Letter Sequence Meeting |
---|
EPID:L-2021-LRM-0099, Presentation Information for Second Pre-Application Meeting Regarding Use of Framatome Fuel at Callaway Plant (Open) |
|
MONTHYEARML21265A2722021-09-22022 September 2021 Partially Closed Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatomes Gaia Fuel Assemblies in Its Core in Reload Quantities for the Callaway Plant, Unit No. 1 Project stage: Meeting ML21271A6102021-09-24024 September 2021, 28 September 2021 Presentation Information for Second Pre-Application Meeting Regarding Use of Framatome Fuel at Callaway Plant Project stage: Request ML21271A6132021-09-28028 September 2021 Enclosure 2: Callaway Unit 1 Presentation Information for Planned Pre-Application Meeting (Closed Meeting), Non-Proprietary (Redacted) Version for Closed Meeting Project stage: Meeting ML21271A6122021-09-28028 September 2021 Enclosure 1: Callaway Unit 1 Presentation Information for Planned Pre-Application Meeting (Public Meeting) Project stage: Meeting ML21279A2852021-09-30030 September 2021, 6 October 2021 Supplement to Presentation Information for Second Pre-Application Meeting Re Use of Framatome Fuel at Plant Project stage: Request ML21279A2862021-10-0606 October 2021 Supplement to Presentation Information for Second Pre-Application Meeting Re Use of Framatome Fuel at Plant Project stage: Supplement ML21274A0012021-10-14014 October 2021 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML21308A0742021-11-17017 November 2021 Summary of Partially Closed Pre-Application Teleconference with Union Electric Company Regarding Approval to Insert Framatomes Gaia Fuel Assemblies in Its Core in Reload Quantities for Callaway Plant, Unit No. 1 Project stage: Meeting 2021-09-22
[Table View] |
|
---|
Category:Meeting Summary
MONTHYEARML23317A0012024-01-12012 January 2024 Audit Summary Regarding LAR to Clarify Support System Requirements for the Residual Heat Removal and Control Room Air Conditioning System Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 ML22259A1192022-10-12012 October 2022 Summary of Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatome Gaia Fuel Assemblies in Its Core Reload Quantities for Callaway Plant, Unit No. 1 ML22181A0012022-07-22022 July 2022 Summary of June 29, 2022, Public Meeting - Union Electric Company, Dba Ameren Missouri to Discuss Upcoming License Amendment Request to Revise Technical Specifications to Reflect Revised Spent Fuel Pool Criticality Safety Analysis ML22147A0932022-06-0606 June 2022 2021 Annual Assessment Public Meeting Summary ML22089A2292022-04-0606 April 2022 February 28, 2022, Summary of Partially Closed Pre-Application Teleconference with Union Electric Company Regarding Approval to Insert Framatome Gaia Fuel Assemblies in Their Core in Reload Quantities for Callaway Plant, Unit No. 1 ML21308A0742021-11-17017 November 2021 Summary of Partially Closed Pre-Application Teleconference with Union Electric Company Regarding Approval to Insert Framatomes Gaia Fuel Assemblies in Its Core in Reload Quantities for Callaway Plant, Unit No. 1 ML21243A0042021-09-0707 September 2021 Summary of Teleconference Meeting with Union Electric Company Regarding Proposed License Amendment Request to Revise the Emergency Plan ML21216A2002021-08-11011 August 2021 Summary of Public Webinar with Ameren Missouri to Discuss the Nuclear Regulatory Commission 2020 Annual Assessment of Callaway Plant Docket No. 50-483 ML21168A0022021-07-0101 July 2021 Summary of Partially Closed Pre-Application Teleconference with Union Electric Company Regarding Approval to Insert Framatome'S Gaia Fuel Assemblies in Their Core in Reload Quantities for Callaway Plant, Unit No. 1 ML21103A0032021-04-16016 April 2021 Summary of March 15, 2021, Teleconference Meeting with Union Electric Company Regarding Proposed License Amendment Request to Implement Alternative Source ML20280A5632020-10-21021 October 2020 