CATEGORY 2 REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9801220137 DOC.DATE: 98/01/07 NOTARIZED: NO DOCKET ¹ FACIL:50-387 Susquehanna Steam Electric-Station, Unit 1, Pennsylva 05000387 50-388 Susquehanna Steam Electric Station, Unit 2, Pennsylva 05000388 AUTH.NAME AUTHOR AFFILIATION ANDERSON,C.J.
Region 1 (Post 820201)
RECIP.NAME RECIPIENT AFFILIATION BYRAM,R.G.
Pennsylvania Power
&, Light Co.
SUBJECT: Ack receipt of 971222 ltr informing NRC of steps taken to correct violations noted in insp repts 50-387/97-04 50-388/97-04 on 970805.Actions will be examined during future insp of licensed program.
DISTRIBUTION CODE: IEOID COPIES RE CEIVED:LTR l
ENCL g SIZE:
TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response NOTES:
05000387 G RECIPIENT ID CODE/NAME PD1-2 PD INTERNAL: ACRS AEO.
ILE CE NRR DRPM/PECB NUDOCS-ABSTRACT OGC/HDS2 EXTERNAL LITCO BRYCE P J H
NRC PDR NOTES:
COPIES LTTR ENCL
1
2
1
1
1
1
1
1
1
1 RECIPIENT ID CODE/NAME NERSES,V AEOD/SPD/RAB DEDRO NRR/DRCH/HHFB NRR/DRPM/PERB OE DIR RGN1 FILE
NOAC NUDOCS FULLTEXT COPIES LTTR ENCL
1
1
1
1
1
1
1
1
1
N NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)
ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:
LTTR
ENCL
January 7,
1998 Mr. Robert Senior Vice President - Nuclear Pennsylvania Power 5 Light Company 2 North Ninth Street Allentown, Pennsylvania 18101 SUBJECT'NSPECTION NOS. 387;388/97-04-REPLY
Dear Mr. Byram:
This letter refers to your December 22, 1997, correspondence, in response to our August 5, 1997, letter.
Thank you for the information documented in your letter.
These actions willbe examined during a future inspection of your licensed program.
Your cooperation with us is appreciated.
Sincerely, Clifford J.
Anderson, Chief Project Branch No. 4 Division of Reactor Projects Docket Nos.
50-387;50-388 Commonwealth of Pen 980i220i37 980i07 PDR ADQCK 05000387
PDR llllllllllllllllllllllllllllllllllllllll CC:
G. T. Jones, Vice President - Nuclear Operations G. Kuczynski, General Manager J. M. Kenny, Supervisor, Nuclear Licensing G. D. Miller, General Manager - Nuclear Engineering R. R. Wehry, Nuclear Licensing M. M. Urioste, Nuclear Services Manager, General Electric C. D. Lopes, Manager - Nuclea~ Security A. Male, Manager, Nuclear Assessment Services H. D. Woodeshick, Special Assistant to the President J. C. Tilton, III, Allegheny Electric Cooperative, Inc.
nsylvania
Distribution:
Region I Docket Room (with concurrences)
Nuclear Safety Information Center (NSIC)
W. Axelson, DRA (IRs)
P. Swetland, DRP A. Linde, DRP NRC Resident Inspector PUBLIC W. Dean, OEDO C. Poslusny, Project Manager, NRR J. Stolz, PDI-2, NRR Inspection Program Branch, NRR (IPAS)
R. Correia, NRR F. Talbot, NRR DOCDESK DOCUMENT NAME':iBRANCH4'tSUS9704.REP To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enctosure
"E" = Copy with attachment/enctosure
"N" = No copy OFFICE DATE RI/DRP KJenison 01/07/98 RI/DRP CAnderson 01/7
/98 01/
/98 OFFICIAL RECORD COPY 01/
/98 01/
/98