ML20062D315

From kanterella
Jump to navigation Jump to search
/03L-0 on 781028:at 95% Rated Pwr,Lprm Calibr OD-1 Was Performed,Changing Cmflpd from 0.97 to 1.004.Flow Was Reduced After Which Peak LHGR Was Reduced to 99% of Its Limit.Caused by Inaccurate Base Distrib in Computer
ML20062D315
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 11/13/1978
From: Thomas Greene
GEORGIA POWER CO.
To:
Shared Package
ML20062D313 List:
References
LER-78-090-03L, LER-78-90-3L, NUDOCS 7811210346
Download: ML20062D315 (1)


Text

- - - - . - _- . .

_ l u.

..vuuten HtteUL A 8 0H Y COMMISSION

., y . LICENSEE EVENT REPORT  : i y

COyTnOL Bt.OCK: l l l i

l l l 6

lh iPLEASE t'RINT OR TYPE ALL REQUlitED INFonMATIOtJ)

] la G 9 l A uCENl C lu ICc.3 l ul 1l@l o25 j o l o l o juaNaNuwEn i4 o l o j o j o l o j o j o [@[j l 1 l 1 l t [ 1 l@[

a a ucu.a twE a

[

de w w lg ,(

I 4*T il

] 8 Q l L }@l ol 510101

(,0 (, a o l 312 l 1 t.4I@led1 j o l a f a l t l n l@l 31 il il ,1 yl a l@

oggEET NUWtEH 48 f,

EVENT OA1E 75 FiEPOHT DATE tsJ *i EVEtJT DESCats' TION AtJD PRODAOLE CONSEQUENCES h f.

] [At 95'. of ratOd cower , followina a pre-condit icninn ramp. nn em-1 RPFM calibratien) I b 0

] lwas performed. CMFLPD chanced from o. 97, orior to the calibration, to 1.004, after l '

I i I

@ Ithe calibration. No flow chances or rod mo'vements had been made durino the OD-1. Flev l '

l-

] pas reduced within 5 minutes to correct the oroblem. Following the flow reduction, thol  !:

.' 4 D tocak LHGR was reduced, within 20 ninutos, to aceroxihtelv 99% of its limit. The LUGR I l'

] lindicatiori was in violation of Technical Soecifications, Section 3.11.1.B.' This is a I !I

{ /*sectitive

g. '

occurrence. See LER 78-71 and 78-A6. I SYSTEM 2AUSE CAUSE so COVP. VALVE (

  • CODE CODE SUSCODE COMPONENT CODE s 'SU8 CODE SUCCODE B s I z1 zl@ Lx_J@ l x l@ IJlz I z! I :I zi :l@ ' I zl@ LzJ @

9 to a1 12 18 19 23

_ SEQUENTIAL OCCURRENCE REPnRT gg , EVENT YEAR REVISION REPORT NO. COCE TYPE a; I 7i ei No.

@ ,a(jg.RO L-J l of 91 of 1/l I o l 31 i LI l-l

_ 21 22 23 24 26 27 28 IoI i 23 30 31 32 ACTION FuT u s'E EFFECT SMUTDOWN ATTACHMENT TAKEN ACTIO*J ON PLA*47 METHOO NMO 4 PRIVE COMP. COMPONENT MOURS SUOvtTTED POR*.t >US. . $UPPU E R l MANUFACTURER I x l@34Wh 33 l6Z l h 3 l4Z lh 3/l o l ol 01 O!

3 40 l Nl@

44 IN lh lZl@ lZ l 9l 9l 9lh 47 43 44 47 f

CAUSE DESCfUPTION AND CORRECTIVE ACTIONS h

] l Inaccurate base distribution in the crocess computer resulted in the non-conservative {

'l jl,

]. l calculation cf LT.CRin that recion. The OD-1 (LPF21 Culibration) corrected'the eroblem, I /

- I.

g indicatino the violation. Reduction of flow reduced the LHG2 to within Toch Scoc limits. l l g [k bo further action was necessary.

{ t BI s9 I k

i

' 80 8 STAVUS  % POWER 9 [Cjh l 0l9 l5 l@l OTHER STATUS N/A l Ot3 0 RY lDl@l N/A OfSCOVERY DESCRIPTION h l 1

ACTIVITY CO TENT n i I

{ ELEAsto OF REl.EASEW 8 9 to is AMOUNT @N/Alr!,yl OF ACTIVITY 44 l

46

@l N/A '

LOCATION OF RELEASE @

l >:

PEftSONNEL E XPOSUMES 80 NUVB?R TYps CESCRIPTION - .

D6 I9O ! G I o11I@l 21@l N/A I? IJ l i

PEHSONNEL tNJumES 80 NUYn E R DESCntPTION 'II l

Olofof 4 0 in l@l17 "/7 - - - M' I l . LOOS OF Ort OAU AGE TO F ACILITV

'g 1141 V ' 80 l TvrE OCLCat1 Pleo 4

]l3l@l 5 9 to N/A .

l PUft L ICITY e

t l'gt tf n DL*CetPTIO*4 NHC USE ONLY l l  %

, u u, l  !!!!!!!!!!!! $

a co co s T " ** * " "

FJAtJE OF PitEPAllEf t

  • PttONE:

I

_