IR 05000219/1986040: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Adams
{{Adams
| number = ML20203Q184
| number = ML20210U621
| issue date = 05/01/1986
| issue date = 01/30/1987
| title = Meeting Rept 50-219/86-40 on 860401.Major Areas Discussed: Status of Current Piping Reverification Program.Viewgraphs & List of Meeting Attendees Encl
| title = Insp Rept 50-219/86-40 on 861209-16.No Violation Noted.Major Areas Inspected:Observations of Ultrasonic Testing (UT) in Progress,Review of Video Tape of Licensee Visual Insp & Review of Ultrasonic Thickness Measurement Results
| author name = Durr J, Manoly K, Wiggins J
| author name = Kaplan H, Mcbrearty R, Strosnider J
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
| author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
| addressee name =  
| addressee name =  
Line 10: Line 10:
| license number =  
| license number =  
| contact person =  
| contact person =  
| document report number = 50-219-86-40-MM, IEB-79-02, IEB-79-14, IEB-79-2, NUDOCS 8605090094
| document report number = 50-219-86-40, NUDOCS 8702180528
| package number = ML20203Q178
| package number = ML20210U594
| document type = INSPECTION REPORT, NRC-GENERATED, INSPECTION REPORT, UTILITY, TEXT-INSPECTION & AUDIT & I&E CIRCULARS
| document type = INSPECTION REPORT, NRC-GENERATED, INSPECTION REPORT, UTILITY, TEXT-INSPECTION & AUDIT & I&E CIRCULARS
| page count = 23
| page count = 6
}}
}}


Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:
{{#Wiki_filter:. _ = __-
.
U.S. NUCLEAR REGULATORY COMMISSION
 
==REGION I==
Report N /86-40 Docket N License No. DPR-16 Licensee: GPU Nuclear Corporation P. O. Box 388 Forked River, NJ 08731    1 Facility Name: Oyster Creek Nuclear Generating Station Inspection At: Forked River, New Jersey and Reading, Pennsylvania Inspection Conducted: December 9-16, 1986 Inspectors:  OM  27 / 9P7 R.A.McBrearty,ReactorEyneer  g datd 0 h'  27 /9P7
,
H.' K plan, $ actor Engineer  / / dats Approved by: e A 1  / JJ 87
  /J/. R. Strosnider, Chief, Materials &  da'te U Processes Section Inspection Summary: Inspection on December 9-16, 1986 (Report No.50-219/
86-40)
i Areas Inspected: A routine, unannounced inspection was conducted by two regional based inspectors of activities 4.ssociated with drywell wall corrosio The inspection included observations of UT in progress, review of the video tape of the licensee's visual inspection, review of ultrasonic thickness measurement results and the review of core sample analyses done at the GPU laboratory at Reading, P Results: No violations were identified. Ultrasonic testing and analyses of core samples removed from the drywell appeared to be providing necessary infor-
; mation for evaluation of the drywell corrosion proble %fz
 
]%h h  z
  , , _ . _  _ _ . - . _ _ --
 
.
.
DETAILS Persons Contacted GPU Nuclear Corporation (GPUN)
M. Algair, NDE Level III
*T. Corrie, QC Manager - Oyster Creek J. Catellesse, Technician
*J. DeBlasio, Manager, Plant Engineering
*P. Fiedler, Vice President, Oyster Creek S. Fuller, OPS QA Manager
** Jeitner, Supervisor, Materials Engineering Laboratory
*J. Martin, Tech Functions Field Engineer
*M. Radvansky, Manager, Tech Functions, Oyster Creek D. Rauft, Manager, Plant Engineering
*J. Rogers, Site Licensing
*G. Sevak, MC&F Production Project Engineer
*R. Smith, Plant Engineering T. Snider, Manager, MC&F Production J. Sullivan, Jr., Plant Operations Director
*R. Furner, QC Supervisor General Electric Company R. Joffe, Project Manager, UT Level III U.S. Nuclear Regulatory Commission
* Bateman, Senior Resident Inspector
*J. Wechselberger, Resident Inspector
'
* Denotes those present at the exit meeting on [[Exit meeting date::December 11, 1986]].
** Denotes those present at the exit meeting on [[Exit meeting date::December 16, 1986]]. Drywell Wall Thinning Ultrasonic Measurements During the current outage, the licensee detected thinning of the outside surface of the drywell wall where the wall is cushioned by a layer of sand. The original thickness of the drywell wall in this area was specified as 1.154". A sampling plan to determine the extent of thinning was developed by the licensee beginning with two ultrasonic thickness readings in each vent pipe bay. This initial sample was expanded to four measurements in each bay, and then, for readings equal to or less than 0.900" the scope was further expanded to a 7"x7" grid over which measurements were made on 1" center Nine 7"x7" patches were measured in various bays. Additional grid pattern readings were made in areas of two bays where no thin wall
 
