Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place Bridgman, MI49106 111 ER* J* R AE~corn A unitof American Electric Power August 4, 2006 AEP:NRC:6055-10 10 CFR 50.55a Docket No. 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 2 INSERVICE INSPECTION
SUMMARY
REPORT The attachment to this letter provides a copy of the inservice inspection summary report for activities at Donald C. Cook Nuclear Plant Unit 2, National Board (State of Michigan)
Number 1 (Mich. M-324232-M), located in Bridgman, Michigan. The plant is owned by Indiana Michigan Power Company, P.O. Box 60, Fort Wayne, IN, 46801.
The Unit 2 commercial service date is July 1, 1978, and the Authorized Code Inspectors during the report period were Mr. A. S. Jimenez and Mr. J. A. Longenberger, both of whom were employed by ABS Group, Inc. of Houston, Texas.
The examinations, tests, replacements, repairs performed, conditions observed, and corrective measures taken are summarized in the attached report. Inservice inspection activities were performed in accordance with the rules and requirements of the American Society of Mechanical Engineers' Code,Section XI, 1989 Edition (no Addenda) and 1992 Edition with the 1992 Addenda, as applicable.
There are no new commitments in this letter. Should you have any questions, please contact Ms. Susan D. Simpson, Regulatory Affairs Manager, at (269) 466-2428.
Sin~cerqqly, JoseeSupport Jensen Services Vice President
Attachment:
Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2, 2006, Unit 2 Cycle 16 Refueling Outage.
RV/rdw AOL,7
U. S. Nuclear Regulatory Commission AEP:NRC:6055-10 Page 2 c: R. Aben, DLEG/BCCFS/BD J. L. Caldwell, NRC Region III K. D. Curry, Ft. Wayne AEP, w/o attachment J. T. King, MPSC, w/o attachment MDEQ - WHMD/RPMWS, w/o attachment NRC Resident Inspector P. S. Tam, NRC Washington, DC
Attachment to AEP:NRC:6055-10 Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 2 2006, Unit 2 Cycle 16 Refueling Outage
INSERVICE INSPECTION
SUMMARY
REPORT FOR THE DONALD C. COOK NUCLEAR PLANT UNIT 2 2006, Unit 2 Cycle 16 REFUELING OUTAGE INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report for Inspection Period From November 10, 2004 to May 5, 2006 Prepared by: "4 ý eDat I ogram Owner LL12ijjl o
Reviewed by: Date:
Engineering Programs Supervisor 1 of 82 Total Pages
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 Report of Inservice Inspections From November 10, 2004 to May 5, 2006 TABLE OF CONTENTS Pages Section 1 Introduction 3 Section 2 NIS-1 Inservice Inspection 4-6 Summary Report Section 3 Abstract of Examinations, Results,. 7-16 And Corrective Actions for Class 1 And Class 2 Components Section 4 System Pressure Tests 17 Section 5 Snubber Tests 18-20 Section 6 ASME Section XI, Article IWE and IWL 21-26 Section 7 ASME Section XI, Steam Generator 27 Eddy Current Examinations Section 8 NIS-2 Repair and Replacement 28-29 Reports Index Section 9 NIS-2 Repair and Replacement 30-82 Reports 2
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2, BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 1 INTRODUCTION This report summarizes the Inservice Inspection (ISI) activities performed at the Donald C. Cook Nuclear Plant (CNP) Unit 2, for the period of November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Unit 2 Cycle 16, 2006, Refueling Outage. This is the second and final refueling outage of the Second Inspection Period of the Third Ten-Year Interval.
These activities were performed in accordancb with the requirements of the ASME Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. As of July 1, 1996, the third ten-year inspection interval began and the applicable code of record for ISI activities became ASME Section XI, 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda for the Containment as applicable.
The purpose of this report is to satisfy the requirements of IWA-6000 for the submittal of an Inservice Inspection Summary Report at the completion of each refueling outage.
Examination and tests conducted since the preceding summary report are included in this report. Repairs and replacements are also included in this report per the requirements of the 1989 Edition of ASME Section XI, IWA-6220.
Contents of this report have been reviewed and verified correct with supporting documentation available at the plant for review if required.
3
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 2 NIS-1 INSERVICE INSPECTION
SUMMARY
REPORT Acronyms CCW Component Cooling Water System CS Emergency Core Cooling System CTS Containment Spray System ESW Essential Service Water System' FW Feedwater System MDAFP Motor Driven Auxiliary Feedwater Pump MS Main Steam System NOP Normal Operating Pressure NOT Normal Operating Temperature RCP Reactor Coolant Pump RCS Reactor Coolant System RHR Residual Heat Removal Syktem RWST Refueling Water Storage Tank SI Safety Injection System TDAFP Turbine Driven Auxiliary Feedwater Pump 4
FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Brid*gman, MI 49106 (Name and Address of Plant)
- 3. Plant Unit: Two
- 4. Owner Certification of Authorization (if required): N/A
- 5. Commercial Service Date: 07/01/78
- 6. National Board Number for Unit: 1 (Mich. M-324232-M?)
- 7. Components Inspected Component or Manufacturer or Manufacturer or State or Province National Board Appurtenance Installer Installer Serial Number Number Number Reactor Pressure Chicago Bridge T-1 M-324232-M I Vessel and Iron Steam Generator, Westinghouse/MK 1341- Upper, M-324-234-M 68 Upper 2-OME-3-1 -Ferguson Assembly 37 - Lower 3367G - Lower Assembly East RHR Heat Westinghouse/MK 1344 - Upper M-324-237-M 68 Upper Exchanger -Ferguson Assembly 38 - Lower 2-HE-17E 3368G - Lower Assembly Pressurizer Westinghouse 1231 M-324233-M 6894 2-OME-4 West CTS Heat Yuba 69-G-226-ID N/A N/A Exchanger 2-HE-18W West RHR Heat Engineers and S-15586-C N/A N/A Exchanger Fabricators, INC 2-HE-17W Containment Graver N/A N/A N/A Piping Systems - Power Systems N/A N/A N/A RCS, RHR, SI, Inc. and TUBECO CTS, CCW, CS, ESW, FW, MS Pipe Supports Grinnell 5
- 8. Examination Dates: November 10, 2004 to May 5. 2006
- 9. Inspection Period Identification: Second
- 10. Inspection Interval Identification: Third
- 11. Applicable Edition of Section XI 1989 no Addenda & 1992 with 1992 Addenda
- 12. Date/Revision of Inspection Plan: 8/03 Rev. I
- 13. Abstract of Examinations. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
See Sections 3, 4, 5, 6, and 7
- 14. Abstract of Results of Examinations and Tests.
See Sections 3, 4, 5, 6 and 7
- 15. Abstract of Corrective Measures.
See Sections 3, 4, 5, 6, and 7 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code; -Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section X).
Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date .'D' _, 4 20 No Signed Indiana Michigan Power Co. By Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of,.e,- tt,,) K and employed by An_? CJ.P.. /IAIz of Agljh.&jny ,r.4" have inspected the components described in this Owner's Report during the period,,,.,,i, /v ,to LIE41e. .,0. , and state that to the best of my knowledge and belief, the Owner has performed examiniiations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.
Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
SCommissions Vz- cj/
Inspector s Signature National Board, State, Province, and Endorsements D ate 20oe.
6
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 3 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR CLASS 1 AND CLASS 2 COMPONENTS Inservice examinations were performed during the period November 10, 2004, to May 5, 2006. This report addresses examinations and activities associated with the Third 10-Year Interval, Second Inspection Period, -Second Refueling Outage (Unit 2 Cycle 16). All examinations were in accordance with the 1989 Edition (no Addenda) and 1992 Edition with 1992 Addenda as applicable.
Examinations were scheduled and performed according to the Third Ten-Year Long Term Inservice Examination Plan for Class 1, 2, and 3 Systems and Components for CNP, Unit 2. This is the currently approved ISI examination plan that identifies specific activities to be performed on a refueling outage basis.
Twenty-six (26) ASME Class 1 and twenty-eight (28) ASME Class 2 components were examined. A combination of Ultrasonic, Magnetic Particle, Liquid Penetrant and Visual examination methods were used. Two supports failed the VT-3 examination. Support 2-ACS-R-913 had a loose nut on an embedment plate that was evaluated as an original construction defect and not inservice induced and documented via Work Request 06016013. Support 2-AFW-C-4034 also had a loose nut on a-pipe clamp. This condition was evaluated by Design Engineering (Condition Report 06102054) and Engineering Programs and found acceptable. The cause was attributed to original construction. The supports upstream, downstream and in the immediate vicinity of these two supports were examined and found acceptable. No sample expansions were required.
To proactively address issues with Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 82/182 weld locations in the Unit 2 pressurizer safe ends, all the safe ends on the Unit 2 pressurizer received Pre-emptive Weld Overlays (PWOL) to mitigate the potential for PWSCC. Each location received a fully qualified ASME Section XI Appendix VIII, Supplement 11 ultrasonic examination and a surface examination over 100% of the required weld volume. No evidence of PWSCC or other rejectable indications were observed.
During the Unit 2, Cycle 16 refueling outage, Indiana Michigan Power Company (I&M),
the licensee for CNP Unit 2, performed a bare-metal visual inspection of the CNP Unit 2 reactor pressure vessel (RPV) bottom-mounted instrumentation (BMI) nozzle penetrations, and bare-metal and volumetric examinations of the RPV upper head in response to NRC Revised Order EA-03-009, "Issuance of Order Establishing Interim 7
Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors".
The BMI inspection was conducted by contractor and I&M personnel, and included personnel qualified as American Society of Mechanical Engineers Code,Section XI, Level II examiners. The bottom two sections of insulation were lowered to allow unobstructed access to all penetrations and the membrane areas of the lower reactor vessel. A pole-mounted camera was used to perform a VT-2 examination to VT-3 examination criteria for distance and lighting on all 58 Unit2 RPV BMI nozzle penetrations, including 360 degrees around each BMI penetration. No boric acid deposits were found at any RPV BMI nozzle penetration or anywhere on the RPV bottom-head surface area. No boric acid residue sampling or analysis was required or performed. The as-found condition of the Unit 2 RPV bottom head was identical to the as-left condition following the bottom cleaning and re-inspection performed during the Unit 2, Cycle 15 refueling outage. No indications of through-wall leakage were found during the Unit 2, Cycle 16 RPV BMI inspection. The inspection results were digitally recorded, and copies of the video files were saved to computer drives as video clips.
