{{#Wiki_filter:Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place 111 ER* Bridgman, MI 49106R AE~corn A unit of American Electric Power August 4, 2006 AEP:NRC:6055-10 10 CFR 50.55a Docket No. 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 2 INSERVICE INSPECTION  
{{#Wiki_filter:Indiana Michigan Power INDIANA                                                                             Cook Nuclear Plant MICHIGAN                                                                             One Cook Place Bridgman, MI49106 111     ER*                   J* R                                                AE~corn A unitof American Electric Power August 4, 2006                                                                   AEP:NRC:6055-10 10 CFR 50.55a Docket No.           50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 2 INSERVICE INSPECTION  


==SUMMARY==
==SUMMARY==
REPORT The attachment to this letter provides a copy of the inservice inspection summary report for activities at Donald C. Cook Nuclear Plant Unit 2, National Board (State of Michigan)Number 1 (Mich. M-324232-M), located in Bridgman, Michigan.
REPORT The attachment to this letter provides a copy of the inservice inspection summary report for activities at Donald C. Cook Nuclear Plant Unit 2, National Board (State of Michigan)
The plant is owned by Indiana Michigan Power Company, P.O. Box 60, Fort Wayne, IN, 46801.The Unit 2 commercial service date is July 1, 1978, and the Authorized Code Inspectors during the report period were Mr. A. S. Jimenez and Mr. J. A. Longenberger, both of whom were employed by ABS Group, Inc. of Houston, Texas.The examinations, tests, replacements, repairs performed, conditions observed, and corrective measures taken are summarized in the attached report. Inservice inspection activities were performed in accordance with the rules and requirements of the American Society of Mechanical Engineers' Code, Section XI, 1989 Edition (no Addenda) and 1992 Edition with the 1992 Addenda, as applicable.
Number 1 (Mich. M-324232-M), located in Bridgman, Michigan. The plant is owned by Indiana Michigan Power Company, P.O. Box 60, Fort Wayne, IN, 46801.
There are no new commitments in this letter. Should you have any questions, please contact Ms. Susan D. Simpson, Regulatory Affairs Manager, at (269) 466-2428.Sin~cerqqly, Jose Jensen eSupport Services Vice President  
The Unit 2 commercial service date is July 1, 1978, and the Authorized Code Inspectors during the report period were Mr. A. S. Jimenez and Mr. J. A. Longenberger, both of whom were employed by ABS Group, Inc. of Houston, Texas.
The examinations, tests, replacements, repairs performed, conditions observed, and corrective measures taken are summarized in the attached report. Inservice inspection activities were performed in accordance with the rules and requirements of the American Society of Mechanical Engineers' Code, Section XI, 1989 Edition (no Addenda) and 1992 Edition with the 1992 Addenda, as applicable.
There are no new commitments in this letter. Should you have any questions, please contact Ms. Susan D. Simpson, Regulatory Affairs Manager, at (269) 466-2428.
Sin~cerqqly, JoseeSupport  Jensen Services Vice President


==Attachment:==
==Attachment:==
Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2, 2006, Unit 2 Cycle 16 Refueling Outage.
RV/rdw                                                                                                    AOL,7


Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2, 2006, Unit 2 Cycle 16 Refueling Outage.RV/rdw AOL,7 U. S. Nuclear Regulatory Commission AEP:NRC:6055-10 Page 2 c: R. Aben, DLEG/BCCFS/BD J. L. Caldwell, NRC Region III K. D. Curry, Ft. Wayne AEP, w/o attachment J. T. King, MPSC, w/o attachment MDEQ -WHMD/RPMWS, w/o attachment NRC Resident Inspector P. S. Tam, NRC Washington, DC Attachment to AEP:NRC:6055-10 Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2 2006, Unit 2 Cycle 16 Refueling Outage INSERVICE INSPECTION  
U. S. Nuclear Regulatory Commission               AEP:NRC:6055-10 Page 2 c:     R. Aben, DLEG/BCCFS/BD J. L. Caldwell, NRC Region III K. D. Curry, Ft. Wayne AEP, w/o attachment J. T. King, MPSC, w/o attachment MDEQ - WHMD/RPMWS, w/o attachment NRC Resident Inspector P. S. Tam, NRC Washington, DC
 
Attachment to AEP:NRC:6055-10 Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2 2006, Unit 2 Cycle 16 Refueling Outage
 
INSERVICE INSPECTION  


==SUMMARY==
==SUMMARY==
REPORT FOR THE DONALD C. COOK NUCLEAR PLANT UNIT 2 2006, Unit 2 Cycle 16 REFUELING OUTAGE INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report for Inspection Period From November 10, 2004 to May 5, 2006 Prepared by: Reviewed by: "4 ý eDat I ogram Owner Date: Engineering Programs Supervisor LL 1 2 ijjl o 1 of 82 Total Pages INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report of Inservice Inspections From November 10, 2004 to May 5, 2006 TABLE OF CONTENTS Pages Section 1 Introduction 3 Section 2 NIS-1 Inservice Inspection 4-6 Summary Report Section 3 Abstract of Examinations, Results,.
REPORT FOR THE DONALD C. COOK NUCLEAR PLANT UNIT 2 2006, Unit 2 Cycle 16 REFUELING OUTAGE INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report for Inspection Period From November 10, 2004 to May 5, 2006 Prepared by:     "4 ý   eDat I     ogram Owner                   LL12ijjl o
7-16 And Corrective Actions for Class 1 And Class 2 Components Section 4 System Pressure Tests 17 Section 5 Snubber Tests 18-20 Section 6 ASME Section XI, Article IWE and IWL 21-26 Section 7 ASME Section XI, Steam Generator 27 Eddy Current Examinations Section 8 NIS-2 Repair and Replacement 28-29 Reports Index Section 9 NIS-2 Repair and Replacement 30-82 Reports 2 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 1 INTRODUCTION This report summarizes the Inservice Inspection (ISI) activities performed at the Donald C. Cook Nuclear Plant (CNP) Unit 2, for the period of November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Unit 2 Cycle 16, 2006, Refueling Outage. This is the second and final refueling outage of the Second Inspection Period of the Third Ten-Year Interval.These activities were performed in accordancb with the requirements of the ASME Boiler and Pressure Vessel Code, Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components.
Reviewed by:                                  Date:
As of July 1, 1996, the third ten-year inspection interval began and the applicable code of record for ISI activities became ASME Section XI, 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda for the Containment as applicable.
Engineering Programs Supervisor 1 of 82 Total Pages
The purpose of this report is to satisfy the requirements of IWA-6000 for the submittal of an Inservice Inspection Summary Report at the completion of each refueling outage.Examination and tests conducted since the preceding summary report are included in this report. Repairs and replacements are also included in this report per the requirements of the 1989 Edition of ASME Section XI, IWA-6220.Contents of this report have been reviewed and verified correct with supporting documentation available at the plant for review if required.3 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 2 NIS-1 INSERVICE INSPECTION  
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report of Inservice Inspections From November 10, 2004 to May 5, 2006 TABLE OF CONTENTS Pages Section 1   Introduction                             3 Section 2   NIS-1 Inservice Inspection               4-6 Summary Report Section 3   Abstract of Examinations, Results,.     7-16 And Corrective Actions for Class 1 And Class 2 Components Section 4   System Pressure Tests                   17 Section 5   Snubber Tests                             18-20 Section 6   ASME Section XI, Article IWE and IWL     21-26 Section 7   ASME Section XI, Steam Generator         27 Eddy Current Examinations Section 8   NIS-2 Repair and Replacement             28-29 Reports Index Section 9   NIS-2 Repair and Replacement             30-82 Reports 2
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 1 INTRODUCTION This report summarizes the Inservice Inspection (ISI) activities performed at the Donald C. Cook Nuclear Plant (CNP) Unit 2, for the period of November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Unit 2 Cycle 16, 2006, Refueling Outage. This is the second and final refueling outage of the Second Inspection Period of the Third Ten-Year Interval.
These activities were performed in accordancb with the requirements of the ASME Boiler and Pressure Vessel Code, Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. As of July 1, 1996, the third ten-year inspection interval began and the applicable code of record for ISI activities became ASME Section XI, 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda for the Containment as applicable.
The purpose of this report is to satisfy the requirements of IWA-6000 for the submittal of an Inservice Inspection Summary Report at the completion of each refueling outage.
Examination and tests conducted since the preceding summary report are included in this report. Repairs and replacements are also included in this report per the requirements of the 1989 Edition of ASME Section XI, IWA-6220.
Contents of this report have been reviewed and verified correct with supporting documentation available at the plant for review if required.
3
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 2 NIS-1 INSERVICE INSPECTION  


==SUMMARY==
==SUMMARY==
REPORT Acronyms CCW Component Cooling Water System CS Emergency Core Cooling System CTS Containment Spray System ESW Essential Service Water System'FW Feedwater System MDAFP Motor Driven Auxiliary Feedwater Pump MS Main Steam System NOP Normal Operating Pressure NOT Normal Operating Temperature RCP Reactor Coolant Pump RCS Reactor Coolant System RHR Residual Heat Removal Syktem RWST Refueling Water Storage Tank SI Safety Injection System TDAFP Turbine Driven Auxiliary Feedwater Pump 4 FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules 1. Owner: 2. Plant: Indiana Michigan Power Co., PO Box 60, Ft. Wayne, IN 46801 (Name and Address of Owners)Donald C. Cook Nuclear Plant, One Cook Place, MI 49106 (Name and Address of Plant)3. Plant Unit: Two 4. Owner Certification of Authorization (if required):
REPORT Acronyms CCW     Component Cooling Water System CS       Emergency Core Cooling System CTS     Containment Spray System ESW     Essential Service Water System' FW       Feedwater System MDAFP   Motor Driven Auxiliary Feedwater Pump MS       Main Steam System NOP     Normal Operating Pressure NOT     Normal Operating Temperature RCP     Reactor Coolant Pump RCS     Reactor Coolant System RHR     Residual Heat Removal Syktem RWST     Refueling Water Storage Tank SI       Safety Injection System TDAFP   Turbine Driven Auxiliary Feedwater Pump 4
N/A 5. Commercial Service Date: 07/01/78 6. National Board Number for Unit: 1 (Mich. M-324232-M?)
 
: 7. Components Inspected Component or Manufacturer or Manufacturer or State or Province National Board Appurtenance Installer Installer Serial Number Number Number Reactor Pressure Chicago Bridge T-1 M-324232-M I Vessel and Iron Steam Generator, Westinghouse/MK 1341- Upper, M-324-234-M 68-73 -Upper 2-OME-3-1 -Ferguson Assembly 37 -Lower 3367G -Lower Assembly East RHR Heat Westinghouse/MK 1344 -Upper M-324-237-M 68-76 -Upper Exchanger -Ferguson Assembly 38 -Lower 2-HE-17E 3368G -Lower Assembly Pressurizer Westinghouse 1231 M-324233-M 6894 2-OME-4 West CTS Heat Yuba 69-G-226-ID N/A N/A Exchanger 2-HE-18W West RHR Heat Engineers and S-15586-C N/A N/A Exchanger Fabricators, INC 2-HE-17W Containment Graver N/A N/A N/A Piping Systems -Power Systems N/A N/A N/A RCS, RHR, SI, Inc. and TUBECO CTS, CCW, CS, ESW, FW, MS Pipe Supports Grinnell 5
FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
: 8. Examination Dates: November 10, 2004 to May 5. 2006 9. Inspection Period Identification:
: 1. Owner:         Indiana Michigan Power Co., PO Box 60, Ft. Wayne, IN 46801 (Name and Address of Owners)
Second 10. Inspection Interval Identification:
: 2. Plant:        Donald C. Cook Nuclear Plant, One Cook Place, Brid*gman, MI 49106 (Name and Address of Plant)
Third 11. Applicable Edition of Section XI 1989 no Addenda & 1992 with 1992 Addenda 12. Date/Revision of Inspection Plan: 8/03 Rev. I 13. Abstract of Examinations.
: 3. Plant Unit: Two
Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.See Sections 3, 4, 5, 6, and 7 14. Abstract of Results of Examinations and Tests.See Sections 3, 4, 5, 6 and 7 15. Abstract of Corrective Measures.See Sections 3, 4, 5, 6, and 7 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code; -Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section X).Certificate of Authorization No. (if applicable)
: 4. Owner Certification of Authorization (if required):       N/A
N/A Expiration Date N/A Date .'D' _, 4 20 No Signed Indiana Michigan Power Co. By Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of,.e,- tt,,) K and employed by An_? CJ.P.. /IAIz of Agljh.&jny ,r.4" have inspected the components described in this Owner's Report during the period,,,.,,i, /v ,to LIE 4 1e. .,0. , and state that to the best of my knowledge and belief, the Owner has performed examiniiations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
: 5. Commercial Service Date: 07/01/78
SCommissions Vz- cj/Inspector s Signature National Board, State, Province, and Endorsements D ate 20oe.6 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 3 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR CLASS 1 AND CLASS 2 COMPONENTS Inservice examinations were performed during the period November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Third 10-Year Interval, Second Inspection Period, -Second Refueling Outage (Unit 2 Cycle 16). All examinations were in accordance with the 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda as applicable.
: 6. National Board Number for Unit: 1 (Mich. M-324232-M?)
Examinations were scheduled and performed according to the Third Ten-Year Long Term Inservice Examination Plan for Class 1, 2, and 3 Systems and Components for CNP, Unit 2. This is the currently approved ISI examination plan that identifies specific activities to be performed on a refueling outage basis.Twenty-six (26) ASME Class 1 and twenty-eight (28) ASME Class 2 components were examined.
: 7. Components Inspected Component or         Manufacturer or   Manufacturer or State or Province National Board Appurtenance         Installer         Installer Serial Number           Number Number Reactor Pressure     Chicago Bridge           T-1       M-324232-M               I Vessel             and Iron Steam Generator,   Westinghouse/MK     1341- Upper,   M-324-234-M       68 Upper 2-OME-3-1             -Ferguson         Assembly                         37 - Lower 3367G - Lower Assembly East RHR Heat     Westinghouse/MK     1344 - Upper   M-324-237-M       68 Upper Exchanger             -Ferguson         Assembly                         38 - Lower 2-HE-17E                           3368G - Lower Assembly Pressurizer         Westinghouse           1231       M-324233-M             6894 2-OME-4 West CTS Heat               Yuba     69-G-226-ID             N/A               N/A Exchanger 2-HE-18W West RHR Heat         Engineers and     S-15586-C           N/A               N/A Exchanger         Fabricators, INC 2-HE-17W Containment             Graver             N/A             N/A               N/A Piping Systems -       Power Systems           N/A             N/A               N/A RCS, RHR, SI,       Inc. and TUBECO CTS, CCW, CS, ESW, FW, MS Pipe Supports           Grinnell 5
A combination of Ultrasonic, Magnetic Particle, Liquid Penetrant and Visual examination methods were used. Two supports failed the VT-3 examination.
: 8. Examination Dates: November 10, 2004 to May 5. 2006
Support 2-ACS-R-913 had a loose nut on an embedment plate that was evaluated as an original construction defect and not inservice induced and documented via Work Request 06016013.
: 9. Inspection Period Identification: Second
Support 2-AFW-C-4034 also had a loose nut on a-pipe clamp. This condition was evaluated by Design Engineering (Condition Report 06102054) and Engineering Programs and found acceptable.
: 10. Inspection Interval Identification: Third
The cause was attributed to original construction.
: 11. Applicable Edition of Section XI 1989 no Addenda & 1992 with 1992 Addenda
The supports upstream, downstream and in the immediate vicinity of these two supports were examined and found acceptable.
: 12. Date/Revision of Inspection Plan: 8/03 Rev. I
No sample expansions were required.To proactively address issues with Primary Water Stress Corrosion Cracking (PWSCC)of Alloy 82/182 weld locations in the Unit 2 pressurizer safe ends, all the safe ends on the Unit 2 pressurizer received Pre-emptive Weld Overlays (PWOL) to mitigate the potential for PWSCC. Each location received a fully qualified ASME Section XI Appendix VIII, Supplement 11 ultrasonic examination and a surface examination over 100% of the required weld volume. No evidence of PWSCC or other rejectable indications were observed.During the Unit 2, Cycle 16 refueling outage, Indiana Michigan Power Company (I&M), the licensee for CNP Unit 2, performed a bare-metal visual inspection of the CNP Unit 2 reactor pressure vessel (RPV) bottom-mounted instrumentation (BMI) nozzle penetrations, and bare-metal and volumetric examinations of the RPV upper head in response to NRC Revised Order EA-03-009, "Issuance of Order Establishing Interim 7 Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors".
: 13. Abstract of Examinations. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
The BMI inspection was conducted by contractor and I&M personnel, and included personnel qualified as American Society of Mechanical Engineers Code, Section XI, Level II examiners.
See Sections 3, 4, 5, 6, and 7
The bottom two sections of insulation were lowered to allow unobstructed access to all penetrations and the membrane areas of the lower reactor vessel. A pole-mounted camera was used to perform a VT-2 examination to VT-3 examination criteria for distance and lighting on all 58 Unit2 RPV BMI nozzle penetrations, including 360 degrees around each BMI penetration.
: 14. Abstract of Results of Examinations and Tests.
No boric acid deposits were found at any RPV BMI nozzle penetration or anywhere on the RPV bottom-head surface area. No boric acid residue sampling or analysis was required or performed.
See Sections 3, 4, 5, 6 and 7
The as-found condition of the Unit 2 RPV bottom head was identical to the as-left condition following the bottom cleaning and re-inspection performed during the Unit 2, Cycle 15 refueling outage. No indications of through-wall leakage were found during the Unit 2, Cycle 16 RPV BMI inspection.
: 15. Abstract of Corrective Measures.
The inspection results were digitally recorded, and copies of the video files were saved to computer drives as video clips.A 100% bare-metal visual examination of the Unit 2 RPV upper head showed no evidence of pressure boundary leakage. However, evidence of above-head leakage from an external source was discovered near Penetration Number 42. To ensure that the source of residue was not the result of pressure-boundary leakage, the following were performed.
See Sections 3, 4, 5, 6, and 7 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code; -Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section X).
Certificate of Authorization No. (if applicable)         N/A           Expiration Date N/A Date .'D'       _, 4 20 No Signed     Indiana Michigan Power Co. By Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of,.e,- tt,,) K             and employed by An_? CJ.P..     /IAIz of Agljh.&jny     ,r.4"       have inspected the components described in this Owner's Report during the period,,,.,,i,       /v ,to   LIE41e. .,0.   , and state that to the best of my knowledge and belief, the Owner has performed examiniiations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
SCommissions                                 Vz-                   cj/
Inspector s Signature                                   National Board, State, Province, and Endorsements D     ate                       20oe.
6
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 3 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR CLASS 1 AND CLASS 2 COMPONENTS Inservice examinations were performed during the period November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Third 10-Year Interval, Second Inspection Period, -Second Refueling Outage (Unit 2 Cycle 16). All examinations were in accordance with the 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda as applicable.
Examinations were scheduled and performed according to the Third Ten-Year Long Term Inservice Examination Plan for Class 1, 2, and 3 Systems and Components for CNP, Unit 2. This is the currently approved ISI examination plan that identifies specific activities to be performed on a refueling outage basis.
Twenty-six (26) ASME Class 1 and twenty-eight (28) ASME Class 2 components were examined. A combination of Ultrasonic, Magnetic Particle, Liquid Penetrant and Visual examination methods were used. Two supports failed the VT-3 examination. Support 2-ACS-R-913 had a loose nut on an embedment plate that was evaluated as an original construction defect and not inservice induced and documented via Work Request 06016013. Support 2-AFW-C-4034 also had a loose nut on a-pipe clamp. This condition was evaluated by Design Engineering (Condition Report 06102054) and Engineering Programs and found acceptable. The cause was attributed to original construction. The supports upstream, downstream and in the immediate vicinity of these two supports were examined and found acceptable. No sample expansions were required.
To proactively address issues with Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 82/182 weld locations in the Unit 2 pressurizer safe ends, all the safe ends on the Unit 2 pressurizer received Pre-emptive Weld Overlays (PWOL) to mitigate the potential for PWSCC. Each location received a fully qualified ASME Section XI Appendix VIII, Supplement 11 ultrasonic examination and a surface examination over 100% of the required weld volume. No evidence of PWSCC or other rejectable indications were observed.
During the Unit 2, Cycle 16 refueling outage, Indiana Michigan Power Company (I&M),
the licensee for CNP Unit 2, performed a bare-metal visual inspection of the CNP Unit 2 reactor pressure vessel (RPV) bottom-mounted instrumentation (BMI) nozzle penetrations, and bare-metal and volumetric examinations of the RPV upper head in response to NRC Revised Order EA-03-009, "Issuance of Order Establishing Interim 7
 
Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors".
The BMI inspection was conducted by contractor and I&M personnel, and included personnel qualified as American Society of Mechanical Engineers Code, Section XI, Level II examiners. The bottom two sections of insulation were lowered to allow unobstructed access to all penetrations and the membrane areas of the lower reactor vessel. A pole-mounted camera was used to perform a VT-2 examination to VT-3 examination criteria for distance and lighting on all 58 Unit2 RPV BMI nozzle penetrations, including 360 degrees around each BMI penetration. No boric acid deposits were found at any RPV BMI nozzle penetration or anywhere on the RPV bottom-head surface area. No boric acid residue sampling or analysis was required or performed. The as-found condition of the Unit 2 RPV bottom head was identical to the as-left condition following the bottom cleaning and re-inspection performed during the Unit 2, Cycle 15 refueling outage. No indications of through-wall leakage were found during the Unit 2, Cycle 16 RPV BMI inspection. The inspection results were digitally recorded, and copies of the video files were saved to computer drives as video clips.
A 100% bare-metal visual examination of the Unit 2 RPV upper head showed no evidence of pressure boundary leakage. However, evidence of above-head leakage from an external source was discovered near Penetration Number 42. To ensure that the source of residue was not the result of pressure-boundary leakage, the following were performed.
* A chemical sample analysis, which determined the residue to be 1.3 to 1.6 years old, was performed.
* A chemical sample analysis, which determined the residue to be 1.3 to 1.6 years old, was performed.
* Extensive visual examinations of Penetration 42 (prior to and after residue sampling and cleaning) were performed.
* Extensive visual examinations of Penetration 42 (prior to and after residue sampling and cleaning) were performed. The examination indicated that the origin of the residue was not from the annular gap between the vessel head and the penetration tube. Evidence of previous above-head leakage, including pooling and dripping, was observed on the insulation panel seam in the vicinity above Penetration 42.
The examination indicated that the origin of the residue was not from the annular gap between the vessel head and the penetration tube. Evidence of previous above-head leakage, including pooling and dripping, was observed on the insulation panel seam in the vicinity above Penetration 42.0 A volumetric examination, including ultrasonic/eddy current of the inside diameter of the penetration tube, was performed.
0   A volumetric examination, including ultrasonic/eddy current of the inside diameter of the penetration tube, was performed. No rejectable indications were found and no evidence of leakage in the shrink-fit region was observed in the J-groove weld inspection data.
No rejectable indications were found and no evidence of leakage in the shrink-fit region was observed in the J-groove weld inspection data.& Supplemental eddy current examinations of the J-groove weld and penetration tube outside diameter surfaces were conducted.
            &   Supplemental eddy current examinations of the J-groove weld and penetration tube outside diameter surfaces were conducted. No rejectable indications were observed in the J-groove weld inspection data.
No rejectable indications were observed in the J-groove weld inspection data.* A manual surface examination using liquid penetrant was performed on the Penetration 42 nozzle immediately above the reactor vessel closure head. No indications were observed.A 100 % volumetric examination of the 78 control rod drive mechanism penetrations and the single vent penetration in the Unit 2 RPV head was completed in accordance with Section IV.C(5)(b)(iii) utilizing an approved relaxation of the requirements obtained in 8 accordance with Section JV.F. No unacceptable indications were found. No repairs of any head penetrations were needed or performed.
* A manual surface examination using liquid penetrant was performed on the Penetration 42 nozzle immediately above the reactor vessel closure head. No indications were observed.
System pressure tests did not reveal any degradation of the system pressure boundary or the installed bolting.The following Code Cases were utilized during this reporting period: N-416-1 N-460 N-504-2 N-509 N-533 N-616 N-638-1 N-627 N-491 -1 Nondestructive examinations were performed by WesDyne, AREVA/Framatome and I&M personnel in accordance with procedures approved for use at CNP.9 Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 3. Plant Unit: TWO 4. Owner Certificate of Authorization (If Req.): NIA 5. Commercial Service Date: 0710111978
A 100 % volumetric examination of the 78 control rod drive mechanism penetrations and the single vent penetration in the Unit 2 RPV head was completed in accordance with Section IV.C(5)(b)(iii) utilizing an approved relaxation of the requirements obtained in 8
: 6. National Board Number for Unit: 1 (Mich. M-324232-M)Summary No.Component Description Component ID Item Procedure  
 
.Method/Reoort/Results Class I Category B-B 006500 2-PRZ-15 006900 008600 2-PRZ-19 STM-21-01 UPPER HEAD TO UPPER SHELL LONGITUDINAL SEAM LOWER HEAD TO TUBE SHEET 1 THROUGH 54 B2.11 54-IS1-130 54-IS1-130 54-ISI-130 B2.12 54-ISI-130 54-IS1-130 54-ISI-130 54-ISI-130 54-ISI-130 54-ISI-130 B2.40 54-1S1-130 54-IS1-130 54-ISI-130 54-ISI-130 54-ISI-130 86.40 54-1S1-108 IUT UT UT UT UT UT UT UT IUT UT UT UT UT UT UT-06-028 UT-06-031 UT-06-032 UT-06-029 UT-06-026 UT-06-025 UT-06-030 UT-06-024 UT-06-023 UT-06-013 UT-06-016 UT-06-015 UT-06-014 UT-06-017 Accept Accept Accept Accept Accept Accept Accept Accept Accept Info Accept Accept Accept Accept 54-IS1-130 UT UT-06-027 Accept Class 004700 1 Category B-G-1 2-RPV-FLANGE THREADS UT UT-06-004 Accept 10
accordance with Section JV.F. No unacceptable indications were found. No repairs of any head penetrations were needed or performed.
: 1. Owner: indiana Michigan Power Co., PO Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 3. Plant Unit: TWO Summary Component No. Component ID Description Class I Category B-G-2 030400 2-RC-26-09-FB FLANGE BOLTING 049000 2-RC-32-13-FB FLANGE BOLTING 053100 2-RC-33-18-FB FLANGE BOLTING 071600 2-RC-515-21-FB FLANGE BOLTING 078600 2-RC-517-23-FB FLANGE BOLTING 153075 PUMP BOLTS (12 -2" BOLTS) LOWER SEAL HOUS Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16 4. Owner Certificate of Authorization (If Req.): NIA 5. Commercial Service Date: 0710111978
System pressure tests did not reveal any degradation of the system pressure boundary or the installed bolting.
: 6. National Board Number for Unit: I (Mich. M-324232.M)Item Procedure Method/Report/Results ING B7.50 B7.50 B7.50 B7.50 B7.50 B7.50...........  
The following Code Cases were utilized during this reporting period:
* .. ...... I 220200 220700 221550 222400 Class I 088100 SV-45A SI-170-L2 IMO-325 IMO-128 Category B-J 2-SI-56-03 BOLTS BODY TO BONNET BODY TO BONNET BOLTING FLANGE BOLTING FLANGE BOLTING ELBOW TO PIPE 12-QHP-5050-NDE-006 12-QHP-5050-, NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-, NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 VT VT VT VT VT VT VT-06-021 VT-06-038 V17-06-041 VT-06-039 VT-06-037 VT-06-036 Accept Accept Accept Accept Accept Accept B7.70 B7.70 B7.70 B7.70 VT VT VT VT VT-06-018B VT-06-029 VT-06-033 VT-06-028 Accept Accept Accept Accept B9.11 54-ISI-836 UT UT-06-011 Accept 11 Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 3. Plant Unit: TWO 4. Owner Certificate of Authorization (If Req.): NIA 5. Commercial Service Date: 0710111978
N-416-1 N-460 N-504-2 N-509 N-533 N-616 N-638-1 N-627 N-491 -1 Nondestructive examinations were performed by WesDyne, AREVA/Framatome and I&M personnel in accordance with procedures approved for use at CNP.
: 6. National Board Number for Unit: I (Mich. M-324232-M)Summary No.Component Description Component ID 089750 092700 151900 Class 1 094800 2-SI-56-1 9 2-SI-57-17 2-WD-822-03 TEE TO PiPE Item Procedure 54-ISI-836 89.11 54-1SI-836 54-ISI-836 54-1SI-836 B9.11 54*ISI-836 54-ISI-836 89.40 54-ISI-836 Method/Report/Results UT UT-06-012 Accept UT UT-06-019 Accept UT UT-06-018 Accept UT UT-06-020 Accept UT UT-06-022 Accept UT UT-06-021 Accept UT UT-06-038 Accept=L ....PIPE TO ELBOW ELBOW TO PIPE 54-ISI-836 UT UT-06-037 Accept Category B-K-1 2-SI-58-03-PL I AND 2 Category B-N-1 RPV UPPER INTERNALS
9
&SURFACES PIPE LUG Class 006010 I AREAS ACCESSIBLE DURING NORMAL REFUELING PIPE SUPPORT COMPONENT 810.10 12-QHP-5050-NDE-001 813.10 54-ISI-364 F1.10 12-QHP-5050-WA NDE-006 VT VE-06-001 Accept VT VT-06-035 Accept PT PT-06-003 Accept Class 1 Category F-A 600700 2-GRC-R-524 12
 
