(

H.W/* ise/Mr Superinten ent of lant-Susquehanna DGM/cw cc: A. Schwencer  ;

Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555 G. Rhoads (

i Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 52 Shickshinny, PA 18655 l

I 8212210343 821207 PDR ADOCK 05000387 t, '

S PDR L

__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - . _ _ _ _ - - - - _ _ _ _ _ _