A 100% bare-metal visual examination of the Unit 2 RPV upper head showed no evidence of pressure boundary leakage. However, evidence of above-head leakage from an external source was discovered near Penetration Number 42. To ensure that the source of residue was not the result of pressure-boundary leakage, the following were performed.
- A chemical sample analysis, which determined the residue to be 1.3 to 1.6 years old, was performed.
- Extensive visual examinations of Penetration 42 (prior to and after residue sampling and cleaning) were performed. The examination indicated that the origin of the residue was not from the annular gap between the vessel head and the penetration tube. Evidence of previous above-head leakage, including pooling and dripping, was observed on the insulation panel seam in the vicinity above Penetration 42.
0 A volumetric examination, including ultrasonic/eddy current of the inside diameter of the penetration tube, was performed. No rejectable indications were found and no evidence of leakage in the shrink-fit region was observed in the J-groove weld inspection data.
& Supplemental eddy current examinations of the J-groove weld and penetration tube outside diameter surfaces were conducted. No rejectable indications were observed in the J-groove weld inspection data.
- A manual surface examination using liquid penetrant was performed on the Penetration 42 nozzle immediately above the reactor vessel closure head. No indications were observed.
A 100 % volumetric examination of the 78 control rod drive mechanism penetrations and the single vent penetration in the Unit 2 RPV head was completed in accordance with Section IV.C(5)(b)(iii) utilizing an approved relaxation of the requirements obtained in 8
accordance with Section JV.F. No unacceptable indications were found. No repairs of any head penetrations were needed or performed.
System pressure tests did not reveal any degradation of the system pressure boundary or the installed bolting.
The following Code Cases were utilized during this reporting period:
N-416-1 N-460 N-504-2 N-509 N-533 N-616 N-638-1 N-627 N-491 -1 Nondestructive examinations were performed by WesDyne, AREVA/Framatome and I&M personnel in accordance with procedures approved for use at CNP.
9
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
- 6. National Board Number for Unit: 1 (Mich. M-
- 3. Plant Unit: TWO 324232-M)
Summary Component No. Component ID Description Item Procedure . Method/Reoort/Results Class I Category B-B 006500 2-PRZ-15 UPPER HEAD TO UPPER B2.11 54-IS1-130 UT UT-06-027 Accept SHELL 54-IS1-130 IUTUT-06-028 Accept 54-IS1-130 UT UT-06-031 Accept 54-ISI-130 UT UT-06-032 Accept 006900 2-PRZ-19 LONGITUDINAL SEAM B2.12 54-ISI-130 UT UT-06-029 Accept 54-IS1-130 UT UT-06-026 Accept 54-ISI-130 UT UT-06-025 Accept 54-ISI-130 UT UT-06-030 Accept 54-ISI-130 UT UT-06-024 Accept 54-ISI-130 IUTUT-06-023 Accept 008600 STM-21-01 LOWER HEAD TO TUBE B2.40 54-1S1-130 UT UT-06-013 Info SHEET 54-IS1-130 UT UT-06-016 Accept 54-ISI-130 UT UT-06-015 Accept 54-ISI-130 UT UT-06-014 Accept 54-ISI-130 UT UT-06-017 Accept Class 1 Category B-G-1 004700 2-RPV-FLANGE THREADS 1 THROUGH 54 86.40 54-1S1-108 UT UT-06-004 Accept 10
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
- 6. National Board Number for Unit: I (Mich. M-
- 3. Plant Unit: TWO 324232.M)
Summary Component No. Component ID Description Item Procedure Method/Report/Results Class I Category B-G-2 030400 2-RC-26-09-FB FLANGE BOLTING B7.50 12-QHP-5050- VT VT-06-021 Accept NDE-006 049000 2-RC-32-13-FB FLANGE BOLTING B7.50 12-QHP-5050-, VT VT-06-038 Accept NDE-006 053100 2-RC-33-18-FB FLANGE BOLTING B7.50 12-QHP-5050- VT V17-06-041 Accept NDE-006 071600 2-RC-515-21-FB FLANGE BOLTING B7.50 12-QHP-5050-, VT VT-06-039 Accept NDE-006 078600 2-RC-517-23-FB FLANGE BOLTING B7.50 12-QHP-5050- VT VT-06-037 Accept NDE-006 153075 PUMP BOLTS (12 - 2" BOLTS)
........... * .. . ..... I LOWER SEAL HOUS ING B7.50 12-QHP-5050- VT VT-06-036 Accept BOLTS NDE-006 220200 SV-45A BODY TO BONNET B7.70 12-QHP-5050- VT VT-06-018B Accept NDE-006 220700 SI-170-L2 BODY TO BONNET B7.70 12-QHP-5050- VT VT-06-029 Accept BOLTING NDE-006 221550 IMO-325 FLANGE BOLTING B7.70 12-QHP-5050- VT VT-06-033 Accept NDE-006 222400 IMO-128 FLANGE BOLTING B7.70 12-QHP-5050- VT VT-06-028 Accept NDE-006 Class I Category B-J 088100 2-SI-56-03 ELBOW TO PIPE B9.11 54-ISI-836 UT UT-06-011 Accept 11
Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, 4. Owner Certificate of Authorization (If Req.): NIA Bridgman, MI 49106
- 5. Commercial Service Date: 0710111978
- 3. Plant Unit: TWO 6. National Board Number for Unit: I (Mich. M-324232-M)
Summary Component No. Component ID Description Item Procedure Method/Report/Results =L ....
54-ISI-836 UT UT-06-012 Accept 089750 2-SI-56-1 9 TEE TO PiPE 89.11 54-1SI-836 UT UT-06-019 Accept 54-ISI-836 UT UT-06-018 Accept 54-1SI-836 UT UT-06-020 Accept 092700 2-SI-57-17 PIPE TO ELBOW B9.11 54*ISI-836 UT UT-06-022 Accept 54-ISI-836 UT UT-06-021 Accept 151900 2-WD-822-03 ELBOW TO PIPE 89.40 54-ISI-836 UT UT-06-038 Accept 54-ISI-836 UT UT-06-037 Accept Class 1 Category B-K-1 094800 2-SI-58-03-PL I AND 2 PIPE LUG 810.10 12-QHP-5050- PT PT-06-003 Accept NDE-001 Class I Category B-N-1 006010 RPV UPPER INTERNALS & AREAS ACCESSIBLE 813.10 54-ISI-364 VT VE-06-001 Accept SURFACES DURING NORMAL REFUELING Class 1 Category F-A 600700 2-GRC-R-524 PIPE SUPPORT F1.10 12-QHP-5050- VT VT-06-035 Accept COMPONENT WA NDE-006 12
Attachment 1 Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
- 6. National Board Number for Unit: I (Mich. M-
- 3. Plant Unit: TWO 324232-M)
Summary Component No. Component ID Description Item Procedure Method/Report/Results 601200 2-ARC-R-522B PIPE SUPPORT F1.101 12-QHP-5050- VT VT-06-020 Accept COMPONENT NDE-006 604400 2-GRC-R-565 PIPE SUPPORT FI.10A 12-QHP-5050- VT VT-06-042 Accept COMPONENT NDE-006 607330 2-ASI-R-5301 PIPE SUPPORT F1.10A 12-QHP-5050- VT Vr-06-032 Accept COMPONENT NDE-006 607800 2-GSI-R-698 PIPE SUPPORT Fl.10A 12-QHP-5050- VT VT-06-031 Accept COMPONENT NDE-006 609220 2-GCS-R-543 PIPE SUPPORT F1.10 12-QHP-5050- VT VT-06-027 Accept COMPONENT WB NDE-006 Class 2 Category C-B 300070 STM-21-FWN NOZZLE TO SHELL C2.21 54-ISI-130 UT UT-06-033 Accept 54-ISI-130 UT UT-06-034 Accept 54-151-130 UT UT-06-035 Accept 300090 STM-21-FWN-IRS C2.22 54-ISI-132 UT UT-06-036 Accept 300700 E-RHRHEX-IN NOZZLE TO SHELL C2.21 54-ISI-136 UT UT-06-005 Info 54-ISI-240 PT PT-06-002 Accept 54-ISI-136 IUTUT-06-006 Accept 54-IS1-136 UT UT-06-007 Info 13
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, Mi 49106 5. Commercial Service Date: 0710111978
- 6. National Board Number for Unit: I (Mich. M-
- 3. Plant Unit: TWO 324232-M)
Summary Component No. Comoonent ID Description Item Procedure Method/RenootResults 300871 2-ILA-110-Vl Ile Procedure Method/Rer)ort/Results INSTRUMENT NOZZLE TO C2.21 54-ISI-836 UT UT-06-009 Accept SHELL 300873 2-ILA-111-Vl INSTRUMENT NOZZLE TO C2.21 54-ISI-836 UT UT-06-010 Accept SHELL 300874 2-ILA-11 l-V2 INSTRUMENT NOZZLE TO C2.21 54-ISI-836 UT UT-06-008 Accept SHELL Class 2 Category C-C 310915 2-SI-9-05S-PS 1 THRU 4 4 PIPE LUG C3.20 12-QHP-5050- PT PT-06-001 Accept NDE-001 319170 2-FW-74-OIF PENETRATION SUPPORT C3.20 12-QHP-5050- PT PT-06-004 Accept WELD NDE-001 323060 MSIV-MRV-230-S1 C3.40 12-QHP-5050- MT MT-06-001 Accept NDE-002 323070 MSIV-MRV-230-S2 C3.40 12-QHP-5050- MT MT-06-002 Accept NDE-002 Class 2 Category C-G 322950 MSIV-MRV-210-1 CYLINDER WELD C6.20 12-QHP-5050- MT MT-06-003 Accept NDE-002 Class 2 Category F-A 700010 CS-1 BRACKET F1.40 12-QHP-5050- VT VT-06-014 Accept NDE-006 700020 CS-2 BRACKET F1.40 12-QHP-5050- VT V17-06-015 Accept NDE-006 14
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801 4. Owner Certificate of Authorization (If Req.): NIA
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
- 6. National Board Number for Unit: I (Mich. M-
- 3. Plant Unit: TWO 324232-M)
Summary Component No. Component ID Description Item Procedure Method/Report/Results 700040 CS-4 BRACKET F1.40 12-QHP-5050- VT VT-06-017 Accept NDE-006 713097 2-ARH-R-5011 F-A F1l.20ACOMPONENT F1.20A 12-QHP-5050- VT Vr-06-03Q Accept NDE-006 713285 2-GRH-V-9 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-034 Accept COMPONENT WC NDE-006 713870 2-GCTS-L-43 PIPE SUPPORT Fl.20B 12-QHP-5050-. VT VT-06-022 Accept COMPONENT NDE-006 713940 2-GCTS-R-46 PIPE SUPPORT F1.20B 12-QHP-5050- VT V17-06-024 Accept COMPONENT NDE-006 714120 2-GCTS-V-54 PIPE SUPPORT F1.20C 12-QHP-5050- VT V17-06-040 Accept COMPONENT NDE-006 716065 2-GCTS-R-17 PIPE SUPPORT F1.20A 12-QHP-5050- VT VT-06-005 Accept COMPONENT NDE-006 716240 2-GCTS-R-8 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-006 Accept COMPONENT WB NDE-006 751600 2-GFW-V-881 - PIPE RESTRAINT F1.20C 12-QHP-5050- VT VT-06-01 9 Accept COMPONENT NDE-006 754600 2-AFW-C-4034 PIPE SUPPORT F1.20C 12-QHP-5050- VT VT-06-043 Reject COMPONENT NDE-006 Evaluation Disposition Acceptable per DES evaluation contained in CRE 06102054.
