AEP-NRC-2008-12, Inservice Inspection Summary Report for Period of 11/14/2006 Through 04/29/2008

From kanterella
Jump to navigation Jump to search
Inservice Inspection Summary Report for Period of 11/14/2006 Through 04/29/2008
ML082180385
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/24/2008
From: Jensen J
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP-NRC-2008-12
Download: ML082180385 (89)


Text

Indiana Michigan Power Company INdDIANA MICHIGAN Nuclear Generation Group MICHIGAN One Cook Place Bridgman, MI 49106

  • I*WR aep.com July 24, 2008 AEP-NRC-2008-12 10 CFR 50.55a Docket No.: 50-315 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-PI-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 1 INSERVICE INSPECTION

SUMMARY

REPORT This letter provides a copy of the Inservice Inspection Summary Report for activities performed at Donald C. Cook Nuclear Plant (CNP), Unit 1, National Board (State of Michigan) Number, 20761 (Mich. M-096762-M), located in Bridgman, Michigan, for the period of November 14, 2006, to April 29, 2008. The plant is owned by Indiana Michigan Power Company, P.O. Box 60, Fort Wayne, IN, 46801.

The commercial service date of CNP Unit 1 is August 23, 1975, and the Authorized Code Inspector is Mr. R. K. Schenck, who is employed by OneCIS Insurance Co., of Boston, Massachusetts.

The examinations, tests, replacements, repairs performed, conditions observed, and corrective measures taken are summarized in the attached report. One required NIS-2, Owner Report of Repairs or Replacements, was not available for this Summary Report due to a missed preservice examination. This NIS-2 report will be provided in a subsequent submittal. Inservice inspection activities were performed in accordance with the rules and requirements of the American Society of Mechanical Engineers' Code,Section XI, 1989 Edition (no Addenda) and 1992 Edition with the 1992 Addenda, as applicable.

There are no new or revised commitments in this letter. Should you have any questions, please*

contact Mr. John A. Zwolinski, Regulatory Affairs Manager, at (269)-466-2478.

S~incelely, ZN. Jensen Site Support Services Vice President HLE/jen

Attachment:

Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant, Unit 1, Unit 1 Cycle 22, 2008 Refueling Outage. /7)

U. S.,Nuclear Regulatory Commission AEP-NRC-2008-12 Page 2 c: R. Aben - DLEG/BCCFS/BD T. A. Beltz - NRC Washington, DC J. L. Caldwell - NRC Region III K. D. Curry - AEP Ft. Wayne, w/o attachment J. T. King - MPSC, w/o attachment MDEQ - WHMD/RPMWS, w/o attachment NRC Resident Inspector

Attachment to AEP:NRC:2008-12 Inservice Inspection Summary Report for the Donald C. Cook Nuclear Plant Unit 1 Cycle 22 2008 Refueling Outage

SUMMARY

REPORT FOR THE DONALD C. COOK NUCLEAR PLANT'.

UNIT 1 Unit 1 Cycle 22 2008 REFUELING OUTAGE INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1, p- BRIDGMAN, MI.

COMMERCIAL SERVICE DATE 8-23-1975 Report for Inspection Period From November 14, 2006 to April 29, 2008 July 3, 2008 Prepared by: Date: _7-09" Paul Donavin ISI Program Owner Reviewed by: . /... t Date: 7-4 -0.

/Jim Fitchuk

  • -WlwLE/Lan.dubberProgram Owner Reviewed by: __Date: __1/____/_-___,

Pro ram Rodney Pickard Servir Reviewed by: Date: 7 5*'*

Carl Lane Pggrams Moager Approved by:( Z4~a tqr AC.66 5 Date:?71:

Q. Shane Lies

-Plant Engineering Director

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 Report of Inservice Inspections From November 14, 2006, to April 29, 2008 TABLE OF CONTENTS Section 1 Introduction 1 Section 2 NIS-1 Inservice Inspection Summary Report 2 Section 3 Examination of Class 1 and Class 2 Systems and Components 6 (Including Bottom Mounted Instrumentation)