. .
 
measurements were originally reported. A trench was cut in the concrete in bay 5 and in bay 17 to facilitate thickness measurements at the lower level where the sand was expected to be wet. The trench in bay 17 measured 18" wide x 39" deep from the top of the curb to 15" below floor level. A total of 329 measurements in bay 5 were made over a 6"x46" grid on 1" centers. The bay 17 measurements were made over a 6"x35" grid with a total of 252 readings on 1" center The results show one reading of 0.889", and the remaining readings greater than 0.900". The majority of the bay 17 readings were 1" or greater. Approximately 7% (23 readings) of the bay 5 readings fell below 0.900" with approximately 5% (15 readings) of the readings falling below 0.700". The low readings (less than 0.900") were scattered throughout the grid with no clustering of thin reading All readings on the 7"x7" grids equal to or less than 0.700" were re-examined with A-scan equipment to more clearly identify the cause of the low readings. Based on the re-examinations the low readings were attributed to laminar type reflectors which resulted in the low thickness readings made using the D-meter. The laminar type reflec-tors were identified in approximately five bays. A core sample which was removed from the wall in bay 5 (at location "A") confirmed the presence of non-metallic inclusions at depths coincident with the ultrasonic readings made at that location. An angle beam examination using a WSY-70 transducer was performed to distinguish between inclu-sions and thinned areas thereby providing information regarding the true condition of the wall. Additionally, welds in three bays were examined for the presence of cracking. In the absence of inclusions, the D-meter thickness measurements agreed with the angle beam results in areas exhibiting corrosion, and the welds were found to be free of indication Core samples were removed from the drywell wall at locations which were selected by the Technical Functions Group to include areas of suspected corrosion, laminations or inclusions, and also areas where the ultrasonic measurements indicated full wall thicknes Core locations were a minimum of 2" from a weld and 6" from any other core location. Samples of the sand exposed by core removal were taken for analysis. Micrometer measurements of removed cores were compared with ultrasonic measurements made prior to removal and confirmed the validity of the ultrasonic reading Personnel from the EPRI NDE Center at Charlotte, North Carolina performed UT scans independent of the licensee's effort and arrived at the same conclusions as the licensee regarding thinning and laminar type reflectors. The EPRI personnel were advised of the suspect area locations, but did not have access to the licensee's results at the time of their inspectio The licensee contracted the General Electric Company to perform an ultrasonic baseline examination of selected degraded areas of the drywell wall using the Ultra Image III System, with the intent to monitor the areas in the future for further degradatio .. .
 
- .
4 Visual Inspection A limited visual inspection using a small video camera was made by the licensee of the drywell wall outside surface in the area of the removed cores, and of the sand condition in those areas. The camera was inserted through the opening left by the core sample, and into the depression remaining from the removal of sand samples. Where poss-ible the adjacent drywell wall outside rurface was also inspecte The visual inspection confirmed, to the extent possible, the UT results regarding wall degradation and provide qualitative informa-tion regarding the relationship between the sand condition and the degree of wall degradation which was observe c. Metallurgical And Chemical Analyses The inspectors reviewed the results of the licensee's metallurgical and chemical analysis of the drywell core sample and sand sample at the GPU laboratory in Reading, PA on December 16, 1986. The licensee presented preliminary results of their chemical analysis of the deposit found on the corroded surface of the core samples. Signifi-cant amounts of chlorine and lead were detected in some of the area The former evidently originated from the wet sand and the latter from the painted surfaces of the drywell. Because the licensee had not yet determined the metallurgical structure of the core samples, the inspector requested that a micro sample be prepared from a core sample exhibiting the worst corrosio The core sample from which the microsample was prepared was identified as 19C. Microscopic examination revealed a well refined structure (Grain Size #7-#8) consisting of pearlite and ferrit The structure is typical of SA 212 Gr B steel, the reported material specification, made to a fine grain practice. No metallurgical anomalies were observed at or away from the corroded surfac The corrosion appeared to be general corrosion with minor pitting ranging between
.001 .003". The inclusions were found to be minute and well distributed. The inspector examined a microsample from core sample 15A which contained segregated stringers of inclusions which were believed to be responsible for the ultrasonic indications in the initial test-ing of the drywell . Figure 1 is a photomicrograph showing these inclusions magnified 100 times. The inclusions appear to be alumina
, oxides. Physical measurements of the inclusions in the core sample correlated well with ultrasonic measurements of the locations
'
of the inclusions thus supporting the hypothesis that the inclusions were the cause of the very low thickness measurements made using the D-mete Based on the inspectors' observation, review of licensee documenta-tion, and discussions at the Reading, PA laboratory the inspectors concluded that the licensee was developing reliable data regarding l
l l
 