Summary of Teleconference Meeting with Union Electric Company (Dba Ameren Missouri) for Callaway Plant, Unit 1, on Pre-Application for LARs on TSTF-439, TSTF-505, and Title 10 CFR 50.69 Categorization Program (EPID L-2020-LRM-0072 ML20189A1992020-07-13013 July 2020 Summary of (COVID-19) Presubmittal Public Teleconference W/Union Electric Company Postponement of Steam Generator Eddy Current Testing, by One Refueling Outage, for Callaway Plant, Unit No. 1 ML20189A2832020-07-0707 July 2020 Summary of Region IV Annual Assessment Public Meeting ML19268A9772019-10-16016 October 2019 Summary of 9/12/2019 Meeting with Union Electric Company Related to Closure of Generic Letter 2004-02 for Callaway Plant, Unit 1 ML18215A3752018-08-21021 August 2018 Summary of Pre-Submittal Meeting with Union Electric Company to Discuss an Alternate Source Term License Amendment Request ML16243A5132016-09-0101 September 2016 Summary of August 25, 2016, Public Meeting with Wolf Creek Nuclear Operating Corporation and Amerenue Regarding a Proposed Application for a New Technical Specification for the Class 1E Electrical Equipment Air Conditioning System (MF8118 a ML16165A0042016-06-23023 June 2016 Summary of 6/1/2016 Public Meeting with Union Electric Company to Discuss Generic Safety Issue 191 and Callaway Plant Unit 1's Debris Testing Plan ML14281A3652015-02-23023 February 2015 May 2, 2014, Summary of Conference Call Held Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Pertaining to the Callaway Plant, Unit 1, License Renewal Application ML14223A6022014-08-20020 August 2014 Summary of Telephone Conference Call Held on December 18, 2013, Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri) ML14223A5322014-08-20020 August 2014 November 26, 2013, Summary of Telephone Conference Call Held Between Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri) Concerning Requests for Additional Information Pertaining to Callaway, Unit 1, License Renewal A ML14177A5952014-07-0808 July 2014 Summary of Telephone Conference Call Held on February 12, 2014, Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Concerning Requests for Additional Information Pertaining to the Callaway Plant, Un ML14175B4992014-07-0808 July 2014 Summary of Telephone Conference Calls Held on October 2 and 3, 2013, Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Concerning Requests for Additional Information Pertaining to the Callaway Plan ML14169A6372014-07-0303 July 2014 Summary of Telephone Conference Call Held on April 28, 2014, Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri) Pertaining to the Callaway Plant, Unit 1, LRA ML14169A6042014-07-0303 July 2014 April 30, 2014, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Pertaining to the Callaway Plant, Unit 1, License Renewal Application ML14125A1992014-07-0303 July 2014 Summary of Telephone Conference Call Held on April 9, 2014, Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Pertaining to the Callaway Plant, Unit 1, License Renewal Application (Tac. No. ME7708) ML14169A4412014-07-0303 July 2014 Summary of Telephone Conference Call Held on April 21, 2014, Between the U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Pertaining to the Callaway Plant, Unit 1, License Renewal Application (Tac. No. ME7708 ML14121A5532014-06-18018 June 2014 November 25, 2013, Summary of Telephone Conference Call Held Between NRC and Union Electric Co., (Ameren Missouri), Concerning Requests for Additional Information Pertaining to Callaway, Unit 1, License Renewal Application ML14093B3382014-04-14014 April 2014 01/30/2014, Summary of Telephone Conference Call Held Between NRC and Union Electric Co., (Ameren Missouri), Concerning Requests for Additional Information Pertaining to Callaway, Unit 1, License Renewal Application ML14087A2102014-04-0808 April 2014 Summary of 3/25/14 Verbal Relief Telephone Conference, Relief Request I3R-16, Temporary Non-Code