Section 4 System Pressure Tests 15 Section 5 Snubber Tests 16 Section 6 ASME Section XI, Article IWE and IWL 18 Section 7 ASME Section XI, Steam Generator Eddy Current Examinations 20 Section8 NIS-2 Repair and Replacement Reports Index 21 Section 9 NIS-2 Repair and Replacement Reports 23

-i-

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 1 INTRODUCTION This report summarizes the Inservice Inspection activities performed at Donald C. Cook Nuclear Plant, Unit 1, for the period November 14, 2006, to April 29, 2008. This report addresses examinations and activities associated with the Third Ten-Year Interval's First Outage of the Third Inspection Period, Unit 1 Cycle 22 Refueling Outage. These activities were performed in accordance with the requirements of the ASME Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. The Third Ten-Year Inspection Interval began July 1, 1996, and continues through February 28, 2010. The applicable code of record for ISI activities is ASME Code Section XI, 1989 Edition (No Addenda) and 1992 Edition, 1992 Addenda, as applicable.

The purpose of this report is to satisfy the requirements of IWA-6000 for the submittal of an Inservice Inspection Summary Report at the completion of each refueling outage.

Examinations and tests conducted since the preceding summary report are included in this report. Repairs and replacements (for Class 1 and 2 Components) are also included in this report per the requirements of the 1989 Edition (No Addenda) and the 1992 Edition, 1992 Addenda of ASME Code Section XI, IWA-6220.

Contents of this report have been reviewed and verified correct with supporting documentation available at the plant for review if required.

1

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 2 NIS-1 INSERVICE INSPECTION

SUMMARY

REPORT 2

FORM NIS-1 OWNERS' DATA REPORT FOR TNSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner: Indiana Michigan Power Co., PO Box 60, Ft. Wayne, IN 46801 (A wholly owned subsidiary of American Electric Power)

(Name and Address of Owners)

2. Plant: Donald C. Cook Nuclear Plant, One Cook Place, Bridaman, MI 49106 (Name and Address of Plant)
3. Plant Unit: One
4. Owner Certification of Authorization (if required): N/A
5. Commercial Service Date: 08/23/75
6. National Board Number for Unit: 20761 (Mich. M-096762-M)
7. Components Inspected Component or Manufacturer or Manufacturer or State or Province National Board Appurtenance Installer Installer Serial Number Number Number Reactor Vessel Combustion CE 66105 M 96762 M 20761 I-OME-1 Engineering Steam Generator Babcock & Wilcox 7803-02 / 1121 M 96764 M 195 / 6831 1-OME-3-1 / Westinghouse Steam Generator Babcock & Wilcox 7803-02 / 1122 M 96765 M 193 / 6832 1-OME-3-2 / Westinghouse Steam Generator Babcock & Wilcox 7803-03 / 1124 M 96767 M 194 / 6834 1-OME-3-4 / Westinghouse Reactor Coolant Westinghouse I - 618J881 ........

Pumps PP-45-1 Excess Letdown Westinghouse 1158 Heat Exchanger (1-HE-13)

East Residual Heat Engineers and S-15586-A ---- 1102 Removal Heat Fabricators Exchanger (1-HE-17E)

West Residual Engineers and S-15586-B ---- 1103 Heat Removal Fabricators Heat Exchanger (1-HE-17W)

West Containment Yuba 69-G-226-1C ----....

