ML19211A290: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:NRC FORM 366 (7 77)LICENCEE EVENT REPORT CONTROL BLOCK: l llllllh (PLEASE PRINT OR TYPE A11LREQUIRED INFORMATION) 1 6[oTil Ic I A IE 11 in 11 l@l 010101010101010101010 I@2641111ililll@l Il@7 8 9 LICENSEE CODE le 15 LICENSE NUMBER 23.laCENSE TYPE JO
{{#Wiki_filter:NRC FORM 366 (7 77)
$7 CAT 68.CO.lL l@l0 l5 l0 l0 10 l3 l2 l1 @l 1 l 1 l 2 8l 7l 9 @l 1 2 l 1l 1l. 7 l 9 l@
LICENCEE EVENT REPORT CONTROL BLOCK: l 1
'0 1 5 VRC 7 8 60 6l DOCKET NUMBER 68 69 EVENT OATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lO l2l l Af ter re-calibration of P33-P001A and B during steady state power operation, it lIO lal l was observed that the Drywell-Torus H2 and 02 Analyzers "A zud B" were indicating lo 4lgreater than 4% oxygen concentration. The samples taken by lab instrumentation lo 5 lrevealed that the oxygen concentration was 3%.
l      l    l    l    l lh 6
There was no effect on the environs. l O cl This was a non-repetitive event.
(PLEASE PRINT OR TYPE A11LREQUIRED INFORMATION)
ll O s lJ i_80 7 8 9 E CODE SUSCO E COMPONENT CODE SUSOdE SU E[ O].9_jl SjA h b h lX lh l P ! E I N l E l T l R lh J@ y @
[oTil8 Ic 7          9 I A         IE 11 LICENSEE    CODEin 11 l@l 010101010101010101010 le    15                        LICENSE NUMBER                  23 I@2641111ililll@l
7 8 9 10 11 12 13 18 19 20_SEQUENTI AL OCCUR R E NCE RiPORT REVISION LE R 'RO EVENT YE AR REPORT NO.
                                                                                                                                      .laCENSE TYPE JO I
CODE TYPE NO.h REl7l9[--J 0 l 9 l7 l Ml0 3ll Lll_][ 0_j yu_ 21 22 23 24 26 27 28 29 JD 31 32 K N AC ON ON PLA T E HOURS SB IT FO B.SUPPLIER MAN FACTURER l El@lZ l@
                                                                                                                                                                $7 CAT 68 l@
l Z l@W@0l0l0l0lW@Nl@lNl@lXl9l9l9l@
CO.
33 34 35 36 3/40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i O l The cause of the occurrence has been attributed to air inlerkage to the annlyzers li i j causing them to observe a higher than actual reading.
0 1 5 VRC      lL   l@l0 l5 l0DOCKET          l0 10           l3 l2 l1 @l   68 1 l 1EVENT 69 l 2 OATE8l 7l 9 74@l 1 2REPORT75 l 1l 1l. 7 l 980l@
The Eines were tested and l, 7 lall identified leaks repaired.The analyzers were re-calitrated and returned li 3 lto service.
DATE 7       8                     60           6l                         NUMBER EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lO l2l l Af ter re-calibration of P33-P001A and B during steady state power operation, it                                                                                       l IO lal l was observed that the Drywell-Torus H2 and 02 Analyzers "A zud B" were indicating                                                                                       l o 4      l greater than 4% oxygen concentration. The samples taken by lab instrumentation                                                                               l o 5 l          revealed that the oxygen concentration was 3%.                                                 There was no effect on the environs. l O c      l This was a non-repetitive event.                                                                                                                                 l O   s l                                                            J  i  _
ll1 4 7 8 9 80 ST S% POWER OTHER STATUS IS O RY DISQVERY DESCRIPTION l1 l51lE @
l 80 7       8 9 E               CODE         SUSCO E                   COMPONENT CODE                 SUSOdE           SU     E
0l 9 l 8l@l NAll B l@lObservation lACTIVITY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCA10N QF RELEASE NAllNel] @ [_Zj@l 1 6 7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBE R TYPE DESCRIPTION W 10 l 0 l 0 l@l Z l@l NA''' PERSONNEL INJU IES mSCR P1,0~8 1592 236 NUM ER NAl10l0l0l@l1 a 7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY TYPE DESCRIPil0N b [Z_j@lNAl7 tl 9 to 80"'''o'ESCniPriON@
[ O].9_j                          l SjA h b h lX lh l P ! E I N l E l T l R lh J@ y @
7 91217 0 3/4,l'*NnC usE ONtv iSSu@lNAlllllllllll;2 o 7 8 9 10 68 69 80 E NAME OF PREPARER PHONE**
9                                                                                      18          19              20 7       8                                   10           11               12             13