Repair of the Train a Component Cooling Water Heat Exchanger to Control ESW Leakage, Third 10-Year Inservice Inspection Interval ML14070A0782014-04-0707 April 2014 02/27/2014 & 03/04/2014, Summary of Telephone Conference Call Held Between Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Pertaining to the Callaway Plant Unit 1, License Renewal Application RAI Set 31 ML14080A5442014-03-31031 March 2014 February 20, 2014, Summary of Meeting Held Between U.S. Nuclear Regulatory Commission Staff and Union Electric Company Representatives to Discuss the Callaway Plant, Unit 1, License Renewal Application ML14035A5752014-03-25025 March 2014 January 28, 2014, Summary of Telephone Conference Call Held Between NRC and Union Electric Company (Ameren Missouri), Pertaining to the Callaway Plant Unit 1, LRA ML13246A3072013-09-0909 September 2013 Memorandum to File - Verbal Authorization of Relief Request PR-07, Testing Frequency for Pumps and Valves, Third 10-year Inservice Testing Interval ML13126A3202013-05-0707 May 2013 Summary of Telephone Conference, Verbal Authorization of Relief Request I3R-14. Proposed Alternative to ASME Code Requirements for Leakage Testing of RPV Head Flange Leakoff Lines, Third 10-Year ISI Interval. ML13067A3162013-04-0101 April 2013 August 23, 2012, Summary of Telephone Conference Call Held Between U.S. Nuclear Regulatory Commission and Union Electric Company (Ameren Missouri), Concerning Requests for Additional Information Pertaining to Callaway Plant, Unit 1, License ML13029A0162013-02-12012 February 2013 Summary of Telephone Conference Call Held on January 22, 2013, Between the U.S. Nuclear Regulatory Commission ML13029A6592013-02-12012 February 2013 Summary of Telephone Conference Call Held on December 6, 2012, Between the NRC and Union Electric Company, Concerning Request for Additional Information Pertaining to the Callaway Plant Unit 1, LRA ML13042A1882013-02-11011 February 2013 01/31/2013 Summary of the Public Meeting to Discuss the Results of the Grand Gulf Nuclear Station License Renewal Inspection IR 05000483/20120092013-01-25025 January 2013 1/17/2013 - Summary of Public Meeting to Discuss the Results of the Callaway Nuclear Plant License Renewal Inspection (05000483-12-009) ML12321A1992012-11-29029 November 2012 9/27/12 - Summary of Telephone Conference Call Held Between the NRC and Union Electric Company (Ameren Missouri), Concerning RAIs Pertaining to the Callaway Plant, Unit 1, License Renewal Application ML12321A1882012-11-20020 November 2012 Summary of Preapplication Meeting with Union Electric Company to Discuss Callaway Plant, Unit 1, License Amendment Request to Change Licensing Basis and Analysis of Integrated Head Assembly Consistent with Regulatory Guide 1.61 Revision 1 ML12262A3112012-10-0202 October 2012 Summary of Telephone Conference Call Held on September 14, 2012, Between NRC and Union Electric Company, Concerning the SAMA RAI for the Callaway Plant, Unit 1, LRA ML12243A3922012-09-18018 September 2012 Meeting Summary with Union Electric Company to Discuss Request for New Technical Specification Related to Class 1E Electrical Equipment Air Conditioning System at Callaway Plant, Unit 1 ML12243A3762012-09-18018 September 2012 8/29/2012 Summary of Preapplication Meeting with Union Electric Company to Discuss Request to Revise Technical Specification 3.7.9, Ultimate Heat Sink SR 3.7.9.1 and 3.7.9.2 at Callaway Plant, Unit 1 ML12244A4292012-09-18018 September 2012 Summary of Telephone Conference Call Held on August 29, 2012, Between the U.S. Nuclear Regulatory Commission and Union Electric Company, Concerning the Request for Additional Information Pertaining to the Callaway Plant, Unit 1, License Ren ML1116002282011-06-21021 June 2011 Summary of Meeting with Union Electric Company to Discuss Callaway Plant, Unit 1's Proposed Request to Adopt Risk-informed, Performance-based Alternative Described in