ML17298B54030 November 1984Summary Rept on Operability of Shutdown Cooling Sys Relief Valves for Palo Verde Units 1,2 & 3.
ML17338B32720 September 1979LER 79-021/03L-0:on 790821,during Normal Operation,Offgas Monitor 3A Took Step Increase W/No Power Change & hi-hi Trip Light Was On.Caused by Faulty V1 Electrometer Tube,Which Was Replaced.Monitors Will Be Tested MonthlyPower change
ML17338B32817 September 1979LER 79-023/03L-0:on 790823,source Range Monitor Calibr Supplied Rod Block Trip at 1.03E5,exceeding Tech Specs Limit.Caused by Drift & Temp Dependency in Source Range Monitor.Defective Component Not Yet Identified
ML17340A9854 April 1981Monthly Operating Repts for Mar 1981
ML17340B41626 March 1980Updated LER 80-030/03X-1:on 791110,during Scram Testing in Refuel Mode,Substantial Loss of Position Indication Noted for Control Rod Driveline H-9.Caused by Improperly Seated Socket,Suggesting Faulty Electrical pin-socket Alignment
ML17340B41928 March 1980LER 80-011/03L-0:on 800305,while Conducting Steam Line Area Temp Switch Calibr Surveillance,Temp Switch TS 3-261-17B Tripped Above Tech Specs.Caused by Dirt Deposits on Switch Actuation Plunger.Switch Cleaned,Adjusted & Tested
ML17341B2427 May 1982QA Manual.Safe Shutdown
Coatings
Nondestructive Examination
Condition Adverse to Quality
Control of Heavy Loads
Backfit
ML17342A20610 June 1985Revised Rev 8 to Topical QA Rept.Safe Shutdown
Non-Destructive Examination
Fire Barrier
Coatings
Nondestructive Examination
Control of Heavy Loads
Early Warning Fire Detection
Backfit
ML17342B04630 November 1987Monthly Operating Repts for Nov 1987
ML17342B05131 October 1987Corrected Monthly Operating Repts for Oct 1987,consisting of Revised Outage Duration Hours
ML17342B08930 November 1987Corrected Monthly Operating Rept for Nov 1987
ML17342B17131 January 1988Monthly Operating Repts for Jan 1988
ML17342B17230 April 1987Corrected Operating Data Repts for Apr 1987
ML17342B17331 May 1987Corrected Operating Data Repts for May 1987
ML17342B17430 June 1987Corrected Operating Data Repts for June 1987
ML17342B17531 July 1987Corrected Operating Data Repts for Jul 1987
ML17342B17631 August 1987Corrected Operating Data Repts for Aug 1987
ML17342B17730 September 1987Corrected Data Operating Repts for Sept 1987
ML17342B17831 October 1987Corrected Operating Data Repts for Oct 1987
ML17342B17930 November 1987Corrected Operating Data Repts for Nov 1987
ML17342B18031 December 1987Corrected Operating Data Repts for Dec 1987
ML17342B18130 September 1987Corrected Operating Data Rept for Sept 1987
ML17342B18231 October 1987Corrected Operating Data Rept for Oct 1987
ML17342B18330 November 1987Corrected Operating Data Rept for Nov 1987
ML17342B18431 December 1987Corrected Operating Data Rept for Dec 1987
ML17342B28631 March 1988Monthly Operating Repts for Mar 1988
ML17342B28929 February 1988Revised Rept of Unit Shutdowns & Power Reductions for Feb 1988
ML17345A16030 April 1988Monthly Operating Repts for Apr 1988.W/880513 Ltr
ML17345A23810 May 1988Rev 11 to, Topical QA Rept.Safe Shutdown
Fire Barrier
Coatings
Nondestructive Examination
Control of Heavy Loads
Early Warning Fire Detection
Backfit
ML17345A24531 May 1988Monthly Operating Repts for May 1988 for Turkey Point Units 3 & 4 & St Lucie Units 1 & 2.W/880615 LtrStroke time
ML17345A28030 June 1988Monthly Operating Repts for June 1988 for St Lucie & Turkey Points.W/880715 Ltr
ML17345A32431 July 1988Monthly Operating Repts for Jul 1988 for Turkey Point Units 3 & 4
ML17345A32531 July 1988Monthly Operating Repts for Jul 1988 for St Lucie Units 1 & 2
ML17345A38731 August 1988Monthly Operating Repts for Aug 1988 for St Lucie & Turkey Point
ML17345A38831 July 1988Corrected Page to Jul 1988 Monthly Operating Rept for St Lucie Unit 1
ML17345A53331 October 1988Monthly Operating Repts for Oct 1988 for St Lucie Units 1 & 2.W/881115 LtrDownpower
ML17345A58230 November 1988Monthly Operating Repts for Nov 1988 for Turkey Point Units 3 & 4 & St Lucie Units 1 & 2
ML17345A58331 October 1988Corrected Monthly Operating Rept for Oct 1988 for Turkey Point Unit 3
ML17345A68530 April 1989Monthly Operating Repts for Apr 1989 for Turkey Point Units 1 & 2 & St Lucie Units 1 & 2.W/890515 Ltr
ML17345A7249 June 1989Rev 15 to Topical QA Rept.Safe Shutdown
Fire Barrier
Coatings
Nondestructive Examination
Condition Adverse to Quality
Control of Heavy Loads
Early Warning Fire Detection
Backfit
ML17345A75031 May 1989Monthly Operating Repts for May 1989 for Turkey Point Units 3 & 4 & St Lucie Units 1 & 2
ML17345A75330 April 1989Corrected Monthly Operating Rept for Apr 1989 for St Lucie Unit 2
ML17346B07610 June 1985Rev 8 to Topical QA Rept.Safe Shutdown
Non-Destructive Examination
Fire Barrier
Coatings
Nondestructive Examination
Condition Adverse to Quality
Control of Heavy Loads
Early Warning Fire Detection
Backfit
ML17346B17131 July 1985Retran Code Transient Analysis Model Qualification.Anticipated operational occurrence
Fuel cladding
Coast down
ML17347A58731 December 1986Performance Rept,1986. W/870515 LtrBoric Acid
Fitness for Duty
ML17347A66931 December 1987Monthly Operating Repts for Dec 1987
ML17347A69229 February 1988Monthly Operating Repts for Feb 1988
ML17347A71231 January 1988Revised Monthly Operating Repts for Jan 1988
ML17347A79716 June 1988Seismic Hazard Data Prepared for Resolution of USI A-46.Earthquake
ML17347A79816 June 1988Radiological Data Prepared for Resolution of USI A-46.Safe Shutdown Earthquake
Earthquake