LER 82-041/03L-0:on 820516,during Cold Shutdown,Pipe Clamp Found Removed from Core Spray B Loop Test Line to Torus. Clamp Hold Pipe Restraint 2E21-CS-R106 in Place.Caused by Personnel Error.Clamp Reinstalled
ML20054E438
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 06/03/1982
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20054E433 List:
References
LER-82-041-03L-01, LER-82-41-3L-1, NUDOCS 8206110207
Download: ML20054E438 (2)


LER-2082-041,
Event date:
Report date:
3662082041R00 - NRC Website

text

NRC FORM 3665 U. S. NUCLEAR REGULATORY COMMISSION (7 77) .

LICENSEE EVENT REPORT (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

CONTROL BLOCK: l 1

l l l l l 6

lh j o l 3 l l G l A l E l I l H l 2 [gl 0 l 0 l - l 0 l 0 l 0 l 0 l 0 l- l 0 l 025l@l 4 l1 l 1 l 1 l 1 l@l$7 CAT 14 LICENSE NUMBER 26 LICENSE TYPE JG l

$8 lg 7 8 9 LICENSEE f 90E 15 CON'T lolil

/ 8

"%RC60L'J@l610151 101013161668ei 063 i s EVENT DOCK ET NUVBER 11 l6 DATE l 8 l 2 i@lo leREPORT 74 75 lo l318 DATE 1280l@

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h i o gj l On May 16, 1982, while Unit Two was in cold shutdown a pipe clamp was l o 3 l found removed from the Core Spray "B" Loop Test Line to the Torus by a l g o i,; l Plant Equipment Operator. The subject clamp holds pipe restraint I io m i 2E21-CS-R106 in place. Plant operation was not affected. There were l y a is l l no effects upon public health and safety due to this non-repetitive event. I lo lil I I l O ITl i I

' CSE" '!OTE S eC$5E COMPONENT CODE Su'8ED'E S$$E ITIil 7 8 l S l F l@ [ A_j@ [ C_j @ l S I Ul P l 0 l R l T l@ LX_J@ [Z_j @

9 10 11 12 13 18 19 20

,,_ SEQUE NTI AL OCCURRENCE REPORT REVISION LER RO EVENT YE AR REPORT NO. CODE TYPE N O.

@ ,agoa' L81 al22 t__j l 0 I 4111 24 LcJ 1013I 28 W l' I 30 l.-l 31 IoI 32

_ 21 23 26 21 KEN ACT ON ON PLANT MET D HOURS SB IT FOR b B. St.,PPL1 MAN FACTURER LAl@LZj@ [_Zj@ LZ_J@ l 010I 0l 0i Ly_l@

41 LN_l@ LZ_j@ lZl9l9l9l@

JJ 34 35 36 3/ 40 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h io l The cause of this event was attributed to personnel error since no l l3 li l l Maintenance Request (MR) was generated to remove the clamp initially. l

,, l The clamp was reinstalled and inspected per MR-2-82-2861 by May 18, i iiial 1 1982. l 1: 141 I l 7 8 9 80 ST S  % POWE R OTHE R STATUS dis OV RY DISCOVERY DESCRIPTION I1 l'> l l Gl@ l 01010 l@l NA l lBl@l ODerator observatinn l A TiVITY CONTENT HELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE li 16 l [ Zj @ [Z_j@l NA I l NA l PERSONNEL EXPOS ES NuveeR TYPE DESCRIPTION @

lig l 0l 0l 0l@l Zl@l NA l PERSONNELINJU iES NuveE R DESCRIPTION @

l 7

i n 8 9 10101 Ol@l12 11 NA 80 TYPE DESC PTON 1 9 [Z_j@l NA l 7 H 9 10 80 PUsuciTY Q 8206110207 820603 NRC USE ONLY

  • DESCRIPTION U PDR ADOCK 05000366
r o issuEn@l LNJ S PDR I IIIIIIIIIIIIII F 8 9 10 68 69 80 ;;

NAVE OF PHEPARER R. T. Nix, Supt. of Maintenance pgong. 912-367-7781

LER No.: 50-366/1982-041 Licensee: Georgia Power Company

-Facility: Edwin I. Hatch Docket No.: 50-366 Narrative Report for LER 50-366/1982-041 On May 16, 1982, while Unit Two was in cold shutdown, a pipe clamp was found removed from the "B" Core Spray Loop Test Line to the Torus by a Plant Equipment Operator. The subject clamp holds pipe restraint 2E21-CS-R106 in place. Plant operation was not affected. There were no effects upon public health and safety due to this non-repetitive event.

The cause of this event was attributed'to personnel error since no Maintenance Request (MR) was generated to remove the clamp initially.

The clamp was reinstalled and inspected per MR-2-82-2861 by May 18, 1982. ,

4 l