Forwards Wg Counsil Transmitting Updated Procedures for Implementing S&W Proposed Methods for Assuring Resolution to External Source Re Pipe Stress Analysis.Related Correspondence
ML20204F648
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 07/29/1986
From: Wooldridge R
WORSHAM, FORSYTHE, SAMPELS & WOOLRIDGE (FORMERLY
To: Bloch P, Jordan W, Mccollom K
Atomic Safety and Licensing Board Panel
References
CON-#386-170 OL, NUDOCS 8608040263
Download: ML20204F648 (2)


Text

., ,,

    • A AIto % ntitbe m WORSHAM, FORSYTHE, S AMPELS & WOOLDRIDGE THIRTT-TWO HUNDRED.20018RYAN T "dERT*7'w'OOLnR,oOE DAEAs. texas 75201 se - o N EIL O. ANDERSON SPENCCR C. RELYEA RONA,o M.MANSON J. CAN SOMANNAN TC<tRMONEa,.>.7.& AUG -1 N136 OrCou~SEL JOS. IRION WORSH AM TRAviS E. VANDERPOOL EARL A. FOR$YTHE JuOsTM N. JOHNSON a CMARo L. Ao*M S OFFICE OF CELAtiAsy o^v'o c waraa^~ 'c'eco*' cad 2'*> 88o- co" JOHN w. =REvNOLoS 00CKETING & sf avicF~

BRANC R RT M. IS TIMOTH Y A. M ACM ROBERT M. FILLMORE WM. STEPHEN SOYO MARM R. WASEM CHRISTORMER R. MILTEN BERGER ROBERT R. OLevER MARK SCMWART2 RICMAND G. MOORE NANCYE L. BETMUREM CECEL. A J. .Ru N ER JOE A. davis July '.9,1986 ERec N P ET E R SO N WALTER w. WMITE Peter B. Bloch, Esquire Dr. Kenneth A. McCollom Chairman Administrative Judge Atomic Safety and Licensing Board 1107 West Knapp U. S. Nuclear Regulatory Commission Stillwater, Oklahoma 74075 Washington, D. C. 20555 Elizabeth B. Johnson Dr. Walter H. Jordan Oak Ridge National Laboratory Administrative Judge P. O. Box X, Building 3500 881 West Outer Drive Oak Ridge, Tennessee 37830 Oak Ridge, Tennessee 37830 Re: Texas Utilities Electric Company, et al (Comanche Peak Steam Electric Station, Units 1 & 2); Docket Nos. 50-445 and 50 446 () b

Dear Administrative Judges:

Attached, for your information, is a copy of letter dated July 28,1986 from W. G. Counsil to Mr. V. S. Noonan, transmitting copies of the updated procedures for implementing the Stone & Webster Engineering Corporation's (SWEC) proposed methods for assuring resolution to external source issues which relate to pipe stress analysis and pipe support design.

Copies of the updated procedures referred to in the attached correspondence have been sent this date to Ms. Juanita Ellis and Cygna Energy Services, Inc.

Respectfully, 86o8040263 e60729  !,

PDR ADOCK0500g5 / p 7^ ,

Robert A. Wooldrid RAW /kiw Enclosure

cc
Ms. Juanita Ellis i Cygna Energy Services, Inc.

I l cc: Service List

co -

Log # TXX-4933 File # 10068 10010 clo TEXAS UTILITIES GENERATING COMPANY SKYWAY TOWER e 400 NORTH OtJVE STREET. L.B. e t . DAIJ AS. TEXAS 7530 8 July 28, 1986 0'C 0?2?"&'h Director of Nuclear Reactor Regulation Attention: Mr. V. S. Noonan, Director Comanche Peak Project Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 IMPLEMENTATION PROCEDURES FOR STONE & WEBSTER ENGINEERING CORPORATION'S RESOLUTIONS OF GENERIC TECHNICAL ISSUES

REFERENCE:

W. G. Counsil letter TXX-4898 to V. S. Noonan d&ted July 9, 1986.

Dear Mr. Noonan:

Enclosed are 15 copies of the updated procedures for implementing the Stone &

Webster Engineering Corporation's (SWEC) proposed methods for assuring resolution to external source issues which relate to pipe stress analysis and pipe support design.

Texas Utilities Generating Company will continue to apprise you of developments in the pipe stress analysis and pipe support design requalification efforts.

Very truly yours, l NN W. G. Counsil JDS/arh A DEVISION OF TEXAS UTILETTES ELECTRIC COMPANY