1-NARRATIVE REPORT Georgia Power Company' Plant E.I. llatch Baxley, Georgia Reportable Occurrence Report No. 50-321/1979-097 Af ter re-calibration of P33-P001A and B during steady state power operation analyzers "A and B" at 98% power, J t was observed that the drywell-torus H 022 were indicating greater than 4% oxygen concentration. Actual drywell samples revealed the oxygen concentration was 3%.
_                                                SEQUENTI AL                     OCCUR R E NCE         RiPORT                   REVISION EVENT YE AR                                   REPORT NO.                         CODE               TYPE                     NO.
There was no affect on the environs. This was a non-repetitive event. The cause of the occurrence has been attributed to air inleakage to the analyzers causing them to observe a higher than actual reading. The lines were isolated and pressurized, several leaks in the panel were found and repaired. The analyzers were re-calibrated and returned to service. This problem is only applicable to Unit I because the Unit II drywell is. not inerted. The analyzers are not utilized on any other safety related system on either unit.
LE R 'RO h RE  yu
1592 237-e}}
_ 21 l7l9 22
[--J 23                  24 0 l 9 l7 l 26 M
27 l0 3l 28       29 l Ll JD l_]
31
[ 0_j 32 K N AC ON                 ON PLA T               E                         HOURS           SB IT           FO       B. SUPPLIER           MAN FACTURER l33El@lZ   34 l@           l35Z l@           W@
36                  3/
0l0l0l0l 40 W@
41              42 Nl@             lNl@
43 lXl9l9l9l@
44             47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i O l The cause of the occurrence has been attributed to air inlerkage to the annlyzers                                                                                     l i i     j     causing them to observe a higher than actual reading.                                                       The Eines were tested and                       l
    , 7 l          all identified leaks                           repaired.             The analyzers were re-calitrated and returned                                           l i 3 l          to service.                                                                                                                                                 l 1 4                                                                                                                                                                         l 7     8 9                                                                                                                                                                   80 ST     S           % POWER                         OTHER STATUS                   IS O RY                           DISQVERY DESCRIPTION NA                                        Observation l1 l51lE @                     0l 9 l 8l@l                                                 l    l B l@l                                                                      l ACTIVITY CO TENT RELEASED OF RELE ASE                           AMOUNT OF ACTIVITY                                                       LOCA10N QF RELEASE 7
1 6 8 9
            ] @ [_Zj@l       10           11 NA 44 l          l 45 Ne 80 l
PERSONNEL EXPOSURES NUMBE R             TYPE           DESCRIPTION NA W 10 l 0 l 0 l@l Z l@l
            ' PERSONNEL INJU IES NUM ER              mSCR P1,0~8                                                                                             1592 236 7
1 a 8 9 10l0l0l@l        11     12 NA 80 l
LOSS OF OR DAMAGE TO FACILITY TYPE       DESCRIPil0N b [Z_j@l                                                                                            NA                                                                        l 7      tl 9             to                                                                                                                                                 80 iSSu
                    "'''o'ESCniPriON@                                                                     7 91217 0 3/4,                                   NnC usE ONtv 2 o              @l                                                                              NA                                        l        llllll        lllll; 7       8 9             10                                                                                                                   68 69                         80 E NAME OF PREPARER PHONE
 