Acceptable:
15
Attachment I Inservice Inspection Report Interval 3, Period 2, U2-C16
Wayne, IN 46801 4. Owner Certificate of Authorization (if Req.): NIA
- 2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, MI 49106 5. Commercial Service Date: 0710111978
- 6. National Board Number for Unit: 1 (Mich. M-
- 3. Plant Unit: TWO 324232-M)
Summary Component No. Component ID Description Item Procedure Method/Report/Results 763240 2-GSI-L-30 PIPE SUPPORT F1.20A 12-QHP-5050- VT VT-06-023 Accept COMPONENT NDE-006 763710 2-GSI-R-822 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-026 Accept COMPONENT WA NDE-006 763740 2-GSI-L-826 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-025 Accept COMPONENT WA NDE-006 764210 2-ACS-R-1 15 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06-009 Accept COMPONENT WB NDE-006 764380 2-GCS-L-123 PIPE SUPPORT F1.20 12-QHP-5050- VT VT-06.007 Accept COMPONENT WA NDE-006 764940 2-ACS-R-913 PIPE SUPPORT F17.20B 12-QHP-5050- VT VT-06-008 Reject COMPONENT NDE-006 16
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 4 ABSTRACT OF SYSTEM PRESSURE TESTS RESULTS Inservice Inspection System Pressure Tests were performed during the period November 10, 2004, to May 5, 2006. These tests were performed in accordance with the requirements of ASME Section XI, 1989 (no Addenda) and 1992 Editions with 1992 Addenda, Articles IWA-5000, IWB-5000, IWC-5000, IWD-5000, Code Case N-416-1, Code Case N-533 and N-616, as applicable.
Pressure tests for portions of systems identified below were performed during this outage.
The remainder of the pressure tests for the period will be performed in conjunction with functional tests, inservice operation, and special procedures as applicable. No pressure boundary through-wall leaks were identified.
Job Completion Order Activity Test Description Date R0227736 2 North SI pump and associated piping 5/6/2006 R0227736 4 South SI pump and associated piping 5/612006 R0227736 6 Accumulators and associated piping 4/17/2006 R0227736 8 Bit tank and associated piping 3/25/2006 R0227736 9 South seal water injection filter 3124/2006 R0227736 10 North seal water injection filter 4/17/2006 R0227736 11 East Charging Pump and associated piping 3/24/2006 R0227736 12 West Charging Pump and associated piping 4/19/2006 R0227736 13 East CTS Pump and Associated Piping 4/11/2006 R0227736 14 West CTS Pump and Associated Piping 5/5/2006 R0227736 15 Spray Additive tank and associated piping 3/24/2006 R0227736 16 Seal water leak off piping at RCPs 5/6/2006 R0227736 17 Seal water filter, heat exchanger, and associated piping 3/25/2006 R0227736 18 TDAFP Motor Operated Valves to Check Valves 4/30/2006 R0227736 19 Letdown heat exchanger and associated piping 5/5/2006 R0227736 23 TDAFP and associated piping 5/5/2006 R0227736 24 East MDAFP and associated piping 5/5/2006 R0227736 25 West MDAFP and associated piping 8/26/2005 R0266778 1 RCS NOP/NOT 8/24/2005 R0233818 2 ESW Pumps and associated piping 5/6/2006 R0243844 1 Condensate Storage Tank and Associated Piping 5/6/2006 R0243844 2 RWST and associated piping 4/17/2006 R0243844 3 South Spent Fuel Pool Pumps and Associated Piping 3/25/2006 R0243844 4 North Spent Fuel Pool Pumps and Associated Piping 3/24/2006 R0243844 5 South Boric Acid Storage Tank and Associated Piping 4/17/2006 R0243844 6 Volume Control Tank and Associated Piping 3124/2006 17
INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.
UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 SECTION 5 ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS Snubber examinations and functional testing were performed in conjunction with the maintenance procedures implemented to satisfy technical specification surveillance requirements. Provided is a summary of the as-found visual examinations and as-found functional test results.
Snubber VT-3 Visual Examinations Snubber No. Exam Date Job Order No. Results 2-GRC-$537 04-04-06 R0266439 Acceptable 2-GRC-S538 04-18-06 R0266439 Acceptable 2-GRC-$555 04-18-06 R0266439 Acceptable 2-GRC-$562 04-04-06 R0266439 Acceptable 2-GRC-$564 04-18-06 R0266439 Acceptable 2-GRC-$566 04-04-06 R0266439 Acceptable 2-GRC-$573 04-18-06 R0266439 Acceptable 2-GRC-S575 04-04-06 R0266439 Acceptable 2-GRC-S582 04-18-06 R0266439 Acceptable 2-GRC-S592 04-04-06 R0266439 Acceptable 2-GRC-S594 04-04-06 R0266439 Acceptable 2-GRC-S596 04-04-06 R0266439 Acceptable 2-GRC-S598 04-04-06 R0266439 Acceptable 2-GRC-S599 04-18-06 R0266439 Acceptable 2-GRC-S609 04-04-06 R0266439 Acceptable 2-GRC-S611 04-04-06 R0266439 Acceptable 2-GRC-S623 04-04-06 R0266439 Acceptable 2-GRC-S624 04-18-06 R0266439 Acceptable 2-GRC-S626 04-04-06 R0266439 Acceptable 2-GRC-S629 04-04-06 R0266439 Acceptable 2-GRC-S630 04-04-06 R0266439 Acceptable 2-GRC-S632 04-04-06 R0266439 Acceptable 2-GRC-S631 04-04-06 R0266439 Acceptable 2-GRC-S587 04-04-06 R0266439 Acceptable 2-AFW-S4023 04-13-06 R0266100 Acceptable 2-AFW-S4024(L) 04-13-06 R0266100 Acceptable 2-AFW-S4024(U) 04-13-06 R0266100 Acceptable 2-AFW-S4021 04-13-06 R0266100 Acceptable 2-AFW-S4028(L) 04-13-06 R0266100 Acceptable 2-AFW-S4028(U) 04-13-06 R0266100 I Acceptable 18
INDIANA MICHIGAN POWER COMPANY COOK NUCLEAR PLANT, BRIDGMAN, MI.
UNIT 2 COMMERCIAL SERVICE DATE 7-1-1978 Snubber VT-3 Visual Examinations (Continued)
Snubber No. Exam Date Job Order No. Results 2-AFW-S4027 04-13-06 R0266100 Acceptable 2-AFW-S4025 04-13-06 R0266100 Acceptable 2-AFW-S4031 04-13-06 R0266100 Acceptable 2-AFW-S4032(L) 04-13-06 R0266100 Acceptable 2-AFW-S40.32(L_ 04-13-06 R0266100 Acceptable 2-AFW-S4029 04-13-06 R0266100 Acceptable 2-AFW-S4036(L) 04-13-06 R0266100 Acceptable 2-AFW-S4036(U) 04-13-06" R0266100 Acceptable 2-AFW-S4035 04-13-06 R0266100 Acceptable 2-AFW-S4033 04-13-06 R0266100 Acceptable 2-GBD-S563(L) 04-12-06 R0266147 Acceptable 2-GBD-S563(U) 04-12-06 R0266147 Acceptable 2-GBD-S569(L 04-12-06 R0266147 Acceptable 2-GBD-S569(U) 04-12-06 R0266147 Acceptable 2-GBD-5S68 04-12-06 R0266147 Acceptable 2-GCCW-S840 02-28-06 R0263765 Acceptable 2-GCCW-S843 02-28-06 R0263765 Acceptable 2-OME-3-1-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-1-HSD-IL 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-3L 04-03-06 R0265677 Acceptable 2-OvE-3-2-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-2-HSD-IL 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-3-HSD-1L 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-3U 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-3L 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD-1U 04-03-06 R0265677 Acceptable 2-OME-3-4-HSD- 1L 04-03-06 R0265677 Acceptable 19
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI.
COMMERCIAL SERVICE DATE 7-1-1978 Snubber Functional Tests Snubber No. Test Date Job Order No. Results Remarks 2-GRC-S538 04-18-06 R0098999 Accept. Small Bore Grinnell 2-GRC-S555 04-19-06 R0099679 Accept. Small Bore Grinnell 2-GRC-S573 04-20-06 R0036212 Accept. Small Bore Grinnell 2-GRC-S611 04-19-06 R0036210 Accept. Small Bore Grinnell 2-GBD-S568 04-20-06 R0037674 Accept. Small Bore Grinnell 2-GCCW-S843 04-17-06 R0037685 Accept. Small Bore Grinnell 2-AFW-S4032-U 04-20-06 R0036689 Accept. Small Bore Grinnell 2-OME-3-4-HSD-IL 04-08-06 R0078801 Accept. Large Bore 2-OME-3-4-HSD-1U 04-07-06 R0100166 Accept. Large Bore 2-OME-3-4-HSD-3L 04-09-06 R0037382 Accept. Large Bore 2-OME-3-4-HSD-3U 04-08-06 R0058565 Accept. Large Bore The minimum 14% required sample size consists of 7 small bore (Grinnell) and 3 large bore (Steam Generator) snubbers.