Spray Heat Exchanger (I-HE-18W)

Component Grinnell Enclosed List ---- ----

Supports 3

NOTE: S/G's are a composite-original by Westinghouse

8. Examination Dates: November 14, 2006, to April 29, 2008
9. Inspection Period Identification: Third
10. Inspection Interval Identification: Third
11. Applicable Edition of Section XI 1989 (No Addenda) & 1992 Addenda 1992
12. Date/Revision of Inspection Plan: 7/96 Rev. 0
13. Abstract of Examinations. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

See Sections 3, 4, 5, 6, and 7

14. Abstract of Results of Examinations and Tests.

See Sections 3, 4, 5, 6, and 7

15. Abstract of Corrective Measures.

See Sections 3, 4, 5, 6, and 7 We.certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date: July 3, 2008 Signed: Indiana Michigan Power Co By::

Owner (Wholly Owned Subsidiary of AEP) 4

CERTIFICATE OF INSERVICE INSPECTION I, the .undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by One CIS Insurance Co.

of Boston, MA have inspected the components described in this Owner's Report during the period November 14, 2006 to April 29, 2008 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,-" Commissions Michigan 300959, NB 11412, Endorsements; A,N & I Inspector's Signature National Board, State, Province, and Endorsements Date '-" 1'" 3 2008 5

ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR CLASS 1 AND CLASS 2 COMPONENTS INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 3 Inservice examinations were performed during the period November 14, 2006, to April 29, 2008. This report addresses examinations and activities associated with the Third Ten-Year Interval's First Outage of the Third Inspection Period, Unit 1 Cycle 22 Refueling Outage. All examinations were in accordance with the ASME Code Section XI 1989 Edition (No Addenda) and 1992 Edition, 1992 Addenda, as applicable.

Examinations were scheduled and performed according to the Third Ten-Year Long Term Inservice Examination Plan for Class 1, 2, and 3 Systems and Components for Donald C. Cook Nuclear Plant (CNP), Unit 1. This is the currently-approved ISI examination plan that identifies specific activities to be performed on a refueling outage basis.

The scope of examinations also included the examination of the Unit 1 Reactor Pressure Vessel for evidence of Primary Water Stress Corrosion Cracking (PWSCC). The examinations for PWSCC were performed and documented in response to Nuclear Regulatory Commission (NRC) Bulletin 2001-01. No evidence of PWSCC was observed.

System pressure tests did not reveal any degradation of the system pressure boundary.

The operating group walkdown at 1000 psig discovered a socket weld leaking near 1 -NFP-222-V2 on the Loop 2 crossunder pipe. This was a non-isolable leak from the RCS. The socket weld was repaired, examined, and tested in accordance with Code Case N-666 and relief request ISIR-22.

Pipe support 1-GSI-L-47A was corrected under WO 55317177-01 and sample expansion under WO 55317451. Pipe support 1-GSI-L-53 was corrected under WO 55317887-01 and second sample expansion was conducted under WO 55317451 and WO 55317932.

The same supports in Unit 2 were examined to determine the extent of the condition. The Unit 2 supports were acceptable.

During a scheduled ISI depressurized walk down of 1-HE-13 (Excess Letdown Heat Exchanger), evidence of leakage was identified at the head to flange connection. The evaluation by the Boric Acid Program owner accepted the condition per CE 00828717-01. The results were acceptable and the VT-2 performed at nominal operating pressure did not identify any additional leakage.

Nondestructive ISI examinations were performed by Wesdyne (Westinghouse) and Indiana Michigan Power Company (I&M) personnel in accordance with procedures approved for use at CNP.