.
.
 
the extent and nature of the drywell thinning.and developing an a:ceptable base line for reference in possible future inspection Additionally, the inspector was satisfied that the presence of inclu-sion or other laminar type reflectors resulted in the D-meter low reading .0 Exit Interview The inspector met with licensee representatives (denoted in paragraph 1)
at the conclusion of the onsite inspection on December 11, 1986 and the Reading laboratory on December 16, 1986. The inspector summarized the purpose and the scope of the inspection and the findings. At no time during this inspection was written material provided by the inspector to the license _
. . .
A
      <
    .
        -
          .
  . . .
    ..
    .
  ,.R......, . .
,
    .
      ...,>.;.... .
        -
  -        -
      ~ ... .. . . , . .
        -
        -  ~ ..
  .
    . .:.a ~ 'n, w, '-~ %s ' s. . .e.es,, y
        . . .
        .st*
        .
        -* a ; =  .
  . INCLUSIONS
          -
    . -  --
  ..      ...
    -
        . . . . ..
  .-      .    -
  '
      ,, .
          '~
  .. ..  .    ,
ww:4i.' :..-    , ,ww .  ~ , ~ + -
i ~m a
          ,
          .w l 14i,,, .;.,M+
    .
s.g-- * %A -
  .
  -
      ... 4 -  - -1 .  =a <.., ,1 y .,;4 '' .~.,
    .
    - -
      ~-
x,
      .-  ,,,
          .zn'+ .-
      .
hs  =      *
m o,
CORE SAMPLE 15A  100X FIGURE 1 - shows inclusions believed to be responsible for ultrasonic indication Inclusions appear to be alumna oxide . _ .
.- -
  -.-_ _  .. -_- __._
}}
}}

Latest revision as of 10:42, 2 December 2021

Insp Rept 50-219/86-40 on 861209-16.No Violation Noted.Major Areas Inspected:Observations of Ultrasonic Testing (UT) in Progress,Review of Video Tape of Licensee Visual Insp & Review of Ultrasonic Thickness Measurement Results
ML20210U621
Person / Time
Site: Oyster Creek
Issue date: 01/30/1987
From: Kaplan H, Mcbrearty R, Strosnider J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20210U594 List:
References
50-219-86-40, NUDOCS 8702180528
Download: ML20210U621 (6)


Text

. _ = __-

.

U.S. NUCLEAR REGULATORY COMMISSION

REGION I

Report N /86-40 Docket N License No. DPR-16 Licensee: GPU Nuclear Corporation P. O. Box 388 Forked River, NJ 08731 1 Facility Name: Oyster Creek Nuclear Generating Station Inspection At: Forked River, New Jersey and Reading, Pennsylvania Inspection Conducted: December 9-16, 1986 Inspectors: OM 27 / 9P7 R.A.McBrearty,ReactorEyneer g datd 0 h' 27 /9P7

,

H.' K plan, $ actor Engineer / / dats Approved by: e A 1 / JJ 87

/J/. R. Strosnider, Chief, Materials & da'te U Processes Section Inspection Summary: Inspection on December 9-16, 1986 (Report No.50-219/

86-40)

i Areas Inspected: A routine, unannounced inspection was conducted by two regional based inspectors of activities 4.ssociated with drywell wall corrosio The inspection included observations of UT in progress, review of the video tape of the licensee's visual inspection, review of ultrasonic thickness measurement results and the review of core sample analyses done at the GPU laboratory at Reading, P Results: No violations were identified. Ultrasonic testing and analyses of core samples removed from the drywell appeared to be providing necessary infor-

mation for evaluation of the drywell corrosion proble %fz

]%h h z

, , _ . _ _ _ . - . _ _ --

.