National Fire Protection Association Standard (NFPA) 805 ML1115400922011-06-0303 June 2011 Summary of Annual Performance Assessment Meeting with Union Electric Company to Discuss the Callaway Plant Performance for the NRC Inspection Period Ending December 31, 2010 ML1104001662011-02-22022 February 2011 Summary of Meeting with Union Electric Company to Discuss Licensee'S Planned Responses to Staff Requests for Additional Information Callaway Plant'S Request to Revise TS 3.3.2, ESFAS Instrumentation Functions ML1034701472010-12-16016 December 2010 Summary of Meeting with Union Electric Company to Discuss Licensee'S Planned Responses to Staff Requests for Additional Information Related to Callaway Plant'S Request to Revise TS 3.3.2, ESFAS Instrumentation Functions ML1008804162010-03-31031 March 2010 Meeting Summary of Conference Call with Union Electric Company to Discuss Proposed Application for Relocation of Surveillance Frequencies from Callaway Plant Technical Specifications (Risk-Managed TS Initiative 5b) 2024-01-12
[Table view] |
Text
November 17, 2021 LICENSEE: Union Electric Company FACILITY: Callaway Plant, Unit No. 1
SUBJECT:
SUMMARY
OF OCTOBER 14, 2021, PARTIALLY CLOSED PRE-APPLICATION TELECONFERENCE WITH UNION ELECTRIC COMPANY REGARDING APPROVAL TO INSERT FRAMATOMES GAIA FUEL ASSEMBLIES IN ITS CORE IN RELOAD QUANTITIES FOR CALLAWAY PLANT, UNIT NO. 1 (EPID L-2021-LRM-0099)
On October 14, 2021, an Observation pre-application meeting was held between the U.S.
Nuclear Regulatory Commission (NRC) and representatives of Union Electric Company, dba Ameren Missouri (the licensee). The purpose of the meeting was to discuss, in advance, the licensee's intent to submit a license amendment request (LAR) to allow introduction of reload quantities of Framatomes GAIA fuel in the Callaway Plant, Unit No. 1 (Callaway) core.
Currently, Callaway has four lead assemblies of Framatomes GAIA fuel loaded in the core for Fuel Cycle 25 in non-limiting positions. This meeting for the Callaway Vendor Qualification Program was intended to discuss all the licensing analyses required to support fuel reload transition to a new vendor. A portion of the meeting was closed to public participation because proprietary information was discussed. The meeting notice and agenda, dated September 22, 2021, are available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML21265A272. Enclosed is a list of attendees at the meeting.
During the open session of the meeting, the licensee presented meeting slides, which can be found in ADAMS at Accession No. ML21271A612. The licensee covered some background on Callaway, and discussed the GAIA fuel assembly design description, operating experience with GAIA fuel assemblies, and the analyses that have been performed in support of a transition to GAIA fuel. The licensee summarized NRC approved analysis methods and discussed the technical specifications changes necessary to transition to Framatome fuel in the Callaway core.
The licensee's presentation also included its schedule to submit the LAR on August 31, 2022, which will include the rod ejection analysis (REA).
In the previous meeting held on May 20, 2021, on this application, as stated in the meeting summary dated July 1, 2021 (ADAMS Accession No. ML21168A002), the licensee had stated that they were planning to submit the LAR by March 31, 2022 and provide the REA at a later date as a supplement. The split in the LAR submittal schedule was because the REA incorporates the methodology in Regulatory Guide (RG) 1.236, Pressurized-Water Reactor Control Rod Ejection and Boiling-Water Reactor Control Rod Drop Accidents, dated June 2020 (ADAMS Accession No. ML20055F490), and would not be available by March 31, 2022. The NRC staff expressed concern that this approach may result in non-acceptance of the submittal because of the incomplete information at the time of submission of the LAR.