1 NARRATIVE REPORT Georgia Power Company' Plant E. I. llatch Baxley, Georgia Reportable Occurrence Report No. 50-321/1979-097 Af ter re-calibration of P33-P001A and B during steady state power operation at 98% power, J t was observed that the drywell-torus H 022 analyzers "A and B" were indicating greater than 4% oxygen concentration. Actual drywell samples revealed the oxygen concentration was 3%. There was no affect on the environs. This was a non-repetitive event. The cause of the occurrence has been attributed to air inleakage to the analyzers causing them to observe a higher than actual reading. The lines were isolated and pressurized, several leaks in the panel were found and repaired. The analyzers were re-calibrated and returned to service. This problem is only applicable to Unit I because the Unit II drywell is. not inerted. The analyzers are not utilized on any other safety related system on either unit.
1592 237 e}}

Latest revision as of 04:57, 2 February 2020

LER 79-097/03L-0:on 791128,after Recalibr of P33-P001A & B During Steady State Power Operation,Drywell Torus Dihydrogen & Dioxide Analyzers a & B Indicated More than 4% Oxygen Concentration.Caused by Leakage of Air Into Analyzer
ML19211A290
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 12/11/1979
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19211A280 List:
References
LER-79-097-03L-01, LER-79-97-3L-1, NUDOCS 7912170316
Download: ML19211A290 (2)


Text

NRC FORM 366 (7 77)

LICENCEE EVENT REPORT CONTROL BLOCK: l 1

l l l l l lh 6

(PLEASE PRINT OR TYPE A11LREQUIRED INFORMATION)

[oTil8 Ic 7 9 I A IE 11 LICENSEE CODEin 11 l@l 010101010101010101010 le 15 LICENSE NUMBER 23 I@2641111ililll@l

.laCENSE TYPE JO I

$7 CAT 68 l@

CO.

0 1 5 VRC lL l@l0 l5 l0DOCKET l0 10 l3 l2 l1 @l 68 1 l 1EVENT 69 l 2 OATE8l 7l 9 74@l 1 2REPORT75 l 1l 1l. 7 l 980l@

DATE 7 8 60 6l NUMBER EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lO l2l l Af ter re-calibration of P33-P001A and B during steady state power operation, it l IO lal l was observed that the Drywell-Torus H2 and 02 Analyzers "A zud B" were indicating l o 4 l greater than 4% oxygen concentration. The samples taken by lab instrumentation l o 5 l revealed that the oxygen concentration was 3%. There was no effect on the environs. l O c l This was a non-repetitive event. l O s l J i _

l 80 7 8 9 E CODE SUSCO E COMPONENT CODE SUSOdE SU E

[ O].9_j l SjA h b h lX lh l P ! E I N l E l T l R lh J@ y @

9 18 19 20 7 8 10 11 12 13

_ SEQUENTI AL OCCUR R E NCE RiPORT REVISION EVENT YE AR REPORT NO. CODE TYPE NO.

LE R 'RO h RE yu

_ 21 l7l9 22

[--J 23 24 0 l 9 l7 l 26 M

27 l0 3l 28 29 l Ll JD l_]

31

[ 0_j 32 K N AC ON ON PLA T E HOURS SB IT FO B. SUPPLIER MAN FACTURER l33El@lZ 34 l@ l35Z l@ W@

36 3/

0l0l0l0l 40 W@

41 42 Nl@ lNl@

43 lXl9l9l9l@

44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i O l The cause of the occurrence has been attributed to air inlerkage to the annlyzers l i i j causing them to observe a higher than actual reading. The Eines were tested and l

, 7 l all identified leaks repaired. The analyzers were re-calitrated and returned l i 3 l to service. l 1 4 l 7 8 9 80 ST S  % POWER OTHER STATUS IS O RY DISQVERY DESCRIPTION NA Observation l1 l51lE @ 0l 9 l 8l@l l l B l@l l ACTIVITY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCA10N QF RELEASE 7

1 6 8 9

] @ [_Zj@l 10 11 NA 44 l l 45 Ne 80 l

PERSONNEL EXPOSURES NUMBE R TYPE DESCRIPTION NA W 10 l 0 l 0 l@l Z l@l

' PERSONNEL INJU IES NUM ER mSCR P1,0~8 1592 236 7

1 a 8 9 10l0l0l@l 11 12 NA 80 l

LOSS OF OR DAMAGE TO FACILITY TYPE DESCRIPil0N b [Z_j@l NA l 7 tl 9 to 80 iSSu

"o'ESCniPriON@ 7 91217 0 3/4, NnC usE ONtv 2 o @l NA l llllll lllll; 7 8 9 10 68 69 80 E NAME OF PREPARER PHONE

1 NARRATIVE REPORT Georgia Power Company' Plant E. I. llatch Baxley, Georgia Reportable Occurrence Report No. 50-321/1979-097 Af ter re-calibration of P33-P001A and B during steady state power operation at 98% power, J t was observed that the drywell-torus H 022 analyzers "A and B" were indicating greater than 4% oxygen concentration. Actual drywell samples revealed the oxygen concentration was 3%. There was no affect on the environs. This was a non-repetitive event. The cause of the occurrence has been attributed to air inleakage to the analyzers causing them to observe a higher than actual reading. The lines were isolated and pressurized, several leaks in the panel were found and repaired. The analyzers were re-calibrated and returned to service. This problem is only applicable to Unit I because the Unit II drywell is. not inerted. The analyzers are not utilized on any other safety related system on either unit.