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 3. Plant Unit: TWO Summary Component No. Component ID Description Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16 4. Owner Certificate of Authorization (If Req.): NIA 5. Commercial Service Date: 0710111978
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
: 6. National Board Number for Unit: I (Mich. M-324232-M)Item Procedure Method/Report/Results 601200 604400 607330 607800 609220 Class 2 300070 300090 300700 2-ARC-R-522B 2-GRC-R-565 2-ASI-R-5301 2-GSI-R-698 2-GCS-R-543 PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT NOZZLE TO SHELL NOZZLE TO SHELL F1.101 FI.10A F1.10A Fl.10A F1.10 WB 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 VT VT-06-020 Accept VT VT VT VT VT-06-042 Vr-06-032 VT-06-031 VT-06-027 Accept Accept Accept Accept Category C-B STM-21-FWN STM-21-FWN-IRS E-RHRHEX-IN C2.21 54-ISI-130 54-ISI-130 54-151-130 C2.22 54-ISI-132 C2.21 54-ISI-136 54-ISI-240 54-ISI-136 54-IS1-136 UT UT UT UT UT PT IUT UT UT-06-033 UT-06-034 UT-06-035 UT-06-036 UT-06-005 PT-06-002 UT-06-006 UT-06-007 Accept Accept Accept Accept Info Accept Accept Info 13 Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, Mi 49106 3. Plant Unit: TWO 4. Owner Certificate of Authorization (If Req.): NIA 5. Commercial Service Date: 0710111978
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.
: 6. National Board Number for Unit: I (Mich. M-324232-M)Summary No.Component Description Comoonent ID Item Procedure Method/RenootResults Ile Procedure Method/Rer)ort/Results 300871 300873 300874 Class 2 310915 2-ILA-110-Vl 2-ILA-111-Vl 2-ILA-11 l-V2 Category C-C 2-SI-9-05S-PS 1 THRU 4 4 INSTRUMENT NOZZLE TO SHELL INSTRUMENT NOZZLE TO SHELL INSTRUMENT NOZZLE TO SHELL PIPE LUG PENETRATION SUPPORT WELD CYLINDER WELD C2.21 54-ISI-836 C2.21 C2.21 54-ISI-836 54-ISI-836 UT UT UT-06-010 Accept UT-06-008 Accept UT UT-06-009 Accept C3.20 12-QHP-5050-NDE-001 PT PT-06-001 Accept 319170 323060 323070 Class 2 322950 Class 2 700010 700020 2-FW-74-OIF MSIV-MRV-230-S1 MSIV-MRV-230-S2 Category C-G MSIV-MRV-210-1 Category F-A CS-1 CS-2 C3.20 C3.40 C3.40 12-QHP-5050-NDE-001 12-QHP-5050-NDE-002 12-QHP-5050-NDE-002 PT MT MT PT-06-004 Accept MT-06-001 Accept MT-06-002 Accept C6.20 12-QHP-5050-NDE-002 MT MT-06-003 Accept VT VT-06-014 Accept VT V17-06-015 Accept BRACKET BRACKET F1.40 F1.40 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 14
Wayne, IN 46801                                                                             4. Owner Certificate of Authorization (If Req.): NIA
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 3. Plant Unit: TWO Summary Component No. Component ID Description Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16 4. Owner Certificate of Authorization (If Req.): NIA 5. Commercial Service Date: 0710111978
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106                                                                         5. Commercial Service Date: 0710111978
: 6. National Board Number for Unit: I (Mich. M-324232-M)Item Procedure Method/Report/Results 700040 713097 713285 713870 713940 714120 716065 716240 751600 754600 CS-4 2-ARH-R-5011 2-GRH-V-9 2-GCTS-L-43 2-GCTS-R-46 2-GCTS-V-54 2-GCTS-R-17 2-GCTS-R-8 2-GFW-V-881  AFW-C-4034 BRACKET F-A F1l.20ACOMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE RESTRAINT COMPONENT PIPE SUPPORT COMPONENT F1.40 F1.20A F1.20 WC Fl.20B F1.20B F1.20C F1.20A F1.20 WB F1.20C F1.20C 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-.
: 6. National Board Number for Unit: 1 (Mich. M-
NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-VT VT VT VT VT VT VT VT VT VT VT-06-017 Vr-06-03Q VT-06-034 VT-06-022 V17-06-024 V17-06-040 VT-06-005 VT-06-006 VT-06-01 9 VT-06-043 Accept Accept Accept Accept Accept Accept Accept Accept Accept Reject NDE-006 Evaluation Disposition Acceptable:
: 3. Plant Unit: TWO                                                                          324232-M)
Acceptable per DES evaluation contained in CRE 06102054.15 Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16 1. Owner: Indiana Michigan Power Co., P0 Box 60, Ft.Wayne, IN 46801 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 3. Plant Unit: TWO 4. Owner Certificate of Authorization (if Req.): NIA 5. Commercial Service Date: 0710111978
Summary                                 Component No.           Component ID              Description             Item   Procedure . Method/Reoort/Results Class I     Category B-B 006500         2-PRZ-15                 UPPER HEAD TO UPPER    B2.11  54-IS1-130    UT UT-06-027 Accept SHELL 54-IS1-130     IUTUT-06-028 Accept 54-IS1-130   UT UT-06-031  Accept 54-ISI-130   UT UT-06-032  Accept 006900        2-PRZ-19                  LONGITUDINAL SEAM      B2.12  54-ISI-130   UT UT-06-029  Accept 54-IS1-130   UT UT-06-026  Accept 54-ISI-130   UT UT-06-025  Accept 54-ISI-130   UT UT-06-030  Accept 54-ISI-130   UT UT-06-024  Accept 54-ISI-130    IUTUT-06-023 Accept 008600        STM-21-01                LOWER HEAD TO TUBE      B2.40  54-1S1-130  UT UT-06-013  Info SHEET 54-IS1-130  UT  UT-06-016 Accept 54-ISI-130  UT UT-06-015 Accept 54-ISI-130  UT  UT-06-014 Accept 54-ISI-130   UT UT-06-017 Accept Class 1     Category B-G-1 004700        2-RPV-FLANGE THREADS       1 THROUGH 54            86.40    54-1S1-108  UT UT-06-004 Accept 10
: 6. National Board Number for Unit: 1 (Mich. M-324232-M)Summary No.763240 763710 763740 764210 764380 764940 Component ID 2-GSI-L-30 2-GSI-R-822 2-GSI-L-826 2-ACS-R-1 15 2-GCS-L-123 2-ACS-R-913 Component Description PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT PIPE SUPPORT COMPONENT Item F1.20A F1.20 WA F1.20 WA F1.20 WB F1.20 WA F17.20B Procedure 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 12-QHP-5050-NDE-006 Method/Report/Results VT VT-06-023 Accept VT VT-06-026 Accept VT VT-06-025 Accept VT VT-06-009 Accept VT VT-06.007 Accept VT VT-06-008 Reject 16 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 4 ABSTRACT OF SYSTEM PRESSURE TESTS RESULTS Inservice Inspection System Pressure Tests were performed during the period November 10, 2004, to May 5, 2006. These tests were performed in accordance with the requirements of ASME Section XI, 1989 (no Addenda) and 1992 Editions with 1992 Addenda, Articles IWA-5000, IWB-5000, IWC-5000, IWD-5000, Code Case N-416-1, Code Case N-533 and N-616, as applicable.
 
Pressure tests for portions of systems identified below were performed during this outage.The remainder of the pressure tests for the period will be performed in conjunction with functional tests, inservice operation, and special procedures as applicable.
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
No pressure boundary through-wall leaks were identified.
: 1. Owner: indiana Michigan Power Co., PO Box 60, Ft.
Job Completion Order Activity Test Description Date R0227736 2 North SI pump and associated piping 5/6/2006 R0227736 4 South SI pump and associated piping 5/612006 R0227736 6 Accumulators and associated piping 4/17/2006 R0227736 8 Bit tank and associated piping 3/25/2006 R0227736 9 South seal water injection filter 3124/2006 R0227736 10 North seal water injection filter 4/17/2006 R0227736 11 East Charging Pump and associated piping 3/24/2006 R0227736 12 West Charging Pump and associated piping 4/19/2006 R0227736 13 East CTS Pump and Associated Piping 4/11/2006 R0227736 14 West CTS Pump and Associated Piping 5/5/2006 R0227736 15 Spray Additive tank and associated piping 3/24/2006 R0227736 16 Seal water leak off piping at RCPs 5/6/2006 R0227736 17 Seal water filter, heat exchanger, and associated piping 3/25/2006 R0227736 18 TDAFP Motor Operated Valves to Check Valves 4/30/2006 R0227736 19 Letdown heat exchanger and associated piping 5/5/2006 R0227736 23 TDAFP and associated piping 5/5/2006 R0227736 24 East MDAFP and associated piping 5/5/2006 R0227736 25 West MDAFP and associated piping 8/26/2005 R0266778 1 RCS NOP/NOT 8/24/2005 R0233818 2 ESW Pumps and associated piping 5/6/2006 R0243844 1 Condensate Storage Tank and Associated Piping 5/6/2006 R0243844 2 RWST and associated piping 4/17/2006 R0243844 3 South Spent Fuel Pool Pumps and Associated Piping 3/25/2006 R0243844 4 North Spent Fuel Pool Pumps and Associated Piping 3/24/2006 R0243844 5 South Boric Acid Storage Tank and Associated Piping 4/17/2006 R0243844 6 Volume Control Tank and Associated Piping 3124/2006 17 INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 SECTION 5 ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS Snubber examinations and functional testing were performed in conjunction with the maintenance procedures implemented to satisfy technical specification surveillance requirements.
Wayne, IN 46801                                                                                 4. Owner Certificate of Authorization (If Req.): NIA
Provided is a summary of the as-found visual examinations and as-found functional test results.Snubber VT-3 Visual Examinations Snubber No. Exam Date Job Order No. Results 2-GRC-$537 04-04-06 R0266439 Acceptable 2-GRC-S538 04-18-06 R0266439 Acceptable 2-GRC-$555 04-18-06 R0266439 Acceptable 2-GRC-$562 04-04-06 R0266439 Acceptable 2-GRC-$564 04-18-06 R0266439 Acceptable 2-GRC-$566 04-04-06 R0266439 Acceptable 2-GRC-$573 04-18-06 R0266439 Acceptable 2-GRC-S575 04-04-06 R0266439 Acceptable 2-GRC-S582 04-18-06 R0266439 Acceptable 2-GRC-S592 04-04-06 R0266439 Acceptable 2-GRC-S594 04-04-06 R0266439 Acceptable 2-GRC-S596 04-04-06 R0266439 Acceptable 2-GRC-S598 04-04-06 R0266439 Acceptable 2-GRC-S599 04-18-06 R0266439 Acceptable 2-GRC-S609 04-04-06 R0266439 Acceptable 2-GRC-S611 04-04-06 R0266439 Acceptable 2-GRC-S623 04-04-06 R0266439 Acceptable 2-GRC-S624 04-18-06 R0266439 Acceptable 2-GRC-S626 04-04-06 R0266439 Acceptable 2-GRC-S629 04-04-06 R0266439 Acceptable 2-GRC-S630 04-04-06 R0266439 Acceptable 2-GRC-S632 04-04-06 R0266439 Acceptable 2-GRC-S631 04-04-06 R0266439 Acceptable 2-GRC-S587 04-04-06 R0266439 Acceptable 2-AFW-S4023 04-13-06 R0266100 Acceptable 2-AFW-S4024(L) 04-13-06 R0266100 Acceptable 2-AFW-S4024(U) 04-13-06 R0266100 Acceptable 2-AFW-S4021 04-13-06 R0266100 Acceptable 2-AFW-S4028(L) 04-13-06 R0266100 Acceptable 2-AFW-S4028(U) 04-13-06 R0266100 I Acceptable 18 INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 Snubber VT-3 Visual Examinations (Continued)
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106                                                                             5. Commercial Service Date: 0710111978
Snubber No. Exam Date Job Order No. Results 2-AFW-S4027 04-13-06 R0266100 Acceptable 2-AFW-S4025 04-13-06 R0266100 Acceptable 2-AFW-S4031 04-13-06 R0266100 Acceptable 2-AFW-S4032(L) 04-13-06 R0266100 Acceptable 2-AFW-S40.32(L_
: 6. National Board Number for Unit: I (Mich. M-
04-13-06 R0266100 Acceptable 2-AFW-S4029 04-13-06 R0266100 Acceptable 2-AFW-S4036(L) 04-13-06 R0266100 Acceptable 2-AFW-S4036(U) 04-13-06" R0266100 Acceptable 2-AFW-S4035 04-13-06 R0266100 Acceptable 2-AFW-S4033 04-13-06 R0266100 Acceptable 2-GBD-S563(L) 04-12-06 R0266147 Acceptable 2-GBD-S563(U) 04-12-06 R0266147 Acceptable 2-GBD-S569(L 04-12-06 R0266147 Acceptable 2-GBD-S569(U) 04-12-06 R0266147 Acceptable 2-GBD-5S68 04-12-06 R0266147 Acceptable 2-GCCW-S840 02-28-06 R0263765 Acceptable 2-GCCW-S843 02-28-06 R0263765 Acceptable 2-OME-3-1-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-IL 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-3L 04-03-06 R0265677 Acceptable 2-OvE-3-2-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-IL 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-1L 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-1L 04-03-06 R0265677 Acceptable 19 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI.COMMERCIAL SERVICE DATE 7-1-1978 Snubber Functional Tests Snubber No. Test Date Job Order No. Results Remarks 2-GRC-S538 04-18-06 R0098999 Accept. Small Bore Grinnell 2-GRC-S555 04-19-06 R0099679 Accept. Small Bore Grinnell 2-GRC-S573 04-20-06 R0036212 Accept. Small Bore Grinnell 2-GRC-S611 04-19-06 R0036210 Accept. Small Bore Grinnell 2-GBD-S568 04-20-06 R0037674 Accept. Small Bore Grinnell 2-GCCW-S843 04-17-06 R0037685 Accept. Small Bore Grinnell 2-AFW-S4032-U 04-20-06 R0036689 Accept. Small Bore Grinnell 2-OME-3-4-HSD-IL 04-08-06 R0078801 Accept. Large Bore 2-OME-3-4-HSD-1U 04-07-06 R0100166 Accept. Large Bore 2-OME-3-4-HSD-3L 04-09-06 R0037382 Accept. Large Bore 2-OME-3-4-HSD-3U 04-08-06 R0058565 Accept. Large Bore The minimum 14% required sample size consists of 7 small bore (Grinnell) and 3 large bore (Steam Generator) snubbers.20 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 6 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR ASME SECTION XI, SUBSECTIONS IWE AND IWL Containment Inservice Inspections During the reporting period of November 10, 2004, to May 4, 2006, inservice inspections were performed on the Unit 2 Containment pressure retaining structure in accordance with Subsections IWE and IWL of ASME Section XI, 1992 Edition and 1992 Addenda, and 10 CFR 50.55a.The following attachment provides a listing of the examinations performed, results, and corrective actions, if any were performed.
: 3. Plant Unit: TWO                                                                              324232.M)
A General Visual Examination was performed on all accessible surfaces of the Containment liner along with examinations performed in conjunction with coating repairs, and other repair/replacement activities.
Summary                                    Component No.          Component ID                 Description             Item    Procedure      Method/Report/Results Class I     Category B-G-2 030400       2-RC-26-09-FB                 FLANGE BOLTING         B7.50  12-QHP-5050-   VT VT-06-021 Accept NDE-006 049000        2-RC-32-13-FB                 FLANGE BOLTING         B7.50  12-QHP-5050-,  VT VT-06-038 Accept NDE-006 053100        2-RC-33-18-FB               FLANGE BOLTING         B7.50  12-QHP-5050-  VT V17-06-041 Accept NDE-006 071600        2-RC-515-21-FB              FLANGE BOLTING          B7.50   12-QHP-5050-, VT VT-06-039 Accept NDE-006 078600        2-RC-517-23-FB              FLANGE BOLTING          B7.50   12-QHP-5050-  VT VT-06-037 Accept NDE-006 153075        PUMP BOLTS (12 - 2" BOLTS)
An acceptance criteria providing the acceptable minimum thickness of the containment liner was established for the examination of the concrete-backed liner. The examination results were compared to the acceptance criteria.
              ...........   * .. . ..... I LOWER SEAL HOUS ING      B7.50  12-QHP-5050- VT VT-06-036 Accept BOLTS                            NDE-006 220200        SV-45A                      BODY TO BONNET           B7.70  12-QHP-5050- VT VT-06-018B Accept NDE-006 220700        SI-170-L2                    BODY TO BONNET          B7.70  12-QHP-5050- VT VT-06-029 Accept BOLTING                        NDE-006 221550        IMO-325                      FLANGE BOLTING          B7.70  12-QHP-5050-   VT VT-06-033 Accept NDE-006 222400        IMO-128                      FLANGE BOLTING          B7.70  12-QHP-5050-   VT VT-06-028 Accept NDE-006 Class I    Category B-J 088100        2-SI-56-03                    ELBOW TO PIPE          B9.11  54-ISI-836    UT UT-06-011 Accept 11
All results were within the established acceptance criteria.
 
No areas required to be classified as an Augmented Examination area in accordance with IWE-1240.Containment concrete examinations are currently in progress as of this report date. No degradation has been found that impacts the structural integrity of the containment concrete.
Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16
As of this report date, there have been no conditions noted in accessible areas that could indicate the presence or result in degradation to inaccessible areas.21 Program Owner: (14,,. 2A, 7 NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date: _'-0--o0:, 3125/2006 2 KuzLUI_ ,cones /- -1 (paaZ-b14-lIA, z-1 Z-1 ZA (uenerai None Accept 03 (partial)
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.
Visual _______________
Wayne, IN 46801
_________3/25/2006 2 R0246391-Moisture Barrier 2-598-MB (RCDT Area) VT-3 None Accept 02 ______________
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place,                                    4. Owner Certificate of Authorization (If Req.): NIA Bridgman, MI 49106
3/25/200612 02 General' None Accept 3252006 2 R0246391-Zones 2-598-26, 2-598-27 (partial)
: 5. Commercial Service Date: 0710111978
Visual NoneAccept R0266500al 3/2612006 2 R0266500-Penetration Bolting 2-CPN-80-BOLTING VT-1 None Accept 49 3126/2006 2 R0266500-Penetration Bolting 2-CPN-57-BOLTING VT-1 None Accept_________48 Prior to coating repair: Liner and penetrations between fence at RCDT to Col. 21 and from 3/28/2006 05132069-floor up approx. 3' and penetrations up to the 01 2nd weld channel (areas of damaged paint). VT-3 None Accept Areas between Cols. 21 and 23 and from the floor up to the 2nd weld channel including penetrations (areas of damaged paint)..05132069-Prior to coating repair: Zone 2-598-27 (partial)
: 3. Plant Unit: TWO                                                                        6. National Board Number for Unit: I (Mich. M-324232-M)
Four small areas, approx. 112" 3/30/2006 2 07 from gate at Col. 27 to concrete, floor elevation VT-3 diameter with chipped top coat. Accept up approx. 9'-0". No base metal wastage.3/30/2006 2 R0246391-Moisture Barrier 2-598-MB (Annulus area) VT-3 None Accept 1 04 1- .I I I*  
Summary                                Component No.          Component ID              Description            Item    Procedure    Method/Report/Results =L ....
54-ISI-836   UT UT-06-012 Accept 089750        2-SI-56-1 9              TEE TO PiPE            89.11  54-1SI-836    UT UT-06-019 Accept 54-ISI-836    UT UT-06-018 Accept 54-1SI-836    UT UT-06-020 Accept 092700        2-SI-57-17                PIPE TO ELBOW          B9.11  54*ISI-836    UT UT-06-022 Accept 54-ISI-836    UT UT-06-021 Accept 151900        2-WD-822-03               ELBOW TO PIPE          89.40  54-ISI-836   UT UT-06-038 Accept 54-ISI-836   UT UT-06-037 Accept Class 1    Category B-K-1 094800        2-SI-58-03-PL I AND 2    PIPE LUG                810.10  12-QHP-5050- PT PT-06-003 Accept NDE-001 Class  I    Category B-N-1 006010        RPV UPPER INTERNALS &    AREAS ACCESSIBLE      813.10  54-ISI-364    VT VE-06-001 Accept SURFACES                  DURING NORMAL REFUELING Class 1    Category F-A 600700        2-GRC-R-524              PIPE SUPPORT           F1.10   12-QHP-5050- VT VT-06-035 Accept COMPONENT              WA      NDE-006 12
 
Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.
Wayne, IN 46801                                                                             4. Owner Certificate of Authorization (If Req.): NIA
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106                                                                           5. Commercial Service Date: 0710111978
: 6. National Board Number for Unit: I (Mich. M-
: 3. Plant Unit: TWO                                                                           324232-M)
Summary                                 Component No.           Component ID               Description             Item    Procedure    Method/Report/Results 601200        2-ARC-R-522B              PIPE SUPPORT            F1.101  12-QHP-5050-  VT VT-06-020  Accept COMPONENT                      NDE-006 604400       2-GRC-R-565                PIPE SUPPORT            FI.10A  12-QHP-5050-  VT VT-06-042 Accept COMPONENT                      NDE-006 607330      2-ASI-R-5301               PIPE SUPPORT            F1.10A  12-QHP-5050- VT Vr-06-032 Accept COMPONENT                      NDE-006 607800        2-GSI-R-698              PIPE SUPPORT             Fl.10A 12-QHP-5050- VT VT-06-031  Accept COMPONENT                      NDE-006 609220        2-GCS-R-543              PIPE SUPPORT            F1.10  12-QHP-5050- VT VT-06-027 Accept COMPONENT              WB      NDE-006 Class 2    Category C-B 300070        STM-21-FWN                 NOZZLE TO SHELL        C2.21   54-ISI-130   UT UT-06-033 Accept 54-ISI-130   UT UT-06-034 Accept 54-151-130   UT UT-06-035 Accept 300090        STM-21-FWN-IRS                                    C2.22   54-ISI-132   UT UT-06-036 Accept 300700        E-RHRHEX-IN                NOZZLE TO SHELL        C2.21   54-ISI-136   UT UT-06-005 Info 54-ISI-240    PT PT-06-002 Accept 54-ISI-136    IUTUT-06-006 Accept 54-IS1-136    UT UT-06-007 Info 13
 
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.
Wayne, IN 46801                                                                           4. Owner Certificate of Authorization (If Req.): NIA
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, Mi 49106                                                                         5. Commercial Service Date: 0710111978
: 6. National Board Number for Unit: I (Mich. M-
: 3. Plant Unit: TWO                                                                        324232-M)
Summary                                 Component No.           Comoonent ID             Description            Item   Procedure     Method/RenootResults 300871        2-ILA-110-Vl                                      Ile     Procedure     Method/Rer)ort/Results INSTRUMENT NOZZLE TO    C2.21  54-ISI-836    UT  UT-06-009 Accept SHELL 300873        2-ILA-111-Vl             INSTRUMENT NOZZLE TO    C2.21  54-ISI-836    UT UT-06-010 Accept SHELL 300874        2-ILA-11 l-V2             INSTRUMENT NOZZLE TO  C2.21  54-ISI-836    UT UT-06-008 Accept SHELL Class 2    Category C-C 310915        2-SI-9-05S-PS 1 THRU 4 4 PIPE LUG               C3.20    12-QHP-5050- PT PT-06-001 Accept NDE-001 319170        2-FW-74-OIF              PENETRATION SUPPORT    C3.20   12-QHP-5050- PT PT-06-004 Accept WELD                            NDE-001 323060       MSIV-MRV-230-S1                                   C3.40  12-QHP-5050- MT MT-06-001 Accept NDE-002 323070        MSIV-MRV-230-S2                                  C3.40   12-QHP-5050- MT MT-06-002 Accept NDE-002 Class 2    Category C-G 322950        MSIV-MRV-210-1            CYLINDER WELD          C6.20  12-QHP-5050- MT MT-06-003 Accept NDE-002 Class 2    Category F-A 700010        CS-1                      BRACKET                F1.40  12-QHP-5050- VT VT-06-014 Accept NDE-006 700020        CS-2                      BRACKET               F1.40   12-QHP-5050- VT V17-06-015 Accept NDE-006 14
 
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
: 1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.
Wayne, IN 46801                                                                                     4. Owner Certificate of Authorization (If Req.): NIA
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106                                                                                   5. Commercial Service Date: 0710111978
: 6. National Board Number for Unit: I (Mich. M-
: 3. Plant Unit: TWO                                                                                   324232-M)
Summary                                 Component No.           Component ID               Description             Item      Procedure        Method/Report/Results 700040        CS-4                       BRACKET                  F1.40    12-QHP-5050-      VT VT-06-017 Accept NDE-006 713097       2-ARH-R-5011               F-A  F1l.20ACOMPONENT    F1.20A    12-QHP-5050-     VT Vr-06-03Q Accept NDE-006 713285      2-GRH-V-9                  PIPE SUPPORT            F1.20    12-QHP-5050-     VT  VT-06-034 Accept COMPONENT                WC        NDE-006 713870      2-GCTS-L-43                PIPE SUPPORT              Fl.20B  12-QHP-5050-. VT VT-06-022 Accept COMPONENT                         NDE-006 713940        2-GCTS-R-46              PIPE SUPPORT             F1.20B  12-QHP-5050-      VT V17-06-024 Accept COMPONENT                         NDE-006 714120        2-GCTS-V-54              PIPE SUPPORT             F1.20C   12-QHP-5050-     VT V17-06-040 Accept COMPONENT                          NDE-006 716065        2-GCTS-R-17              PIPE SUPPORT              F1.20A    12-QHP-5050-     VT VT-06-005 Accept COMPONENT                          NDE-006 716240        2-GCTS-R-8                PIPE SUPPORT              F1.20    12-QHP-5050-     VT VT-06-006     Accept COMPONENT                WB        NDE-006 751600        2-GFW-V-881  -           PIPE RESTRAINT            F1.20C    12-QHP-5050-     VT VT-06-01 9 Accept COMPONENT                          NDE-006 754600        2-AFW-C-4034              PIPE SUPPORT              F1.20C    12-QHP-5050-     VT VT-06-043 Reject COMPONENT                          NDE-006 Evaluation Disposition                         Acceptable per DES evaluation contained in CRE 06102054.
Acceptable:
15
 
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
: 1. Owner: Indiana Michigan Power Co., P0 Box 60, Ft.
Wayne, IN 46801                                                                         4. Owner Certificate of Authorization (if Req.): NIA
: 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106                                                                       5. Commercial Service Date: 0710111978
: 6. National Board Number for Unit: 1 (Mich. M-
: 3. Plant Unit: TWO                                                                        324232-M)
Summary                                 Component No.           Component ID               Description          Item    Procedure    Method/Report/Results 763240        2-GSI-L-30                 PIPE SUPPORT          F1.20A  12-QHP-5050- VT VT-06-023 Accept COMPONENT                      NDE-006 763710        2-GSI-R-822               PIPE SUPPORT          F1.20 12-QHP-5050- VT VT-06-026 Accept COMPONENT            WA      NDE-006 763740      2-GSI-L-826               PIPE SUPPORT          F1.20    12-QHP-5050- VT VT-06-025 Accept COMPONENT            WA      NDE-006 764210      2-ACS-R-1 15               PIPE SUPPORT          F1.20    12-QHP-5050- VT VT-06-009 Accept COMPONENT            WB      NDE-006 764380        2-GCS-L-123               PIPE SUPPORT          F1.20    12-QHP-5050- VT VT-06.007 Accept COMPONENT            WA      NDE-006 764940        2-ACS-R-913               PIPE SUPPORT           F17.20B 12-QHP-5050- VT VT-06-008 Reject COMPONENT                      NDE-006 16
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 4 ABSTRACT OF SYSTEM PRESSURE TESTS RESULTS Inservice Inspection System Pressure Tests were performed during the period November 10, 2004, to May 5, 2006. These tests were performed in accordance with the requirements of ASME Section XI, 1989 (no Addenda) and 1992 Editions with 1992 Addenda, Articles IWA-5000, IWB-5000, IWC-5000, IWD-5000, Code Case N-416-1, Code Case N-533 and N-616, as applicable.
Pressure tests for portions of systems identified below were performed during this outage.
The remainder of the pressure tests for the period will be performed in conjunction with functional tests, inservice operation, and special procedures as applicable. No pressure boundary through-wall leaks were identified.
Job                                                                            Completion Order      Activity    Test Description                                        Date R0227736            2  North SI pump and associated piping                        5/6/2006 R0227736            4  South SI pump and associated piping                        5/612006 R0227736            6  Accumulators and associated piping                        4/17/2006 R0227736            8  Bit tank and associated piping                            3/25/2006 R0227736            9  South seal water injection filter                        3124/2006 R0227736          10  North seal water injection filter                        4/17/2006 R0227736          11  East Charging Pump and associated piping                  3/24/2006 R0227736          12    West Charging Pump and associated piping                  4/19/2006 R0227736          13    East CTS Pump and Associated Piping                      4/11/2006 R0227736          14  West CTS Pump and Associated Piping                        5/5/2006 R0227736          15  Spray Additive tank and associated piping                  3/24/2006 R0227736         16  Seal water leak off piping at RCPs                          5/6/2006 R0227736         17  Seal water filter, heat exchanger, and associated piping   3/25/2006 R0227736         18  TDAFP Motor Operated Valves to Check Valves                4/30/2006 R0227736         19  Letdown heat exchanger and associated piping               5/5/2006 R0227736         23  TDAFP and associated piping                                5/5/2006 R0227736         24  East MDAFP and associated piping                           5/5/2006 R0227736         25  West MDAFP and associated piping                         8/26/2005 R0266778            1  RCS NOP/NOT                                              8/24/2005 R0233818            2  ESW Pumps and associated piping                            5/6/2006 R0243844            1  Condensate Storage Tank and Associated Piping               5/6/2006 R0243844            2  RWST and associated piping                               4/17/2006 R0243844            3  South Spent Fuel Pool Pumps and Associated Piping        3/25/2006 R0243844          4  North Spent Fuel Pool Pumps and Associated Piping        3/24/2006 R0243844            5  South Boric Acid Storage Tank and Associated Piping      4/17/2006 R0243844            6  Volume Control Tank and Associated Piping                  3124/2006 17
 
INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.
UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 SECTION 5 ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS Snubber examinations and functional testing were performed in conjunction with the maintenance procedures implemented to satisfy technical specification surveillance requirements. Provided is a summary of the as-found visual examinations and as-found functional test results.
Snubber VT-3 Visual Examinations Snubber No.            Exam Date        Job Order No.        Results 2-GRC-$537            04-04-06          R0266439          Acceptable 2-GRC-S538            04-18-06          R0266439          Acceptable 2-GRC-$555            04-18-06          R0266439          Acceptable 2-GRC-$562            04-04-06          R0266439          Acceptable 2-GRC-$564            04-18-06          R0266439          Acceptable 2-GRC-$566            04-04-06          R0266439          Acceptable 2-GRC-$573            04-18-06           R0266439           Acceptable 2-GRC-S575            04-04-06           R0266439           Acceptable 2-GRC-S582            04-18-06           R0266439           Acceptable 2-GRC-S592            04-04-06           R0266439           Acceptable 2-GRC-S594            04-04-06           R0266439           Acceptable 2-GRC-S596            04-04-06           R0266439           Acceptable 2-GRC-S598            04-04-06           R0266439           Acceptable 2-GRC-S599            04-18-06           R0266439           Acceptable 2-GRC-S609            04-04-06           R0266439           Acceptable 2-GRC-S611            04-04-06           R0266439           Acceptable 2-GRC-S623            04-04-06           R0266439           Acceptable 2-GRC-S624            04-18-06           R0266439           Acceptable 2-GRC-S626            04-04-06           R0266439           Acceptable 2-GRC-S629            04-04-06           R0266439           Acceptable 2-GRC-S630            04-04-06           R0266439           Acceptable 2-GRC-S632            04-04-06           R0266439           Acceptable 2-GRC-S631            04-04-06           R0266439           Acceptable 2-GRC-S587            04-04-06           R0266439           Acceptable 2-AFW-S4023            04-13-06           R0266100          Acceptable 2-AFW-S4024(L)            04-13-06           R0266100          Acceptable 2-AFW-S4024(U)            04-13-06           R0266100          Acceptable 2-AFW-S4021            04-13-06           R0266100          Acceptable 2-AFW-S4028(L)            04-13-06           R0266100          Acceptable 2-AFW-S4028(U)            04-13-06           R0266100      I    Acceptable 18
 
INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.
UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 Snubber VT-3 Visual Examinations (Continued)
Snubber No.          Exam Date            Job Order No. Results 2-AFW-S4027            04-13-06             R0266100   Acceptable 2-AFW-S4025            04-13-06              R0266100    Acceptable 2-AFW-S4031            04-13-06              R0266100    Acceptable 2-AFW-S4032(L)           04-13-06             R0266100   Acceptable 2-AFW-S40.32(L_          04-13-06             R0266100   Acceptable 2-AFW-S4029            04-13-06             R0266100   Acceptable 2-AFW-S4036(L)           04-13-06             R0266100   Acceptable 2-AFW-S4036(U)           04-13-06"            R0266100   Acceptable 2-AFW-S4035            04-13-06             R0266100   Acceptable 2-AFW-S4033            04-13-06             R0266100   Acceptable 2-GBD-S563(L)          04-12-06             R0266147    Acceptable 2-GBD-S563(U)           04-12-06             R0266147    Acceptable 2-GBD-S569(L            04-12-06             R0266147    Acceptable 2-GBD-S569(U)            04-12-06             R0266147    Acceptable 2-GBD-5S68            04-12-06             R0266147    Acceptable 2-GCCW-S840            02-28-06             R0263765    Acceptable 2-GCCW-S843            02-28-06             R0263765    Acceptable 2-OME-3-1-HSD-3U          04-03-06             R0265677    Acceptable 2-OME-3-1-HSD-3L          04-03-06             R0265677    Acceptable 2-OME-3-1-HSD-1U          04-03-06             R0265677    Acceptable 2-OME-3-1-HSD-IL          04-03-06             R0265677    Acceptable 2-OME-3-2-HSD-3U          04-03-06             R0265677    Acceptable 2-OME-3-2-HSD-3L          04-03-06             R0265677    Acceptable 2-OvE-3-2-HSD-1U          04-03-06             R0265677   Acceptable 2-OME-3-2-HSD-IL          04-03-06             R0265677   Acceptable 2-OME-3-3-HSD-3U          04-03-06             R0265677   Acceptable 2-OME-3-3-HSD-3L          04-03-06             R0265677   Acceptable 2-OME-3-3-HSD-1U          04-03-06             R0265677   Acceptable 2-OME-3-3-HSD-1L          04-03-06             R0265677   Acceptable 2-OME-3-4-HSD-3U          04-03-06             R0265677   Acceptable 2-OME-3-4-HSD-3L          04-03-06             R0265677   Acceptable 2-OME-3-4-HSD-1U          04-03-06             R0265677   Acceptable 2-OME-3-4-HSD- 1L          04-03-06             R0265677   Acceptable 19
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI.
COMMERCIAL SERVICE DATE 7-1-1978 Snubber Functional Tests Snubber No.              Test Date      Job Order No. Results    Remarks 2-GRC-S538                  04-18-06       R0098999  Accept. Small Bore Grinnell 2-GRC-S555                  04-19-06      R0099679  Accept. Small Bore Grinnell 2-GRC-S573                  04-20-06       R0036212  Accept. Small Bore Grinnell 2-GRC-S611                  04-19-06       R0036210  Accept. Small Bore Grinnell 2-GBD-S568                  04-20-06      R0037674  Accept. Small Bore Grinnell 2-GCCW-S843                  04-17-06       R0037685    Accept. Small Bore Grinnell 2-AFW-S4032-U                04-20-06       R0036689  Accept. Small Bore Grinnell 2-OME-3-4-HSD-IL            04-08-06       R0078801    Accept. Large Bore 2-OME-3-4-HSD-1U            04-07-06       R0100166    Accept. Large Bore 2-OME-3-4-HSD-3L            04-09-06       R0037382    Accept. Large Bore 2-OME-3-4-HSD-3U            04-08-06       R0058565  Accept. Large Bore The minimum 14% required sample size consists of 7 small bore (Grinnell) and 3 large bore (Steam Generator) snubbers.
20
 
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 6 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR ASME SECTION XI, SUBSECTIONS IWE AND IWL Containment Inservice Inspections During the reporting period of November 10, 2004, to May 4, 2006, inservice inspections were performed on the Unit 2 Containment pressure retaining structure in accordance with Subsections IWE and IWL of ASME Section XI, 1992 Edition and 1992 Addenda, and 10 CFR 50.55a.
The following attachment provides a listing of the examinations performed, results, and corrective actions, if any were performed. A General Visual Examination was performed on all accessible surfaces of the Containment liner along with examinations performed in conjunction with coating repairs, and other repair/replacement activities.
An acceptance criteria providing the acceptable minimum thickness of the containment liner was established for the examination of the concrete-backed liner. The examination results were compared to the acceptance criteria. All results were within the established acceptance criteria. No areas required to be classified as an Augmented Examination area in accordance with IWE-1240.
Containment concrete examinations are currently in progress as of this report date. No degradation has been found that impacts the structural integrity of the containment concrete. As of this report date, there have been no conditions noted in accessible areas that could indicate the presence or result in degradation to inaccessible areas.
21
 
Program Owner: (14,,.          2A,                             NIS-1 Attachment 7                                Evaluation of IWE As-Found Condition Examination Results Date: _'-0--o0:,
3125/2006        2    KuzLUI_          ,cones /-    -1u/*,(paaZ-b14-lIA, z-1 Z-1 ZA      (uenerai                None 03                                  (partial)                        Visual _______________
Accept
_________
3/25/2006        2    R0246391-          Moisture Barrier 2-598-MB (RCDT Area)              VT-3 3/25/200612        02 02                                                                            ______________ None                          Accept General'                None                          Accept 3252006          2    R0246391-            Zones 2-598-26, 2-598-27 (partial)              Visual                  NoneAccept R0266500al 3/2612006        2    R0266500-          Penetration Bolting 2-CPN-80-BOLTING                VT-1                  None 49                                                                                                                          Accept 3126/2006       2   R0266500-         Penetration Bolting 2-CPN-57-BOLTING              VT-1
_________48                                                                                                    None                           Accept Prior to coating repair: Liner and penetrations between fence at RCDT to Col. 21 and from 3/28/2006             05132069-       floor up approx. 3' and penetrations up to the 01              2nd weld channel (areas of damaged paint).            VT-3                   None                           Accept Areas between Cols. 21 and 23 and from the floor up to the 2nd weld channel including penetrations (areas of damaged paint)..
05132069-      Prior to coating repair: Zone 2-598-27 (partial)                 Four small areas, approx. 112" 3/30/2006        2   07            from gate at Col. 27 to concrete, floor elevation        VT-3    diameter with chipped top coat.              Accept up approx. 9'-0".                                  No base metal wastage.
3/30/2006       2   R0246391-         Moisture Barrier 2-598-MB (Annulus area)             VT-3                   None 1 04         1-             .                                       I                                                         Accept I                 I
    *    


==References:==
==References:==
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 22 Program Owner:_ q&. a A ." NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date: 7-Jo-Oh 3/31/2006 2 05132069-05 r-lI L.u IU 191 dII U -0u. LUIU 4-0 14-4-, r-L. OVU down to EL. 642', 10'-0" east of divider barrier seal. Zone 2-612-25B EL. 642' down to EL.627', 12'-0" east of divider barrier seal. Zone 2-612-25A EL. 627' down to EL. 612', 12'-0" divider barrier seal to Column 26. Zone 2-612-26A EL. 612' up to approx. EL. 622' from Column 26 to 27. Zone 2-612-27A EL. 612' up to approx. EL. 622' from column 27 to divider barrier seal. Zone 2-612-1 EL. 612' up to EL.637' from divider barrier seal to Column 1. Zone 2-612-28A.
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 22
Zone 2-612-28B EL. 627' to EL.637'.VT-3 Peeling paint, delamination of top coat, discoloration.
 
No liner plate degradation noted.Accept I I I I I I*  
Program Owner:_ q&.       a   A         ."                     NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date: 7-Jo-Oh r-lI     L.u IU UA:LIII*
191 U dII   LUIU
                                                                -0u. 4-0 14-4-,   r-L. OVU down to EL. 642', 10'-0" east of divider barrier seal. Zone 2-612-25B EL. 642' down to EL.
627', 12'-0" east of divider barrier seal. Zone 2-612-25A EL. 627' down to EL. 612', 12'-0" 05132069-    divider barrier seal to Column 26. Zone 2-612-                     Peeling paint, delamination of 3/31/2006      2                      26A EL. 612' up to approx. EL. 622' from 05                                                                        VT-3  top coat, discoloration. No liner    Accept Column 26 to 27. Zone 2-612-27A EL. 612' up plate degradation noted.
to approx. EL. 622' from column 27 to divider barrier seal. Zone 2-612-1 EL. 612' up to EL.
637' from divider barrier seal to Column 1. Zone 2-612-28A. Zone 2-612-28B EL. 627' to EL.
637'.                         I I
I I
I I
    *  


==References:==
==References:==
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 23 Program Owner: NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_7 4- , 3131/2006 2 R0246391-04/-ones,-598-6, 2-598-7, 2-598-8, 2-598-9, Z-598-5, 2-598-6, 2-598-7, 2-598-8, 2-598-9, 2-598-10, 2-598-11, 2-598-12, 2-598-13, 2-598-14, 2-598-15, 2-598-16, 2-598-17, 2-598-18, 2-598-19, 2-598-20, 2-598-21, 2-598-22, 2-598-23, 2-598-24, 2-598-25, 2-598-27 (partial), 2-612-2, 2-612-3, 2-612-4, 2-612-5, 2-612-6, 2-612-7, 2-612-8, 2-612-9, 2-612-101B, 2-612-11 B, 2-612-12A, 2-612-122B, 2-612-13A, 2-612-13B, 2-612-14A, 2-612-14B, 2-612-15A, 2-612-15B, 2-612-16, 2-612-17, 2-612-18, 2-612-19, 2-612-20, 2-612-21, 2-612-22,2-612-23, 2-612-24, 2-612-25A, 2-612-25B, 2-612-25C, 2-612-26A, 2-612-26B, 2-612-26C, 2-612-27A, 2-612-27B, 2-612-27C, 2-612-28A, 2-612-28B, 2-612-1, 2-650-1A, 2-650-11B, 2-650-1C, 2-650-2A, 2-650-2B, 2-6.50-2C, 2-650-3A, 2-650-3B, 2-650-3C, 2-650-4, 2-715-IA, 2-715-1B, 2-715-IC, 2-715-2A, 2-715-2B, 2-715-3, 2-745-001, 2-757-001, Inspection Ports: 2-PORT-01, 2-PORT-02, 2-PORT-03 General Visual Discoloration noted. No evidence of degradation that may affect either containment structural integrity or leak tightness.
1)NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 23
Accept 4(5/2006 05132069-Prior to paint removal: Instrument Room EL. Slight flaking and discoloration.
 
03 627' to ceiling and Azimuth 262 to divider VT-3 No liner degradation noted. Accept barrier seal.Prior to coatings removal: Containment Penetration 2-CPN-4 at first weld towards 4/512006 2 R0257113-containment from the #1 cooler to the radius VT-3 Slight discoloration.
Program Owner:                                         NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_ 7 4- ,
Accept 02 transition at the pipe end. Area of inspection edge of the toe of the welds described above.*  
                                /-ones,-598-6, 2-598-7, 2-598-8, 2-598-9, Z-598-5, 2-598-6, 2-598-7, 2-598-8, 2-598-9, 2-598-10, 2-598-11, 2-598-12, 2-598-13, 2-598-14, 2-598-15, 2-598-16, 2-598-17, 2-598-18, 2-598-19, 2-598-20, 2-598-21, 2-598-22, 2-598-23, 2-598-24, 2-598-25, 2-598-27 (partial), 2-612-2, 2-612-3, 2-612-4, 2-612-5, 2-612-6, 2-612-7, 2-612-8, 2-612-9, 2-612-101B, 2-612-11 B, 2-612-12A, 2-612-122B, 2-612-13A, 2-612-13B, Discoloration noted. No evidence R0246391-  2-612-14A, 2-612-14B, 2-612-15A, 2-612-15B, 3131/2006    2 04        2-612-16, 2-612-17, 2-612-18, 2-612-19, 2-612- General        of degradation that may affect Accept 20, 2-612-21, 2-612-22,2-612-23, 2-612-24, 2-       Visual  either containment structural 612-25A, 2-612-25B, 2-612-25C, 2-612-26A, 2-                   integrity or leak tightness.
612-26B, 2-612-26C, 2-612-27A, 2-612-27B, 2-612-27C, 2-612-28A, 2-612-28B, 2-612-1, 2-650-1A, 2-650-11B, 2-650-1C, 2-650-2A, 2-650-2B, 2-6.50-2C, 2-650-3A, 2-650-3B, 2-650-3C, 2-650-4, 2-715-IA, 2-715-1B, 2-715-IC, 2-715-2A, 2-715-2B, 2-715-3, 2-745-001, 2-757-001, Inspection Ports: 2-PORT-01, 2-PORT-02, 2-PORT-03 4(5/2006       05132069-     Prior 627'totopaint  removal: Instrument 03                       ceiling and Azimuth   262 toRoom  EL.
divider   VT-3   Slight flaking and discoloration.
No liner degradation noted.       Accept barrier seal.
Prior to coatings removal: Containment Penetration 2-CPN-4 at first weld towards 4/512006   2   R0257113-     containment from the #1 cooler to the radius       VT-3         Slight discoloration.       Accept 02           transition at the pipe end. Area of inspection edge of the toe of the welds described above.
      *  


==References:==
==References:==
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Rev. 0" 24 Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, ProgramO NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_7-C20...-c4, 4M7/2006 2 05132069-02 Prior to surface prep: Zones 2-612-20, 2-612-21 VT-3 Peeling paint, delamination, light discoloration, surface rust. No evidence of liner degradation.
1)NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 24
Accept Liner surfaces behind divider barrier seal when seal segment is removed: Zone 2-612-2 Seal sample #1, between Columns 2 -3, area approx. 3'-0" wide, 5'-0" high, starting approx. 8" No evidence of degradation that R0265946-up from seal. Existing gap of <114" wide with General may affect either containment 418/2006 2 06 internal obstructions prevent view of attachment Visual structural integrity or leak Accept weld. Zone 2-612-24 Seal sample #2, area tightness noted on viewable approx. 2'-0" wide, 2'-0" high, starting at surfaces.attachment weld. Existing gap of approx. 1/4" wide at one location with internal obstructions prevent view of surfaces Prior to paint removal: Zone 2-650-1A Liner Light discoloration.
 
No liner plate 4113/2006 2 05341030-plate surfaces surrounding the following Vr-3 or penetration surface Accept 03 penetrations, and penetration surfaces:
ProgramO                                                 NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_7-C20...-c4, 05132069-                                                                Peeling paint, delamination, light 4M7/2006     2               Prior to surface prep: Zones 2-612-20, 2-612-21       VT-3   discoloration, surface rust. No 02                                                                                                                Accept evidence of liner degradation.
2-CPN- degradation or wastage noted.56, 57, 65, 80, 83, 86... degradation or wastage noted Prior to coatings removal: Containment Penetration 2-CPN-2 at first weld towards 4/15/2006 2 R0257111-containment from the #1 cooler to the radius Discoloration and flaking. No 02 transition at the pipe end. Area of inspection VT-3 pisotration adakin no Accept 360 deg. Around penetration and 1/2" from the edge of the toe of the weld and transition described above.I*  
Liner surfaces behind divider barrier seal when seal segment is removed: Zone 2-612-2 Seal sample #1, between Columns 2 - 3, area approx. 3'-0" wide, 5'-0" high, starting approx. 8"           No evidence of degradation that R0265946-     up from seal. Existing gap of <114" wide with       General   may affect either containment 418/2006       2 06         internal obstructions prevent view of attachment       Visual     structural integrity or leak weld. Zone 2-612-24 Seal sample #2, area                                                           Accept tightness noted on viewable approx. 2'-0" wide, 2'-0" high, starting at                           surfaces.
attachment weld. Existing gap of approx. 1/4" wide at one location with internal obstructions prevent view of surfaces Prior to paint removal: Zone 2-650-1A Liner               Light discoloration. No liner plate 4113/2006     2   05341030-         plate surfaces surrounding the following         Vr-3 03         penetrations,   and penetration surfaces: 2-CPN-                   or penetration surface degradation                             Accept or wastage noted.
56, 57, 65, 80, 83, 86...                     degradation or wastage noted Prior to coatings removal: Containment Penetration 2-CPN-2 at first weld towards 4/15/2006     2   R0257111-     containment     frompipe the end.
                                                            #1 cooler to inspection the radius 02             transition at the             Area of               VT-3     Discoloration and flaking. No pisotration       adakin no             Accept 360 deg. Around penetration and 1/2" from the edge of the toe of the weld and transition described above.I
    *  


==References:==
==References:==
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 25 Program Owner:a NIS-1 Attachment Evaluation of WE As-Found Condition Examination Results Date:_7--o--  
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 25
, 4(15(2006 2 R0257114-02 rIuIi.v L '+luriys iwerijlvdii Penetration 2-CPN-5 at first weld towards containment from the #1 cooler to the radius transition at the pipe end. Area of inspection 360 deg. Around penetration and 1/2" from the edoe of the toe of the welds described above.VT-3 Slight discoloration.
 
No penetration degradation noted.Accept 4/22/2006 2 R0246T08-Outer and inner equalizing valves. VT-3 None Accept 2-AIRLOCK-C650 electrical penetration bolting 4124/2006 2 R0267461-for inner and outer doors, both sides. 2- VT-1 None Accept 02 UPLODE-BOLTING (16), 2-UPLIDE-BOLTING V I 1 1 (16)_*  
Program Owner:a                                         NIS-1 Attachment Evaluation of WE As-Found Condition Examination Results Date:_7--o-- ,
rIuIi.v L   '+luriys iwerijlvdii LjUILaIrlII*IrIL Penetration 2-CPN-5 at first weld towards 4(15(2006          R0257114-  containment from the #1 cooler to the radius 2                                                                                          Slight discoloration. No 02          transition at the pipe end. Area of inspection             VT-3                                          Accept penetration degradation noted.
360 deg. Around penetration and 1/2" from the edoe of the toe of the welds described above.
4/22/2006     2   R0246T08-         Outer and inner equalizing valves.                   VT-3                   None                   Accept 2-AIRLOCK-C650 electrical penetration bolting 4124/2006     2   R0267461-     for inner and outer doors, both sides. 2-02         UPLODE-BOLTING           (16), 2-UPLIDE-BOLTING             VT-1                    None                  Accept V
I     1           1                         (16)_
    *


==References:==
==References:==
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 26 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 7 ABSTRACT OF EXAMINATIONS, RESULTS AND CORRECTIVE ACTIONS FOR STEAM GENERATOR EDDY CURRENT EXAMINATIONS 2004 Steam Generator In-Service Inspections During October of 2004, eddy current inspections were conducted on the Unit 2 steam generators.
: 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 26
Based upon the favorable results of this inspection and in accordance with the provisions of Technical Specification 4.4.5.3a, the Unit 2 steam generators continue to be on an inspection interval of up to 40 calendar months. As such, the Unit 2 steam generators will next be inspected in the fall of 2007.27 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 8 NIS-2 REPAIR AND REPLACEMENT INDEX 28 U2C16 Repair Replacement Report Job Order R0099679-01 04305061-04 04318017-01 R0238854-13 R0266622-05 05340018-01 05340007-01 05340017-01 04322047-01 R0036212-01 R0098999-01 05340020-01 R0246231-01 R0036689-01 02346033-12 05336016-01 06013029-13 06040073-01 R0240871-01 04305061-28 04305061-27 R0226722-01 R0037674-01 05121006-01 05237040-17, 18,22,23,27,28 32,33,37,38,43 Description 2-GRC-$555, REPLACE SNUBBER 2-PP-50E, REPLACE PUMP W/ SS PUMP 2-MRV-232, REPAIR LEAK (INTERNALS, BIB BOLTING)2-VCR-20, REPLACE BONNET/BOLTING 2-SV-45A, REPLACE SAFETY VALVE 2-CS-536, REPLACE INTERNALS 2-CS-534, REPLACE INTERNALS 2-CS-535, REPLACE INTERNALS 2-OME-4, REPLACE MANWAY BOLTS 2-GRC-S573; REPLACE SNUBBER 2-GRC-S538, REPLACE SNUBBER 2-SI-210, REPLACE BOLTING 2-SV-104E, REPLACE BOLTING 2-AFW-S4032-U, REPLACE SNUBBER 2-MRV-223, REPLACE BOLTING 2-MRV-242, REPLACE INTERNALS 2-PP-50W, CUT/REPLACE PIPE WELD 2-PP-50W, REPLACED GLAND PLATE/BOLTING 2-CCR-457, REPLACE INTERNALS 2-PP-50E, INSTALL CCP SUCTION PIPING 2-PP-50E, INSTALL CCP DISCHARGE PIPING 2-SV-104W, REPLACE VALVE AND BOLTING 2-GBD-S568, REPLACE SNUBBER 2-NRV-153, REPLACE INTERNALS 2-OME-4, WELDED PREEMPTIVE WELD OVERLAYS ON DISSIMILAR METAL WELDS ON SAFETY, RELIEF, SPRAY, AND SURGE NOZZLES Component Code Class 2-GRC-$555 1 2-PP-50E 2 2-MRV-232 2 2-VCR-20 2 2-SV-45A I 2-CS-536 2 2-CS-534 2 2-CS-535 2 2-OME-4 1 2-GRC-$573 1 2-GRC-$538 1 2-SI-210 2 2-SV-104E 2 2-AFW-S4032-U 2 2-MRV-223 2 2-MRV-242 2 2-PP-50W 2 2-PP-50W 2 2-CCR-457 2 2-PP-50E 2 2-PP-50E 2 2-SV-104W 2 2-GBD-S568 2 2-NRV-153 1 2-OME-4 1 29 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 9 NIS-2 REPAIR AND REPLACEMENT REPORTS 30 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne, IN 46801 Date 04/19/08 Sheet 1 of 2 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridngman, MI 49106 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place, Bridclman.
 
MI 49106 Unit 2 Component 2-GRC-S555 JOB ORDER No. R0099679-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Address 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, P0) ed (Yes or No)2-GRC-$555 SNUBBER GRINNELL M&E 30-024683 N/A S/N 33021 N/A Replacement NO ASP 30610 SEAL KIT GRINNELL M&E 30-025055 N/A N/A N/A Replacement NO ASP 30463"A" SEAL KIT GRINNELL M&E 30-040590 N/A NIA N/A Replacement NO ASP 28096 PISTON BUSHING GRINNELL M&E 30-024790 N/A NIA N/A Replacement NO ASP 16978 7. Description of Work REPLACED SNUBBER WITH REBUILT 8. Test Conducted:
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 7 ABSTRACT OF EXAMINATIONS, RESULTS AND CORRECTIVE ACTIONS FOR STEAM GENERATOR EDDY CURRENT EXAMINATIONS 2004 Steam Generator In-Service Inspections During October of 2004, eddy current inspections were conducted on the Unit 2 steam generators. Based upon the favorable results of this inspection and in accordance with the provisions of Technical Specification 4.4.5.3a, the Unit 2 steam generators continue to be on an inspection interval of up to 40 calendar months. As such, the Unit 2 steam generators will next be inspected in the fall of 2007.
Hydrostatic D Pneumatic
27
[] Nominal Operating Pressure D Other nX VT-3 Pressure NIA psi. Test Temp. NIA F 31 INI T Page 2 of 2 FORM NIS-2 (Back)Job Order/File R0099679-01
 
: 9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rules of the ASME Code, Section XN .REPLAC EMENT conforms to the repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A n4l')&#xfd;Signed Maintenance Weldina Supervisor Date 0 ,2O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS -h ve Inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has p&rforrned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in ankynanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspejtioit./
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 8 NIS-2 REPAIR AND REPLACEMENT INDEX 28
imissions Af/ 6e76rV7-f j.ctor's Signalure ,/,/,gZ- 20Q6 National Board, State, Province, and Endorsements 3a-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne, IN 46801 Address Date 04/14/06 Sheet I of 2 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place. Bridqman, MI 49106 Unit 2 Component 2-PP-50E JOB ORDER No. 04305061-04 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place. Bridaman.
 