20
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 6 ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR ASME SECTION XI, SUBSECTIONS IWE AND IWL Containment Inservice Inspections During the reporting period of November 10, 2004, to May 4, 2006, inservice inspections were performed on the Unit 2 Containment pressure retaining structure in accordance with Subsections IWE and IWL of ASME Section XI, 1992 Edition and 1992 Addenda, and 10 CFR 50.55a.
The following attachment provides a listing of the examinations performed, results, and corrective actions, if any were performed. A General Visual Examination was performed on all accessible surfaces of the Containment liner along with examinations performed in conjunction with coating repairs, and other repair/replacement activities.
An acceptance criteria providing the acceptable minimum thickness of the containment liner was established for the examination of the concrete-backed liner. The examination results were compared to the acceptance criteria. All results were within the established acceptance criteria. No areas required to be classified as an Augmented Examination area in accordance with IWE-1240.
Containment concrete examinations are currently in progress as of this report date. No degradation has been found that impacts the structural integrity of the containment concrete. As of this report date, there have been no conditions noted in accessible areas that could indicate the presence or result in degradation to inaccessible areas.
21
Program Owner: (14,,. 2A, NIS-1 Attachment 7 Evaluation of IWE As-Found Condition Examination Results Date: _'-0--o0:,
3125/2006 2 KuzLUI_ ,cones /- -1u/*,(paaZ-b14-lIA, z-1 Z-1 ZA (uenerai None 03 (partial) Visual _______________
Accept 3/25/2006 2 R0246391- Moisture Barrier 2-598-MB (RCDT Area) VT-3 3/25/200612 02 02 ______________ None Accept General' None Accept 3252006 2 R0246391- Zones 2-598-26, 2-598-27 (partial) Visual NoneAccept R0266500al 3/2612006 2 R0266500- Penetration Bolting 2-CPN-80-BOLTING VT-1 None 49 Accept 3126/2006 2 R0266500- Penetration Bolting 2-CPN-57-BOLTING VT-1
_________48 None Accept Prior to coating repair: Liner and penetrations between fence at RCDT to Col. 21 and from 3/28/2006 05132069- floor up approx. 3' and penetrations up to the 01 2nd weld channel (areas of damaged paint). VT-3 None Accept Areas between Cols. 21 and 23 and from the floor up to the 2nd weld channel including penetrations (areas of damaged paint)..
05132069- Prior to coating repair: Zone 2-598-27 (partial) Four small areas, approx. 112" 3/30/2006 2 07 from gate at Col. 27 to concrete, floor elevation VT-3 diameter with chipped top coat. Accept up approx. 9'-0". No base metal wastage.
3/30/2006 2 R0246391- Moisture Barrier 2-598-MB (Annulus area) VT-3 None 1 04 1- . I Accept I I
References:
- 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 22
Program Owner:_ q&. a A ." NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date: 7-Jo-Oh r-lI L.u IU UA:LIII*
191 U dII LUIU
-0u. 4-0 14-4-, r-L. OVU down to EL. 642', 10'-0" east of divider barrier seal. Zone 2-612-25B EL. 642' down to EL.
627', 12'-0" east of divider barrier seal. Zone 2-612-25A EL. 627' down to EL. 612', 12'-0" 05132069- divider barrier seal to Column 26. Zone 2-612- Peeling paint, delamination of 3/31/2006 2 26A EL. 612' up to approx. EL. 622' from 05 VT-3 top coat, discoloration. No liner Accept Column 26 to 27. Zone 2-612-27A EL. 612' up plate degradation noted.
to approx. EL. 622' from column 27 to divider barrier seal. Zone 2-612-1 EL. 612' up to EL.
637' from divider barrier seal to Column 1. Zone 2-612-28A. Zone 2-612-28B EL. 627' to EL.
637'. I I
I I
I I
References:
1)NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 23
Program Owner: NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_ 7 4- ,
/-ones,-598-6, 2-598-7, 2-598-8, 2-598-9, Z-598-5, 2-598-6, 2-598-7, 2-598-8, 2-598-9, 2-598-10, 2-598-11, 2-598-12, 2-598-13, 2-598-14, 2-598-15, 2-598-16, 2-598-17, 2-598-18, 2-598-19, 2-598-20, 2-598-21, 2-598-22, 2-598-23, 2-598-24, 2-598-25, 2-598-27 (partial), 2-612-2, 2-612-3, 2-612-4, 2-612-5, 2-612-6, 2-612-7, 2-612-8, 2-612-9, 2-612-101B, 2-612-11 B, 2-612-12A, 2-612-122B, 2-612-13A, 2-612-13B, Discoloration noted. No evidence R0246391- 2-612-14A, 2-612-14B, 2-612-15A, 2-612-15B, 3131/2006 2 04 2-612-16, 2-612-17, 2-612-18, 2-612-19, 2-612- General of degradation that may affect Accept 20, 2-612-21, 2-612-22,2-612-23, 2-612-24, 2- Visual either containment structural 612-25A, 2-612-25B, 2-612-25C, 2-612-26A, 2- integrity or leak tightness.
612-26B, 2-612-26C, 2-612-27A, 2-612-27B, 2-612-27C, 2-612-28A, 2-612-28B, 2-612-1, 2-650-1A, 2-650-11B, 2-650-1C, 2-650-2A, 2-650-2B, 2-6.50-2C, 2-650-3A, 2-650-3B, 2-650-3C, 2-650-4, 2-715-IA, 2-715-1B, 2-715-IC, 2-715-2A, 2-715-2B, 2-715-3, 2-745-001, 2-757-001, Inspection Ports: 2-PORT-01, 2-PORT-02, 2-PORT-03 4(5/2006 05132069- Prior 627'totopaint removal: Instrument 03 ceiling and Azimuth 262 toRoom EL.
divider VT-3 Slight flaking and discoloration.
No liner degradation noted. Accept barrier seal.
Prior to coatings removal: Containment Penetration 2-CPN-4 at first weld towards 4/512006 2 R0257113- containment from the #1 cooler to the radius VT-3 Slight discoloration. Accept 02 transition at the pipe end. Area of inspection edge of the toe of the welds described above.
References:
1)NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 24
ProgramO NIS-1 Attachment Evaluation of IWE As-Found Condition Examination Results Date:_7-C20...-c4, 05132069- Peeling paint, delamination, light 4M7/2006 2 Prior to surface prep: Zones 2-612-20, 2-612-21 VT-3 discoloration, surface rust. No 02 Accept evidence of liner degradation.
Liner surfaces behind divider barrier seal when seal segment is removed: Zone 2-612-2 Seal sample #1, between Columns 2 - 3, area approx. 3'-0" wide, 5'-0" high, starting approx. 8" No evidence of degradation that R0265946- up from seal. Existing gap of <114" wide with General may affect either containment 418/2006 2 06 internal obstructions prevent view of attachment Visual structural integrity or leak weld. Zone 2-612-24 Seal sample #2, area Accept tightness noted on viewable approx. 2'-0" wide, 2'-0" high, starting at surfaces.
attachment weld. Existing gap of approx. 1/4" wide at one location with internal obstructions prevent view of surfaces Prior to paint removal: Zone 2-650-1A Liner Light discoloration. No liner plate 4113/2006 2 05341030- plate surfaces surrounding the following Vr-3 03 penetrations, and penetration surfaces: 2-CPN- or penetration surface degradation Accept or wastage noted.
56, 57, 65, 80, 83, 86... degradation or wastage noted Prior to coatings removal: Containment Penetration 2-CPN-2 at first weld towards 4/15/2006 2 R0257111- containment frompipe the end.
- 1 cooler to inspection the radius 02 transition at the Area of VT-3 Discoloration and flaking. No pisotration adakin no Accept 360 deg. Around penetration and 1/2" from the edge of the toe of the weld and transition described above.I
References:
- 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-5360, Rev. 0" 25
Program Owner:a NIS-1 Attachment Evaluation of WE As-Found Condition Examination Results Date:_7--o-- ,
rIuIi.v L '+luriys iwerijlvdii LjUILaIrlII*IrIL Penetration 2-CPN-5 at first weld towards 4(15(2006 R0257114- containment from the #1 cooler to the radius 2 Slight discoloration. No 02 transition at the pipe end. Area of inspection VT-3 Accept penetration degradation noted.
360 deg. Around penetration and 1/2" from the edoe of the toe of the welds described above.
4/22/2006 2 R0246T08- Outer and inner equalizing valves. VT-3 None Accept 2-AIRLOCK-C650 electrical penetration bolting 4124/2006 2 R0267461- for inner and outer doors, both sides. 2-02 UPLODE-BOLTING (16), 2-UPLIDE-BOLTING VT-1 None Accept V
I 1 1 (16)_
References:
- 1) NED-1999-00004, Revision 0, "ISI Acceptance Criteria for Containment Liner Thickness, Sargent & Lundy Report No. SL-53 60, Rev. 0" 26
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 7 ABSTRACT OF EXAMINATIONS, RESULTS AND CORRECTIVE ACTIONS FOR STEAM GENERATOR EDDY CURRENT EXAMINATIONS 2004 Steam Generator In-Service Inspections During October of 2004, eddy current inspections were conducted on the Unit 2 steam generators. Based upon the favorable results of this inspection and in accordance with the provisions of Technical Specification 4.4.5.3a, the Unit 2 steam generators continue to be on an inspection interval of up to 40 calendar months. As such, the Unit 2 steam generators will next be inspected in the fall of 2007.