6

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam No. ComD. ID Comoonent Description Item Procedure Method/ReDort/Results Svstem Dw/IlSO, Date Class 1 Category B-B 011900 STM-11-01 S/G 11 B2.40 ISI-UT-208 UT/ UT-08-048 / Accept RC A-6 4/2/2008 Class 1 Category B-F 011200 1-PRZ-23 PRZ Nozzle Overlay B5.40 WDI-STD-1007 UT / UT-08-038 / Accept PRZ A4 4/8/2008 Class 1 Category B-G-1 006300 1-RPV-FLANGE Reactor Vessel Flange B6.40 WDI-SSP-1147 UT / UT-08-05 / Accept RPV A-86 4/18/2008 THREADS Class 1 Category B-J 129000 1-CS-96-57S Pipe Weld B9.21 WDI-STD-1 026 UT / UT-08-030 / Accept CVCS A75 4/5/2008 129100 1-CS-96-58S Pipe Weld B9.21 WDI-STD-1 026 UT / UT-08-047 / Accept CVCS A75 4/5/2008 129200 1-CS-96-59S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-024 / Accept CVCS A75 4/6/2008 129300 1-CS-96-60F Pipe Weld B9.21 WDI-STD-1026 UT UT-08-025 / Accept CVCS A75 4/6/2008 44700 1-RC-11-21S Pipe Weld B9.11 WDI-STD-1026, UT / UT-08-029 / Accept RC A28 4/3/2008 100800 1-SI-29-03S Pipe Weld B9.11 WDI-STD-1026 UT / UT-08-014 / Accept SI A53 3/31/2008 101000 1-SI-29-04F Pipe Weld B9.11 WDI-STD-1026 UT / UT-08-015 / Accept SI A53 3/31/2008 102100 1-SI-29-16S Pipe Weld B9.11 ISI-PDI-UT-2 UT / UT-08-018 / Accept SI A53 4/3/2008 7

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam No. ComD. ID Component Description Item Procedure Method/Reo~ort/Results System DwI/ISO Date 102200 1-SI-29-17S Pipe Weld 89.11 ISl-PDI-UT-2 UT! UT-08-019 / Accept SI A53 4/3/2008 102300 1-SI-29-18S Pipe Weld B9.11 ISI-PDl-UT-2 UT / UT-08-020 / Accept Si A53 4/3/2008 102400 1-SI-29-19S Pipe Weld B9.11 ISI-PDI-UT-2 UT / UT-08-021 / Accept SI A53 4/3/2008 102500 1-SI-29-20S Pipe Weld B9.11 ISI-PDI-UT-2 UT / UT-08-022 / Accept SI A53 4/3/2008 102700 1-SI-29-23S Pipe Weld B9.11 ISI-PDI-UT-2 UT / UT-08-023 / Accept SI A53 4/3/2008 104900 1-SI-31-17S Pipe Weld B9.11 ISI-PDI-UT-2 UT / UT-08-026 / Accept SI A54 4/4/2008 105000 1-SI-31-18S Pipe Weld B9.11 ISI-PDI-UT-2 UT / UT-08-027 / Accept SI A54 4/4/2008 105300 1-SI-31-21S Pipe Weld B9.11 lSl-PDI-UT-2 UT / UT-08-028 / Accept SI A54 4/4/2008 112454 1-SI-40-09S Pipe Weld B9.21 DIS-STD-1 026 UT / UT-08-032 / Accept SI A58 4/7/2008 112456 1-SI-40-109 Pipe Weld 8.9.21 WDI-STD-1026 UT / UT-08-033 / Accept SI A58 4/7/2008 112472 1-SI-40-18S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-039 / Accept SI A58 4/6/2008 112474 1-SI-40-19S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-040 / Accept SI A58 4/7/2008 112476 1-SI-40-20S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-041 / Accept SI A58 4/7/2008 112478 1-SI-40-21S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-042 / Accept SI A58 4/7/2008 112480 1-SI-40-22S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-043 / Accept SI A58 4/7/2008 112482 1-SI-40-23S Pipe Weld B9.21 WDI-STD-1026 UT /!UT-08-044 / Accept SI A58 4/7/2008 112484 1-SI-40-24S Pipe Weld B9.21 WDI-STD-1026 UT/ UT-08-045 / Accept SI A58 4/7/2008 8

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam No. Comr. ID ComDonent Description Item Procedure Method/Reoort/Results System Dwa/ISO Date 112486 1-SI-40-25S Pipe Weld B9.21 WDI-STD-1026 UT / UT-08-046 / Accept SI A58 4/7/2008