MI 49106 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Address 4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2 5. (a) Applicable Const. Code ASME SEC III CL2 1986 Ed, N/A Add. Code Case.(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989,. No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-PP-50E PUMP N/A M&E 30-014849 NA ASME SA1 82 N/A REPLACED YES CASING ASP 31062 TP304 7. Description of Work REPLACED PUMP 8. Test Conducted:
U2C16 RepairReplacementReport Job Order     Description                                      Component  Code Class R0099679-01   2-GRC-$555, REPLACE SNUBBER                      2-GRC-$555      1 04305061-04  2-PP-50E, REPLACE PUMP W/ SS PUMP                2-PP-50E        2 04318017-01   2-MRV-232, REPAIR LEAK (INTERNALS, BIB BOLTING)  2-MRV-232      2 R0238854-13   2-VCR-20, REPLACE BONNET/BOLTING                2-VCR-20        2 R0266622-05  2-SV-45A, REPLACE SAFETY VALVE                  2-SV-45A        I 05340018-01   2-CS-536, REPLACE INTERNALS                      2-CS-536        2 05340007-01  2-CS-534, REPLACE INTERNALS                      2-CS-534        2 05340017-01  2-CS-535, REPLACE INTERNALS                     2-CS-535        2 04322047-01  2-OME-4, REPLACE MANWAY BOLTS                   2-OME-4          1 R0036212-01  2-GRC-S573; REPLACE SNUBBER                     2-GRC-$573      1 R0098999-01  2-GRC-S538, REPLACE SNUBBER                     2-GRC-$538      1 05340020-01  2-SI-210, REPLACE BOLTING                       2-SI-210        2 R0246231-01  2-SV-104E, REPLACE BOLTING                       2-SV-104E      2 R0036689-01  2-AFW-S4032-U, REPLACE SNUBBER                 2-AFW-S4032-U    2 02346033-12  2-MRV-223, REPLACE BOLTING                       2-MRV-223      2 05336016-01  2-MRV-242, REPLACE INTERNALS                     2-MRV-242      2 06013029-13  2-PP-50W, CUT/REPLACE PIPE WELD                 2-PP-50W        2 06040073-01  2-PP-50W, REPLACED GLAND PLATE/BOLTING           2-PP-50W        2 R0240871-01  2-CCR-457, REPLACE INTERNALS                     2-CCR-457      2 04305061-28  2-PP-50E, INSTALL CCP SUCTION PIPING             2-PP-50E        2 04305061-27  2-PP-50E, INSTALL CCP DISCHARGE PIPING           2-PP-50E        2 R0226722-01  2-SV-104W, REPLACE VALVE AND BOLTING             2-SV-104W      2 R0037674-01  2-GBD-S568, REPLACE SNUBBER                     2-GBD-S568      2 05121006-01  2-NRV-153, REPLACE INTERNALS                     2-NRV-153        1 05237040-17,  2-OME-4, WELDED PREEMPTIVE WELD OVERLAYS         2-OME-4          1 18,22,23,27,28 ON DISSIMILAR METAL WELDS ON SAFETY, RELIEF, 32,33,37,38,43 SPRAY, AND SURGE NOZZLES 29
Hydrostatic F-- Pneumatic 1 Other F INSERVICE VT-2 Nominal Operating Pressure Pressure psi. Test Temp. _ F-33 Page 2 of 2 FORM KIS-2 (Back)Job Order/File 04305061-04
 
: 9. Remarks: Inservice VT-2 performed.
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 9 NIS-2 REPAIR AND REPLACEMENT REPORTS 30
Applicable Manufacturer's Data Reports to be attached Serial# 05RLCA0321501001 DWG. 017571 Model2.5"RLIJ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Dew ne Trmns Mainter Owner or Owner's Designee, Title tance Welding Supervisor Date __ /04 05_,204 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS / .have inspected the components described in this Owner's Report during the period .5// '? to .I and state that to the best of my knowledge and belief, the Owner hali perlormed; examinations'and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable inmny manner for any personal injury or properly damage or a loss of any kind arising from or connected with this =r.i.Inspec--or Signf lur Date 20 Commissions AI.6 6e77 iff/':S/A7 r"'National Board, 9tafe, Province, and Endorsements 3,-I FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section Ill, Division 1 2 Pg. I of.. "" "" I. Manufacired and
 
-'ve Pump Division, Nuclear Products Operation 2300 E. Vnmon Ave. Vernon, CA 90)05 (name and address of N Certificate Holder)2. Manufactured forAmerican Elctric Power, Material Center,9970 Red Arrow ighwayBridgan,M].
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
49106 Irama and address of Purchased 3. Location of C Electric Power, D.C. Cook Plan4, 0;Cook .Pate, Bnidgman, M 60450 (name and address)4. Model No., Series No., or Type 2.5"RL Drawing DWG17571 B CRN A 1986 W86 2 NA 5. ASME Code, Section 111, Division 1: fedition) laddende date) (class) (Code Case no.)6. Pump or valve Pump Nominal Inlet size " Outlet size 3 1/8" (in.) (in.)7. Material:
: 1. Owner      AMERICAN ELECTRIC POWER                          Date      04/19/08 Name P.O. Box 60 Fort Wayne, IN 46801                                    Sheet    1        of  2 Address
Body NBonnet NA Disk NA BoNAtng NA[a)Cert.H.older's Serial No.05RLCA0321501001 (b) Ic)Nat'l Body Board., .Serial No. No.NA NA Id)Bonnet serial No.NA le)Disk Serial No.NA Supplemental information In form of lists. sketches.
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                  Unit  2   Component    2-GRC-S555 Name One Cook Place, Bridngman, MI 49106                                  JOB ORDER No. R0099679-01 Address                                              Repair Org. P.O. No., Job No., etc
or drawings may be used provided (1) size is BY& X 11. (2) Information in itein'1 through 4 on this Data Report Is Included on each sheet. (3) each sheet is numbored and the number of sheetss rencorded at the top of this form'(1.2188)This form (EDD0371 may be obtained from the Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield.
: 3. Work Performed by AEP/D.C. COOK Maint. Department                      Type Code Symbol Stamp N/A Name                                      Authorization No.      N/A One Cook Place, Bridclman. MI 49106                                  Expiration Date      N/A Address
NJ 07007-2300.
: 4. Identification of System:  REACTOR COOLANT SYSTEM              ISI CLASS 1
REPRINT GM I*.-. -z ---~ ., , 0351)
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
.,_ = -o. ..... .............
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of        Manufacturer      National      Other          Year        Repaired,       ASME Component          Manufacturer        Serial No.       Board Identification        Built      Replaced,       Code (Material M&E,       No.                                 or Replacement    Stamp ASP, P0)                                                                    ed (Yes or No) 2-GRC-$555 SNUBBER            GRINNELL      M&E 30-024683          N/A     S/N 33021        N/A       Replacement        NO ASP 30610 SEAL KIT          GRINNELL      M&E 30-025055          N/A         N/A           N/A       Replacement        NO ASP 30463 "A" SEAL KIT          GRINNELL      M&E 30-040590        N/A          NIA            N/A      Replacement       NO ASP 28096 PISTON BUSHING            GRINNELL      M&E 30-024790        N/A          NIA            N/A      Replacement       NO ASP 16978
FFORM NPV-1. (Back -Pg. 2 of. O A21 Certificate Holder's Serial No. 05LA0321501001
: 7.      Description of Work REPLACED SNUBBER WITH REBUILT
: 8. Design cond'citions psi 300 IF or valve pressure class NA (1l ltemperature)
: 8. Test Conducted: Hydrostatic D        Pneumatic []      Nominal Operating Pressure    D Other nX        VT-3            Pressure      NIA  psi. Test Temp.      NIA    F INI  T 31
: 9. Cold workInj'-ssjre NA psi at i"OOF 10. Hykirostatic test 52601400 psL Disk differential test pressure NA psi 11. Remark.. Namplate attacbed by dCive pis.Job Number: RLCA03215 Prodaction Order: RLSA08607* D 'i:CERTIFICATION OF DESIGN Design Specification certified by AlbeTt John Wettlaufer P.E. State PA Reg. no. 13335-E Design Report certified by D. G. Bowman P.E. State CA Reg. no. NA CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section III, Division 1.N Certificate of Authorization No N1 4130 JeIres Jte] 0, 2008 D 321/o6 -erv Pump Division, Nuclear Products Ope- ed IN Certificate Holderd (aUt.ot re.........e CERTIFICATE OF INSPECTION I. the undersigned, holding a valid'commission issued by the National Board of Boiler and Pressure Vessel Inspectc;rs and the State or Province of Caffoania and employed by HSB-CT of Har-forL CT' have inspectea the pump, or valve, described in this Data Report on 32121/2006 , and state that to the best of my knowledge and belief. 1ie Certificate Holder has corn structed this purrp*.or valve, in accordance with the ASME Code, Section IIl, Division 1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or ss of any kind arising from or connected with this Inspection.
 
Date 3/21/2006 Signed ..OCommissions CA 1969 (Authorized Int ector) lNatL Betd. rind. andorsemerits) and Suite or proy. and no.](1) For manually operated valves only.SIMP REVIEWiED AND ACCEPTED .DA 15 10 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne, IN 46801 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place. Bridaman.
Page 2 of 2 FORM NIS-2      (Back)
Ml 49106 Date Sheet I 04/22106 of 2 Unit 2 Component 2-MRV-232 JOB ORDER No. 04318017-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Address 4. Identification of System: MAIN STEAM SYSTEM ISI CLASS 2 5. (a) Applicable Const. Code ANSI-B31.1  
Job Order/File R0099679-01
-1983 NIA Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-MRV-232 STEM N/A M&E 30-688864 N/A ASTM A276 N/A REPLACED NO ASP 28532 TP 316 PLUG N/A M&E 30-688864 N/A ASTM A582 N/A REPLACED NO ASP 28532 TP 416 CAGE N/A M&E 30-688865 N/A ASTM A747 N/A REPLACED NO ASP 17265 CB7CU-11/2" STUD M&E 30-688868 N/A ASTM A193 N/A REPLACED NO MATERIAL ASP 28601 GR B71/2" NUT M&E 30-688869 N/A ASTM A194 N/A REPLACED NO ASP 28601 GR2H 7. Description of Work REPLACED STEM, PLUG AND BONNET BOLTING 8. Test Conducted:
: 9. Remarks:                VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLAC EMENT            conforms to the rules of the ASME Code, Section XN.                                                          repair or replacement Type Code Symbol Stamp          N/A Certificate of Authorization No.      N/A     Expiration Date      N/A Signed n4l')&#xfd;          Maintenance Weldina Supervisor          Date                        0
Hydrostatic s1 Pneumatic
                                                                                                                ,2O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Michiqan          and employed by ABS GROUP INC.                                         of HOUSTON, TEXAS                                  -                       h ve Inspected the components described in this Owner's Report during the period                                  to     6*/,,24'-,                , and state that to the best of my knowledge and belief, the Owner has p&rforrned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
] Nominal Operating Pressure Other __Pressure psi. Test Temp. _ F 37'NIT-4 Page 2 of 2 FORM NIS-2 (Back)Job OrderlFile 04318017-01
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in ankynanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspejtioit./
: 9. Remarks:.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT the ASME Code, Section XI. repair or replacement conforms to the rules of Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA&#xfd; hievrIM4 VDIPTI_&#xfd;Signed Maintenance Welding Supervisor Date P " 20 i r Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period ____ ______to ...--/,. and state that to the best of my knowledge and belief, the Owner has performed examinations 6nd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti*Commissions X18 Inspedor's Signature' Date__ _ _National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Date 04/17/06 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Address 3. Work Performed by AEPID.C. COOK Maint. Department Name One Cook Place, Bridqman, MI 49106 Address Unit 2 Component 2-VCR-20 JOB ORDER No. R0238854-13 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. Identification of System: ICE CONDENSER SYSTEM ISI CLASS 2 5. (a) Applicable Const. Code ANSI-B31.1
j imissions                    Af/   6e76rV7-f
-1983 Add. Code Case N-522 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-VCR-20 VALVE BONNET N/A M&E 30-039707 NA ASTM A445 N/A REPLACED NO ASP 31147 66T/2k NUT N/A M&E 30-212070 NA ASME SA194, N/A REPLACED NO ASP 22002 GR 8F Y2' STUD N/A M&E 30-040599 NA ASME SA 453 N/A REPLACED NO MATERIAL ASP 27052 GR 660 7. Description of Work REPLACED BONNET ASSY AND BOLTING.8. Test Conducted:
        .ctor's Signalure                                                National Board, State, Province, and Endorsements
Hydrostatic D Pneumatic D Other D APPENDIX J TEST PER CC N-522 Nominal Operating Pressure D-]Pressure psi. Test Temp. F 3q IN~F~
            ,/,/,gZ- 20Q6 3a-
Page 2 of 2 FORM4 NIS-2 (Back)Job Order/File R0238854-13
 
: 9. Remarks: APPENDIX J TEST PER CC N-522 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A TThwavn~ Maintet Signed niance Weldino Supervisor Date 2 20 4-d5 V-'e4 &#xfd; r&#xfd;M rin v;a v n ?e--Tri ons aintenance Welding SUDervisor Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS , / bave inspected the components described in this Owner's Report during the period to ,and state that to the best of my knowledge and belief, the Owner trs p6rformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and ffective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be lia n any manner for any personal injury or property damage or a loss of any kind arising from or connected with th s ction.Commissionsjf 9 , qw National Board, 1 State, Province, and Endorsements 9/0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Date 04/14106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bddcman. MI 49106 Unit 2 Component 2-SV-45A JOB ORDER No. R0266622-05 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place, Bridgman, MI 49106 Address Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed. N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of. Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-SV-45A SAFETY VALVE CROSBY M&E 30-036392 NA S/N N/A REPLACED NO ASP 30673 RV-1-8010A
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 7. Description of Work REPLACED VALVE 8. Test Conducted:
: 1. Owner       AMERICAN ELECTRIC POWER                                              Date        04/14/06 Name P.O. Box 60 Fort Wayne, IN 46801                                      Sheet      I          of 2 Address
Hydrostatic D Pneumatic.t.. .hOher- VT-2 at NOP/NOT, VT-3 Nominal Operating Pressure Pressure psi. Test Temp. F i7-/
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                      Unit 2      Component        2-PP-50E Name One Cook Place. Bridqman, MI 49106                                      JOB ORDER No. 04305061-04 Address                                                Repair Org. P.O. No., Job No., etc
Page 2 of 2 FORM NIS-2 (Back)Job Order/File R0266622-05
: 3. Work Performed by AEP/D.C. COOK Maint. Department                      Type Code Symbol Stamp N/A Name                                   Authorization No.         N/A One Cook Place. Bridaman. MI 49106                                     Expiration Date          N/A Address
: 9. Remarks: NOP/NOT VT-2 performed.
: 4. Identification of System:      EMERGENCY CORE COOLING SYSTEM                          ISI CLASS 2
VT-3 on internals Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp NONE conforms to the rules of Certificate of Authorization No. NIA Expiration Date N/A Signed mons Maintenance Weldina Suoervisor Date ,20 6" r I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period Z/, to ,Z/,ll/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
: 5. (a) Applicable Const. Code ASME SEC III CL2 1986 Ed, N/A                  Add. Code Case.
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989,. No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of          Manufacturer    National        Other            Year        Repaired,   ASME Component          Manufacturer        Serial No.       Board      Identification        Built        Replaced,   Code (Material M&E,      No.                                       or Replacement Stamped ASP, PO)                                                                    (Yes or No) 2-PP-50E PUMP                  N/A        M&E 30-014849        NA      ASME SA1 82            N/A       REPLACED      YES CASING                              ASP 31062                      TP304
: 7. Description of Work REPLACED PUMP
: 8. Test Conducted: Hydrostatic F--        Pneumatic    1    Nominal Operating Pressure Other  F        INSERVICE VT-2                         Pressure                psi. Test Temp.         _      F
                                                      -33
 
Page 2 of 2 FORM KIS-2 (Back)
Job Order/File          04305061-04
: 9. Remarks:          Inservice VT-2 performed.
Applicable Manufacturer's Data Reports to be attached Serial# 05RLCA0321501001            DWG. 017571 Model2.5"RLIJ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT            conforms to the rules of the ASME Code, Section XI.                                                           repair or replacement Type Code Symbol Stamp            NONE Certificate of Authorization No.     N/A      Expiration Date      N/A Signed    Dew ne Trmns                  Mainter tance Welding Supervisor            Date __/04      05_,204 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Michigan          and employed by ABS GROUP INC.                                             of HOUSTON, TEXAS                                  /   .                     have inspected the components described in this Owner's Report during the period                            '?      to     .5// . I                  and state that to the best of my knowledge and belief, the Owner hali perlormed; examinations'and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable inmny manner for any personal injury or properly damage or a loss of any kind arising from or connected with this        =r.i.
Commissions AI.6 6e77                    iff/   ':S/A7 r"'
National Board, 9tafe, Province, and Endorsements Inspec--or Signf lur Date                  20 3,-I
 
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
As Required by the Provisions of the ASME Code, Section Ill, Division 1                                                        2 Pg. I of..          "" ""
I. Manufacired and certifie*            -'ve Pump Division, Nuclear Products Operation 2300 E. Vnmon Ave. Vernon, CA 90)05 (name and address of NCertificate Holder)
: 2. Manufactured forAmerican Elctric Power, Material Center,9970 Red Arrow ighwayBridgan,M]. 49106 Irama and address of Purchased Electric Power,    D.C. Cook Plan4, 0;Cook .Pate,Bnidgman, M 60450
: 3. Location of C (name and address)
: 4. Model No., Series No., or Type 2.5"RL                        Drawing      DWG17571                              B              CRN          A 1986                      W86                        2                                NA
: 5. ASME Code, Section 111,Division 1:
fedition)              laddende date)               (class)                   (Code Case no.)
Nominal Inlet size                "          Outlet size              3 1/8"
: 6. Pump or valve              Pump (in.)                                    (in.)
NA                  Disk          NA                BoNAtng                  NA
: 7. Material:    Body            NBonnet
[a)                            (b)                          Ic)                          Id)                                    le)
Cert.                          Nat'l                        Body                        Bonnet                                  Disk H.older's                        Board.,                     . Serial                        serial                                Serial Serial No.                        No.                          No.                            No.                                  No.
05RLCA0321501001                        NA                          NA                              NA                                    NA Supplemental information In form of lists. sketches. or drawings may be used provided (1) size is BY& X 11. (2) Information in itein'1 through 4 on this Data Report Is Included on each sheet. (3) each sheet is numbored and the number of sheetss rencorded at the top of this form' (1.2188)         This form (EDD0371 may be obtained from the Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300.                     REPRINT GM I
                                                                                                                    *.-.          -z  ---
                                                                                                                            ~      ., ,
0351)
 
        .,_ =.  ....
              -o.      .............                 FFORM NPV-1. (Back - Pg. 2 of.                                                O      A21 Certificate Holder's Serial No. 05LA0321501001
: 8. Design cond'citions          *f                      psi        300                IF or valve pressure class                    NA        (1l (prea*srel                      ltemperature)
: 9. Cold workInj'-ssjre                        NA            psi at i"OOF
: 10. Hykirostatic test            52601400        psL  Disk differential test pressure                NA                                      psi
: 11. Remark..           Namplate attacbed by dCive pis.
Job Number: RLCA03215 Prodaction Order: RLSA08607
* D                'i:CERTIFICATION                                            OF DESIGN Design Specification certified by            AlbeTt John Wettlaufer                P.E. State          PA        Reg. no.     13335-E Design Report certified by              D. G. Bowman                              P.E. State          CA        Reg. no.     NA CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section III, Division 1.
N Certificate of Authorization No                    N14130                                                          JeIres Jte]      0, 2008 D          321/o6            -  erv Pump Division, Nuclear Products Ope-                  ed IN Certificate Holderd                                  (aUt.ot re.........e CERTIFICATE OF INSPECTION I. the undersigned, holding a valid'commission issued by the National Board of Boiler and Pressure Vessel Inspectc;rs and the State or Province of            Caffoania                                    and employed by HSB-CT of         Har-forL CT'                                               have inspectea the pump, or valve, described in this Data Report on 32121/2006                    , and state that to the best of my knowledge and belief. 1ie Certificate Holder has corn structed this purrp*.or valve, in accordance with the ASME Code, Section IIl, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or              ss of any kind arising from or connected with this Inspection.
Date    3/21/2006 Signed              .. OCommissions (Authorized Int ector)
CA 1969 rind. andorsemerits) and Suite or proy. and no.]
lNatL Betd.
(1) For manually operated valves only.
SIMP REVIEWiED AND ACCEPTED                                        .
DA 15 10
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner        AMERICAN ELECTRIC POWER                                                Date        04/22106 Name P.O. Box 60 Fort Wayne, IN 46801                                          Sheet    I          of   2 Address
: 2.      Plant D.C. COOK NUCLEAR POWER PLANT                                        Unit    2  Component        2-MRV-232 Name One Cook Place, Bridgman, MI 49106                                        JOB ORDER No. 04318017-01 Address                                                Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                          Type Code Symbol Stamp N/A Name                                    Authorization No.         N/A One Cook Place. Bridaman. Ml 49106                                        Expiration Date        N/A Address
: 4. Identification of System:        MAIN STEAM SYSTEM                ISI CLASS 2
: 5. (a) Applicable Const. Code ANSI-B31.1 - 1983                NIA Add.      Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of                Name of        Manufacturer    National        Other            Year        Repaired,        ASME Component            Manufacturer        Serial No.       Board      Identification      Built        Replaced,        Code (Material M&E,      No.                                     or Replacement    Stamped ASP, PO)                                                                        (Yes or No) 2-MRV-232 STEM                    N/A          M&E 30-688864      N/A        ASTM A276            N/A        REPLACED            NO ASP 28532                      TP 316 PLUG                    N/A          M&E 30-688864      N/A       ASTM A582            N/A       REPLACED            NO ASP 28532                      TP 416 CAGE                    N/A         M&E 30-688865        N/A      ASTM A747            N/A      REPLACED            NO ASP 17265                      CB7CU-1 1/2" STUD                                M&E 30-688868        N/A      ASTM A193            N/A      REPLACED            NO MATERIAL                                  ASP 28601                      GR B7 1/2" NUT                                M&E 30-688869        N/A       ASTM A194            N/A       REPLACED           NO ASP 28601                      GR2H
: 7.      Description of Work REPLACED STEM, PLUG AND BONNET BOLTING
: 8. Test Conducted: Hydrostatic            s1 Pneumatic    ]      Nominal Operating Pressure Other        __Pressure                                                    psi. Test Temp.        _      F 37
                                                                                                                            'NIT-4
 
Page 2 of 2 FORM NIS-2       (Back)
Job OrderlFile 04318017-01
: 9. Remarks:.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT              conforms to the rules of the ASME Code, Section XI.                                                           repair or replacement Type Code Symbol Stamp          NONE Certificate of Authorization No.     NIA      Expiration Date      NIA Signed    &#xfd;hievrIM4VDIPTI_&#xfd; Owner or Owner's Designee, Title Maintenance Welding Supervisor              Date          r P  "        20 i CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of             Michigan          and employed by ABS GROUP INC.                                                of HOUSTON, TEXAS                                                                have inspected the components described in this Owner's Report during the period ____ ______to                              ...--      /,.                and state that to the best of my knowledge and belief, the Owner has performed examinations 6nd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti
                                *Commissions                               X18 Inspedor's Signature'       "*L___.                                      National Board, State, Province, and Endorsements Date__                        _  _
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner       AMERICAN ELECTRIC POWER                                               Date       04/17/06 Name P.O. Box 60 Fort Wayne. IN 46801                                       Sheet     1         of 2 Address
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                     Unit    2  Component        2-VCR-20 Name One Cook Place, Bridgman, MI 49106                                     JOB ORDER No. R0238854-13 Address                                               Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEPID.C. COOK Maint. Department                        Type Code Symbol Stamp N/A Name                                     Authorization No.        N/A One Cook Place, Bridqman, MI 49106                                     Expiration Date          N/A Address
: 4. Identification of System:      ICE CONDENSER SYSTEM                  ISI CLASS 2
: 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add.                 Code Case N-522 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of          Manufacturer    National        Other            Year        Repaired,       ASME Component          Manufacturer        Serial No.     Board      Identification        Built        Replaced,       Code (Material M&E,      No.                                       or Replacement    Stamped ASP, PO)                                                                      (Yes or No) 2-VCR-20 VALVE BONNET                N/A         M&E 30-039707        NA        ASTM A445              N/A       REPLACED          NO ASP 31147                          66T
        /2k NUT              N/A          M&E 30-212070        NA      ASME SA194,             N/A        REPLACED          NO ASP 22002                      GR 8F Y2' STUD              N/A          M&E 30-040599        NA      ASME SA 453            N/A      REPLACED            NO MATERIAL                              ASP 27052                      GR 660
: 7. Description of Work REPLACED BONNET ASSY AND BOLTING.
: 8. Test Conducted: Hydrostatic D Pneumatic D                Nominal Operating Pressure        D-]
Other D        APPENDIX J TEST PER CC N-522                    Pressure              psi. Test Temp.                F 3q                                                  IN~F~
 
Page 2 of 2 FORM4 NIS-2 (Back)
Job Order/File        R0238854-13
: 9. Remarks:          APPENDIX J TEST PER CC N-522 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT            conforms to the rules of the ASME Code, Section X1.                                                           repair or replacement Type Code Symbol Stamp            NONE Certificate of Authorization No.       N/A        Expiration Date    N/A rin
                                      &#xfd; r&#xfd;M Signed    TThwavn~                        Maintet niance Weldino Supervisor          Date                          220 4-d5 onsDesignee, aintenance Title        Welding SUDervisor v or Ownerv;a n Owner's
                    ?e--Tri V-'e4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of             MichiQan            and employed by ABS GROUP INC.                                           of HOUSTON, TEXAS                                  ,    /                     bave inspected the components described in this Owner's Report during the period                                      to                                ,and state that to the best of my knowledge      and belief, the Owner  trs    p6rformed  examinations  and taken  corrective measures   described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and ffective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be lia         n any manner for any personal injury or property damage or a loss of any kind arising from or connected with th       s ction.
Commissionsjf 9                   ,             qw National Board,1State, Province, and Endorsements 9/0
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner       AMERICAN ELECTRIC POWER                                               Date       04/14106 Name P.O. Box 60 Fort Wayne. IN 46801                                         Sheet     1         of   2 Address
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                       Unit    2  Component        2-SV-45A Name One Cook Place, Bddcman. MI 49106                                       JOB ORDER No. R0266622-05 Address                                                 Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                         Type Code Symbol Stamp N/A Name                                      Authorization No.         N/A One Cook Place, Bridgman, MI 49106                                      Expiration Date         N/A Address
: 4. Identification of System:   REACTOR COOLANT SYSTEM                       ISI CLASS 1
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed. N/A                 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6.     Identification of Components Repaired or Replaced and Replacement Components Name of             Name of.         Manufacturer     National         Other             Year         Repaired,   ASME Component           Manufacturer       Serial No.       Board     Identification       Built       Replaced,     Code (Material M&E,       No.                                       or Replacement Stamped ASP, PO)                                                                     (Yes or No) 2-SV-45A SAFETY VALVE             CROSBY         M&E 30-036392         NA           S/N             N/A       REPLACED         NO ASP 30673                     RV-1-8010A
: 7.     Description of Work REPLACED VALVE
: 8.     Test Conducted: Hydrostatic       D   Pneumatic           Nominal Operating Pressure
        . t..hOher- .      VT-2 at NOP/NOT, VT-3                         Pressure               psi. Test Temp.             F i7-/
 
Page 2 of 2 FORM NIS-2         (Back)
Job Order/File           R0266622-05
: 9. Remarks:           NOP/NOT VT-2 performed.             VT-3 on internals Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT             conforms to the rules of the ASME Code, Section XI.                                                           repair or replacement Type Code Symbol Stamp           NONE Certificate of Authorization No. NIA       Expiration Date         N/A Signed                     mons       Maintenance Weldina Suoervisor r    I Date                         ,20 6" Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of             Michigan           and employed by ABS GROUP INC.                                               of HOUSTON, TEXAS                                                               have inspected the components described in this Owner's Report during the period             Z/,*                    to     ,Z/,ll/                       , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
7227...............
7227...............
spector's Sigr dure Date 2,_ 20 66sions m, 16/9- //~, National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Date ' 04/09106 Name P.O. Box 60 Fort Wayne, IN 46801 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Address Sheet I of 2 Unit 2 Component 2-CS-536 JOB ORDER No. 05340018-01
Commis*sions      m, 16/9*- //~,
: 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place, Bridgman, MI 49106.Address 4. Identification of System: , CHEMICAL AND VOLUME CONTROL S'Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A YSTEM ISI CLASS 2 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification o f Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component .Manufacturer Serial No.' Board Ideteification Built Replaced, Code (Material M&E. No. or Replacement Stamped ASP, PO) (Yes or No)2-CS-536 VALVE CENTER N/A M&E 30-033374 NA ASME SA479 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY 7. Description of Work REPLACED C:ENTER SECTION ASSEMBLY 8. Test Conducted:
spector's Sigr dure                                                      National Board, State, Province, and Endorsements Date                  20 66 2,_
Hydrostatic 0 Pneumatic 1- Nominal Operating Pressure Other M Pressure psi. Test Temp. _ F q3 I Nr Page 2 of 2 FORM NIS-2 (Back)Job OrderlFile 05340018-01
 