27
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 8 NIS-2 REPAIR AND REPLACEMENT INDEX 28
U2C16 RepairReplacementReport Job Order Description Component Code Class R0099679-01 2-GRC-$555, REPLACE SNUBBER 2-GRC-$555 1 04305061-04 2-PP-50E, REPLACE PUMP W/ SS PUMP 2-PP-50E 2 04318017-01 2-MRV-232, REPAIR LEAK (INTERNALS, BIB BOLTING) 2-MRV-232 2 R0238854-13 2-VCR-20, REPLACE BONNET/BOLTING 2-VCR-20 2 R0266622-05 2-SV-45A, REPLACE SAFETY VALVE 2-SV-45A I 05340018-01 2-CS-536, REPLACE INTERNALS 2-CS-536 2 05340007-01 2-CS-534, REPLACE INTERNALS 2-CS-534 2 05340017-01 2-CS-535, REPLACE INTERNALS 2-CS-535 2 04322047-01 2-OME-4, REPLACE MANWAY BOLTS 2-OME-4 1 R0036212-01 2-GRC-S573; REPLACE SNUBBER 2-GRC-$573 1 R0098999-01 2-GRC-S538, REPLACE SNUBBER 2-GRC-$538 1 05340020-01 2-SI-210, REPLACE BOLTING 2-SI-210 2 R0246231-01 2-SV-104E, REPLACE BOLTING 2-SV-104E 2 R0036689-01 2-AFW-S4032-U, REPLACE SNUBBER 2-AFW-S4032-U 2 02346033-12 2-MRV-223, REPLACE BOLTING 2-MRV-223 2 05336016-01 2-MRV-242, REPLACE INTERNALS 2-MRV-242 2 06013029-13 2-PP-50W, CUT/REPLACE PIPE WELD 2-PP-50W 2 06040073-01 2-PP-50W, REPLACED GLAND PLATE/BOLTING 2-PP-50W 2 R0240871-01 2-CCR-457, REPLACE INTERNALS 2-CCR-457 2 04305061-28 2-PP-50E, INSTALL CCP SUCTION PIPING 2-PP-50E 2 04305061-27 2-PP-50E, INSTALL CCP DISCHARGE PIPING 2-PP-50E 2 R0226722-01 2-SV-104W, REPLACE VALVE AND BOLTING 2-SV-104W 2 R0037674-01 2-GBD-S568, REPLACE SNUBBER 2-GBD-S568 2 05121006-01 2-NRV-153, REPLACE INTERNALS 2-NRV-153 1 05237040-17, 2-OME-4, WELDED PREEMPTIVE WELD OVERLAYS 2-OME-4 1 18,22,23,27,28 ON DISSIMILAR METAL WELDS ON SAFETY, RELIEF, 32,33,37,38,43 SPRAY, AND SURGE NOZZLES 29
INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 2 BRIDGMAN, MI COMMERCIAL SERVICE DATE 7-1-1978 SECTION 9 NIS-2 REPAIR AND REPLACEMENT REPORTS 30
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/19/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GRC-S555 Name One Cook Place, Bridngman, MI 49106 JOB ORDER No. R0099679-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridclman. MI 49106 Expiration Date N/A Address
- 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, P0) ed (Yes or No) 2-GRC-$555 SNUBBER GRINNELL M&E 30-024683 N/A S/N 33021 N/A Replacement NO ASP 30610 SEAL KIT GRINNELL M&E 30-025055 N/A N/A N/A Replacement NO ASP 30463 "A" SEAL KIT GRINNELL M&E 30-040590 N/A NIA N/A Replacement NO ASP 28096 PISTON BUSHING GRINNELL M&E 30-024790 N/A NIA N/A Replacement NO ASP 16978
- 7. Description of Work REPLACED SNUBBER WITH REBUILT
- 8. Test Conducted: Hydrostatic D Pneumatic [] Nominal Operating Pressure D Other nX VT-3 Pressure NIA psi. Test Temp. NIA F INI T 31
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File R0099679-01
- 9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC EMENT conforms to the rules of the ASME Code, Section XN. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed n4l')ý Maintenance Weldina Supervisor Date 0
,2O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS - h ve Inspected the components described in this Owner's Report during the period to 6*/,,24'-, , and state that to the best of my knowledge and belief, the Owner has p&rforrned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in ankynanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspejtioit./
j imissions Af/ 6e76rV7-f
.ctor's Signalure National Board, State, Province, and Endorsements
,/,/,gZ- 20Q6 3a-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/14/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50E Name One Cook Place. Bridqman, MI 49106 JOB ORDER No. 04305061-04 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
- 4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ASME SEC III CL2 1986 Ed, N/A Add. Code Case.
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989,. No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50E PUMP N/A M&E 30-014849 NA ASME SA1 82 N/A REPLACED YES CASING ASP 31062 TP304
- 7. Description of Work REPLACED PUMP
- 8. Test Conducted: Hydrostatic F-- Pneumatic 1 Nominal Operating Pressure Other F INSERVICE VT-2 Pressure psi. Test Temp. _ F
-33
Page 2 of 2 FORM KIS-2 (Back)
Job Order/File 04305061-04
- 9. Remarks: Inservice VT-2 performed.
Applicable Manufacturer's Data Reports to be attached Serial# 05RLCA0321501001 DWG. 017571 Model2.5"RLIJ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Dew ne Trmns Mainter tance Welding Supervisor Date __/04 05_,204 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS / . have inspected the components described in this Owner's Report during the period '? to .5// . I and state that to the best of my knowledge and belief, the Owner hali perlormed; examinations'and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable inmny manner for any personal injury or properly damage or a loss of any kind arising from or connected with this =r.i.
Commissions AI.6 6e77 iff/ ':S/A7 r"'
National Board, 9tafe, Province, and Endorsements Inspec--or Signf lur Date 20 3,-I
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
As Required by the Provisions of the ASME Code, Section Ill, Division 1 2 Pg. I of.. "" ""
I. Manufacired and certifie* -'ve Pump Division, Nuclear Products Operation 2300 E. Vnmon Ave. Vernon, CA 90)05 (name and address of NCertificate Holder)
- 2. Manufactured forAmerican Elctric Power, Material Center,9970 Red Arrow ighwayBridgan,M]. 49106 Irama and address of Purchased Electric Power, D.C. Cook Plan4, 0;Cook .Pate,Bnidgman, M 60450
- 3. Location of C (name and address)
- 4. Model No., Series No., or Type 2.5"RL Drawing DWG17571 B CRN A 1986 W86 2 NA
- 5. ASME Code, Section 111,Division 1:
fedition) laddende date) (class) (Code Case no.)
Nominal Inlet size " Outlet size 3 1/8"
- 6. Pump or valve Pump (in.) (in.)
NA Disk NA BoNAtng NA
- 7. Material: Body NBonnet
[a) (b) Ic) Id) le)
Cert. Nat'l Body Bonnet Disk H.older's Board., . Serial serial Serial Serial No. No. No. No. No.
05RLCA0321501001 NA NA NA NA Supplemental information In form of lists. sketches. or drawings may be used provided (1) size is BY& X 11. (2) Information in itein'1 through 4 on this Data Report Is Included on each sheet. (3) each sheet is numbored and the number of sheetss rencorded at the top of this form' (1.2188) This form (EDD0371 may be obtained from the Order Dept., ASME. 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300. REPRINT GM I
- .-. -z ---
~ ., ,
0351)
.,_ =. ....
-o. ............. FFORM NPV-1. (Back - Pg. 2 of. O A21 Certificate Holder's Serial No. 05LA0321501001
- 8. Design cond'citions *f psi 300 IF or valve pressure class NA (1l (prea*srel ltemperature)
- 9. Cold workInj'-ssjre NA psi at i"OOF
- 10. Hykirostatic test 52601400 psL Disk differential test pressure NA psi
- 11. Remark.. Namplate attacbed by dCive pis.
Job Number: RLCA03215 Prodaction Order: RLSA08607
- D 'i:CERTIFICATION OF DESIGN Design Specification certified by AlbeTt John Wettlaufer P.E. State PA Reg. no. 13335-E Design Report certified by D. G. Bowman P.E. State CA Reg. no. NA CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.
N Certificate of Authorization No N14130 JeIres Jte] 0, 2008 D 321/o6 - erv Pump Division, Nuclear Products Ope- ed IN Certificate Holderd (aUt.ot re.........e CERTIFICATE OF INSPECTION I. the undersigned, holding a valid'commission issued by the National Board of Boiler and Pressure Vessel Inspectc;rs and the State or Province of Caffoania and employed by HSB-CT of Har-forL CT' have inspectea the pump, or valve, described in this Data Report on 32121/2006 , and state that to the best of my knowledge and belief. 1ie Certificate Holder has corn structed this purrp*.or valve, in accordance with the ASME Code, Section IIl, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or ss of any kind arising from or connected with this Inspection.
Date 3/21/2006 Signed .. OCommissions (Authorized Int ector)
CA 1969 rind. andorsemerits) and Suite or proy. and no.]
lNatL Betd.
(1) For manually operated valves only.
SIMP REVIEWiED AND ACCEPTED .
DA 15 10
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/22106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-MRV-232 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 04318017-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. Ml 49106 Expiration Date N/A Address
- 4. Identification of System: MAIN STEAM SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 NIA Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-MRV-232 STEM N/A M&E 30-688864 N/A ASTM A276 N/A REPLACED NO ASP 28532 TP 316 PLUG N/A M&E 30-688864 N/A ASTM A582 N/A REPLACED NO ASP 28532 TP 416 CAGE N/A M&E 30-688865 N/A ASTM A747 N/A REPLACED NO ASP 17265 CB7CU-1 1/2" STUD M&E 30-688868 N/A ASTM A193 N/A REPLACED NO MATERIAL ASP 28601 GR B7 1/2" NUT M&E 30-688869 N/A ASTM A194 N/A REPLACED NO ASP 28601 GR2H
- 7. Description of Work REPLACED STEM, PLUG AND BONNET BOLTING
- 8. Test Conducted: Hydrostatic s1 Pneumatic ] Nominal Operating Pressure Other __Pressure psi. Test Temp. _ F 37
'NIT-4
Page 2 of 2 FORM NIS-2 (Back)
Job OrderlFile 04318017-01
- 9. Remarks:.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed ýhievrIM4VDIPTI_ý Owner or Owner's Designee, Title Maintenance Welding Supervisor Date r P " 20 i CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period ____ ______to ...-- /,. and state that to the best of my knowledge and belief, the Owner has performed examinations 6nd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti
- Commissions X18 Inspedor's Signature' "*L___. National Board, State, Province, and Endorsements Date__ _ _
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/17/06 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-VCR-20 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. R0238854-13 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: ICE CONDENSER SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case N-522 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-VCR-20 VALVE BONNET N/A M&E 30-039707 NA ASTM A445 N/A REPLACED NO ASP 31147 66T
/2k NUT N/A M&E 30-212070 NA ASME SA194, N/A REPLACED NO ASP 22002 GR 8F Y2' STUD N/A M&E 30-040599 NA ASME SA 453 N/A REPLACED NO MATERIAL ASP 27052 GR 660
- 7. Description of Work REPLACED BONNET ASSY AND BOLTING.