.112540 1-SI-51-28F Pipe Weld B9.21 ISI-PDI-UT-2 UT / UT-08-012 /Accept SI A59 3/30/2008 112542 1-SI-51-29F Pipe Weld B9.21 ISI-PDI-UT-2 UT / UT-08-013 /Accept SI A59 3/30/2008 122200 1-SI-548-45S Pipe Weld B9.40 WDI-STD-1026 UT / UT-08-031 / Accept SI A68 4/6/2008 Class 1 Category C-A 300360 STM-14-07 Shell to Transition Cone C1.10 ISI-UT-208 UT UT-08-017 Accept MS B-4 4/4/2008 300390 STM-14-10 Steam Generator No. 14 C1.20 ISI-UT-208 UT / UT-08-049 / Accept MS B-4 4/4/2008 300830 W-RHRHEX-2 Shell to Head C1.20 ISl-PDI-UT-2 UT / UT-08-001 / Accept RHR B-1 0 3/25/08 Class 1 Category C-B1 300190 300190_

STM-12-MSN STM-12-MSN _

Shell to Nozzle ShelltoNozzleC2.21 02.21 T12-QHP-5050-NDE-002 MT/ MT Report/Accept MT_/MTReprt/Accep T NMS MS_

.B-2 B-2_

4/5/2008 4/5/200800 300190 STM-12-MSN Shell to Nozzle C2.21 ISI-UT-208 UT / UT-08-016 / Accept MS B-2 4/2/2008 Class I Category C-D 317090 MSIV-MRV-210 Flange Bolting C4.40 lSl-PDI-UT-5 UT UT-08-002 / Accept MS B-75 3/28/08 9

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam Class I Category B-G-2 226300 1-RH-134 Flange Bolting B7.70 12-QHP-5050- VT VT-08-033 / Accept RH A-55 4/1/2008 NDE-006 Class 1 Category B-K-1.

100900 1-SI-29-03S-HL HangerLug 8310.10 12-QHP-5050- PT PT-08-001 / Accept SI A-53 4/2/2008 NDE-001 143700 1-RH-28-01S-HL HangerLug B10.10 12-QHP-5050- PT PT-08-002 / Accept RH A-80 4/4/2008 NDE-001 1 2-QHP-5050-149700 1-PP-45-3 Support Lug No. 1 B10.20 NDE-001 . PT / PT-08-005 / Accept RC N/A 4/13/2008 149800 11-PP-45-3 Support Lug No.2 B10.20 12-QHP-5050- PT / PT-08-006 / Accept RC N/A 4/13/2008 NDE-001 149900 1-PP-45-3 Support Lug No. 3 B10.20 12-QHP-5050- PT / PT-08-007 / Accept RC N/A 4/15/2008 149900_ 1-PP-45-3 _ SupportLugNo._3B10.20 NDE-001 Class 1 Category B-L-1 150000 1-PP-45-3 Pump Casing Weld B12.10 12.QHP-5050- VT VT-08-042 Accept RC N/A 4/13/2008 NDE-006 Class 1 Category F-A 1 2-QHP-5050- V T0-2 cet GI A5 /120 621875 1-GSI-R-566 Pipe Support Components Fl.10B ND-006 VT VT-08-028 Accept GSI A-58 3/31/2008 621900 1-GSI-V-156 Pipe Support Components F1.10WC 12-QHP-5050- VT / VT-08-005 / Accept GSI A-59 2/13/2008 NDE-006 626300 1-GSI-R-559 Pipe Support Components F1.10WB 12-QHP-5050- VT / VT-08-029 / Accept GSI A-72 3/31/2008 NDE-006 639500 1-GCS-R-601 Pipe Support Components F1IlOWB 12-QHP-5050- VT / VT-08-026 / Accept GCS A-78 3/31/2008

_NDE-006 _'

