_.

O 5'O 60 96l9/o

. unngMEEDnsanm4EsuSECT r,~TocML W emeinemc M S SAFEGUARDS INFORMATW MNN 300FWs.80>

^

j N N,4

~

~

PLANT /0ECDON CP&L SGI NO.86 /5f (WHEN SEPMATEDm0 MEMO 6uRES Carolino Power & Light Company f4 N(12 TM S N '

Robinson Nucleor Plant I:A8DE000mO1.ED 3581 West Entrance Road

~

Hartsville SC 29550 File: 13020DE gg7g Serial: RNP-RA/96-0194 OCT 2 41996

/_.A935y Mr. Virgil R. Autry, Director Division of Radioactive Waste Management Bureau of Solid and llazardous Waste South Carolina Department of licalth and Environmental Control 8O - N /

2600 Bull Street Columbia, SC 29201 First Sergeant Terry C. Stroud, llazardous Material Coordinator North Carolina State liighway Patrol 512 N. Salisbury St.

Raleigh, NC 27626-0590

11. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 NOTIFICATION OF SPENT FUEL SHIPMENT Gentlemen:

In accordance with 10 CFR 73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by Carolina Power & Light (CP&L) i Company.

1.

Name. Address. and Telenhone Number of Shinner. Carrier. and Receiver a.

Shipper: II. B. Robinson Steam Electric Plant (IIBRSEP), Unit No. 2 Docket No. 50-261 3581 West Entrance Road liartsville, SC 29550 (803) 857-1279/1278 b.

Carrier: CSX Transportation Chief Dispatcher 3019 Warrington Street Jacksonville, FL 32205 (904) 381-2780 I

9611190058 961024

)g PDR ADOCK 05000261 F

PDR "S4FEGUARDS"lNFORMATl0N 1

r 0

fxc i DLD Highway 151 and SC 23 Hortsville SC

=

Mr. Virgil R. Autry First Sergeant Terry C. Stroud Serial: RNP-RA/96-0193 Page 2 of 3 c.

Receiver: Shearon Ilarris Nuclear Power Plant (SilNPP)

Docket No. 50-400 P. O. Box 165 New Ilill, NC 27562 (919) 362-2157 2.

Description of Shipment - Radioactive material in IF-300 series shipping cask (s): Cask ID NO. USA /9001/B()F; s/n IF-303, s/n IF-304.

a.

Cask (s) used this shipment:

IF-303 AND IF-304 b.

Proper Shipping Name: Radioactive Material, Fissile, N.O.S., RQ c.

DOT Ilazard Class: 7 d.

DOT ID No: UN2918 DOT Subtype: Ilighway Route Controlled Quantity e.

f.

Mode of Shipment: Rail g.

Physical Form: Solid 11.

Chemical Form: Plutonium Oxide and Uranium Oxide l

i.

" Exclusive Use Shipment" j.

Radionuclides: Cm-244, Pu-238, Pu-241, Am-241, Pm-240, Pu-239 Ru-106 k.

Original Enrichment:

IF-303 3.43 w/o IF-304 3.42 w/o 1.

Ilazardous Material Quantity:

IF-303

'235 Ts.

Est.

IF-304 235 1s.

Est.

m.

Total Curie Content:

IF-303

.342

+6 Est.

IF-304

.516 H6 Est.

n.

Transport Index:

IF-303 '5.00 Est.

IF-304 5.00 Est.

l o.

Category of Label:

Radioactive Yellow III p.

Type of Reactor:

PWR

3. Route Within the States of North Carolina and South Carolina a.

IIBRSEP, Unit No.2 to McBee, SC: CSX Railroad b.

McBee, SC to llamlet, NC: CSX Railroad c.

Ilamlet, NC to SilNPP: CSX Railroad

Mr. Virgil R. Autry First Sergeant Terry C. Stroud

(

Serial: RNP-RA/96-0193 Page 3 of 3 l

By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment. In accordance with 10 CFR 73.21 and 10 CFR 73.37, the information on the attached is designated as Safeguards Information and shall be protected in accordance with provisions of 10 CFR 73.21.

l Questions regarding this matter may be referred to me at (803) 857-1802.

Very truly yours, L3 M6/

A~

R. M. Krich Manager - Regulatory Affairs l

WMB/kib c:

(1)

U.S. Nuclear Regulatory Commission l

Attn: Ms. Gloria Bennington l

NMSS: SFPO-MS: OWFN-6 F-18 l

11555 Rockville Pike l

Rockville, MD 20852-2738 L

i l

(2) Director, Division of Industrial and Medical Nuclear Safety U.S. Nuclear Regulatory Commission Attn: Dr. Donald A. Cool NMSS:IMNS-MS: 8F5 11555 Rockville Pike Rockville, MD 20852-2738 l

l i

I 1

i

-~

--