LER 81-093/01T-0:on 810615,three Containment Isolation Valves Found Not Closed During Testing.Caused by Valves Not Being Included in FSAR List of Containment Penetrations. Valves Closed
ML20009G056
Person / Time
Site: McGuire Duke Energy icon.png
Issue date: 06/29/1981
From: Nardoci P
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20009G051 List:
References
LER-81-093-01T, LER-81-93-1T, NUDOCS 8108030288
Download: ML20009G056 (1)