10

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam No. Como. ID ComDonent Description Item. Procedure Method/Reoort/Resu Its System Dwg/ISO Date 650200 1-PP45-3 RC Pump No. 13 Support F1.40 12-QHP50506 VT / VT-08-035 / Accept RC N/A 4/3/2008 Class 2 Category C-C 304945 1-RH-1-16F-PS Pipe Support C3.20 12-QHP-5050- PT / PT-08-003 / Accept RH B-27 4/10/2008 NDE-001 305275 1-RH-2-15F-PS Pipe Support C3.20 12-QHP-5050- PT PT-08-004 / Accept RH B-28 4/10/2008 305_75_ 1-RH-2-15F-PS_ PipeSupportC3.20 NDE-001 Class 2 Category F-A 700050 CS-S Bracket F1.40 12-QHP-5050- VT / VT-08-031 / Accept CTS B-5 3/30/2008 700050__CS-5_Bracket _F1.40_NDE-006 7000-60 CS-6 Bracket F1.40 12-QHP-5050- VT / VT-08-032 / Accept CTS B-5 3/30/2008 NDE-006 700170 W-RHRHEX-SC- West RHR HTEX F1.40 12-QHP-5050- VT / VT-08-018 / Accept RHRHEX B-10 2/27/2008 1 NDE-006 700180 W-RHRHEX-SC- West RHR HTEX Fl1.40 12-QHP-5050- VT/VT-08-019 /Accept RHRHEX B-1 2/27/2008 2 NDE-006 702260 1-GRH-V-53 Pipe Support Components F1.20C NDE-006 VT VT-08-037 / Accept GRH B-14 4/8/2008 702520 1-GSI-R-554 Pipe Support Component F1.20B 12-QHP-5050- *VT / VT-08-030 / Accept GSI B-16 3/31/2008 NDE-006 704700 1-GSI-V-608 12-QHP-5050- VT VT-08-036 / Reject Pipe Support Component F1.20C NDE-006 Note 1 GSI B-26 4/4/2008 704930 1-GRH-R-10 Pipe Support Component F1.20WA 12-QHP-5050- VT / VT-08-041 / Accept GRH B-27 4/10/2008 NDE-006 706200 1-GCTS-R-8 Pipe Support Component F1.20A NDE-006 VT VT-08-039 / Accept GOTS B-31 4/9/2008 706960 1-GSI-R-51 Pipe Support Component F1.20A 1 -QH-0506 VT /VT-08-043 / Accept GSI B-33 4/23/2008 NDE-006 707020 1-GSI-R-52 Pipe Support Component F1.20A 12-QHP-5050- VT / VT-08-044 / Accept GSI B-33 4/23/2008 NDE-006 12-QHP-5050- VT / VT-08-045 / Reject 707060 1-GSI-L-53 Pipe Support Component F1.20WB NDP Note 3 GSI B-33 4/23/2008 NDE-006 Nt 707080 1 -GSI-R-54 Pipe Support Component F,:2....... 12-QHP-5050-NDE-006 VT / VT-08-046 / Accept GSI B-33 4/23/2008 11

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam No. Comp. ID Comoonent Descriotion Item Procedure Method/Reo~ort/ResulIts Svstem Dwa/ISO Date 707370 1-GSI-R-45 Pipe Support Component F1.20A 12-QHP-5050- VT / VT-08-047 / Accept GSI B-34 4/23/2008 NDE-006 707390 1-GSI-L-46 Pipe Support Component F1.2013