: 9. Remarks: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed ae wie mmons M~ntnnc elin uorisr Date ,20696... .. ... .. ..... ...ce --lin -o r" ..... .Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS / have inspected the components described in this Owner's Report during the period __ ____-_-_ ____ _to le-7 d('. , and state that to the best of my knowledge and belief, the Owner has performed examinations and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in a manner for any personal injury or. property damage or a loss of any kind arising from or connected with this inspec Commissions
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
{,'d y2 ///)National Board, State, Pr6vinime, and Endbrsements
: 1. Owner       AMERICAN ELECTRIC POWER                                             Date       ' 04/09106 Name P.O. Box 60 Fort Wayne, IN 46801                                       Sheet    I            of 2 Address
/q/q FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC I Name P.O. Box 60 Fort Wayne, IN 46801 POWER Date 04/09/06 Sheet I of 2 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place, Bridgman, MI 49106 Unit 2 Component 2-CS-534 JOB ORDER No. 05340007-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Address 4. Identification of System: CHEMICAL AND VOLUME CONTROL SYSTEM ISI CLASS 2 5. (a) Applicable Const Code ANSI B31.1 1983 Ed, NIA Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-CS-534 VALVE CENTER N/A M&E 30-013933 NA ASME SA579 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY 7. Description of Work, REPLACED CENTER SECTION ASSEMBLY 8. Test Conducted:
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                     Unit 2      Component        2-CS-536 Name One Cook Place, Bridgman, MI 49106                                       JOB ORDER No. 05340018-01 Address                                                Repair Org. P.O. No., Job No., etc
Hydrostatic l Pneumatic
: 3. Work Performed by AEP/D.C. COOK Maint. Department                         Type Code Symbol Stamp N/A Name                                   Authorization No.        N/A One Cook Place, Bridgman, MI 49106                                     Expiration Date          N/A
-- Nominal Operating Pressure 1 Other F1 Pressure .psi. Test Temp. _ F?fl Page 2 of 2 FORM NIS-2 (Back)Job Order/File 05340007-01
                                . Address
: 9. Remarks: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A 4 Signed intenance Weldina Suoervisor Date 4e,? 7-. ,2092.1 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON. TEXAS / havye inspected the components described in this Owner's Report during the period /j/..///4.
: 4. Identification of System: , CHEMICAL AND VOLUME CONTROL S' YSTEM                              ISI CLASS 2
to -and state that to the best of my knowledge and belief, the Owner ha's peff6rmed examinationVsard taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectiop.,missions AJA O!nr-&sect;/ 9. 2 L 7 c..2'/4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne. IN 46B01 Address Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49105 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name Onp Ccnnk Plhqn Bridnman.
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A                   Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
MI 4910B Date 04109 Sheet I of 2)/O6 Unit 2 Component 2-CS-535 JOB ORDER No. 05340017-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Address 4. Identification of System: CHEMICAL AND VOLUME CONTROL SYSTEM ISI CLASS 2 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda S. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-CS-535 VALVE CENTER N/A M&E 30-013933 NA ASME SA479 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY 7. Description of Work REPLACED CENTER SECTION ASSEMBLY 8. Test Conducted:
: 6. Identification o f Components Repaired or Replaced and Replacement Components Name of             Name of           Manufacturer     National       Other           Year         Repaired,       ASME Component           .Manufacturer       Serial No.'     Board     Ideteification     Built         Replaced,         Code (Material M&E.     No.                                     or Replacement     Stamped ASP, PO)                                                                       (Yes or No) 2-CS-536 VALVE CENTER                 N/A         M&E 30-033374       NA       ASME SA479           N/A         REPLACED           NO SECTION                               ASP 31038                       TP 316 ASSEMBLY
Hydrostatic M Pneumatic D Nominal Operating Pressure Other [-"] Pressure psi. Test Temp. _ F lWlT5 Page 2 of 2 FORM NIS-2 (Back)Job Order/File 05340017-01
: 7.     Description of Work       REPLACED C:ENTER SECTION ASSEMBLY
: 9. Remarks: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are crrect and this REPAIR & REPLACEMENT the ASME Code, Section X1. repair or replacement conforms to the rules of Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed M~int~n~nce W~Idino Suoeivisor Date 20 "ze2 Owner o Owner'stenance Desiig neerT.t Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS havedinspected the components described in this Owner's Report during the period -./__ -____to .-, and state that to the best of my knowledge and belief, the Owner has performed examinations ar'd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecfibo
: 8.     Test Conducted: Hydrostatic 0         Pneumatic 1-       Nominal Operating Pressure Other   M                                     Pressure           psi. Test Temp.       _       F INr q3
--- -. -~~--Comr issionls A 6 i ~/3&#xa3;V?Inspector's Signature " P Date C"/hs 205 f&National Boar, State, Pr-vitnd, -a-a-E-o--o-en-t z
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne, IN 46801 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Address 3. Work Performed by AEPID.C. COOK Maint. Department Name One Cook Place. Bridaman.
Page 2 of 2 FORM NIS-2               (Back)
MI 49106 Date 11/21 Sheet 1 of 2 1/04 Unit 2 Component 2-OME-4 JOB ORDER No. 04322047-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A.... ...... ..... i I 1 4.5.6.Address Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1 (a) Applicable Const. Code ASME SEC. III 1986 Add. Code Case (b) Applicable Edition bf Section XI Utilized for Repairs or Replacements 1989, No Addenda Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-OME-4 PRESSURIZER MANWAY BOLT N/A M&E 30-009772 NA ASME SA193 N/A REPLACED NO ASP 16387 GR B7 7. Description of Work REPLACED 2 BOLTS AT MANWAY 8. Test Conducted:
Job OrderlFile 05340018-01
Hydrostatic
: 9. Remarks:
[, Pneumatic R- Nominal Operating Pressure LI1 Other "- VT-2, VT-1. PT Pressure A'OP psi. Test Temp. v.OQ F-jjj Wrr- Jv-b&#xfd;2 Page 2 of 2 FORM NIS-2 (Back)Job Order/File 04322047-01
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT                           conforms to the rules of the ASME Code, Section Xl.                                                                           repair or replacement Type Code Symbol Stamp           NONE Certificate of Authorization No.     N/A           Expiration Date               N/A Signed ae             wiemmons          ... .. ...   .. . .
: 9. Remarks: VT-I, VT-2 and PT performed.
ce    . .. lin ... -- -o r"
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed D 0yne hmmons Maintenance Weldina Suoervisor
                                                                                        ..... .
.... 1 -- [ .. ....Date 21, 40&#xfd; 2 0 6;I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Ves~el Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS , , haye inspected the components described in this Owners Report during the period 4 7E Y to and state that to the best of my knowledge and belief, the Owner has 15erforfned examinations
Date elin uorisr M~ntnnc                      ,20696 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of             MichiQan               and employed by ABS GROUP INC.                                                       of HOUSTON, TEXAS                                       /                                     have inspected the components described in this Owner's Report during the period __ ____-_-_____ _to                                                 le-*7 d('.               , and state that to the best of my knowledge and belief, the Owner has performed examinations and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
'and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in an manner for any personal injury or property damage or a loss of any kind arising from or connected with this insm .oi./" ,5-0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne, IN 46801 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, M1 49106 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place, Bridgman, MI 49106 Address Date 04/20/06 Sheet 1 of 2 Unit 2 Component 2-GRC-S573 JOB ORDER No. R0036212-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, NIA Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No)2-GRC-S573 SNUBBER GRINNELL M&E 30-024683 N/A SIN 33294 N/A Replacement NO ASP 30495 SEAL KIT GRINNELL M&E 30-025060 N/A N/A N/A Replacement NO ASP 26432"A" SEAL KIT GRINNELL M&E 30-040591 NIA N/A N/A Replacement NO ASP 28476 ROD BUSHING GRINNELL M&E 30-024791 NIA GRINNELL N/A Replacement NO ASP 30165 7. Description of Work REPLACED SNUBBER WITH REBUILT 8. Test Conducted:
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in a manner for any personal injury or. property damage or a loss of any kind arising from or connected with this inspec Commissions                   {,'d     y2         ///
Hydrostatic El Pneumatic D Nominal Operating Pressure Other F11 VT-3 Pressure NIA psi. Test Temp. NIA F 51 Page 2 of 2 FORM NIS-2 (Back)Job Order/File R0036212-O1 0 MOrnn-..a.U..n~Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rules of the ASME Code, Section Xl.REPLAC EMENT conforms to the repair or replacement Type.Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA D e V; rie&#xfd;o ns~Signed itenance Weldinri Supervisor Date 2,0 .20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS ./ .., hayv inspected the components described in this Owner's Report during the period to ,A_0/!//i'6o4 , and state that to the best of my knowledge and belief, the Owner has pOrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i econ.Commissions  
                                          )                                           National Board, State, Pr6vinime, and Endbrsements
''7 0 c 17.National Board, State, Province, and Endorsements Date FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne, IN 46801 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Date 04/19106 Sheet 1 of 2 Unit 2 Component 2-GRC-S538 JOB ORDER No. R0098999-01 3.4.5.6.Address Repair Org. P.O. No., Job No., etc Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place,. Bridgman, MI 49106 Expiration Date N/A Address Identification of System: REACTOR COOLANT SYSTEM IS[ CLASS 1 (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No)2-GRC-S538 SNUBBER GRINNELL M&E 30-024681 N/A S/N 33020 N/A Replacement NO ASP 29340 SEAL KIT GRINNELL M&E 30-025055 N/A N/A NIA Replacement NO ASP 17001"A" SEAL KIT GRINNELL M&E 30-040590 N/A N/A N/A Replacement NO ASP 21030 7.8.Description of Work REPLACED SNUBBER WITH REBUILT Test Conducted:
                        /                                         q/q
Hydrostatic El Pneumatic D Nominal Operating Pressure D Other I VT-3 Pressure N/A psi. Test Temp, N/A F 5-3 INIT-Page 2 of 2 FOR~M NIS-2 (33ack)Job Order/File RD09899MlO
 
: 9. Remarks:, Vr-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A 66,~rrn' 4 2 Signed Maintenance Weldina Suoervisor Date 200, ,20 f , -- .... ................  
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
... .. .. f n Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS /. h&#xfd;e inspected the components described in this Owner's Report during the period W O'//,5- to: e//l/V1, , and state that to the best of my knowledge and belief, the Owner has performed examinations~and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable,
: 1. Owner       AMERICAN ELECTRIC IPOWER                                            Date        04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801                                       Sheet   I           of 2 Address
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                     Unit 2      Component        2-CS-534 Name One Cook Place, Bridgman, MI 49106                                     JOB ORDER No. 05340007-01 Address                                               Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                       Type Code Symbol Stamp N/A Name                                   Authorization No.        N/A One Cook Place, Bridgman, MI 49106                                     Expiration Date        N/A Address
: 4. Identification of System:      CHEMICAL AND VOLUME CONTROL SYSTEM                          ISI CLASS 2
: 5. (a) Applicable Const Code ANSI B31.1 1983 Ed, NIA                  Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of          Manufacturer    National        Other          Year        Repaired,    ASME Component          Manufacturer        Serial No.     Board      Identification     Built        Replaced,    Code (Material M&E,    No.                                     or Replacement Stamped ASP, PO)                                                                 (Yes or No) 2-CS-534 VALVE CENTER                N/A          M&E 30-013933      NA      ASME SA579            N/A        REPLACED        NO SECTION                                ASP 31038                      TP 316 ASSEMBLY
: 7.      Description of Work,    REPLACED CENTER SECTION ASSEMBLY
: 8. Test Conducted: Hydrostatic        l    Pneumatic --        Nominal Operating Pressure        1 Other   F1                                  Pressure  .        psi. Test Temp.       _      F
                                                                                                                                ?fl
 
Page 2 of 2 FORM NIS-2    (Back)
Job Order/File        05340007-01
: 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT            conforms to the rules of the ASME Code, Section XI.                                                           repair or replacement Type Code Symbol Stamp            NONE Certificate of Authorization No. N/A          Expiration Date    N/A 4
Signed                                      intenance Weldina Suoervisor            Date 4e,?      7-.          ,2092
                                                                                                .1 Owner or Owner's Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of             Michigan            and employed by ABS GROUP INC.                                            of HOUSTON. TEXAS                                          /                  havye inspected the components described in this Owner's Report during the period                /j/..///4.            to      -                             and state that to the best of my knowledge and belief, the Owner ha's peff6rmed examinationVsard taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectiop.
                                                                ,missions    AJA O!nr -&sect;/9. 2 L
                                                                                          .. 2 7c
                                                              '/4
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner        AMERICAN ELECTRIC POWER                                              Date        04109)/O6 Name P.O. Box 60 Fort Wayne. IN 46B01                                        Sheet    I          of  2 Address Plant D.C. COOK NUCLEAR POWER PLANT                                      Unit 2      Component        2-CS-535 Name One Cook Place, Bridgman, MI 49105                                      JOB ORDER No. 05340017-01 Address                                                Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                         Type Code Symbol Stamp N/A Name                                     Authorization No.        N/A Onp Ccnnk Plhqn Bridnman. MI 4910B                                     Expiration Date         N/A Address
: 4. Identification of System:      CHEMICAL AND VOLUME CONTROL SYSTEM                            ISI CLASS 2
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A                Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda S. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of          Manufacturer    National        Other            Year          Repaired,      ASME Component          Manufacturer        Serial No.     Board      Identification      Built        Replaced,      Code (Material M&E,      No.                                      or Replacement  Stamped ASP, PO)                                                                        (Yes or No) 2-CS-535 VALVE CENTER                N/A         M&E 30-013933        NA        ASME SA479          N/A         REPLACED          NO SECTION                                ASP 31038                      TP 316 ASSEMBLY
: 7. Description of Work      REPLACED CENTER SECTION ASSEMBLY
: 8. Test Conducted: Hydrostatic      M    Pneumatic D        Nominal Operating Pressure Other [-"]                                    Pressure            psi. Test Temp.         _        F lWlT5
 
Page 2 of 2 FORM NIS-2      (Back)
Job Order/File 05340017-01
: 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are crrect and this REPAIR & REPLACEMENT            conforms to the rules of the ASME Code, Section X1.                                                           repair or replacement Type Code Symbol Stamp            NONE Certificate of Authorization No.      N/A        Expiration Date    N/A Signed                                  M~int~n~nce W~Idino Suoeivisor            Date            "ze2          20 Owner or Owner    o Owner's Owner'stenance Desiig neerT.t Designee,  Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Michigan            and employed by ABS GROUP INC.                                            of HOUSTON, TEXAS                                                              havedinspected the components described in this Owner's Report during the period                    /__ -____to -.              .-                        , and state that to the best of my knowledge and belief, the Owner has performed examinations ar'd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecfibo
                -  --  -. -
f&
                                                  ~~--Comr      issionls  A    6 i            ~/3&#xa3;V?
Inspector's Signature " P                                                National Boar, State, Pr-vitnd, -a-a-E-o--o-en-t        z Date      C"/hs 205
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner            AMERICAN ELECTRIC POWER                                                    Date        11/21 1/04 Name P.O. Box 60 Fort Wayne, IN 46801                                                Sheet      1          of  2 Address
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                              Unit    2  Component        2-OME-4 Name One Cook Place, Bridgman, MI 49106                                              JOB ORDER No. 04322047-01 Address                                                Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEPID.C. COOK Maint. Department                                Type Code Symbol Stamp N/A Name                                    Authorization No.         N/A One Cook Place. Bridaman. MI 49106
        ....  ......     ..... i      I    1 Expiration Date         N/A Address
: 4. Identification of System:              REACTOR COOLANT SYSTEM                      ISI CLASS 1
: 5. (a) Applicable Const. Code ASME SEC. III 1986                            Add. Code Case (b) Applicable Edition bf Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of                      Name of          Manufacturer    National        Other            Year        Repaired,     ASME Component                  Manufacturer        Serial No.      Board      Identification        Built        Replaced,      Code (Material M&E,      No.                                      or Replacement  Stamped ASP, PO)                                                                      (Yes or No) 2-OME-4 PRESSURIZER MANWAY BOLT                          N/A         M&E 30-009772        NA      ASME SA193              N/A       REPLACED          NO ASP 16387                        GR B7
: 7. Description of Work REPLACED 2 BOLTS AT MANWAY
: 8. Test Conducted: Hydrostatic [,                Pneumatic    R-    Nominal Operating Pressure      LI1 Other          "-        VT-2, VT-1. PT                        Pressure A'OP          psi. Test Temp.     &#x17d;v.OQ      F
                                                                                                                                    -jjj Wrr- Jv-b&#xfd;2
 
Page 2 of 2 FORM NIS-2            (Back)
Job Order/File            04322047-01
: 9. Remarks:          VT-I,    VT-2 and PT performed.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT                    conforms to the rules of the ASME Code, Section Xl.                                                                    repair or replacement Type Code Symbol Stamp            NONE Certificate of Authorization No. N/A       Expiration Date            N/A Signed      D 0yne  hmmons Owner or Owner's Designee, Title Maintenance Weldina Suoervisor
                                                  ....           1 i*  -- [ ..  ....
Date          40&#xfd;           21, 2 0 6; I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Ves~el Inspectors and the State or Province of            Michiqan            and employed by ABS GROUP INC.                                                   of HOUSTON, TEXAS                                      ,    ,                          haye inspected the components described in this Owners Report during the period                  4 7E Y              to                                          and state that to the best of my knowledge and belief, the Owner has 15erforfned examinations 'and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in an manner for any personal injury or property damage or a loss of any kind arising from or connected with this insm .oi.
                                          /"
                                                            ,5-0
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner      AMERICAN ELECTRIC POWER                          Date      04/20/06 Name P.O. Box 60 Fort Wayne, IN 46801                                    Sheet    1        of 2 Address
: 2.      Plant D.C. COOK NUCLEAR POWER PLANT                                  Unit  2    Component    2-GRC-S573 Name One Cook Place, Bridgman, M1 49106                                    JOB ORDER No. R0036212-01 Address                                              Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                      Type Code Symbol Stamp N/A Name                                      Authorization No.     N/A One Cook Place, Bridgman, MI 49106                                   Expiration Date      N/A Address
: 4. Identification of System:  REACTOR COOLANT SYSTEM              ISI CLASS 1
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, NIA Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of        Manufacturer      National      Other          Year        Repaired,       ASME Component          Manufacturer      Serial No.         Board Identification        Built      Replaced,       Code (Material M&E,        No.                                or Replacement    Stamp ASP, PO)                                                                    ed (Yes or No) 2-GRC-S573 SNUBBER              GRINNELL      M&E 30-024683          N/A     SIN 33294        N/A       Replacement        NO ASP 30495 SEAL KIT            GRINNELL      M&E 30-025060          N/A          N/A          N/A       Replacement        NO ASP 26432 "A" SEAL KIT          GRINNELL      M&E 30-040591          NIA         N/A          N/A       Replacement        NO ASP 28476 ROD BUSHING            GRINNELL      M&E 30-024791        NIA      GRINNELL          N/A      Replacement        NO ASP 30165
: 7.     Description of Work REPLACED SNUBBER WITH REBUILT
: 8.      Test Conducted: Hydrostatic    El Pneumatic D        Nominal Operating Pressure Other   F11    VT-3            Pressure      NIA  psi. Test Temp.     NIA    F 51
 
Page 2 of 2 FORM NIS-2    (Back)
Job Order/File R0036212-O1 0    MOrnn-.. a.U..n~
                              /rr_*
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this          REPLAC EMENT            conforms to the rules of the ASME Code, Section Xl.                                                            repair or replacement Type.Code Symbol Stamp          N/A Certificate of Authorization No. N/A       Expiration Date    NIA Signed      D e V;rie&#xfd;o        ns~            itenance Weldinri Supervisor        Date                    .20 2,0 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of            Michigan            and employed by ABS GROUP INC.                                       of HOUSTON, TEXAS                                  ./ , ..                hayv inspected the components described in this Owner's Report during the period                                  to    ,A_0/!//i'6o4              , and state that to the best of my knowledge and belief, the Owner has pOrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i econ.
Commissions         ''7         0   c   17.
National Board, State, Province, and Endorsements Date
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner       AMERICAN ELECTRIC POWER                         Date      04/19106 Name P.O. Box 60 Fort Wayne, IN 46801                                     Sheet    1        of  2 Address
: 2.     Plant D.C. COOK NUCLEAR POWER PLANT                                   Unit  2    Component    2-GRC-S538 Name One Cook Place, Bridgman, MI 49106                                   JOB ORDER No. R0098999-01 Address                                               Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                     Type Code Symbol Stamp NIA Name                                     Authorization No.     N/A One Cook Place,. Bridgman, MI 49106                                 Expiration Date       N/A Address
: 4. Identification of System:   REACTOR COOLANT SYSTEM             IS[ CLASS 1
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of             Name of       Manufacturer     National       Other         Year       Repaired,       ASME Component           Manufacturer     Serial No.         Board Identification       Built       Replaced,       Code (Material M&E,       No.                                 or Replacement     Stamp ASP, PO)                                                                     ed (Yes or No) 2-GRC-S538 SNUBBER             GRINNELL     M&E 30-024681         N/A     S/N 33020         N/A       Replacement         NO ASP 29340 SEAL KIT           GRINNELL       M&E 30-025055         N/A         N/A           NIA       Replacement         NO ASP 17001 "A" SEAL KIT         GRINNELL       M&E 30-040590         N/A         N/A           N/A       Replacement         NO ASP 21030
: 7.     Description of Work REPLACED SNUBBER WITH REBUILT
: 8.      Test Conducted: Hydrostatic     El Pneumatic D       Nominal Operating Pressure   D Other       I   VT-3           Pressure     N/A   psi. Test Temp,     N/A     F 5-3                                           INIT-
 
Page 2 of 2 FOR~M NIS-2     (33ack)
Job Order/File RD09899MlO
: 9. Remarks:,                           Vr-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this                   REPLACEMENT             conforms to the rules of the ASME Code, Section Xl.                                                                     repair or replacement Type Code Symbol Stamp                   N/A Certificate of Authorization No.             NIA       Expiration Date       N/A Signed  ,
66,~rrn'
              -- .... r.* ................
4    2 Maintenance Weldina Suoervisor f
                                                      ... .. ..           f   n Date                      ,20 200, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                     Michigan             and employed by ABS GROUP INC.                                       of HOUSTON, TEXAS                                         /.                           h&#xfd;e inspected the components described in this Owner's Report during the period                         W O'//,5-           to:     e//l/V1,               , and state that to the best of my knowledge and belief, the Owner has performed examinations~and taken corrective                       measures   described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable,
* any manner for any personal injury or property damage or a loss of any kind arising from or connected with this kts6)ction.
* any manner for any personal injury or property damage or a loss of any kind arising from or connected with this kts6)ction.
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Date ' 04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801 Rh__f 1 of 2 Address 2. Plant
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
: 1. Owner        AMERICAN ELECTRIC POWER                                                Date      ' 04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801                                          Rh__f    1          of  2 Address
: 2.      Plant D.C. COOK NUCLEAR POWER PLANT                                        Unit    2  Component        2-SI-210 Name One Cook Place, Bridgman, MI 49106                                        JOB ORDER No. 05340020-01 Address                                                  Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                          Type Code Symbol Stamp NIA Name                                      Authorization No.        N/A One Cook Place, Bridgman, MI 49106                                      Expiration Date          NIA Address
: 4. Identification of System:    SPENT FUEL POOL SYSTEM                      ISI CLASS 2
: 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add.                      Code Case (b) Applicable Edition of Section XA Utilized for
76*
76*
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC POWER Name P.O. Box 60 Fort Wayne. IN 46801 Date 04120106 Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Sheet 1 of 2 Unit 2 Component 2-GBD-S568 JOB ORDER No. R0037674-01 Address Repair Org. P.O. No., Job No., etc 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. NIA One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address 4. Identification of System: STEAM GENERATOR BLOWDOWN SYSTEM ISI CLASS 2 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989, No Addenda 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No)2-GBD-S568 SNUBBER GRINNELL M&E 30-024682 N/A S/N 33301 N/A Replacement NO ASP 26349 SEAL KIT GRINNELL M&E 30-025055 N/A N/A N/A Replacement NO ASP 23443"A" SEAL KIT GRINNELL M&E 30-040590 N/A N/A N/A Replacement NO ASP 21030 TAPER PiN GRINNELL M&E 30-024975 N/A GRINNELL N/A Replacement NO ASP 13571 FIG 312 7. Description of Work REPLACED SNUBBER WITH REBUILT 8. Test Conducted:
 
Hydrostatic  
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
'-- Pneumatic  
: 1. Owner       AMERICAN ELECTRIC POWER                           Date      04120106 Name P.O. Box 60 Fort Wayne. IN 46801                                   Sheet    1        of  2 Address
-] Nominal Operating Pressure-Other Fx&#xfd; VT-3 Pressure NIA psi. Test Temp. N/A F 77 Page 2 of 2 FORM NIS-2 (Back)Job Order/File R0037674-01
: 2. Plant D.C. COOK NUCLEAR POWER PLANT                                 Unit  2    Component    2-GBD-S568 Name One Cook Place, Bridgman, MI 49106                                 JOB ORDER No. R0037674-01 Address                                             Repair Org. P.O. No., Job No., etc
: 9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed D nMaintenance Welding Supervisor Date 5 20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS -- have ispected the components described in this Owner's Report during the period ____ /___-__to , and state that to the best of my knowledge and belief, the Owner haE performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins nd Commissions A/6A? 97r Y / ~ 7 Inspctors Si~atuNational Board, 8;tate, Province, and Endorsements
: 3. Work Performed by AEP/D.C. COOK Maint. Department                     Type Code Symbol Stamp N/A Name                                     Authorization No.       NIA One Cook Place, Bridgman, MI 49106                                 Expiration Date       N/A Address
.Date V42QC 6-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1. Owner AMERICAN ELECTRIC Name P.O. Box 60 Fort Wayne, IN 46801 POWER Address 2. Plant D.C. COOK NUCLEAR POWER PLANT Name One Cook Place, Bridgman, MI 49106 Address 3. Work Performed by AEP/D.C. COOK Maint. Department Name One Cook Place, Bridoman, MI 49106 Date 04103/06 Sheet I of 2 Unit 2 Component 2-NRV-153 JOB ORDER No. 05121006-01 Repair Org. P.O. No., Job No., etc Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4.5.6.Address Identification of System: REACTOR COOLANT SYSTEM ISI CLASS I (a) Applicable Const. Code ANSI-B31.1
: 4. Identification of System:   STEAM GENERATOR BLOWDOWN SYSTEM                   ISI CLASS 2
-1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)2-NRV-153 VALVE STEM NIA M&E 30-042247 NA HAYNES N/A REPLACED NO ASP 28948 ALLOY 25 PLUG N/A M&E 30-042070 NA ASTM N/A REPLACED NO ASP 26743 A479/276 T316 7. Description of Work REPLACED STEM AND PLUG 8. Test Conducted:
: 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989, No Addenda
Hydrostatic E' Pneumatic F Nominal Operating Pressure[Other D1 VT-2 at NOP/NOT Pressure psi. Test Temp. F INIT'~
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of             Name of         Manufacturer     National       Other         Year       Repaired,   ASME Component           Manufacturer       Serial No.       Board Identification       Built       Replaced,   Code (Material M&E,       No.                                 or Replacement Stamp ASP, PO)                                                               ed (Yes or No) 2-GBD-S568 SNUBBER             GRINNELL       M&E 30-024682         N/A     S/N 33301         N/A       Replacement     NO ASP 26349 SEAL KIT           GRINNELL       M&E 30-025055         N/A         N/A           N/A       Replacement   NO ASP 23443 "A" SEAL KIT         GRINNELL       M&E 30-040590         N/A         N/A           N/A       Replacement   NO ASP 21030 TAPER PiN           GRINNELL       M&E 30-024975       N/A     GRINNELL           N/A       Replacement   NO ASP 13571                     FIG 312
Page 2 of 2 FORM NIS-2 (Back)Job Order/File 05121006-01
: 7. Description of Work REPLACED SNUBBER WITH REBUILT
: 9. Remarks: VT-2 at NOP/NOT Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR& REPLACEMENT the ASME Code, Section X). repair or replacement conforms to the rules of Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA L-&avewy/M 411 _1 M a i Signed rntenance Weldina Supervisor Date , 20 Owner or-Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS / 4 haveyin pected the components described in this Owners Report during the period -____ _o _ -to ___________
: 8. Test Conducted: Hydrostatic     '-- Pneumatic   -]   Nominal Operating Pressure-Other   Fx&#xfd;   VT-3           Pressure     NIA   psi. Test Temp. N/A     F 77
_ , and state that to the best of my knowledge and belief, the Owner has lperf6rmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or impried, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabl in y manner for any personal injury or property damage or a loss of any kind arising from or connected with this ti n.I, -. Commissions A[& 0177 /g/ 8t~ZgS'z;Inspector's Sig2ature Date LC I 206G __National Board, State, Province, and Endorsements FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI 1. Owner Indiana Michigan Power Name P.O. Box 60, Fort Wayne, IN 46801 Date Julv 19. 2006 Sheet I of 2 Of 2 Address 2. Plant D.C. Cook Nuclear Power Plant Name Berrien Cognt. Bridmman, M1 49106 Addre=Unit 2 see Remarks RepairReplacement Organization P 0 No, Job No, etz Type Code Symbol Stapp NIA 3. Work Performed by AREVA NP Name 33"15 Old Forest Rd, Lynchbuugr VA 24501 Address Authorization No. N/A Expiration Date NIA 4. Identification of System Pressurizer, 2-OME-4. ASME III Class 1. ISI Class I 5. (a) Applicable Construction Code ASME ITL 1998 Edition 2000 Addenda, None Code Case (b) Applicable Edition of Secti6n X) Utilized for Repair/Replacemrnt Activity-.1989 Edition, no Addenda (see Remarks)(c) Applicable Section XI Code Case(s): N-638-1, N-416-1. N-504-2, N-460, 2142-2 (see Remarics)6. Identification of Components Repaired or Replaced and Replacement Components.
 