Based upon earlier feedback, the licensee was planning on delaying its application until the REA was completed. However, this delay would decrease the time allowed for the NRC staffs
review and introduce unnecessary schedule pressure. Given that Framatome was adapting an already approved REA methodology to the new RG 1.236 guidance, the NRC staff indicated that it would be reasonable to describe the REA methodology and acceptance criteria within the application and have the Callaway REA available for audit upon completion. This approach is reasonable because cycle-specific changes in fuel management may necessitate subsequent re-analysis of the rod ejection accident. Hence, the REA available for review as part of this application is a sample analysis, which is intended to illustrate the application of the methodology and guidance in RG 1.236.
If the licensee were to submit this application by March 31, 2022, this approach will provide a longer time period for the NRC staffs review, which may be needed due the expected complexity of this submittal. The licensee plans to request the NRC staff approval of the LAR by September 30, 2023, in order to support implementation of this LAR during Fuel Cycle 27.
The NRC staff asked several clarifying questions on the intent of the planned LAR. It was not clear whether the licensee intends to (1) transition completely from Westinghouse to Framatome fuel or (2) add Framatome as an optional fuel vendor (maintaining Westinghouse as a vendor).
Transitioning from one fuel vendor to another (Option #1) is quite common. While seeking approval to load both fuel vendor products (Option #2) would provide the licensee more flexibility, this approach lacks precedence and may raise unique issues. During the meeting, Framatome clarified that the analysis it is performing would support Option #1. However, the licensee also clarified that its future fuel purchasing decisions have not been finalized. Further discussion of this topic is planned in a future pre-submittal meeting.
During the closed session of the meeting, the licensee discussed and provided details on the proposed changes to Framatomes approved methodologies.
No regulatory decisions were made as a result of this teleconference. No members of the public identified themselves on the teleconference. Public Meeting Feedback forms were not received.
Please direct any inquiries to me at 301-415-8371, or via e-mail to Mahesh.Chawla@nrc.gov
/RA/
Mahesh L. Chawla, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-483
Enclosure:
List of Attendees cc: Listserv
LIST OF ATTENDEES OCTOBER 14, 2021, PARTIALLY CLOSED PRE- APPLICATION TELECONFERENCE WITH UNION ELECTRIC COMPANY CALLAWAY PLANT, UNIT NO. 1 TO DISCUSS APPROVAL TO INSERT FRAMATOMES GAIA FUEL ASSEMBLIES IN ITS CORE IN RELOAD QUANTITIES U.S. Nuclear Regulatory Commission Union Electric Company D. Woodyatt J. Cordz A. Sallman T. Elwood M. Chawla J. Kovar J. Dixon-Herrity J. Little A. Keim S. Meyer A. Rau B. Richardson J. Messina D. Rickard R. Beaton J. Knaup P. Clifford J. Vinyard J. Lehning J. McInvale Framatome J. Adams R. Freeman R. Williamson T. Gardner C. White G. Borza M. Byram K. Segard M. Harris T. Lindquist G. Wissinger P. Reed B. Painter Members of the Public None Introduced Enclosure
Meeting Notice: ML21265A272 Meeting Summary: ML21308A074 *via e-mail OFFICE NRR/DORL/LPL4/PM NRR/DORL/LPL4/LA* NRR/DSS/SNSB/BC* NRR/DSS/SFNB/BC*
NAME MChawla PBlechman SKrepel RLukes DATE 11/2/2021 11/5/2021 11/2/2021 11/3/2021 OFFICE NRR/DRO/IQVB/BC* NRR/DORL/LPL4/BC* NRR/DORL/LPL4/PM*
NAME KKavanagh JDixon-Herrity MChawla DATE 11/2/2021 11/17/2021 11/17/2021