- 8. Test Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D-]
Other D APPENDIX J TEST PER CC N-522 Pressure psi. Test Temp. F 3q IN~F~
Page 2 of 2 FORM4 NIS-2 (Back)
Job Order/File R0238854-13
- 9. Remarks: APPENDIX J TEST PER CC N-522 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A rin
ý rýM Signed TThwavn~ Maintet niance Weldino Supervisor Date 220 4-d5 onsDesignee, aintenance Title Welding SUDervisor v or Ownerv;a n Owner's
?e--Tri V-'e4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS , / bave inspected the components described in this Owner's Report during the period to ,and state that to the best of my knowledge and belief, the Owner trs p6rformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and ffective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be lia n any manner for any personal injury or property damage or a loss of any kind arising from or connected with th s ction.
Commissionsjf 9 , qw National Board,1State, Province, and Endorsements 9/0
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/14106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SV-45A Name One Cook Place, Bddcman. MI 49106 JOB ORDER No. R0266622-05 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed. N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of. Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SV-45A SAFETY VALVE CROSBY M&E 30-036392 NA S/N N/A REPLACED NO ASP 30673 RV-1-8010A
- 7. Description of Work REPLACED VALVE
- 8. Test Conducted: Hydrostatic D Pneumatic Nominal Operating Pressure
. t..hOher- . VT-2 at NOP/NOT, VT-3 Pressure psi. Test Temp. F i7-/
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File R0266622-05
- 9. Remarks: NOP/NOT VT-2 performed. VT-3 on internals Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed mons Maintenance Weldina Suoervisor r I Date ,20 6" Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period Z/,* to ,Z/,ll/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
7227...............
Commis*sions m, 16/9*- //~,
spector's Sigr dure National Board, State, Province, and Endorsements Date 20 66 2,_
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date ' 04/09106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CS-536 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05340018-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A
. Address
- 4. Identification of System: , CHEMICAL AND VOLUME CONTROL S' YSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification o f Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component .Manufacturer Serial No.' Board Ideteification Built Replaced, Code (Material M&E. No. or Replacement Stamped ASP, PO) (Yes or No) 2-CS-536 VALVE CENTER N/A M&E 30-033374 NA ASME SA479 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY
- 7. Description of Work REPLACED C:ENTER SECTION ASSEMBLY
- 8. Test Conducted: Hydrostatic 0 Pneumatic 1- Nominal Operating Pressure Other M Pressure psi. Test Temp. _ F INr q3
Page 2 of 2 FORM NIS-2 (Back)
Job OrderlFile 05340018-01
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed ae wiemmons ... .. ... .. . .
ce . .. lin ... -- -o r" Date elin uorisr M~ntnnc ,20696 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS / have inspected the components described in this Owner's Report during the period __ ____-_-_____ _to le-*7 d('. , and state that to the best of my knowledge and belief, the Owner has performed examinations and faken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in a manner for any personal injury or. property damage or a loss of any kind arising from or connected with this inspec Commissions {,'d y2 ///
) National Board, State, Pr6vinime, and Endbrsements
/ q/q
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC IPOWER Date 04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CS-534 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05340007-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: CHEMICAL AND VOLUME CONTROL SYSTEM ISI CLASS 2
- 5. (a) Applicable Const Code ANSI B31.1 1983 Ed, NIA Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-CS-534 VALVE CENTER N/A M&E 30-013933 NA ASME SA579 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY
- 7. Description of Work, REPLACED CENTER SECTION ASSEMBLY
- 8. Test Conducted: Hydrostatic l Pneumatic -- Nominal Operating Pressure 1 Other F1 Pressure . psi. Test Temp. _ F
?fl
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File 05340007-01
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A 4
Signed intenance Weldina Suoervisor Date 4e,? 7-. ,2092
.1 Owner or Owner's Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON. TEXAS / havye inspected the components described in this Owner's Report during the period /j/..///4. to - and state that to the best of my knowledge and belief, the Owner ha's peff6rmed examinationVsard taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectiop.
,missions AJA O!nr -§/9. 2 L
.. 2 7c
'/4
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner AMERICAN ELECTRIC POWER Date 04109)/O6 Name P.O. Box 60 Fort Wayne. IN 46B01 Sheet I of 2 Address Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CS-535 Name One Cook Place, Bridgman, MI 49105 JOB ORDER No. 05340017-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A Onp Ccnnk Plhqn Bridnman. MI 4910B Expiration Date N/A Address
- 4. Identification of System: CHEMICAL AND VOLUME CONTROL SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda S. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-CS-535 VALVE CENTER N/A M&E 30-013933 NA ASME SA479 N/A REPLACED NO SECTION ASP 31038 TP 316 ASSEMBLY
- 7. Description of Work REPLACED CENTER SECTION ASSEMBLY
- 8. Test Conducted: Hydrostatic M Pneumatic D Nominal Operating Pressure Other [-"] Pressure psi. Test Temp. _ F lWlT5
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File 05340017-01
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are crrect and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed M~int~n~nce W~Idino Suoeivisor Date "ze2 20 Owner or Owner o Owner's Owner'stenance Desiig neerT.t Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS havedinspected the components described in this Owner's Report during the period /__ -____to -. .- , and state that to the best of my knowledge and belief, the Owner has performed examinations ar'd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecfibo f&
~~--Comr issionls A 6 i ~/3£V?
Inspector's Signature " P National Boar, State, Pr-vitnd, -a-a-E-o--o-en-t z Date C"/hs 205
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 11/21 1/04 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-OME-4 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 04322047-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106
.... ...... ..... i I 1 Expiration Date N/A Address
- 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
- 5. (a) Applicable Const. Code ASME SEC. III 1986 Add. Code Case (b) Applicable Edition bf Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-OME-4 PRESSURIZER MANWAY BOLT N/A M&E 30-009772 NA ASME SA193 N/A REPLACED NO ASP 16387 GR B7
- 7. Description of Work REPLACED 2 BOLTS AT MANWAY
- 8. Test Conducted: Hydrostatic [, Pneumatic R- Nominal Operating Pressure LI1 Other "- VT-2, VT-1. PT Pressure A'OP psi. Test Temp. Žv.OQ F
-jjj Wrr- Jv-bý2
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File 04322047-01
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed D 0yne hmmons Owner or Owner's Designee, Title Maintenance Weldina Suoervisor
.... 1 i* -- [ .. ....
Date 40ý 21, 2 0 6; I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Ves~el Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS , , haye inspected the components described in this Owners Report during the period 4 7E Y to and state that to the best of my knowledge and belief, the Owner has 15erforfned examinations 'and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in an manner for any personal injury or property damage or a loss of any kind arising from or connected with this insm .oi.
/"
,5-0
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/20/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GRC-S573 Name One Cook Place, Bridgman, M1 49106 JOB ORDER No. R0036212-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, NIA Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-GRC-S573 SNUBBER GRINNELL M&E 30-024683 N/A SIN 33294 N/A Replacement NO ASP 30495 SEAL KIT GRINNELL M&E 30-025060 N/A N/A N/A Replacement NO ASP 26432 "A" SEAL KIT GRINNELL M&E 30-040591 NIA N/A N/A Replacement NO ASP 28476 ROD BUSHING GRINNELL M&E 30-024791 NIA GRINNELL N/A Replacement NO ASP 30165
- 7. Description of Work REPLACED SNUBBER WITH REBUILT
- 8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure Other F11 VT-3 Pressure NIA psi. Test Temp. NIA F 51
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File R0036212-O1 0 MOrnn-.. a.U..n~
/rr_*
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC EMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type.Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed D e V;rieýo ns~ itenance Weldinri Supervisor Date .20 2,0 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS ./ , .. hayv inspected the components described in this Owner's Report during the period to ,A_0/!//i'6o4 , and state that to the best of my knowledge and belief, the Owner has pOrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i econ.
Commissions 7 0 c 17.
National Board, State, Province, and Endorsements Date
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/19106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GRC-S538 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. R0098999-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place,. Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: REACTOR COOLANT SYSTEM IS[ CLASS 1
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-GRC-S538 SNUBBER GRINNELL M&E 30-024681 N/A S/N 33020 N/A Replacement NO ASP 29340 SEAL KIT GRINNELL M&E 30-025055 N/A N/A NIA Replacement NO ASP 17001 "A" SEAL KIT GRINNELL M&E 30-040590 N/A N/A N/A Replacement NO ASP 21030
- 7. Description of Work REPLACED SNUBBER WITH REBUILT
- 8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure D Other I VT-3 Pressure N/A psi. Test Temp, N/A F 5-3 INIT-
Page 2 of 2 FOR~M NIS-2 (33ack)
Job Order/File RD09899MlO
- 9. Remarks:, Vr-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Signed ,
66,~rrn'
-- .... r.* ................
4 2 Maintenance Weldina Suoervisor f
... .. .. f n Date ,20 200, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS /. hýe inspected the components described in this Owner's Report during the period W O'//,5- to: e//l/V1, , and state that to the best of my knowledge and belief, the Owner has performed examinations~and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable,
- any manner for any personal injury or property damage or a loss of any kind arising from or connected with this kts6)ction.
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date ' 04/09/06 Name P.O. Box 60 Fort Wayne, IN 46801 Rh__f 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SI-210 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05340020-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date NIA Address
- 4. Identification of System: SPENT FUEL POOL SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XA Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SI-210 VALVE W THREADED N/A M&E 30-212280 NA ASME SA453 N/A REPLACED NO ROD ASP 23399 GR 660 1/" HEX NUT N/A M&E 30-212070 NA ASME SA194 N/A REPLACED NO ASP 22002 SA194, GR I 8FGR 8F
- 7. Description of Work REPLACED BONNET BOLTING 8.. Test Conducted: Hydrostatic D Pneumatic -" Nominal Operating Pressure Other D Pressure psi. Test Temp.. F INIT 9.
