05000387/LER-1982-033, Forwards LER 82-033/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 82-033/03L-0
ML20066B025
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 10/29/1982
From: Keiser H
PENNSYLVANIA POWER & LIGHT CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20066B027 List:
References
PLA-1374, NUDOCS 8211060346
Download: ML20066B025 (1)


LER-2082-033, Forwards LER 82-033/03L-0
Event date:
Report date:
3872082033R00 - NRC Website

text

m

)

... o PPat P;nnsylvcnio Pow;r & Light Company Two North Ninth Street

  • Allentown, PA 18101
  • 2151 770 5151 October 29, 1982 Mr. R.C. Haynes Director, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia. PA 19406 SUSQUEHANNA STEAM ELECTRIC STATION LICENSEE EVENT REPORT 82-033/03L-0 ER 100450 FILE 841-23 Docket No. 50-387 PLA-1374 License No. NPF-14

Dear Mr. Haynes:

Attached please find a copy of Licensee Event Report 82-033/03L-0.

This event was determined to be reportable per Technical Specification 6.9.1.9.b in that the pump for the Reactor Building SPING System tripped off and back-up sampling was initiated.

" // 60f 29 J H.W.Ke/ ,iser 7, / #,

Superintendent of Plant-Susquehanna DGM/cv cc: A. Schwencer Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555 G. Rhoads Resident Inspector s U.S. Nuclear Regulatory Commission P.O. Box 52 Shickshinny, PA 18655 s

[

I 0211060346 821029

~

PDR ADOCK 05000387 S PDR 36*

~ ~ ~ . . _

N