.

DETAILS Persons Contacted GPU Nuclear Corporation (GPUN)

M. Algair, NDE Level III

  • T. Corrie, QC Manager - Oyster Creek J. Catellesse, Technician
  • J. DeBlasio, Manager, Plant Engineering
  • P. Fiedler, Vice President, Oyster Creek S. Fuller, OPS QA Manager
    • Jeitner, Supervisor, Materials Engineering Laboratory
  • J. Martin, Tech Functions Field Engineer
  • M. Radvansky, Manager, Tech Functions, Oyster Creek D. Rauft, Manager, Plant Engineering
  • J. Rogers, Site Licensing
  • G. Sevak, MC&F Production Project Engineer
  • R. Smith, Plant Engineering T. Snider, Manager, MC&F Production J. Sullivan, Jr., Plant Operations Director
  • R. Furner, QC Supervisor General Electric Company R. Joffe, Project Manager, UT Level III U.S. Nuclear Regulatory Commission
  • Bateman, Senior Resident Inspector
  • J. Wechselberger, Resident Inspector

'

    • Denotes those present at the exit meeting on December 16, 1986. Drywell Wall Thinning Ultrasonic Measurements During the current outage, the licensee detected thinning of the outside surface of the drywell wall where the wall is cushioned by a layer of sand. The original thickness of the drywell wall in this area was specified as 1.154". A sampling plan to determine the extent of thinning was developed by the licensee beginning with two ultrasonic thickness readings in each vent pipe bay. This initial sample was expanded to four measurements in each bay, and then, for readings equal to or less than 0.900" the scope was further expanded to a 7"x7" grid over which measurements were made on 1" center Nine 7"x7" patches were measured in various bays. Additional grid pattern readings were made in areas of two bays where no thin wall

. .

measurements were originally reported. A trench was cut in the concrete in bay 5 and in bay 17 to facilitate thickness measurements at the lower level where the sand was expected to be wet. The trench in bay 17 measured 18" wide x 39" deep from the top of the curb to 15" below floor level. A total of 329 measurements in bay 5 were made over a 6"x46" grid on 1" centers. The bay 17 measurements were made over a 6"x35" grid with a total of 252 readings on 1" center The results show one reading of 0.889", and the remaining readings greater than 0.900". The majority of the bay 17 readings were 1" or greater. Approximately 7% (23 readings) of the bay 5 readings fell below 0.900" with approximately 5% (15 readings) of the readings falling below 0.700". The low readings (less than 0.900") were scattered throughout the grid with no clustering of thin reading All readings on the 7"x7" grids equal to or less than 0.700" were re-examined with A-scan equipment to more clearly identify the cause of the low readings. Based on the re-examinations the low readings were attributed to laminar type reflectors which resulted in the low thickness readings made using the D-meter. The laminar type reflec-tors were identified in approximately five bays. A core sample which was removed from the wall in bay 5 (at location "A") confirmed the presence of non-metallic inclusions at depths coincident with the ultrasonic readings made at that location. An angle beam examination using a WSY-70 transducer was performed to distinguish between inclu-sions and thinned areas thereby providing information regarding the true condition of the wall. Additionally, welds in three bays were examined for the presence of cracking. In the absence of inclusions, the D-meter thickness measurements agreed with the angle beam results in areas exhibiting corrosion, and the welds were found to be free of indication Core samples were removed from the drywell wall at locations which were selected by the Technical Functions Group to include areas of suspected corrosion, laminations or inclusions, and also areas where the ultrasonic measurements indicated full wall thicknes Core locations were a minimum of 2" from a weld and 6" from any other core location. Samples of the sand exposed by core removal were taken for analysis. Micrometer measurements of removed cores were compared with ultrasonic measurements made prior to removal and confirmed the validity of the ultrasonic reading Personnel from the EPRI NDE Center at Charlotte, North Carolina performed UT scans independent of the licensee's effort and arrived at the same conclusions as the licensee regarding thinning and laminar type reflectors. The EPRI personnel were advised of the suspect area locations, but did not have access to the licensee's results at the time of their inspectio The licensee contracted the General Electric Company to perform an ultrasonic baseline examination of selected degraded areas of the drywell wall using the Ultra Image III System, with the intent to monitor the areas in the future for further degradatio .. .