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File 05340020-01
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed Maintenance Welding Supervisor Date e,, . 20 '
Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC.. of HOUSTON, TEXAS h ve spected the components described in this Owners Report during the period ,s
ýe C to e) and state that to the best of my knowledge and belief, the Owner h~s Performed examinations an6 taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins tiotn.
./t
,c.,,,,..- Commissions /,6,1'7 /// a,---
........ Inspector's-Signature-- National Board, Stafe, Province, and Endorsements Date C/e' 206:r
FORM NIS-2 OWNER'S REPORT FOR-REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/19/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SV-104E Name One Cook Place, Bridgqman, M1 49106 JOB ORDER No. R0246231-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. NIA One Cook Place. Bridoman. MI 49106
.............. i .... i f ...... i - .- , .
Expiration Date N/A Address
- 4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1992, Addenda 92
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SV-104E 5/8"THREADED N/A M&E 30-212290 NA ASME SA453 NIA REPLACED NO ROD ASP 29520 GR 660 5/8' NUTS NIA M&E 30-212090 NA ASME SA194 NIA REPLACED NO ASP 30787 GR8F 5/8' NUTS NIA M&E 30-212089 NA ASME SA194 N/A REPLACED NO ASP 25904 GR 8M
- 7. Description of Work REPLACED BOLTING
- 8. Test Conducted: Hydrostatic "- Pneumatic F-1 Nominal Operating Pressure [l Other D'] INSERVICE VT-2 Pressure psi. Test Temp. F 1
lNtTr
.27WOe/'
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File R0246231-01
- 9. Remarks: Inservice VT-2 performed.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR& REPLACEMENT conforms to the rules of the ASME Code, Setrion X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expirati on Date N/A Signed DeWnevm M~int~n~nr~ W~ldinr, ~nr~rvkor Date ,-*.-_-. ? 20 £9 0 Maintenance Weldinn Sunerviso Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON, TEXAS f I- haveinspected the components described in this Owner's Report during the period -__.vlorl to , /, and state that to the best of my knowledge and belief, the Owner has performed examinations an(I taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insp$con.
Commissions AMe 6z17 7.,tz--
0/ (3and National Board, State, Province, (5(7,9 Endorsements Date '*,-a 20 d r.
5-7
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl
- 1. Owner AMERICAN ELECTRIC POWER Date 04/20/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-AFW-S4032-U Name One Cook Place, BridQman, MI 49106 JOB ORDER No. R0036689-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqrnan, MI 49106 Expiration Date N/A Address
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed. N/A Add. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, *No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-AFW-4032-U SNUBBER GRINNELL M&E 30-024683 N/A S/N 32463 N/A Replacement NO ASP 29372 SEAL KIT GRINNELL M&E 30-025060 N/A NIA N/A Replacement NO ASP 26432 "A" SEAL KIT GRINNELL M&E 30-040591 N/A NIA N/A Replacement NO ASP 28476
- 7. Description of Work REPLACED SNUBBER WITH REBUILT
- 8. Test Conducted: Hydrostatic -- Pneumatic [_] Nominal Operating Pressure I Other F11 VT-3 Pressure NIA psi. Test Temp. N/A F 51 INff~
1'f A
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File RO0366Sg.M1
- 9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLAC EMENT conforms to the rules of the ASME Code, Section XN . repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed ;4weavnZ0imm(Qhs Meaintenance Weldina Sunervisor Date ",Av ' 20 e Owner orbOwners Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michioan and employed by ABS GROUP INC. of HOUSTON, TEXAS , t. hav/einspected the components described in this owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner hIasj frformed examinations-dni taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabJe1i any manner for any personal injury or property damage or a loss of any kind arising from or connected with thirs tion.
/(~G*
issA~
Cmkions w /46? 6i-Y /4 ::?,ic-~
Stat* Province, and Endorse-rnen*
ff
- I .
- w F Inspector's SgnaW// National Board, Board, State,~ Province, K and EndorsementsI Date cý 20 F6 10D
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/22/06 Name P.O. Box 60 Fort Wayne, iN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-MRV-223 Name One Cook Place. Bridaman. MI 49106 JOB ORDER No. 02346033-12 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization" No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: MAIN STEAM SYSTEM IS1 CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-MRV-223 1" BOLT M&E 30-039909 N/A ASME SA193 N/A REPLACED NO ASP 29981 GR B7 1" NUT M&E 30-039910 N/A ASTM A194 NIA REPLACED NO ASP 29981 GR 2H
- 7. Description of Work REPLACED BONNET BOLTING
- 8. TestConducted: Hydrostatic F Pneumatic F-] Nominal Operating Pressure F-1 Other L] Pressure psi. Test Temp. _ F lNITZ--f
Page 2 of 2' FORM NIS-2 (Back)
Job OrderlFile 02346033-12
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed De1Ivn~mon Maintenance Welding Supervisor Date 20 2Q.,*
Owner or Owner's Designee, Title
- CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS have ispected the components described in this Owner's Report during the period to ""-/-- , and state that to the best of my knowledge and belief, the Owner has performed examination" and' taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exafninations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti n.
1//§ _ ___ Commissions t'%7,Y // " -
SB-National /S ', , -".and Endorsements
-rovince, 6oziard/StatePoi& ndrent
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date . 04/06/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-MRV-242 Name One Cook Place, BridQman, MI 49106 JOB ORDER No. 05336016-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
- 4. Identification of System: MAIN STEAM SYSTEM IS!CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-MRV-242 VALVE CAGE M&E 30-688865 N/A ASTM A747 N/A REPLACED NO ASP 27541 CB7CU SEAT RING M&E 30-040120 NIA ASTM A582 N/A REPLACED NO ASP 30215
- 7. Description of Work REPLACED CAGE AND SEAT RING.
- 8. Test Conducted: Hydrostatic 1 Pneumatic Lý . Nominal Operating Pressure F-1 Other _- _ Pressure psi. Test Temp. _ F
[Nnr4s
Page 2 of 2 FORM H-IS-2 (Back)
Job Order/File 05336016-01
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Exiration Date N/A Signed DL4a ?Vne-pZ s Moi ntenance Weldina Suoervisor Date ,20 6' Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS I ý have'nspected the components described in this Owner's Report during the period 0 .1/14./Oq to a, and state that to the best of my knowledge and belief, the Owner 6as ferformed examinatlorf and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examination ando rrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be b in any manner for any personal injury or property damage or a loss of any kind arising from or connected with i pection.
1>;
... ....... m/ , .,-
Uommlssions' ~" I ' l1 ' _ 1:
1 National Board: State, Province, and Endorsements
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/01106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50W Name One Cook Place, Bridqrman, MI 49106 JOB ORDER No. 06013029-13 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type.Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date NIA Address
- 4. Identificafion of System: EMERGENCY CORE COOLING SYSYEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case N-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50W WELD FILLER N/A M&E 30-044990 NA ER 308/308L N/A REPLACED NO MATERIAL ASP 29426 &
29734
- 7. Description of Work CUT WELD FOR ACCESS AND REWELDED
- 8. Test Conducted: Hydrostatic 0 Pneumatic NominalOperating Pressured Other F-] PT, RT. VT-2 SYSTEM LEAKAGE Pressure psi. Test Temp.
F INIT
Page 2 of 2 FORK NIS-2 (Back)
Job Order/File 06013029-13
- 9. Remarks: Reweld after cutout. PT, RT, VT-2 performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed -wavng"rimrmons Maintenance Welding Suoervisor Date , .20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS'GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period Zq/..-.'. to v.-'; //d!C , and state that to the best of my knowledge and belief, the Owner has perforfied examinations and'taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inarr manner for any personal injury or property damage or a loss of any kind arising from or connected with this insp tio Commissions Inspector's Signagr6 _ National Board, State, Province, and Endorsements Date '/17 2009
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/04/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50W Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 06040073-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50W MECHANICAL FLOWSERVE M&E 30-015098 NA ASME SA479 N/A REPLACED NO SEAL ASP 31037 TP316 MECHANICAL FLOWSERVE M&E 30-015099 NA ASME SA479 N/A REPLACED NO SEAL ASP 31037 TP316 SCREW FLOWSERVE M&E 30-211426 NA ASME SA193 N/A REPLACED NO ASP 31036 GR B6
- 7. Description of Work REPLACED MECHANICAL SEALS INCUDING GLAND PLATE AND SCREWS
- 8. Test Conducted: Hydrostatic E- Pneumatic 0 Nominal Operating Pressured Other L.] INSERVICE VT-2 Pressure _psi. Test Temp. __ F IAN 6-7
Page 2 of 2 FORM NIS-2 (Back)
Job OrderlFile 60400073-01
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report-are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed De av~neýriosg Maintenance Weldina Sunervisor
. . . . i i I Date eA -5 ,20_____
Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS have inspected the components described in this Owner's Report during the period ,- *-'(. to 7- ,aV-0.C, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions ,V. 2 1614!3' J*pe-Ctor0s'@igrZture National Board, State, Province, and Endorsements Date X*-2"5e 20 6
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date ,04/15106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-CCR-457 Name One Cook Place, Bridqman, MI 49106 JOB ORDER No. R0240871-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: COMPONENT COOLING WATER SYSTEM ISl CLASS 2
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No.. or Replacement Stamped ASP, PO) (Yes or No) 2-CCR-457 CAGE N/A M&E 30-040752 NA ASTM A747 N/A REPLACED NO ASP 6286 " CB-7 STEM N/A M&E 30-041238 NA ASTM A479 N/A REPLACED NO ASP 11451 GR 316 PLUG N/A M&E 30-040999 NA ASTM A582 N/A REPLACED NO ASP 18102 TP 416A
- 7. Description of Work REPLACED STEM, PLUG AND CAGE.
