ML20069E050

From kanterella
Revision as of 06:40, 29 March 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Responds to IE Bulletin 83-01, Failure of Reactor Trip Breakers (Westinghouse DB-50) to Open on Automatic Trip Signal. Operators Instructed to Rept Reactor Trip Breaker Failure as Significant Event as of 830301
ML20069E050
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 03/04/1983
From: Hurford W
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-SSINS-6820 IEB-83-01, IEB-83-1, LAP-83-58, NUDOCS 8303210367
Download: ML20069E050 (3)