- .

4 Visual Inspection A limited visual inspection using a small video camera was made by the licensee of the drywell wall outside surface in the area of the removed cores, and of the sand condition in those areas. The camera was inserted through the opening left by the core sample, and into the depression remaining from the removal of sand samples. Where poss-ible the adjacent drywell wall outside rurface was also inspecte The visual inspection confirmed, to the extent possible, the UT results regarding wall degradation and provide qualitative informa-tion regarding the relationship between the sand condition and the degree of wall degradation which was observe c. Metallurgical And Chemical Analyses The inspectors reviewed the results of the licensee's metallurgical and chemical analysis of the drywell core sample and sand sample at the GPU laboratory in Reading, PA on December 16, 1986. The licensee presented preliminary results of their chemical analysis of the deposit found on the corroded surface of the core samples. Signifi-cant amounts of chlorine and lead were detected in some of the area The former evidently originated from the wet sand and the latter from the painted surfaces of the drywell. Because the licensee had not yet determined the metallurgical structure of the core samples, the inspector requested that a micro sample be prepared from a core sample exhibiting the worst corrosio The core sample from which the microsample was prepared was identified as 19C. Microscopic examination revealed a well refined structure (Grain Size #7-#8) consisting of pearlite and ferrit The structure is typical of SA 212 Gr B steel, the reported material specification, made to a fine grain practice. No metallurgical anomalies were observed at or away from the corroded surfac The corrosion appeared to be general corrosion with minor pitting ranging between

.001 .003". The inclusions were found to be minute and well distributed. The inspector examined a microsample from core sample 15A which contained segregated stringers of inclusions which were believed to be responsible for the ultrasonic indications in the initial test-ing of the drywell . Figure 1 is a photomicrograph showing these inclusions magnified 100 times. The inclusions appear to be alumina

, oxides. Physical measurements of the inclusions in the core sample correlated well with ultrasonic measurements of the locations

'

of the inclusions thus supporting the hypothesis that the inclusions were the cause of the very low thickness measurements made using the D-mete Based on the inspectors' observation, review of licensee documenta-tion, and discussions at the Reading, PA laboratory the inspectors concluded that the licensee was developing reliable data regarding l

l l

.

.

the extent and nature of the drywell thinning.and developing an a:ceptable base line for reference in possible future inspection Additionally, the inspector was satisfied that the presence of inclu-sion or other laminar type reflectors resulted in the D-meter low reading .0 Exit Interview The inspector met with licensee representatives (denoted in paragraph 1)

at the conclusion of the onsite inspection on December 11, 1986 and the Reading laboratory on December 16, 1986. The inspector summarized the purpose and the scope of the inspection and the findings. At no time during this inspection was written material provided by the inspector to the license _

. . .

A

<

.

-

.

. . .

..

.

,.R......, . .

,

.

...,>.;.... .

-

- -

~ ... .. . . , . .

-

- ~ ..

.

. .:.a ~ 'n, w, '-~ %s ' s. . .e.es,, y

. . .

.st*

.

-* a ; = .

. INCLUSIONS

-

. - --

.. ...

-

. . . . ..

.- . -

'

,, .

'~

.. .. . ,

ww:4i.' :..- , ,ww . ~ , ~ + -

i ~m a

,

.w l 14i,,, .;.,M+

.

s.g-- * %A -

.

-

... 4 - - -1 . =a <.., ,1 y .,;4 .~.,

.

- -

~-

x,

.- ,,,

.zn'+ .-

.

hs = *

m o,

CORE SAMPLE 15A 100X FIGURE 1 - shows inclusions believed to be responsible for ultrasonic indication Inclusions appear to be alumna oxide . _ .

.- -

-.-_ _ .. -_- __._