- 8. Test Conducted: Hydrostatic Di Pneumatic El Nominal Operating Pressure F1 Other I' . Pressure psi. Test Temp. _ F II /Y211 lNIT~
Page 2 of 2 FORM NIS-2 (Back.k)
Job Order!Fie R0240871-01
- 9. Remarks:
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed 4 Maintenance Welding Supervisor Date ____2 ___ ________, 2O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS .hve, inspected the components described in this Owner's Report during the period to ,7--/t'! and state that to the best of my knowledge and belief, the Owner has'performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspettor nor his employer shall be liable in a anner for any personal injury or property damage or a loss of any kind arising from or connected with this i p Di n Commissions ,"//. -c9,-
Inspector's Signature National Board, State, Province, and Endorsements Date F0,// 0 70
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04/14/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50E Name One Cook Place, Bridqman, Ml 49106 JOB ORDER No. 04305061-28 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI 1B31.1 1983 Ed, N/A Add. Code CaseN-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50E FILLER N/A M&E 30-044990 ER308/308L N/A REPLACED NO MATERIAL ASP 29734&
27174 3" ALL THREAD N/A M&E 30-212295 NA ASME SA453 N/A REPLACED NO ASP 23051 GR 660
% HEX NUT N/A M&E 30-046903 NA ASME SA1 94 NIA REPLACED NO ASP 15347 GR8F
- 7. Description of Work REPLACED FLANGE BOLTING AND REWELDED PIPE
- 8. Test Conducted: Hydrostatic El Pneumatic Nominal Operating Pressure F-Other F-1 PT, RT, INSERVICE VT-2 Pressure psi. Test Temp. F 7/ lIT~
Page 2 of 2 FORIH NIS-2 (Back)
Job Order/File 04305061-28
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date NIA Signed D4 ayl ogns Z Maintenance Weldinq Supervisor Date 20 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS .hve ins ected the components described in this Owner's Report during the period 2.__,"- to Sb,*f5/t_ " , and state that to the best of my knbwledge and belief, the Owner has peIrformed examinations and-ftaken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and coq ctive measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liav.'ý ir)any manner for any personal injury or property damage or a loss of any kind arising from or connected with this '*.V ton.
(0AI cý77 r IWI a&Zýcq 7(---
National Board, State, 'Pro{,ince, and Enidorsements
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04114106 Name P-O. Box 60 Fort Wavnn. IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-PP-50E Name One Cook Place. Bridaman. MI 49106 JOB ORDER No. 04305061-27 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp NIA Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date NIA Address
- 4. Identification of System: EMERGENCY CORE COOLING SYSTEM IS1 CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A " Add. Code CaseN-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code "
(Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-PP-50E FILLER N/A M&E 30-045075 ER316/316L N/A REPLACED NO MATERIAL ASP 19713 1 W"ALL N/A M&E 30-212315 NA ASME SA453 N/A REPLACED NO THREAD " ASP 24977 GR 660 1 Y" N/A M&E 30-212142 NA ASME SA194 N/A REPLACED NO HEX NUT ASP 30823 GR 8F
- 7. Description of Work REPLACED FLANGE BOLTING AND REWELDED PIPE
- 8. Test Conducted: Hydrostatic l- Pneumatic F-1 Nominal Operating Pressure Other LI PT, RT, INSERVICE VT-2 Pressure psi. Test Temp. F 73
Page 2 of 2 FORM. NIS-2 (Balk)
Job OrderlFile 04305061-27
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed D v on Maintenance Welding Supervisor Date ,20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS 1 / have inspected the components described in this Owner's Report during the period *!99!Oy to 6-/i-/ , and state that to the best of my knowledge and -belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this. Owner's Report Furthermore, neither the Inspector nor his employer shall be liableAJq any manner for any personal injury or property damage or a loss of any kind arising from or conne4,cted with thishn bebtion.
7'-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 0411C /106 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-SV-104W Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. R0226722-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-SV-104W SAFETY VALVE N/A M&E 30-036394 NA ASME SA351 NIA REPLACED NO ASP 29057 GR CF8M 5/8" NUT N/A M&E 30-212089 NA ASME SA194 REPLACED NO ASP 25904 GR8F 5/8" THREADED NIA M&E 30-212290 NA ASME SA453 REPLACED NO ROD ASP 29520 GR 660 5/8" NUT N/A M&E 30-212090 NA ASME SA194 REPLACED NO ASP 30787 GR 8F
- 7. Description of Work REPLACED VALVE AND BOLTING
- 8. Test Conducted: Hydrostatic ED Pneumatic j-'- Nominal Operating Pressure -
Other F INSERVICE VT-2, Pressure _ psi. Test Temp. _ F 75-
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File R0226722-01
- 9. Remarks: Inservice VT-2 performed.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N(A Signed I nt~n2nt~ W~ldinri Suo~rvi~or Date . 20 41 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MichiQan and employed by ABS GROUP INC. of HOUSTON., TEXAS , , have ipspected the components described in this Owners Report during the period ____-_______ to. ,.17-/A ,and state that to the best of my knowledge and belief, the Owner I's pbrformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in azy manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecliorT.
76*
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04120106 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-GBD-S568 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. R0037674-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. NIA One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: STEAM GENERATOR BLOWDOWN SYSTEM ISI CLASS 2
- 5. (a) Applicable Const. Code ANSI B31.1 1983 Ed, N/A Add. N/A Code Case (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamp ASP, PO) ed (Yes or No) 2-GBD-S568 SNUBBER GRINNELL M&E 30-024682 N/A S/N 33301 N/A Replacement NO ASP 26349 SEAL KIT GRINNELL M&E 30-025055 N/A N/A N/A Replacement NO ASP 23443 "A" SEAL KIT GRINNELL M&E 30-040590 N/A N/A N/A Replacement NO ASP 21030 TAPER PiN GRINNELL M&E 30-024975 N/A GRINNELL N/A Replacement NO ASP 13571 FIG 312
- 7. Description of Work REPLACED SNUBBER WITH REBUILT
- 8. Test Conducted: Hydrostatic '-- Pneumatic -] Nominal Operating Pressure-Other Fxý VT-3 Pressure NIA psi. Test Temp. N/A F 77
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File R0037674-01
- 9. Remarks: VT-3 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed D nMaintenance Welding Supervisor Date 5 20 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by ABS GROUP INC. of HOUSTON, TEXAS -- have ispected the components described in this Owner's Report during the period ____ /___-__to , and state that to the best of my knowledge and belief, the Owner haE performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins nd Commissions A/6A? 97rY / ~ 7 Inspctors Si~atuNational Board, 8;tate, Province, and Endorsements
. Date V42QC 6-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner AMERICAN ELECTRIC POWER Date 04103/06 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
- 2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 2-NRV-153 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 05121006-01 Address Repair Org. P.O. No., Job No., etc
- 3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridoman, MI 49106 Expiration Date N/A Address
- 4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS I
- 5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 2-NRV-153 VALVE STEM NIA M&E 30-042247 NA HAYNES N/A REPLACED NO ASP 28948 ALLOY 25 PLUG N/A M&E 30-042070 NA ASTM N/A REPLACED NO ASP 26743 A479/276 T316
- 7. Description of Work REPLACED STEM AND PLUG
- 8. Test Conducted: Hydrostatic E' Pneumatic F Nominal Operating Pressure[
Other D1 VT-2 at NOP/NOT Pressure psi. Test Temp. F INIT'~
Page 2 of 2 FORM NIS-2 (Back)
Job Order/File 05121006-01
- 9. Remarks: VT-2 at NOP/NOT Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR& REPLACEMENT conforms to the rules of the ASME Code,Section X). repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date NIA Signed L-&avewy/M 411_1 Mairntenance Weldina Supervisor Date , 200*
Owner or-Owner's Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michiqan and employed by ABS GROUP INC. of HOUSTON, TEXAS / 4 haveyin pected the components described in this Owners Report during the period -____ _o-to
_ ___________ _ , and state that to the best of my knowledge and belief, the Owner has lperf6rmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or impried, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liabl in y manner for any personal injury or property damage or a loss of any kind arising from or connected with this ti n.
I, -. Commissions A[&0177 /g/ 8t~ZgS'z; Inspector's Sig2ature National Board, State, Province, and Endorsements Date LC I 206G __
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner Indiana Michigan Power Date Julv 19. 2006 Name P.O. Box 60, Fort Wayne, IN 46801 Sheet I of 22 Of Address
- 2. Plant D.C. Cook Nuclear Power Plant Unit 2 Name Berrien Cognt. Bridmman, M1 49106 see Remarks Addre= RepairReplacement Organization P 0 No, Job No, etz
- 3. Work Performed by AREVA NP Type Code Symbol Stapp NIA Name Authorization No. N/A 33"15 Old Forest Rd, Lynchbuugr VA 24501 Expiration Date NIA Address
- 5. (a) Applicable Construction Code ASME ITL 1998 Edition 2000 Addenda, None Code Case (b) Applicable Edition of Secti6n X) Utilized for Repair/Replacemrnt Activity-.1989 Edition, no Addenda (see Remarks)
(c) Applicable Section XI Code Case(s): N-638-1, N-416-1. N-504-2, N-460, 2142-2 (see Remarics)
- 6. Identification of Components Repaired or Replaced and Replacement Components.
- 7. Description of Work: Welded Preemptive Weld Overlays on Dissimilar Metal Welds on Safety, Relief. Spray and Surge Nozzles
- 8. Tests Conducted: Hydrostatic [] Pneumatic [E Nominal Operating Pressure R Other [] Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawifgs may be used, provided (I) size is 8 1/2x I1 in. (A4)
(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
nUrrT
FORM NIS-2 (Back) 0 7=
anrr Tn Appficable Manufarturer's Data Reports to be attached Line 2: AREVA Process Traveler Package Nos. 50-9007637-002, 50-9007639-002, 50-9007641-002 and AEP Job OrderNos. 05237040 17, 18, 22, 23, 27.28, 32, 33, 37, 38 and 43.
TAr~ ~(h~ rnr¶ (~"V SeLettr 1Nos AEP.NR t:555-1 3 AEP1-JRC:6V)5S AIEP.NRC:6055 5aSnd AFEP.NRC:05-A d Alternatives to ASME XI 1989 Edition, no Addenda and applicable ASME Section XI Code Cases CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section X)
Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Sirned Kv.'"D*.E ConsultantDa Date ) 0 11, ,20 06 Signed .......... Owner eor, or AR NeD Owner's eine T Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Micnigan and employed by ABS Consulting =nc.
of Houston, Texas have inspected the components described in this Owner's Report during the period November 9. 2004 to mti4ce &AIX 7"/'- o C, and state that to the best of my knowledge and belieý the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMIE Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any persona] injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions" /0M/,' AW/I ipector'i Signature National Board, State, Province, and Endorsements rMate 2QO,"