: 7. Description of Work: Welded Preemptive Weld Overlays on Dissimilar Metal Welds on Safety, Relief. Spray and Surge Nozzles 8. Tests Conducted:
Page 2 of 2 FORM NIS-2     (Back)
Hydrostatic
Job Order/File R0037674-01
[] Pneumatic
: 9. Remarks:             VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this     REPLACEMENT               conforms to the rules of the ASME Code, Section Xl.                                                         repair or replacement Type Code Symbol Stamp           N/A Certificate of Authorization No. N/A       Expiration Date   NIA Signed   D       nMaintenance                       Welding Supervisor       Date             5         20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of           Michigan         and employed by ABS GROUP INC.                                       of HOUSTON, TEXAS                                 --                       have ispected the components described in this Owner's Report during the period ____               /___-__to                                   , and state that to the best of my knowledge and belief, the Owner haE performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
[E Nominal Operating Pressure R Other [] Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawifgs may be used, provided (I) size is 8 1/2 x I 1 in. (A4)(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.nUrrT FORM NIS-2 (Back)0 anrr Tn 7=Appficable Manufarturer's Data Reports to be attached Line 2: AREVA Process Traveler Package Nos. 50-9007637-002, 50-9007639-002, 50-9007641-002 and AEP Job OrderNos.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins         nd Commissions     A/6A?   97rY        /         ~ 7 Inspctors Si~atuNational                                   Board, 8;tate, Province, and Endorsements
05237040 17, 18, 22, 23, 27.28, 32, 33, 37, 38 and 43.TAr~ ~(h~ rnr&#xb6; (~"V SeLettr 1Nos AEP.NR t:555-1 3 AEP1-JRC:6V)5S AIEP.NRC:6055 5aS nd AFEP.NRC:05-A d Alternatives to ASME XI 1989 Edition, no Addenda and applicable ASME Section XI Code Cases CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X)Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Sirned ConsultantDa Expiration Date N/A Date ) 0 1 1, ,20 06 Signed ..........
. Date     V42QC           6-
eor, AR Ne D eine T Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Micnigan and employed by ABS Consulting
 
=nc.of Houston, Texas have inspected the components described in this Owner's Report during the period November 9. 2004 to mti4ce &A IX 7"/'- o C, and state that to the best of my knowledge and belie&#xfd; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMIE Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any persona] injury or property damage or a loss of any kind arising from or connected with this inspection.
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
Commissions" /0M/,' AW/I rMate ipector'i Signature National Board, State, Province, and Endorsements 2 Q O,"}}
: 1. Owner       AMERICAN ELECTRIC POWER                                              Date        04103/06 Name P.O. Box 60 Fort Wayne, IN 46801                                       Sheet    I          of  2 Address
: 2.     Plant D.C. COOK NUCLEAR POWER PLANT                                     Unit    2  Component        2-NRV-153 Name One Cook Place, Bridgman, MI 49106                                     JOB ORDER No. 05121006-01 Address                                                Repair Org. P.O. No., Job No., etc
: 3. Work Performed by AEP/D.C. COOK Maint. Department                       Type Code Symbol Stamp N/A Name                                   Authorization No.        N/A One Cook Place, Bridoman, MI 49106                                   Expiration Date         N/A Address
: 4. Identification of System:      REACTOR COOLANT SYSTEM                      ISI CLASS I
: 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add.                   Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
: 6. Identification of Components Repaired or Replaced and Replacement Components Name of            Name of          Manufacturer    National        Other            Year        Repaired,      ASME Component          Manufacturer        Serial No.     Board      Identification      Built        Replaced,      Code (Material M&E,      No.                                     or Replacement  Stamped ASP, PO)                                                                      (Yes or No) 2-NRV-153 VALVE STEM                NIA          M&E 30-042247        NA          HAYNES              N/A      REPLACED          NO ASP 28948                    ALLOY 25 PLUG                N/A          M&E 30-042070        NA          ASTM              N/A      REPLACED          NO ASP 26743                      A479/276 T316
: 7.      Description of Work REPLACED STEM AND PLUG
: 8.     Test Conducted: Hydrostatic      E'  Pneumatic    F    Nominal Operating Pressure[
Other    D1      VT-2 at NOP/NOT                                    Pressure                psi. Test Temp.            F INIT'~
 
Page 2 of 2 FORM NIS-2      (Back)
Job Order/File 05121006-01
: 9. Remarks:          VT-2 at NOP/NOT Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR& REPLACEMENT              conforms to the rules of the ASME Code, Section X).                                                             repair or replacement Type Code Symbol Stamp              NONE Certificate of Authorization No.          NIA    Expiration Date    NIA Signed    L-&avewy/M            411_1 Mairntenance Weldina Supervisor              Date ,                        200*
Owner or-Owner's Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of                Michiqan        and employed by ABS GROUP INC.                                               of HOUSTON, TEXAS                                    /    4                      haveyin pected the components described in this Owners Report during the period                      -____        _o-to
_  ___________                _      , and state that to the best of my knowledge and belief, the Owner has lperf6rmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or impried, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabl in y manner for any personal injury or property damage or a loss of any kind arising from or connected with this            ti n.
I,   -.              Commissions        A[&0177 /g/ 8t~ZgS'z; Inspector's Sig2ature                                                    National Board, State, Province, and Endorsements Date      LC I 206G __
 
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
: 1. Owner Indiana Michigan Power                                      Date Julv 19. 2006 Name P.O. Box 60, Fort Wayne, IN 46801                                  Sheet I          of 22 Of Address
: 2. Plant D.C. Cook Nuclear Power Plant                              Unit 2 Name Berrien Cognt. Bridmman, M1 49106                              see Remarks Addre=                                RepairReplacement Organization P 0 No, Job No, etz
: 3. Work Performed by AREVA NP                                        Type Code Symbol Stapp NIA Name Authorization No. N/A 33"15 Old Forest Rd, Lynchbuugr VA 24501                          Expiration Date NIA Address
: 4. Identification of System Pressurizer, 2-OME-4. ASME III Class 1. ISI Class I
: 5.     (a) Applicable Construction Code ASME ITL 1998 Edition 2000                          Addenda, None                Code Case (b) Applicable Edition of Secti6n X) Utilized for Repair/Replacemrnt Activity-.1989 Edition, no Addenda (see Remarks)
(c) Applicable Section XI Code Case(s): N-638-1, N-416-1. N-504-2, N-460, 2142-2 (see Remarics)
: 6. Identification of Components Repaired or Replaced and Replacement Components.
: 7. Description of Work: Welded Preemptive Weld Overlays on Dissimilar Metal Welds on Safety, Relief. Spray and Surge Nozzles
: 8. Tests Conducted:          Hydrostatic []      Pneumatic [E        Nominal Operating Pressure R Other  []    Pressure                psi    Test Temp.                   OF NOTE: Supplemental sheets in form of lists, sketches, or drawifgs may be used, provided (I) size is 8 1/2x I1 in. (A4)
(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
nUrrT
 
FORM NIS-2 (Back) 0 7=
anrr      Tn Appficable Manufarturer's Data Reports to be attached Line 2: AREVA Process Traveler Package Nos. 50-9007637-002, 50-9007639-002, 50-9007641-002 and AEP Job OrderNos. 05237040 17, 18, 22, 23, 27.28, 32, 33, 37, 38 and 43.
TAr~ ~(h~ rnr&#xb6;  (~"V            SeLettr 1Nos AEP.NR t:555-1 3 AEP1-JRC:6V)5S AIEP.NRC:6055                          5aSnd AFEP.NRC:05-A d Alternatives to ASME XI 1989 Edition, no Addenda and applicable ASME Section XI Code Cases CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X)
Type Code Symbol Stamp N/A Certificate of Authorization No. NIA                                          Expiration Date N/A Sirned Kv.'"D*.E ConsultantDa Date ) 0 11,                                 ,20 06 Signed .......... Owner    eor, or AR  NeD Owner's    eine T Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Micnigan            and employed by ABS Consulting =nc.
of Houston, Texas                                have inspected the components described in this Owner's Report during the period November 9. 2004                                to mti4ce        &AIX          7"/'- o C,                                               and state that to the best of my knowledge and belie&#xfd; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMIE Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any persona] injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions"          /0M/,'       AW/I ipector'i Signature                                          National Board, State, Province, and Endorsements rMate                                                               2QO,"}}

Revision as of 15:58, 23 November 2019

Inservice Inspection Summary Report
ML062280474
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 08/04/2006
From: Jensen J
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:6055-10
Download: ML062280474 (85)


Text

Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place Bridgman, MI49106 111 ER* J* R AE~corn A unitof American Electric Power August 4, 2006 AEP:NRC:6055-10 10 CFR 50.55a Docket No. 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 2 INSERVICE INSPECTION

SUMMARY

REPORT The attachment to this letter provides a copy of the inservice inspection summary report for activities at Donald C. Cook Nuclear Plant Unit 2, National Board (State of Michigan)

Number 1 (Mich. M-324232-M), located in Bridgman, Michigan. The plant is owned by Indiana Michigan Power Company, P.O. Box 60, Fort Wayne, IN, 46801.

The Unit 2 commercial service date is July 1, 1978, and the Authorized Code Inspectors during the report period were Mr. A. S. Jimenez and Mr. J. A. Longenberger, both of whom were employed by ABS Group, Inc. of Houston, Texas.

The examinations, tests, replacements, repairs performed, conditions observed, and corrective measures taken are summarized in the attached report. Inservice inspection activities were performed in accordance with the rules and requirements of the American Society of Mechanical Engineers' Code,Section XI, 1989 Edition (no Addenda) and 1992 Edition with the 1992 Addenda, as applicable.

There are no new commitments in this letter. Should you have any questions, please contact Ms. Susan D. Simpson, Regulatory Affairs Manager, at (269) 466-2428.

Sin~cerqqly, JoseeSupport Jensen Services Vice President

Attachment:

Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2, 2006, Unit 2 Cycle 16 Refueling Outage.

RV/rdw AOL,7

U. S. Nuclear Regulatory Commission AEP:NRC:6055-10 Page 2 c: R. Aben, DLEG/BCCFS/BD J. L. Caldwell, NRC Region III K. D. Curry, Ft. Wayne AEP, w/o attachment J. T. King, MPSC, w/o attachment MDEQ - WHMD/RPMWS, w/o attachment NRC Resident Inspector P. S. Tam, NRC Washington, DC

Attachment to AEP:NRC:6055-10 Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2 2006, Unit 2 Cycle 16 Refueling Outage

INSERVICE INSPECTION

SUMMARY

REPORT FOR THE DONALD C. COOK NUCLEAR PLANT UNIT 2 2006, Unit 2 Cycle 16 REFUELING OUTAGE INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report for Inspection Period From November 10, 2004 to May 5, 2006 Prepared by: "4 ý eDat I ogram Owner LL12ijjl o

Reviewed by: Date:

Engineering Programs Supervisor 1 of 82 Total Pages

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report of Inservice Inspections From November 10, 2004 to May 5, 2006 TABLE OF CONTENTS Pages Section 1 Introduction 3 Section 2 NIS-1 Inservice Inspection 4-6 Summary Report Section 3 Abstract of Examinations, Results,. 7-16 And Corrective Actions for Class 1 And Class 2 Components Section 4 System Pressure Tests 17 Section 5 Snubber Tests 18-20 Section 6 ASME Section XI, Article IWE and IWL 21-26 Section 7 ASME Section XI, Steam Generator 27 Eddy Current Examinations Section 8 NIS-2 Repair and Replacement 28-29 Reports Index Section 9 NIS-2 Repair and Replacement 30-82 Reports 2

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 1 INTRODUCTION This report summarizes the Inservice Inspection (ISI) activities performed at the Donald C. Cook Nuclear Plant (CNP) Unit 2, for the period of November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Unit 2 Cycle 16, 2006, Refueling Outage. This is the second and final refueling outage of the Second Inspection Period of the Third Ten-Year Interval.

These activities were performed in accordancb with the requirements of the ASME Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. As of July 1, 1996, the third ten-year inspection interval began and the applicable code of record for ISI activities became ASME Section XI, 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda for the Containment as applicable.

The purpose of this report is to satisfy the requirements of IWA-6000 for the submittal of an Inservice Inspection Summary Report at the completion of each refueling outage.

Examination and tests conducted since the preceding summary report are included in this report. Repairs and replacements are also included in this report per the requirements of the 1989 Edition of ASME Section XI, IWA-6220.

Contents of this report have been reviewed and verified correct with supporting documentation available at the plant for review if required.

3

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 2 NIS-1 INSERVICE INSPECTION

SUMMARY

REPORT Acronyms CCW Component Cooling Water System CS Emergency Core Cooling System CTS Containment Spray System ESW Essential Service Water System' FW Feedwater System MDAFP Motor Driven Auxiliary Feedwater Pump MS Main Steam System NOP Normal Operating Pressure NOT Normal Operating Temperature RCP Reactor Coolant Pump RCS Reactor Coolant System RHR Residual Heat Removal Syktem RWST Refueling Water Storage Tank SI Safety Injection System TDAFP Turbine Driven Auxiliary Feedwater Pump 4

FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft. Wayne, IN 46801 (Name and Address of Owners)
2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Brid*gman, MI 49106 (Name and Address of Plant)
3. Plant Unit: Two
4. Owner Certification of Authorization (if required): N/A
5. Commercial Service Date: 07/01/78
6. National Board Number for Unit: 1 (Mich. M-324232-M?)
7. Components Inspected Component or Manufacturer or Manufacturer or State or Province National Board Appurtenance Installer Installer Serial Number Number Number Reactor Pressure Chicago Bridge T-1 M-324232-M I Vessel and Iron Steam Generator, Westinghouse/MK 1341- Upper, M-324-234-M 68 Upper 2-OME-3-1 -Ferguson Assembly 37 - Lower 3367G - Lower Assembly East RHR Heat Westinghouse/MK 1344 - Upper M-324-237-M 68 Upper Exchanger -Ferguson Assembly 38 - Lower 2-HE-17E 3368G - Lower Assembly Pressurizer Westinghouse 1231 M-324233-M 6894 2-OME-4 West CTS Heat Yuba 69-G-226-ID N/A N/A Exchanger 2-HE-18W West RHR Heat Engineers and S-15586-C N/A N/A Exchanger Fabricators, INC 2-HE-17W Containment Graver N/A N/A N/A Piping Systems - Power Systems N/A N/A N/A RCS, RHR, SI, Inc. and TUBECO CTS, CCW, CS, ESW, FW, MS Pipe Supports Grinnell 5
8. Examination Dates: November 10, 2004 to May 5. 2006
9. Inspection Period Identification: Second
10. Inspection Interval Identification: Third
11. Applicable Edition of Section XI 1989 no Addenda & 1992 with 1992 Addenda
12. Date/Revision of Inspection Plan: 8/03 Rev. I
13. Abstract of Examinations. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

See Sections 3, 4, 5, 6, and 7

14. Abstract of Results of Examinations and Tests.

See Sections 3, 4, 5, 6 and 7

15. Abstract of Corrective Measures.

See Sections 3, 4, 5, 6, and 7 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code; -Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section X).

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date .'D' _, 4 20 No Signed Indiana Michigan Power Co. By Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of,.e,- tt,,) K and employed by An_? CJ.P.. /IAIz of Agljh.&jny ,r.4" have inspected the components described in this Owner's Report during the period,,,.,,i, /v ,to LIE41e. .,0. , and state that to the best of my knowledge and belief, the Owner has performed examiniiations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions Vz- cj/

Inspector s Signature National Board, State, Province, and Endorsements D ate 20oe.

6

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 3 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR CLASS 1 AND CLASS 2 COMPONENTS Inservice examinations were performed during the period November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Third 10-Year Interval, Second Inspection Period, -Second Refueling Outage (Unit 2 Cycle 16). All examinations were in accordance with the 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda as applicable.

Examinations were scheduled and performed according to the Third Ten-Year Long Term Inservice Examination Plan for Class 1, 2, and 3 Systems and Components for CNP, Unit 2. This is the currently approved ISI examination plan that identifies specific activities to be performed on a refueling outage basis.

Twenty-six (26) ASME Class 1 and twenty-eight (28) ASME Class 2 components were examined. A combination of Ultrasonic, Magnetic Particle, Liquid Penetrant and Visual examination methods were used. Two supports failed the VT-3 examination. Support 2-ACS-R-913 had a loose nut on an embedment plate that was evaluated as an original construction defect and not inservice induced and documented via Work Request 06016013. Support 2-AFW-C-4034 also had a loose nut on a-pipe clamp. This condition was evaluated by Design Engineering (Condition Report 06102054) and Engineering Programs and found acceptable. The cause was attributed to original construction. The supports upstream, downstream and in the immediate vicinity of these two supports were examined and found acceptable. No sample expansions were required.

To proactively address issues with Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 82/182 weld locations in the Unit 2 pressurizer safe ends, all the safe ends on the Unit 2 pressurizer received Pre-emptive Weld Overlays (PWOL) to mitigate the potential for PWSCC. Each location received a fully qualified ASME Section XI Appendix VIII, Supplement 11 ultrasonic examination and a surface examination over 100% of the required weld volume. No evidence of PWSCC or other rejectable indications were observed.

During the Unit 2, Cycle 16 refueling outage, Indiana Michigan Power Company (I&M),

the licensee for CNP Unit 2, performed a bare-metal visual inspection of the CNP Unit 2 reactor pressure vessel (RPV) bottom-mounted instrumentation (BMI) nozzle penetrations, and bare-metal and volumetric examinations of the RPV upper head in response to NRC Revised Order EA-03-009, "Issuance of Order Establishing Interim 7

Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors".

The BMI inspection was conducted by contractor and I&M personnel, and included personnel qualified as American Society of Mechanical Engineers Code,Section XI, Level II examiners. The bottom two sections of insulation were lowered to allow unobstructed access to all penetrations and the membrane areas of the lower reactor vessel. A pole-mounted camera was used to perform a VT-2 examination to VT-3 examination criteria for distance and lighting on all 58 Unit2 RPV BMI nozzle penetrations, including 360 degrees around each BMI penetration. No boric acid deposits were found at any RPV BMI nozzle penetration or anywhere on the RPV bottom-head surface area. No boric acid residue sampling or analysis was required or performed. The as-found condition of the Unit 2 RPV bottom head was identical to the as-left condition following the bottom cleaning and re-inspection performed during the Unit 2, Cycle 15 refueling outage. No indications of through-wall leakage were found during the Unit 2, Cycle 16 RPV BMI inspection. The inspection results were digitally recorded, and copies of the video files were saved to computer drives as video clips.

A 100% bare-metal visual examination of the Unit 2 RPV upper head showed no evidence of pressure boundary leakage. However, evidence of above-head leakage from an external source was discovered near Penetration Number 42. To ensure that the source of residue was not the result of pressure-boundary leakage, the following were performed.

  • A chemical sample analysis, which determined the residue to be 1.3 to 1.6 years old, was performed.
  • Extensive visual examinations of Penetration 42 (prior to and after residue sampling and cleaning) were performed. The examination indicated that the origin of the residue was not from the annular gap between the vessel head and the penetration tube. Evidence of previous above-head leakage, including pooling and dripping, was observed on the insulation panel seam in the vicinity above Penetration 42.

0 A volumetric examination, including ultrasonic/eddy current of the inside diameter of the penetration tube, was performed. No rejectable indications were found and no evidence of leakage in the shrink-fit region was observed in the J-groove weld inspection data.

& Supplemental eddy current examinations of the J-groove weld and penetration tube outside diameter surfaces were conducted. No rejectable indications were observed in the J-groove weld inspection data.

  • A manual surface examination using liquid penetrant was performed on the Penetration 42 nozzle immediately above the reactor vessel closure head. No indications were observed.

A 100 % volumetric examination of the 78 control rod drive mechanism penetrations and the single vent penetration in the Unit 2 RPV head was completed in accordance with Section IV.C(5)(b)(iii) utilizing an approved relaxation of the requirements obtained in 8

accordance with Section JV.F. No unacceptable indications were found. No repairs of any head penetrations were needed or performed.

System pressure tests did not reveal any degradation of the system pressure boundary or the installed bolting.

The following Code Cases were utilized during this reporting period:

N-416-1 N-460 N-504-2 N-509 N-533 N-616 N-638-1 N-627 N-491 -1 Nondestructive examinations were performed by WesDyne, AREVA/Framatome and I&M personnel in accordance with procedures approved for use at CNP.

9

Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.

Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
6. National Board Number for Unit: 1 (Mich. M-
3. Plant Unit: TWO 324232-M)

Summary Component No. Component ID Description Item Procedure . Method/Reoort/Results Class I Category B-B 006500 2-PRZ-15 UPPER HEAD TO UPPER B2.11 54-IS1-130 UT UT-06-027 Accept SHELL 54-IS1-130 IUTUT-06-028 Accept 54-IS1-130 UT UT-06-031 Accept 54-ISI-130 UT UT-06-032 Accept 006900 2-PRZ-19 LONGITUDINAL SEAM B2.12 54-ISI-130 UT UT-06-029 Accept 54-IS1-130 UT UT-06-026 Accept 54-ISI-130 UT UT-06-025 Accept 54-ISI-130 UT UT-06-030 Accept 54-ISI-130 UT UT-06-024 Accept 54-ISI-130 IUTUT-06-023 Accept 008600 STM-21-01 LOWER HEAD TO TUBE B2.40 54-1S1-130 UT UT-06-013 Info SHEET 54-IS1-130 UT UT-06-016 Accept 54-ISI-130 UT UT-06-015 Accept 54-ISI-130 UT UT-06-014 Accept 54-ISI-130 UT UT-06-017 Accept Class 1 Category B-G-1 004700 2-RPV-FLANGE THREADS 1 THROUGH 54 86.40 54-1S1-108 UT UT-06-004 Accept 10

Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: indiana Michigan Power Co., PO Box 60, Ft.

Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
6. National Board Number for Unit: I (Mich. M-
3. Plant Unit: TWO 324232.M)

Summary Component No. Component ID Description Item Procedure Method/Report/Results Class I Category B-G-2 030400 2-RC-26-09-FB FLANGE BOLTING B7.50 12-QHP-5050- VT VT-06-021 Accept NDE-006 049000 2-RC-32-13-FB FLANGE BOLTING B7.50 12-QHP-5050-, VT VT-06-038 Accept NDE-006 053100 2-RC-33-18-FB FLANGE BOLTING B7.50 12-QHP-5050- VT V17-06-041 Accept NDE-006 071600 2-RC-515-21-FB FLANGE BOLTING B7.50 12-QHP-5050-, VT VT-06-039 Accept NDE-006 078600 2-RC-517-23-FB FLANGE BOLTING B7.50 12-QHP-5050- VT VT-06-037 Accept NDE-006 153075 PUMP BOLTS (12 - 2" BOLTS)

........... * .. . ..... I LOWER SEAL HOUS ING B7.50 12-QHP-5050- VT VT-06-036 Accept BOLTS NDE-006 220200 SV-45A BODY TO BONNET B7.70 12-QHP-5050- VT VT-06-018B Accept NDE-006 220700 SI-170-L2 BODY TO BONNET B7.70 12-QHP-5050- VT VT-06-029 Accept BOLTING NDE-006 221550 IMO-325 FLANGE BOLTING B7.70 12-QHP-5050- VT VT-06-033 Accept NDE-006 222400 IMO-128 FLANGE BOLTING B7.70 12-QHP-5050- VT VT-06-028 Accept NDE-006 Class I Category B-J 088100 2-SI-56-03 ELBOW TO PIPE B9.11 54-ISI-836 UT UT-06-011 Accept 11

Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.

Wayne, IN 46801

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, 4. Owner Certificate of Authorization (If Req.): NIA Bridgman, MI 49106
5. Commercial Service Date: 0710111978
3. Plant Unit: TWO 6. National Board Number for Unit: I (Mich. M-324232-M)

Summary Component No. Component ID Description Item Procedure Method/Report/Results =L ....

54-ISI-836 UT UT-06-012 Accept 089750 2-SI-56-1 9 TEE TO PiPE 89.11 54-1SI-836 UT UT-06-019 Accept 54-ISI-836 UT UT-06-018 Accept 54-1SI-836 UT UT-06-020 Accept 092700 2-SI-57-17 PIPE TO ELBOW B9.11 54*ISI-836 UT UT-06-022 Accept 54-ISI-836 UT UT-06-021 Accept 151900 2-WD-822-03 ELBOW TO PIPE 89.40 54-ISI-836 UT UT-06-038 Accept 54-ISI-836 UT UT-06-037 Accept Class 1 Category B-K-1 094800 2-SI-58-03-PL I AND 2 PIPE LUG 810.10 12-QHP-5050- PT PT-06-003 Accept NDE-001 Class I Category B-N-1 006010 RPV UPPER INTERNALS & AREAS ACCESSIBLE 813.10 54-ISI-364 VT VE-06-001 Accept SURFACES DURING NORMAL REFUELING Class 1 Category F-A 600700 2-GRC-R-524 PIPE SUPPORT F1.10 12-QHP-5050- VT VT-06-035 Accept COMPONENT WA NDE-006 12

Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.

Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
6. National Board Number for Unit: I (Mich. M-
3. Plant Unit: TWO 324232-M)

Summary Component No. Component ID Description Item Procedure Method/Report/Results 601200 2-ARC-R-522B PIPE SUPPORT F1.101 12-QHP-5050- VT VT-06-020 Accept COMPONENT NDE-006 604400 2-GRC-R-565 PIPE SUPPORT FI.10A 12-QHP-5050- VT VT-06-042 Accept COMPONENT NDE-006 607330 2-ASI-R-5301 PIPE SUPPORT F1.10A 12-QHP-5050- VT Vr-06-032 Accept COMPONENT NDE-006 607800 2-GSI-R-698 PIPE SUPPORT Fl.10A 12-QHP-5050- VT VT-06-031 Accept COMPONENT NDE-006 609220 2-GCS-R-543 PIPE SUPPORT F1.10 12-QHP-5050- VT VT-06-027 Accept COMPONENT WB NDE-006 Class 2 Category C-B 300070 STM-21-FWN NOZZLE TO SHELL C2.21 54-ISI-130 UT UT-06-033 Accept 54-ISI-130 UT UT-06-034 Accept 54-151-130 UT UT-06-035 Accept 300090 STM-21-FWN-IRS C2.22 54-ISI-132 UT UT-06-036 Accept 300700 E-RHRHEX-IN NOZZLE TO SHELL C2.21 54-ISI-136 UT UT-06-005 Info 54-ISI-240 PT PT-06-002 Accept 54-ISI-136 IUTUT-06-006 Accept 54-IS1-136 UT UT-06-007 Info 13

Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.

Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, Mi 49106 5. Commercial Service Date: 0710111978
6. National Board Number for Unit: I (Mich. M-
3. Plant Unit: TWO 324232-M)

Summary Component No. Comoonent ID Description Item Procedure Method/RenootResults 300871 2-ILA-110-Vl Ile Procedure Method/Rer)ort/Results INSTRUMENT NOZZLE TO C2.21 54-ISI-836 UT UT-06-009 Accept SHELL 300873 2-ILA-111-Vl INSTRUMENT NOZZLE TO C2.21 54-ISI-836 UT UT-06-010 Accept SHELL 300874 2-ILA-11 l-V2 INSTRUMENT NOZZLE TO C2.21 54-ISI-836 UT UT-06-008 Accept SHELL Class 2 Category C-C 310915 2-SI-9-05S-PS 1 THRU 4 4 PIPE LUG C3.20 12-QHP-5050- PT PT-06-001 Accept NDE-001 319170 2-FW-74-OIF PENETRATION SUPPORT C3.20 12-QHP-5050- PT PT-06-004 Accept WELD NDE-001 323060 MSIV-MRV-230-S1 C3.40 12-QHP-5050- MT MT-06-001 Accept NDE-002 323070 MSIV-MRV-230-S2 C3.40 12-QHP-5050- MT MT-06-002 Accept NDE-002 Class 2 Category C-G 322950 MSIV-MRV-210-1 CYLINDER WELD C6.20 12-QHP-5050- MT MT-06-003 Accept NDE-002 Class 2 Category F-A 700010 CS-1 BRACKET F1.40 12-QHP-5050- VT VT-06-014 Accept NDE-006 700020 CS-2 BRACKET F1.40 12-QHP-5050- VT V17-06-015 Accept NDE-006 14

Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft.

Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
6. National Board Number for Unit: I (Mich. M-
3. Plant Unit: TWO 324232-M)

Summary Component No. Component ID Description Item Procedure Method/Report/Results 700040 CS-4 BRACKET F1.40 12-QHP-5050- VT VT-06-017 Accept NDE-006 713097 2-ARH-R-5011 F-A F1l.20ACOMPONENT F1.20A 12-QHP-5050- VT Vr-06-03Q Accept NDE-006 713285 2-GRH-V-9 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-034 Accept COMPONENT WC NDE-006 713870 2-GCTS-L-43 PIPE SUPPORT Fl.20B 12-QHP-5050-. VT VT-06-022 Accept COMPONENT NDE-006 713940 2-GCTS-R-46 PIPE SUPPORT F1.20B 12-QHP-5050- VT V17-06-024 Accept COMPONENT NDE-006 714120 2-GCTS-V-54 PIPE SUPPORT F1.20C 12-QHP-5050- VT V17-06-040 Accept COMPONENT NDE-006 716065 2-GCTS-R-17 PIPE SUPPORT F1.20A 12-QHP-5050- VT VT-06-005 Accept COMPONENT NDE-006 716240 2-GCTS-R-8 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-006 Accept COMPONENT WB NDE-006 751600 2-GFW-V-881 - PIPE RESTRAINT F1.20C 12-QHP-5050- VT VT-06-01 9 Accept COMPONENT NDE-006 754600 2-AFW-C-4034 PIPE SUPPORT F1.20C 12-QHP-5050- VT VT-06-043 Reject COMPONENT NDE-006 Evaluation Disposition Acceptable per DES evaluation contained in CRE 06102054.

Acceptable:

15

Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16

1. Owner: Indiana Michigan Power Co., P0 Box 60, Ft.

Wayne, IN 46801 4. Owner Certificate of Authorization (if Req.): NIA

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
6. National Board Number for Unit: 1 (Mich. M-
3. Plant Unit: TWO 324232-M)

Summary Component No. Component ID Description Item Procedure Method/Report/Results 763240 2-GSI-L-30 PIPE SUPPORT F1.20A 12-QHP-5050- VT VT-06-023 Accept COMPONENT NDE-006 763710 2-GSI-R-822 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-026 Accept COMPONENT WA NDE-006 763740 2-GSI-L-826 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-025 Accept COMPONENT WA NDE-006 764210 2-ACS-R-1 15 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-009 Accept COMPONENT WB NDE-006 764380 2-GCS-L-123 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06.007 Accept COMPONENT WA NDE-006 764940 2-ACS-R-913 PIPE SUPPORT F17.20B 12-QHP-5050- VT VT-06-008 Reject COMPONENT NDE-006 16

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 4 ABSTRACT OF SYSTEM PRESSURE TESTS RESULTS Inservice Inspection System Pressure Tests were performed during the period November 10, 2004, to May 5, 2006. These tests were performed in accordance with the requirements of ASME Section XI, 1989 (no Addenda) and 1992 Editions with 1992 Addenda, Articles IWA-5000, IWB-5000, IWC-5000, IWD-5000, Code Case N-416-1, Code Case N-533 and N-616, as applicable.

Pressure tests for portions of systems identified below were performed during this outage.

The remainder of the pressure tests for the period will be performed in conjunction with functional tests, inservice operation, and special procedures as applicable. No pressure boundary through-wall leaks were identified.

Job Completion Order Activity Test Description Date R0227736 2 North SI pump and associated piping 5/6/2006 R0227736 4 South SI pump and associated piping 5/612006 R0227736 6 Accumulators and associated piping 4/17/2006 R0227736 8 Bit tank and associated piping 3/25/2006 R0227736 9 South seal water injection filter 3124/2006 R0227736 10 North seal water injection filter 4/17/2006 R0227736 11 East Charging Pump and associated piping 3/24/2006 R0227736 12 West Charging Pump and associated piping 4/19/2006 R0227736 13 East CTS Pump and Associated Piping 4/11/2006 R0227736 14 West CTS Pump and Associated Piping 5/5/2006 R0227736 15 Spray Additive tank and associated piping 3/24/2006 R0227736 16 Seal water leak off piping at RCPs 5/6/2006 R0227736 17 Seal water filter, heat exchanger, and associated piping 3/25/2006 R0227736 18 TDAFP Motor Operated Valves to Check Valves 4/30/2006 R0227736 19 Letdown heat exchanger and associated piping 5/5/2006 R0227736 23 TDAFP and associated piping 5/5/2006 R0227736 24 East MDAFP and associated piping 5/5/2006 R0227736 25 West MDAFP and associated piping 8/26/2005 R0266778 1 RCS NOP/NOT 8/24/2005 R0233818 2 ESW Pumps and associated piping 5/6/2006 R0243844 1 Condensate Storage Tank and Associated Piping 5/6/2006 R0243844 2 RWST and associated piping 4/17/2006 R0243844 3 South Spent Fuel Pool Pumps and Associated Piping 3/25/2006 R0243844 4 North Spent Fuel Pool Pumps and Associated Piping 3/24/2006 R0243844 5 South Boric Acid Storage Tank and Associated Piping 4/17/2006 R0243844 6 Volume Control Tank and Associated Piping 3124/2006 17

INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.

UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 SECTION 5 ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS Snubber examinations and functional testing were performed in conjunction with the maintenance procedures implemented to satisfy technical specification surveillance requirements. Provided is a summary of the as-found visual examinations and as-found functional test results.

Snubber VT-3 Visual Examinations Snubber No. Exam Date Job Order No. Results 2-GRC-$537 04-04-06 R0266439 Acceptable 2-GRC-S538 04-18-06 R0266439 Acceptable 2-GRC-$555 04-18-06 R0266439 Acceptable 2-GRC-$562 04-04-06 R0266439 Acceptable 2-GRC-$564 04-18-06 R0266439 Acceptable 2-GRC-$566 04-04-06 R0266439 Acceptable 2-GRC-$573 04-18-06 R0266439 Acceptable 2-GRC-S575 04-04-06 R0266439 Acceptable 2-GRC-S582 04-18-06 R0266439 Acceptable 2-GRC-S592 04-04-06 R0266439 Acceptable 2-GRC-S594 04-04-06 R0266439 Acceptable 2-GRC-S596 04-04-06 R0266439 Acceptable 2-GRC-S598 04-04-06 R0266439 Acceptable 2-GRC-S599 04-18-06 R0266439 Acceptable 2-GRC-S609 04-04-06 R0266439 Acceptable 2-GRC-S611 04-04-06 R0266439 Acceptable 2-GRC-S623 04-04-06 R0266439 Acceptable 2-GRC-S624 04-18-06 R0266439 Acceptable 2-GRC-S626 04-04-06 R0266439 Acceptable 2-GRC-S629 04-04-06 R0266439 Acceptable 2-GRC-S630 04-04-06 R0266439 Acceptable 2-GRC-S632 04-04-06 R0266439 Acceptable 2-GRC-S631 04-04-06 R0266439 Acceptable 2-GRC-S587 04-04-06 R0266439 Acceptable 2-AFW-S4023 04-13-06 R0266100 Acceptable 2-AFW-S4024(L) 04-13-06 R0266100 Acceptable 2-AFW-S4024(U) 04-13-06 R0266100 Acceptable 2-AFW-S4021 04-13-06 R0266100 Acceptable 2-AFW-S4028(L) 04-13-06 R0266100 Acceptable 2-AFW-S4028(U) 04-13-06 R0266100 I Acceptable 18

INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.

UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 Snubber VT-3 Visual Examinations (Continued)

Snubber No. Exam Date Job Order No. Results 2-AFW-S4027 04-13-06 R0266100 Acceptable 2-AFW-S4025 04-13-06 R0266100 Acceptable 2-AFW-S4031 04-13-06 R0266100 Acceptable 2-AFW-S4032(L) 04-13-06 R0266100 Acceptable 2-AFW-S40.32(L_ 04-13-06 R0266100 Acceptable 2-AFW-S4029 04-13-06 R0266100 Acceptable 2-AFW-S4036(L) 04-13-06 R0266100 Acceptable 2-AFW-S4036(U) 04-13-06" R0266100 Acceptable 2-AFW-S4035 04-13-06 R0266100 Acceptable 2-AFW-S4033 04-13-06 R0266100 Acceptable 2-GBD-S563(L) 04-12-06 R0266147 Acceptable 2-GBD-S563(U) 04-12-06 R0266147 Acceptable 2-GBD-S569(L 04-12-06 R0266147 Acceptable 2-GBD-S569(U) 04-12-06 R0266147 Acceptable 2-GBD-5S68 04-12-06 R0266147 Acceptable 2-GCCW-S840 02-28-06 R0263765 Acceptable 2-GCCW-S843 02-28-06 R0263765 Acceptable 2-OME-3-1-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-IL 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-3L 04-03-06 R0265677 Acceptable 2-OvE-3-2-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-IL 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-1L 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD- 1L 04-03-06 R0265677 Acceptable 19

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI.

COMMERCIAL SERVICE DATE 7-1-1978 Snubber Functional Tests Snubber No. Test Date Job Order No. Results Remarks 2-GRC-S538 04-18-06 R0098999 Accept. Small Bore Grinnell 2-GRC-S555 04-19-06 R0099679 Accept. Small Bore Grinnell 2-GRC-S573 04-20-06 R0036212 Accept. Small Bore Grinnell 2-GRC-S611 04-19-06 R0036210 Accept. Small Bore Grinnell 2-GBD-S568 04-20-06 R0037674 Accept. Small Bore Grinnell 2-GCCW-S843 04-17-06 R0037685 Accept. Small Bore Grinnell 2-AFW-S4032-U 04-20-06 R0036689 Accept. Small Bore Grinnell 2-OME-3-4-HSD-IL 04-08-06 R0078801 Accept. Large Bore 2-OME-3-4-HSD-1U 04-07-06 R0100166 Accept. Large Bore 2-OME-3-4-HSD-3L 04-09-06 R0037382 Accept. Large Bore 2-OME-3-4-HSD-3U 04-08-06 R0058565 Accept. Large Bore The minimum 14% required sample size consists of 7 small bore (Grinnell) and 3 large bore (Steam Generator) snubbers.

20

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 6 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR ASME SECTION XI, SUBSECTIONS IWE AND IWL Containment Inservice Inspections During the reporting period of November 10, 2004, to May 4, 2006, inservice inspections were performed on the Unit 2 Containment pressure retaining structure in accordance with Subsections IWE and IWL of ASME Section XI, 1992 Edition and 1992 Addenda, and 10 CFR 50.55a.

The following attachment provides a listing of the examinations performed, results, and corrective actions, if any were performed. A General Visual Examination was performed on all accessible surfaces of the Containment liner along with examinations performed in conjunction with coating repairs, and other repair/replacement activities.

An acceptance criteria providing the acceptable minimum thickness of the containment liner was established for the examination of the concrete-backed liner. The examination results were compared to the acceptance criteria. All results were within the established acceptance criteria. No areas required to be classified as an Augmented Examination area in accordance with IWE-1240.

Containment concrete examinations are currently in progress as of this report date. No degradation has been found that impacts the structural integrity of the containment concrete. As of this report date, there have been no conditions noted in accessible areas that could indicate the presence or result in degradation to inaccessible areas.

21

Program Owner: (14,,. 2A, NIS-1 Attachment 7 Evaluation of IWE As-Found Condition Examination Results Date: _'-0--o0:,

3125/2006 2 KuzLUI_ ,cones /- -1u/*,(paaZ-b14-lIA, z-1 Z-1 ZA (uenerai None 03 (partial) Visual _______________

Accept

_________

3/25/2006 2 R0246391- Moisture Barrier 2-598-MB (RCDT Area) VT-3 3/25/200612 02 02 ______________ None Accept General' None Accept 3252006 2 R0246391- Zones 2-598-26, 2-598-27 (partial) Visual NoneAccept R0266500al 3/2612006 2 R0266500- Penetration Bolting 2-CPN-80-BOLTING VT-1 None 49 Accept 3126/2006 2 R0266500- Penetration Bolting 2-CPN-57-BOLTING VT-1

_________48 None Accept Prior to coating repair: Liner and penetrations between fence at RCDT to Col. 21 and from 3/28/2006 05132069- floor up approx. 3' and penetrations up to the 01 2nd weld channel (areas of damaged paint). VT-3 None Accept Areas between Cols. 21 and 23 and from the floor up to the 2nd weld channel including penetrations (areas of damaged paint)..

05132069- Prior to coating repair: Zone 2-598-27 (partial) Four small areas, approx. 112" 3/30/2006 2 07 from gate at Col. 27 to concrete, floor elevation VT-3 diameter with chipped top coat. Accept up approx. 9'-0". No base metal wastage.

3/30/2006 2 R0246391- Moisture Barrier 2-598-MB (Annulus area) VT-3 None 1 04 1- . I Accept I I

References:

1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 22

Program Owner:_ q&. a A ." NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date: 7-Jo-Oh r-lI L.u IU UA:LIII*

191 U dII LUIU

-0u. 4-0 14-4-, r-L. OVU down to EL. 642', 10'-0" east of divider barrier seal. Zone 2-612-25B EL. 642' down to EL.

627', 12'-0" east of divider barrier seal. Zone 2-612-25A EL. 627' down to EL. 612', 12'-0" 05132069- divider barrier seal to Column 26. Zone 2-612- Peeling paint, delamination of 3/31/2006 2 26A EL. 612' up to approx. EL. 622' from 05 VT-3 top coat, discoloration. No liner Accept Column 26 to 27. Zone 2-612-27A EL. 612' up plate degradation noted.

to approx. EL. 622' from column 27 to divider barrier seal. Zone 2-612-1 EL. 612' up to EL.

637' from divider barrier seal to Column 1. Zone 2-612-28A. Zone 2-612-28B EL. 627' to EL.

637'. I I

I I

I I

References:

1)NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 23

Program Owner: NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_ 7 4- ,

/-ones,-598-6, 2-598-7, 2-598-8, 2-598-9, Z-598-5, 2-598-6, 2-598-7, 2-598-8, 2-598-9, 2-598-10, 2-598-11, 2-598-12, 2-598-13, 2-598-14, 2-598-15, 2-598-16, 2-598-17, 2-598-18, 2-598-19, 2-598-20, 2-598-21, 2-598-22, 2-598-23, 2-598-24, 2-598-25, 2-598-27 (partial), 2-612-2, 2-612-3, 2-612-4, 2-612-5, 2-612-6, 2-612-7, 2-612-8, 2-612-9, 2-612-101B, 2-612-11 B, 2-612-12A, 2-612-122B, 2-612-13A, 2-612-13B, Discoloration noted. No evidence R0246391- 2-612-14A, 2-612-14B, 2-612-15A, 2-612-15B, 3131/2006 2 04 2-612-16, 2-612-17, 2-612-18, 2-612-19, 2-612- General of degradation that may affect Accept 20, 2-612-21, 2-612-22,2-612-23, 2-612-24, 2- Visual either containment structural 612-25A, 2-612-25B, 2-612-25C, 2-612-26A, 2- integrity or leak tightness.

612-26B, 2-612-26C, 2-612-27A, 2-612-27B, 2-612-27C, 2-612-28A, 2-612-28B, 2-612-1, 2-650-1A, 2-650-11B, 2-650-1C, 2-650-2A, 2-650-2B, 2-6.50-2C, 2-650-3A, 2-650-3B, 2-650-3C, 2-650-4, 2-715-IA, 2-715-1B, 2-715-IC, 2-715-2A, 2-715-2B, 2-715-3, 2-745-001, 2-757-001, Inspection Ports: 2-PORT-01, 2-PORT-02, 2-PORT-03 4(5/2006 05132069- Prior 627'totopaint removal: Instrument 03 ceiling and Azimuth 262 toRoom EL.

divider VT-3 Slight flaking and discoloration.

No liner degradation noted. Accept barrier seal.

Prior to coatings removal: Containment Penetration 2-CPN-4 at first weld towards 4/512006 2 R0257113- containment from the #1 cooler to the radius VT-3 Slight discoloration. Accept 02 transition at the pipe end. Area of inspection edge of the toe of the welds described above.

References:

1)NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 24

ProgramO NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_7-C20...-c4, 05132069- Peeling paint, delamination, light 4M7/2006 2 Prior to surface prep: Zones 2-612-20, 2-612-21 VT-3 discoloration, surface rust. No 02 Accept evidence of liner degradation.

Liner surfaces behind divider barrier seal when seal segment is removed: Zone 2-612-2 Seal sample #1, between Columns 2 - 3, area approx. 3'-0" wide, 5'-0" high, starting approx. 8" No evidence of degradation that R0265946- up from seal. Existing gap of <114" wide with General may affect either containment 418/2006 2 06 internal obstructions prevent view of attachment Visual structural integrity or leak weld. Zone 2-612-24 Seal sample #2, area Accept tightness noted on viewable approx. 2'-0" wide, 2'-0" high, starting at surfaces.

attachment weld. Existing gap of approx. 1/4" wide at one location with internal obstructions prevent view of surfaces Prior to paint removal: Zone 2-650-1A Liner Light discoloration. No liner plate 4113/2006 2 05341030- plate surfaces surrounding the following Vr-3 03 penetrations, and penetration surfaces: 2-CPN- or penetration surface degradation Accept or wastage noted.

56, 57, 65, 80, 83, 86... degradation or wastage noted Prior to coatings removal: Containment Penetration 2-CPN-2 at first weld towards 4/15/2006 2 R0257111- containment frompipe the end.

  1. 1 cooler to inspection the radius 02 transition at the Area of VT-3 Discoloration and flaking. No pisotration adakin no Accept 360 deg. Around penetration and 1/2" from the edge of the toe of the weld and transition described above.I

References:

1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 25

Program Owner:a NIS-1 Attachment Evaluation of WE As-Found Condition Examination Results Date:_7--o-- ,

rIuIi.v L '+luriys iwerijlvdii LjUILaIrlII*IrIL Penetration 2-CPN-5 at first weld towards 4(15(2006 R0257114- containment from the #1 cooler to the radius 2 Slight discoloration. No 02 transition at the pipe end. Area of inspection VT-3 Accept penetration degradation noted.

360 deg. Around penetration and 1/2" from the edoe of the toe of the welds described above.

4/22/2006 2 R0246T08- Outer and inner equalizing valves. VT-3 None Accept 2-AIRLOCK-C650 electrical penetration bolting 4124/2006 2 R0267461- for inner and outer doors, both sides. 2-02 UPLODE-BOLTING (16), 2-UPLIDE-BOLTING VT-1 None Accept V

I 1 1 (16)_

References:

1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 26

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 7 ABSTRACT OF EXAMINATIONS, RESULTS AND CORRECTIVE ACTIONS FOR STEAM GENERATOR EDDY CURRENT EXAMINATIONS 2004 Steam Generator In-Service Inspections During October of 2004, eddy current inspections were conducted on the Unit 2 steam generators. Based upon the favorable results of this inspection and in accordance with the provisions of Technical Specification 4.4.5.3a, the Unit 2 steam generators continue to be on an inspection interval of up to 40 calendar months. As such, the Unit 2 steam generators will next be inspected in the fall of 2007.

27

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 8 NIS-2 REPAIR AND REPLACEMENT INDEX 28

U2C16 RepairReplacementReport Job Order Description Component Code Class R0099679-01 2-GRC-$555, REPLACE SNUBBER 2-GRC-$555 1 04305061-04 2-PP-50E, REPLACE PUMP W/ SS PUMP 2-PP-50E 2 04318017-01 2-MRV-232, REPAIR LEAK (INTERNALS, BIB BOLTING) 2-MRV-232 2 R0238854-13 2-VCR-20, REPLACE BONNET/BOLTING 2-VCR-20 2 R0266622-05 2-SV-45A, REPLACE SAFETY VALVE 2-SV-45A I 05340018-01 2-CS-536, REPLACE INTERNALS 2-CS-536 2 05340007-01 2-CS-534, REPLACE INTERNALS 2-CS-534 2 05340017-01 2-CS-535, REPLACE INTERNALS 2-CS-535 2 04322047-01 2-OME-4, REPLACE MANWAY BOLTS 2-OME-4 1 R0036212-01 2-GRC-S573; REPLACE SNUBBER 2-GRC-$573 1 R0098999-01 2-GRC-S538, REPLACE SNUBBER 2-GRC-$538 1 05340020-01 2-SI-210, REPLACE BOLTING 2-SI-210 2 R0246231-01 2-SV-104E, REPLACE BOLTING 2-SV-104E 2 R0036689-01 2-AFW-S4032-U, REPLACE SNUBBER 2-AFW-S4032-U 2 02346033-12 2-MRV-223, REPLACE BOLTING 2-MRV-223 2 05336016-01 2-MRV-242, REPLACE INTERNALS 2-MRV-242 2 06013029-13 2-PP-50W, CUT/REPLACE PIPE WELD 2-PP-50W 2 06040073-01 2-PP-50W, REPLACED GLAND PLATE/BOLTING 2-PP-50W 2 R0240871-01 2-CCR-457, REPLACE INTERNALS 2-CCR-457 2 04305061-28 2-PP-50E, INSTALL CCP SUCTION PIPING 2-PP-50E 2 04305061-27 2-PP-50E, INSTALL CCP DISCHARGE PIPING 2-PP-50E 2 R0226722-01 2-SV-104W, REPLACE VALVE AND BOLTING 2-SV-104W 2 R0037674-01 2-GBD-S568, REPLACE SNUBBER 2-GBD-S568 2 05121006-01 2-NRV-153, REPLACE INTERNALS 2-NRV-153 1 05237040-17, 2-OME-4, WELDED PREEMPTIVE WELD OVERLAYS 2-OME-4 1 18,22,23,27,28 ON DISSIMILAR METAL WELDS ON SAFETY, RELIEF, 32,33,37,38,43 SPRAY, AND SURGE NOZZLES 29

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 9 NIS-2 REPAIR AND REPLACEMENT REPORTS 30

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/19/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GRC-S555 Name One Cook Place, Bridngman, MI 49106 JOB ORDER No. R0099679-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridclman. MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, P0) ed (Yes or No) 2-GRC-$555 SNUBBER GRINNELL M&E 30-024683 N/A S/N 33021 N/A Replacement NO ASP 30610 SEAL KIT GRINNELL M&E 30-025055 N/A N/A N/A Replacement NO ASP 30463 "A" SEAL KIT GRINNELL M&E 30-040590 N/A NIA N/A Replacement NO ASP 28096 PISTON BUSHING GRINNELL M&E 30-024790 N/A NIA N/A Replacement NO ASP 16978
7. Description of Work REPLACED SNUBBER WITH REBUILT
8. Test Conducted: Hydrostatic D Pneumatic [] Nominal Operating Pressure D Other nX VT-3 Pressure NIA psi. Test Temp. NIA F INI T 31

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File R0099679-01

9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC EMENT conforms to the rules of the ASME Code, Section XN. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed n4l')ý Maintenance Weldina Supervisor Date 0

,2O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS - h ve Inspected the components described in this Owner's Report during the period to 6*/,,24'-, , and state that to the best of my knowledge and belief, the Owner has p&rforrned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in ankynanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspejtioit./

j imissions Af/ 6e76rV7-f

.ctor's Signalure National Board, State, Province, and Endorsements

,/,/,gZ- 20Q6 3a-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/14/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50E Name One Cook Place. Bridqman, MI 49106 JOB ORDER No. 04305061-04 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ASME SEC III CL2 1986 Ed, N/A Add. Code Case.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989,. No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50E PUMP N/A M&E 30-014849 NA ASME SA1 82 N/A REPLACED YES CASING ASP 31062 TP304
7. Description of Work REPLACED PUMP
8. Test Conducted: Hydrostatic F-- Pneumatic 1 Nominal Operating Pressure Other F INSERVICE VT-2 Pressure psi. Test Temp. _ F

-33

Page 2 of 2 FORM KIS-2 (Back)

Job Order/File 04305061-04

9. Remarks: Inservice VT-2 performed.

Applicable Manufacturer's Data Reports to be attached Serial# 05RLCA0321501001 DWG. 017571 Model2.5"RLIJ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Dew ne Trmns Mainter tance Welding Supervisor Date __/04 05_,204 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS / . have inspected the components described in this Owner's Report during the period '? to .5// . I and state that to the best of my knowledge and belief, the Owner hali perlormed; examinations'and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable inmny manner for any personal injury or properly damage or a loss of any kind arising from or connected with this =r.i.

Commissions AI.6 6e77 iff/ ':S/A7 r"'

National Board, 9tafe, Province, and Endorsements Inspec--or Signf lur Date 20 3,-I

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code, Section Ill, Division 1 2 Pg. I of.. "" ""

I. Manufacired and certifie* -'ve Pump Division, Nuclear Products Operation 2300 E. Vnmon Ave. Vernon, CA 90)05 (name and address of NCertificate Holder)

2. Manufactured forAmerican Elctric Power, Material Center,9970 Red Arrow ighwayBridgan,M]. 49106 Irama and address of Purchased Electric Power, D.C. Cook Plan4, 0;Cook .Pate,Bnidgman, M 60450
3. Location of C (name and address)
4. Model No., Series No., or Type 2.5"RL Drawing DWG17571 B CRN A 1986 W86 2 NA
5. ASME Code, Section 111,Division 1:

fedition) laddende date) (class) (Code Case no.)

Nominal Inlet size " Outlet size 3 1/8"

6. Pump or valve Pump (in.) (in.)

NA Disk NA BoNAtng NA

7. Material: Body NBonnet

[a) (b) Ic) Id) le)

Cert. Nat'l Body Bonnet Disk H.older's Board., . Serial serial Serial Serial No. No. No. No. No.

05RLCA0321501001 NA NA NA NA Supplemental information In form of lists. sketches. or drawings may be used provided (1) size is BY& X 11. (2) Information in itein'1 through 4 on this Data Report Is Included on each sheet. (3) each sheet is numbored and the number of sheetss rencorded at the top of this form' (1.2188) This form (EDD0371 may be obtained from the Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300. REPRINT GM I

  • .-. -z ---

~ ., ,

0351)

.,_ =. ....

-o. ............. FFORM NPV-1. (Back - Pg. 2 of. O A21 Certificate Holder's Serial No. 05LA0321501001

8. Design cond'citions *f psi 300 IF or valve pressure class NA (1l (prea*srel ltemperature)
9. Cold workInj'-ssjre NA psi at i"OOF
10. Hykirostatic test 52601400 psL Disk differential test pressure NA psi
11. Remark.. Namplate attacbed by dCive pis.

Job Number: RLCA03215 Prodaction Order: RLSA08607

  • D 'i:CERTIFICATION OF DESIGN Design Specification certified by AlbeTt John Wettlaufer P.E. State PA Reg. no. 13335-E Design Report certified by D. G. Bowman P.E. State CA Reg. no. NA CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No N14130 JeIres Jte] 0, 2008 D 321/o6 - erv Pump Division, Nuclear Products Ope- ed IN Certificate Holderd (aUt.ot re.........e CERTIFICATE OF INSPECTION I. the undersigned, holding a valid'commission issued by the National Board of Boiler and Pressure Vessel Inspectc;rs and the State or Province of Caffoania and employed by HSB-CT of Har-forL CT' have inspectea the pump, or valve, described in this Data Report on 32121/2006 , and state that to the best of my knowledge and belief. 1ie Certificate Holder has corn structed this purrp*.or valve, in accordance with the ASME Code, Section IIl, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or ss of any kind arising from or connected with this Inspection.

Date 3/21/2006 Signed .. OCommissions (Authorized Int ector)

CA 1969 rind. andorsemerits) and Suite or proy. and no.]

lNatL Betd.

(1) For manually operated valves only.

SIMP REVIEWiED AND ACCEPTED .

DA 15 10

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/22106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-MRV-232 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 04318017-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. Ml 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 NIA Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-MRV-232 STEM N/A M&E 30-688864 N/A ASTM A276 N/A REPLACED NO ASP 28532 TP 316 PLUG N/A M&E 30-688864 N/A ASTM A582 N/A REPLACED NO ASP 28532 TP 416 CAGE N/A M&E 30-688865 N/A ASTM A747 N/A REPLACED NO ASP 17265 CB7CU-1 1/2" STUD M&E 30-688868 N/A ASTM A193 N/A REPLACED NO MATERIAL ASP 28601 GR B7 1/2" NUT M&E 30-688869 N/A ASTM A194 N/A REPLACED NO ASP 28601 GR2H
7. Description of Work REPLACED STEM, PLUG AND BONNET BOLTING
8. Test Conducted: Hydrostatic s1 Pneumatic ] Nominal Operating Pressure Other __Pressure psi. Test Temp. _ F 37

'NIT-4

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 04318017-01

9. Remarks:.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed ýhievrIM4VDIPTI_ý Owner or Owner's Designee, Title Maintenance Welding Supervisor Date r P " 20 i CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period ____ ______to ...-- /,. and state that to the best of my knowledge and belief, the Owner has performed examinations 6nd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti

  • Commissions X18 Inspedor's Signature' "*L___. National Board, State, Province, and Endorsements Date__ _ _

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/17/06 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-VCR-20 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. R0238854-13 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: ICE CONDENSER SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case N-522 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-VCR-20 VALVE BONNET N/A M&E 30-039707 NA ASTM A445 N/A REPLACED NO ASP 31147 66T

/2k NUT N/A M&E 30-212070 NA ASME SA194, N/A REPLACED NO ASP 22002 GR 8F Y2' STUD N/A M&E 30-040599 NA ASME SA 453 N/A REPLACED NO MATERIAL ASP 27052 GR 660

7. Description of Work REPLACED BONNET ASSY AND BOLTING.
8. Test Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D-]

Other D APPENDIX J TEST PER CC N-522 Pressure psi. Test Temp. F 3q IN~F~

Page 2 of 2 FORM4 NIS-2 (Back)

Job Order/File R0238854-13

9. Remarks: APPENDIX J TEST PER CC N-522 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A rin

ý rýM Signed TThwavn~ Maintet niance Weldino Supervisor Date 220 4-d5 onsDesignee, aintenance Title Welding SUDervisor v or Ownerv;a n Owner's

?e--Tri V-'e4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS , / bave inspected the components described in this Owner's Report during the period to ,and state that to the best of my knowledge and belief, the Owner trs p6rformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and ffective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be lia n any manner for any personal injury or property damage or a loss of any kind arising from or connected with th s ction.

