ML20237E449
| ML20237E449 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 06/10/1998 |
| From: | Miller H, Walker T NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | |
| References | |
| EA-98-220, EN-98-047, EN-98-47, NUDOCS 9808310286 | |
| Download: ML20237E449 (1) | |
Text
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
June 10,1998 h
EN 98-047 OFFICE OF ENFORCEMENT NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION Licensee:
GPU Nuclear, Inc. (EA 98-220)
Oyster Creek Nuclear Generating Station Docket No. 50-219 Subiect: PROPOSED IMPOSITION OF civil PENALTY - $55,000 This is to inform the Commission that a Notice of Violation and Proposed imposition of Civil Penalty in the amount of $55,000 will be issued on or about June 15,1998 to GPU Nuclear, Inc. This action is based on a Severity Levelill problem involving inoperability of
. three of five Automatic Depressurization Valves, as well as design errors and apparent qualification concerns that contributed to the inoperability. The two violations are classified in the aggregate at Severity Level 111. Because this was not the first escalated enforcement action within the past two years, the staff considered whether credit was warranted for identification and corrective action. Credit was not warranted for identification because the violations were identified by the NRC. Credit was warranted for corrective actions because GPU Nuclear, incorporated's corrective actions were considered prompt and comprehensive.
It should be noted that the licensee has not been specifically informed of the enforcement action. The schedule of issuance and notification is:
Mailing of Notice June 15,1998 Telephone Notification of Licensee June 15,1998 The State of New Jersey will be notified.
The licensee has thirty days from the date of the Notice in which to respond. Following NRC evaluation of the response, the civil penalties may be remitted, mitigated, or imposed by Order.
' Contacts: H. Miller, RI, (610) 337-5299, T. Walker, RI, (610) 337-5381 Distribution OWFN OWFN TWFN Regional Offices Chairman Jackson EDO OC RI RIV Comm. Dieus DEDR AEOD Ril WCFO Comm. Diaz DEDS OP CTR Rlli Comm. McGaffigan OE NMSS
'SECY OGC IRM Mall OCA NRR OlG NUDOCS PA 01 RES POR IP SP ACRS ClO CFO PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTil VERIFICATION THAT LICENSEE HAS RECEIVED ACTION
,, h
&7 W
b.
\\
9908310286 990610 PDR ISE EN-98-047 pop 1
L
_ _ _