Commissionsjf 9 , qw National Board,1State, Province, and Endorsements 9/0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/14106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SV-45A Name One Cook Place, Bddcman. MI 49106 JOB ORDER No. R0266622-05 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed. N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of. Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SV-45A SAFETY VALVE CROSBY M&E 30-036392 NA S/N N/A REPLACED NO ASP 30673 RV-1-8010A
7. Description of Work REPLACED VALVE
8. Test Conducted: Hydrostatic D Pneumatic Nominal Operating Pressure

. t..hOher- . VT-2 at NOP/NOT, VT-3 Pressure psi. Test Temp. F i7-/

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File R0266622-05

9. Remarks: NOP/NOT VT-2 performed. VT-3 on internals Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed mons Maintenance Weldina Suoervisor r I Date ,20 6" Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period Z/,* to ,Z/,ll/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7227...............

Commis*sions m, 16/9*- //~,

spector's Sigr dure National Board, State, Province, and Endorsements Date 20 66 2,_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date ' 04/09106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CS-536 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05340018-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A

. Address

4. Identification of System: , CHEMICAL AND VOLUME CONTROL S' YSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification o f Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component .Manufacturer Serial No.' Board Ideteification Built Replaced, Code (Material M&E. No. or Replacement Stamped ASP, PO) (Yes or No) 2-CS-536 VALVE CENTER N/A M&E 30-033374 NA ASME SA479 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY
7. Description of Work REPLACED C:ENTER SECTION ASSEMBLY
8. Test Conducted: Hydrostatic 0 Pneumatic 1- Nominal Operating Pressure Other M Pressure psi. Test Temp. _ F INr q3

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 05340018-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed ae wiemmons ... .. ... .. . .

ce . .. lin ... -- -o r"

..... .

Date elin uorisr M~ntnnc ,20696 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS / have inspected the components described in this Owner's Report during the period __ ____-_-_____ _to le-*7 d('. , and state that to the best of my knowledge and belief, the Owner has performed examinations and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in a manner for any personal injury or. property damage or a loss of any kind arising from or connected with this inspec Commissions {,'d y2 ///

) National Board, State, Pr6vinime, and Endbrsements

/ q/q

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC IPOWER Date 04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CS-534 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05340007-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: CHEMICAL AND VOLUME CONTROL SYSTEM ISI CLASS 2
5. (a) Applicable Const Code ANSI B31.1 1983 Ed, NIA Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-CS-534 VALVE CENTER N/A M&E 30-013933 NA ASME SA579 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY
7. Description of Work, REPLACED CENTER SECTION ASSEMBLY
8. Test Conducted: Hydrostatic l Pneumatic -- Nominal Operating Pressure 1 Other F1 Pressure . psi. Test Temp. _ F

?fl

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 05340007-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A 4

Signed intenance Weldina Suoervisor Date 4e,? 7-. ,2092

.1 Owner or Owner's Designee, Title I

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON. TEXAS / havye inspected the components described in this Owner's Report during the period /j/..///4. to - and state that to the best of my knowledge and belief, the Owner ha's peff6rmed examinationVsard taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectiop.

,missions AJA O!nr -§/9. 2 L

.. 2 7c

'/4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner AMERICAN ELECTRIC POWER Date 04109)/O6 Name P.O. Box 60 Fort Wayne. IN 46B01 Sheet I of 2 Address Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CS-535 Name One Cook Place, Bridgman, MI 49105 JOB ORDER No. 05340017-01 Address Repair Org. P.O. No., Job No., etc

3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A Onp Ccnnk Plhqn Bridnman. MI 4910B Expiration Date N/A Address
4. Identification of System: CHEMICAL AND VOLUME CONTROL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda S. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-CS-535 VALVE CENTER N/A M&E 30-013933 NA ASME SA479 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY
7. Description of Work REPLACED CENTER SECTION ASSEMBLY
8. Test Conducted: Hydrostatic M Pneumatic D Nominal Operating Pressure Other [-"] Pressure psi. Test Temp. _ F lWlT5

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 05340017-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are crrect and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed M~int~n~nce W~Idino Suoeivisor Date "ze2 20 Owner or Owner o Owner's Owner'stenance Desiig neerT.t Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS havedinspected the components described in this Owner's Report during the period /__ -____to -. .- , and state that to the best of my knowledge and belief, the Owner has performed examinations ar'd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecfibo

- -- -. -

f&

~~--Comr issionls A 6 i ~/3£V?

Inspector's Signature " P National Boar, State, Pr-vitnd, -a-a-E-o--o-en-t z Date C"/hs 205

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 11/21 1/04 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-OME-4 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 04322047-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106

.... ...... ..... i I 1 Expiration Date N/A Address

4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ASME SEC. III 1986 Add. Code Case (b) Applicable Edition bf Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-OME-4 PRESSURIZER MANWAY BOLT N/A M&E 30-009772 NA ASME SA193 N/A REPLACED NO ASP 16387 GR B7
7. Description of Work REPLACED 2 BOLTS AT MANWAY
8. Test Conducted: Hydrostatic [, Pneumatic R- Nominal Operating Pressure LI1 Other "- VT-2, VT-1. PT Pressure A'OP psi. Test Temp. Žv.OQ F

-jjj Wrr- Jv-bý2

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 04322047-01

9. Remarks: VT-I, VT-2 and PT performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed D 0yne hmmons Owner or Owner's Designee, Title Maintenance Weldina Suoervisor

.... 1 i* -- [ .. ....

Date 40ý 21, 2 0 6; I

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Ves~el Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS , , haye inspected the components described in this Owners Report during the period 4 7E Y to and state that to the best of my knowledge and belief, the Owner has 15erforfned examinations 'and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in an manner for any personal injury or property damage or a loss of any kind arising from or connected with this insm .oi.

/"

,5-0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/20/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GRC-S573 Name One Cook Place, Bridgman, M1 49106 JOB ORDER No. R0036212-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, NIA Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-GRC-S573 SNUBBER GRINNELL M&E 30-024683 N/A SIN 33294 N/A Replacement NO ASP 30495 SEAL KIT GRINNELL M&E 30-025060 N/A N/A N/A Replacement NO ASP 26432 "A" SEAL KIT GRINNELL M&E 30-040591 NIA N/A N/A Replacement NO ASP 28476 ROD BUSHING GRINNELL M&E 30-024791 NIA GRINNELL N/A Replacement NO ASP 30165
7. Description of Work REPLACED SNUBBER WITH REBUILT
8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure Other F11 VT-3 Pressure NIA psi. Test Temp. NIA F 51

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File R0036212-O1 0 MOrnn-.. a.U..n~

/rr_*

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC EMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type.Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed D e V;rieýo ns~ itenance Weldinri Supervisor Date .20 2,0 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS ./ , .. hayv inspected the components described in this Owner's Report during the period to ,A_0/!//i'6o4 , and state that to the best of my knowledge and belief, the Owner has pOrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i econ.

Commissions 7 0 c 17.

National Board, State, Province, and Endorsements Date

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/19106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GRC-S538 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. R0098999-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place,. Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM IS[ CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-GRC-S538 SNUBBER GRINNELL M&E 30-024681 N/A S/N 33020 N/A Replacement NO ASP 29340 SEAL KIT GRINNELL M&E 30-025055 N/A N/A NIA Replacement NO ASP 17001 "A" SEAL KIT GRINNELL M&E 30-040590 N/A N/A N/A Replacement NO ASP 21030
7. Description of Work REPLACED SNUBBER WITH REBUILT
8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure D Other I VT-3 Pressure N/A psi. Test Temp, N/A F 5-3 INIT-

Page 2 of 2 FOR~M NIS-2 (33ack)

Job Order/File RD09899MlO

9. Remarks:, Vr-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Signed ,

66,~rrn'

-- .... r.* ................

4 2 Maintenance Weldina Suoervisor f

... .. .. f n Date ,20 200, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS /. hýe inspected the components described in this Owner's Report during the period W O'//,5- to: e//l/V1, , and state that to the best of my knowledge and belief, the Owner has performed examinations~and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable,

  • any manner for any personal injury or property damage or a loss of any kind arising from or connected with this kts6)ction.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date ' 04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801 Rh__f 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SI-210 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05340020-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date NIA Address
4. Identification of System: SPENT FUEL POOL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XA Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SI-210 VALVE W THREADED N/A M&E 30-212280 NA ASME SA453 N/A REPLACED NO ROD ASP 23399 GR 660 1/" HEX NUT N/A M&E 30-212070 NA ASME SA194 N/A REPLACED NO ASP 22002 SA194, GR I 8FGR 8F
7. Description of Work REPLACED BONNET BOLTING 8.. Test Conducted: Hydrostatic D Pneumatic -" Nominal Operating Pressure Other D Pressure psi. Test Temp.. F INIT 9.

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 05340020-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed Maintenance Welding Supervisor Date e,, . 20 '

Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC.. of HOUSTON, TEXAS h ve spected the components described in this Owners Report during the period ,s

ýe C to e) and state that to the best of my knowledge and belief, the Owner h~s Performed examinations an6 taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins tiotn.

./t

.-

,c.,,,,..- Commissions /,6,1'7 /// a,---

........ Inspector's-Signature-- National Board, Stafe, Province, and Endorsements Date C/e' 206:r

FORM NIS-2 OWNER'S REPORT FOR-REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/19/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SV-104E Name One Cook Place, Bridgqman, M1 49106 JOB ORDER No. R0246231-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. NIA One Cook Place. Bridoman. MI 49106

.............. i .... i f ...... i - .- , .

Expiration Date N/A Address

4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1992, Addenda 92
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SV-104E 5/8"THREADED N/A M&E 30-212290 NA ASME SA453 NIA REPLACED NO ROD ASP 29520 GR 660 5/8' NUTS NIA M&E 30-212090 NA ASME SA194 NIA REPLACED NO ASP 30787 GR8F 5/8' NUTS NIA M&E 30-212089 NA ASME SA194 N/A REPLACED NO ASP 25904 GR 8M
7. Description of Work REPLACED BOLTING
8. Test Conducted: Hydrostatic "- Pneumatic F-1 Nominal Operating Pressure [l Other D'] INSERVICE VT-2 Pressure psi. Test Temp. F 1

lNtTr

.27WOe/'

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File R0246231-01

9. Remarks: Inservice VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR& REPLACEMENT conforms to the rules of the ASME Code, Setrion X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expirati on Date N/A Signed DeWnevm M~int~n~nr~ W~ldinr, ~nr~rvkor Date ,-*.-_-. ? 20 £9 0 Maintenance Weldinn Sunerviso Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS f I- haveinspected the components described in this Owner's Report during the period -__.vlorl to , /, and state that to the best of my knowledge and belief, the Owner has performed examinations an(I taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insp$con.

Commissions AMe 6z17 7.,tz--

0/ (3and National Board, State, Province, (5(7,9 Endorsements Date '*,-a 20 d r.

5-7

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/20/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-AFW-S4032-U Name One Cook Place, BridQman, MI 49106 JOB ORDER No. R0036689-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqrnan, MI 49106 Expiration Date N/A Address
4. *Identification of System: FEEDWATER SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed. N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, *No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-AFW-4032-U SNUBBER GRINNELL M&E 30-024683 N/A S/N 32463 N/A Replacement NO ASP 29372 SEAL KIT GRINNELL M&E 30-025060 N/A NIA N/A Replacement NO ASP 26432 "A" SEAL KIT GRINNELL M&E 30-040591 N/A NIA N/A Replacement NO ASP 28476
7. Description of Work REPLACED SNUBBER WITH REBUILT
8. Test Conducted: Hydrostatic -- Pneumatic [_] Nominal Operating Pressure I Other F11 VT-3 Pressure NIA psi. Test Temp. N/A F 51 INff~

1'f A

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File RO0366Sg.M1

9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC EMENT conforms to the rules of the ASME Code, Section XN . repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ;4weavnZ0imm(Qhs Meaintenance Weldina Sunervisor Date ",Av ' 20 e Owner orbOwners Designee, Title I

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michioan and employed by ABS GROUP INC. of HOUSTON, TEXAS , t. hav/einspected the components described in this owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner hIasj frformed examinations-dni taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabJe1i any manner for any personal injury or property damage or a loss of any kind arising from or connected with thirs tion.

/(~G*

issA~

Cmkions w /46? 6i-Y /4  ::?,ic-~

Stat* Province, and Endorse-rnen*

ff

  • I .
  • w F Inspector's SgnaW// National Board, Board, State,~ Province, K and EndorsementsI Date cý 20 F6 10D

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/22/06 Name P.O. Box 60 Fort Wayne, iN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-MRV-223 Name One Cook Place. Bridaman. MI 49106 JOB ORDER No. 02346033-12 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization" No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM IS1 CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-MRV-223 1" BOLT M&E 30-039909 N/A ASME SA193 N/A REPLACED NO ASP 29981 GR B7 1" NUT M&E 30-039910 N/A ASTM A194 NIA REPLACED NO ASP 29981 GR 2H
7. Description of Work REPLACED BONNET BOLTING
8. TestConducted: Hydrostatic F Pneumatic F-] Nominal Operating Pressure F-1 Other L] Pressure psi. Test Temp. _ F lNITZ--f

Page 2 of 2' FORM NIS-2 (Back)

Job OrderlFile 02346033-12

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed De1Ivn~mon Maintenance Welding Supervisor Date 20 2Q.,*

Owner or Owner's Designee, Title

  • CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS have ispected the components described in this Owner's Report during the period to ""-/-- , and state that to the best of my knowledge and belief, the Owner has performed examination" and' taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exafninations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti n.

1//§ _ ___ Commissions t'%7,Y // " -

SB-National /S ', , -".and Endorsements

-rovince, 6oziard/StatePoi& ndrent

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date . 04/06/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-MRV-242 Name One Cook Place, BridQman, MI 49106 JOB ORDER No. 05336016-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM IS!CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-MRV-242 VALVE CAGE M&E 30-688865 N/A ASTM A747 N/A REPLACED NO ASP 27541 CB7CU SEAT RING M&E 30-040120 NIA ASTM A582 N/A REPLACED NO ASP 30215
7. Description of Work REPLACED CAGE AND SEAT RING.
8. Test Conducted: Hydrostatic 1 Pneumatic Lý . Nominal Operating Pressure F-1 Other _- _ Pressure psi. Test Temp. _ F

[Nnr4s

Page 2 of 2 FORM H-IS-2 (Back)

Job Order/File 05336016-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Exiration Date N/A Signed DL4a ?Vne-pZ s Moi ntenance Weldina Suoervisor Date ,20 6' Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS I ý have'nspected the components described in this Owner's Report during the period 0 .1/14./Oq to a, and state that to the best of my knowledge and belief, the Owner 6as ferformed examinatlorf and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examination ando rrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be b in any manner for any personal injury or property damage or a loss of any kind arising from or connected with i pection.

1>;

... ....... m/ , .,-

Uommlssions' ~" I ' l1 ' _ 1:

1 National Board: State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/01106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50W Name One Cook Place, Bridqrman, MI 49106 JOB ORDER No. 06013029-13 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type.Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date NIA Address
4. Identificafion of System: EMERGENCY CORE COOLING SYSYEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case N-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50W WELD FILLER N/A M&E 30-044990 NA ER 308/308L N/A REPLACED NO MATERIAL ASP 29426 &

29734

7. Description of Work CUT WELD FOR ACCESS AND REWELDED
8. Test Conducted: Hydrostatic 0 Pneumatic NominalOperating Pressured Other F-] PT, RT. VT-2 SYSTEM LEAKAGE Pressure psi. Test Temp.

F INIT

Page 2 of 2 FORK NIS-2 (Back)

Job Order/File 06013029-13

9. Remarks: Reweld after cutout. PT, RT, VT-2 performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed -wavng"rimrmons Maintenance Welding Suoervisor Date , .20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS'GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period Zq/..-.'. to v.-'; //d!C , and state that to the best of my knowledge and belief, the Owner has perforfied examinations and'taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inarr manner for any personal injury or property damage or a loss of any kind arising from or connected with this insp tio Commissions Inspector's Signagr6 _ National Board, State, Province, and Endorsements Date '/17 2009

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/04/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50W Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 06040073-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50W MECHANICAL FLOWSERVE M&E 30-015098 NA ASME SA479 N/A REPLACED NO SEAL ASP 31037 TP316 MECHANICAL FLOWSERVE M&E 30-015099 NA ASME SA479 N/A REPLACED NO SEAL ASP 31037 TP316 SCREW FLOWSERVE M&E 30-211426 NA ASME SA193 N/A REPLACED NO ASP 31036 GR B6
7. Description of Work REPLACED MECHANICAL SEALS INCUDING GLAND PLATE AND SCREWS
8. Test Conducted: Hydrostatic E- Pneumatic 0 Nominal Operating Pressured Other L.] INSERVICE VT-2 Pressure _psi. Test Temp. __ F IAN 6-7

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 60400073-01

9. Remarks: ESAT 06143089 for missed VT-2. VT-2 will be performed when pump runs again.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report-are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed De av~neýriosg Maintenance Weldina Sunervisor

. . . . i i I Date eA -5 ,20_____

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period ,- *-'(. to 7- ,aV-0.C, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions ,V. 2 1614!3' J*pe-Ctor0s'@igrZture National Board, State, Province, and Endorsements Date X*-2"5e 20 6

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date ,04/15106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CCR-457 Name One Cook Place, Bridqman, MI 49106 JOB ORDER No. R0240871-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: COMPONENT COOLING WATER SYSTEM ISl CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No.. or Replacement Stamped ASP, PO) (Yes or No) 2-CCR-457 CAGE N/A M&E 30-040752 NA ASTM A747 N/A REPLACED NO ASP 6286 " CB-7 STEM N/A M&E 30-041238 NA ASTM A479 N/A REPLACED NO ASP 11451 GR 316 PLUG N/A M&E 30-040999 NA ASTM A582 N/A REPLACED NO ASP 18102 TP 416A
7. Description of Work REPLACED STEM, PLUG AND CAGE.
8. Test Conducted: Hydrostatic Di Pneumatic El Nominal Operating Pressure F1 Other I' . Pressure psi. Test Temp. _ F II /Y211 lNIT~

Page 2 of 2 FORM NIS-2 (Back.k)

Job Order!Fie R0240871-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed 4 Maintenance Welding Supervisor Date ____2 ___ ________, 2O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS .hve, inspected the components described in this Owner's Report during the period to ,7--/t'! and state that to the best of my knowledge and belief, the Owner has'performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspettor nor his employer shall be liable in a anner for any personal injury or property damage or a loss of any kind arising from or connected with this i p Di n Commissions ,"//. -c9,-

Inspector's Signature National Board, State, Province, and Endorsements Date F0,// 0 70

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/14/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50E Name One Cook Place, Bridqman, Ml 49106 JOB ORDER No. 04305061-28 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI 1B31.1 1983 Ed, N/A Add. Code CaseN-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50E FILLER N/A M&E 30-044990 ER308/308L N/A REPLACED NO MATERIAL ASP 29734&

27174 3" ALL THREAD N/A M&E 30-212295 NA ASME SA453 N/A REPLACED NO ASP 23051 GR 660

% HEX NUT N/A M&E 30-046903 NA ASME SA1 94 NIA REPLACED NO ASP 15347 GR8F

7. Description of Work REPLACED FLANGE BOLTING AND REWELDED PIPE
8. Test Conducted: Hydrostatic El Pneumatic Nominal Operating Pressure F-Other F-1 PT, RT, INSERVICE VT-2 Pressure psi. Test Temp. F 7/ lIT~

Page 2 of 2 FORIH NIS-2 (Back)

Job Order/File 04305061-28

9. Remarks: PT, RT, Inservice VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date NIA Signed D4 ayl ogns Z Maintenance Weldinq Supervisor Date 20 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS .hve ins ected the components described in this Owner's Report during the period 2.__,"- to Sb,*f5/t_ " , and state that to the best of my knbwledge and belief, the Owner has peIrformed examinations and-ftaken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and coq ctive measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liav.'ý ir)any manner for any personal injury or property damage or a loss of any kind arising from or connected with this '*.V ton.

(0AI cý77 r IWI a&Zýcq 7(---

National Board, State, 'Pro{,ince, and Enidorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04114106 Name P-O. Box 60 Fort Wavnn. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50E Name One Cook Place. Bridaman. MI 49106 JOB ORDER No. 04305061-27 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date NIA Address
4. Identification of System: EMERGENCY CORE COOLING SYSTEM IS1 CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A " Add. Code CaseN-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code "

(Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50E FILLER N/A M&E 30-045075 ER316/316L N/A REPLACED NO MATERIAL ASP 19713 1 W"ALL N/A M&E 30-212315 NA ASME SA453 N/A REPLACED NO THREAD " ASP 24977 GR 660 1 Y" N/A M&E 30-212142 NA ASME SA194 N/A REPLACED NO HEX NUT ASP 30823 GR 8F

7. Description of Work REPLACED FLANGE BOLTING AND REWELDED PIPE
8. Test Conducted: Hydrostatic l- Pneumatic F-1 Nominal Operating Pressure Other LI PT, RT, INSERVICE VT-2 Pressure psi. Test Temp. F 73

Page 2 of 2 FORM. NIS-2 (Balk)

Job OrderlFile 04305061-27

9. Remarks: PT, RT, Inservice VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed D v on Maintenance Welding Supervisor Date ,20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS 1 / have inspected the components described in this Owner's Report during the period *!99!Oy to 6-/i-/ , and state that to the best of my knowledge and -belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this. Owner's Report Furthermore, neither the Inspector nor his employer shall be liableAJq any manner for any personal injury or property damage or a loss of any kind arising from or conne4,cted with thishn bebtion.

7'-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 0411C /106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SV-104W Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. R0226722-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SV-104W SAFETY VALVE N/A M&E 30-036394 NA ASME SA351 NIA REPLACED NO ASP 29057 GR CF8M 5/8" NUT N/A M&E 30-212089 NA ASME SA194 REPLACED NO ASP 25904 GR8F 5/8" THREADED NIA M&E 30-212290 NA ASME SA453 REPLACED NO ROD ASP 29520 GR 660 5/8" NUT N/A M&E 30-212090 NA ASME SA194 REPLACED NO ASP 30787 GR 8F
7. Description of Work REPLACED VALVE AND BOLTING
8. Test Conducted: Hydrostatic ED Pneumatic j-'- Nominal Operating Pressure -

Other F INSERVICE VT-2, Pressure _ psi. Test Temp. _ F 75-

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File R0226722-01

9. Remarks: Inservice VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N(A Signed I nt~n2nt~ W~ldinri Suo~rvi~or Date . 20 41 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON., TEXAS , , have ipspected the components described in this Owners Report during the period ____-_______ to. ,.17-/A ,and state that to the best of my knowledge and belief, the Owner I's pbrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in azy manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecliorT.

76*

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04120106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GBD-S568 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. R0037674-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. NIA One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: STEAM GENERATOR BLOWDOWN SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-GBD-S568 SNUBBER GRINNELL M&E 30-024682 N/A S/N 33301 N/A Replacement NO ASP 26349 SEAL KIT GRINNELL M&E 30-025055 N/A N/A N/A Replacement NO ASP 23443 "A" SEAL KIT GRINNELL M&E 30-040590 N/A N/A N/A Replacement NO ASP 21030 TAPER PiN GRINNELL M&E 30-024975 N/A GRINNELL N/A Replacement NO ASP 13571 FIG 312
7. Description of Work REPLACED SNUBBER WITH REBUILT
8. Test Conducted: Hydrostatic '-- Pneumatic -] Nominal Operating Pressure-Other Fxý VT-3 Pressure NIA psi. Test Temp. N/A F 77

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File R0037674-01

9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed D nMaintenance Welding Supervisor Date 5 20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS -- have ispected the components described in this Owner's Report during the period ____ /___-__to , and state that to the best of my knowledge and belief, the Owner haE performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins nd Commissions A/6A? 97rY / ~ 7 Inspctors Si~atuNational Board, 8;tate, Province, and Endorsements

. Date V42QC 6-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04103/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-NRV-153 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05121006-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridoman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS I
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-NRV-153 VALVE STEM NIA M&E 30-042247 NA HAYNES N/A REPLACED NO ASP 28948 ALLOY 25 PLUG N/A M&E 30-042070 NA ASTM N/A REPLACED NO ASP 26743 A479/276 T316
7. Description of Work REPLACED STEM AND PLUG
8. Test Conducted: Hydrostatic E' Pneumatic F Nominal Operating Pressure[

Other D1 VT-2 at NOP/NOT Pressure psi. Test Temp. F INIT'~

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 05121006-01

9. Remarks: VT-2 at NOP/NOT Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR& REPLACEMENT conforms to the rules of the ASME Code,Section X). repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed L-&avewy/M 411_1 Mairntenance Weldina Supervisor Date , 200*

Owner or-Owner's Designee, Title I

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS / 4 haveyin pected the components described in this Owners Report during the period -____ _o-to

_ ___________ _ , and state that to the best of my knowledge and belief, the Owner has lperf6rmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or impried, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabl in y manner for any personal injury or property damage or a loss of any kind arising from or connected with this ti n.

I, -. Commissions A[&0177 /g/ 8t~ZgS'z; Inspector's Sig2ature National Board, State, Province, and Endorsements Date LC I 206G __

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI

1. Owner Indiana Michigan Power Date Julv 19. 2006 Name P.O. Box 60, Fort Wayne, IN 46801 Sheet I of 22 Of Address
2. Plant D.C. Cook Nuclear Power Plant Unit 2 Name Berrien Cognt. Bridmman, M1 49106 see Remarks Addre= RepairReplacement Organization P 0 No, Job No, etz
3. Work Performed by AREVA NP Type Code Symbol Stapp NIA Name Authorization No. N/A 33"15 Old Forest Rd, Lynchbuugr VA 24501 Expiration Date NIA Address
4. Identification of System Pressurizer, 2-OME-4. ASME III Class 1. ISI Class I
5. (a) Applicable Construction Code ASME ITL 1998 Edition 2000 Addenda, None Code Case (b) Applicable Edition of Secti6n X) Utilized for Repair/Replacemrnt Activity-.1989 Edition, no Addenda (see Remarks)

(c) Applicable Section XI Code Case(s): N-638-1, N-416-1. N-504-2, N-460, 2142-2 (see Remarics)

6. Identification of Components Repaired or Replaced and Replacement Components.
7. Description of Work: Welded Preemptive Weld Overlays on Dissimilar Metal Welds on Safety, Relief. Spray and Surge Nozzles
8. Tests Conducted: Hydrostatic [] Pneumatic [E Nominal Operating Pressure R Other [] Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawifgs may be used, provided (I) size is 8 1/2x I1 in. (A4)

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

nUrrT

FORM NIS-2 (Back) 0 7=

anrr Tn Appficable Manufarturer's Data Reports to be attached Line 2: AREVA Process Traveler Package Nos. 50-9007637-002, 50-9007639-002, 50-9007641-002 and AEP Job OrderNos. 05237040 17, 18, 22, 23, 27.28, 32, 33, 37, 38 and 43.

TAr~ ~(h~ rnr¶ (~"V SeLettr 1Nos AEP.NR t:555-1 3 AEP1-JRC:6V)5S AIEP.NRC:6055 5aSnd AFEP.NRC:05-A d Alternatives to ASME XI 1989 Edition, no Addenda and applicable ASME Section XI Code Cases CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section X)

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Sirned Kv.'"D*.E ConsultantDa Date ) 0 11, ,20 06 Signed .......... Owner eor, or AR NeD Owner's eine T Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Micnigan and employed by ABS Consulting =nc.

of Houston, Texas have inspected the components described in this Owner's Report during the period November 9. 2004 to mti4ce &AIX 7"/'- o C, and state that to the best of my knowledge and belieý the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMIE Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any persona] injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions" /0M/,' AW/I ipector'i Signature National Board, State, Province, and Endorsements rMate 2QO,"