  • .. .... 12-QHP-5050-NDE-006 VT / VT-08-048 / Accept GSI B-34 4/23/2008 707420 1-GSI-L-47A Pipe Restraint Component F1.20WA 12-QHP-5050- VT VT-08-040 Reject GSI B-34 4/9/2008 12-QHP-5050- V T0-4 cet GI B3 /320 707450 1-GSI-L-48 Pipe Support Component F1.20A NDE-006 VT VT-08-049 Accept GSI B-34 4/23/2008 719030 1-GCTS-R-18 Pipe Support Components F1.20A 12-QHP'5050- VT / VT-08-024 / Accept GCTS B-43 3/4/2008 NDE-006 719840 1-GCTS-R-25 Pipe Support Components F1.20WA NDE-006 VT / VT-08-025 / Accept GCTS B-46 3/4/2008 720390 1-GCTS-L-56 Pipe Support Components F1.20A 12-QHP-5050- VT / VT-08-038 / Accept GCTS B-47 4/9/2008 NDE-006 726600 1-AFW-S4028 Pipe Restraint Component F1.20WS 12-QHP-5050- VT / VT-08-034 / Accept AFW B-52 4/3/2008 NDE-006 726940 1-GFW-L-805 Pipe Support Components F1.20A 12-QHP-5050- VT / VT-08-008 / Accept GFW B-57 2/13/2008 NDE-006 740010 1-GSI-R-89 Pipe Support Components F1.20A 12-QHP-5050- VT / VT-08-006 / Accept GSI B-77 2/13/2008 741120 1-GSI-R-809 Pipe Support Components F1.20WB 1 -QH-0506 VT / VT-08-007 / Accept GSI B-80 2/13/2008 NDE-006 12-QHP-5050- V T0-1 cet GS B8 /820 744510 1-GCS-L-233 Pipe Support Components F1.2013 NDE-006 VT/T0812/Acp GCB-9 /8208 745030 1-GCS-R-90 Pipe Support Components F1.20WA 12-QHP-5050- VT / VT-08-010 / Accept GCS B-90 2/18/2008 NDE-006 7445070 1-GCS-R-93 Pipe Support Components F1.20WC 12-QHP-5050- VT / VT-08-011 / Accept GCS B-90 2/18/2008 NDE-006 NDE-006 745520 1-GCS-R-111 Pipe Support Components F1.20WA 12-QHP-5050- VT / VT-08-014 / Accept GCS B-91 2/25/2008 745070 1GCS-R-93Support omponent F1.2OWC 12-QHP-5050- VTT-801/cet CSB9 21/08 745540 1-GCS-R-1 13

__________NDE-006 Pipe Support Components F1.20WA 12-QHP-5050- VT / VT-08-015 / Accept GCS B-91 2/25/2008 Class 3 Category F-A Heat Exchanger F140 12-QHP-5050- VT / VT-08-022 / Accept CTSHEX B-7 3/4/2008 7941 LE-CTHE IS- Support~opnn I 14 NDE-006II18 12

Inservice Inspection Report Interval 3 / Period 3 / Outage 1 Summary Exam No. ComD. ID Component Description Item Procedure Method/Reoort/Results System Dwa/ISO Date 798800 E-CTSHEX-UL- Upper Lateral Support F1 .40 12-QHP-5050- VT / VT-08-023 / Accept CTSHEX B-7 3/4/2008 SC NDE-006 _________

799000 E-RHRHEX-UL- Upper Lateral Support Fl.40 12-QHP-5050- VT VT-08-020 / Accept RHRHEX 12- 2/27/2008 SC NDE-006 3944C-3 805020 1-GCCW-R-14 Pipe Support Component F1.30A 12-QHP-5050- VT VT-08-009 / Accept GCCW 1-CCW-1 2/13/2008 NDE-006 807860 1-GCCW-R-649 Pipe Support Component F1.30A 12-QHP-5050- VT VT-08-027 / Accept GCCW 8-GCCW-3/31/2008

__________NDE-006 98 831100 1-GESW-V-58 Pipe Support Component Fl.3OWC 12-QHP-5050- VT / VT-08-016 / Accept GESW 1-ESW-27 2/25/2008 NDE-006 832220 1-GESW-R-32 Pipe Support Component F1.30A 12-QHP-5050- VT / VT-08-013 / Accept GESW 1-ESW-46 2/18/2008 NDE-006 832400 1-GESW-L-1 14 Pipe Support Component F1.3013 12-QHP-5050- VT / VT-08-017 / Accept GESW 1-ESW-51 2/25/2008 8340_1GEWL-14 Pieupotomonn F3NDE-006 853170 1-GFW-L-8 Pipe Support Component F1.30WB 12-QHP-5050- VT / VT-08-002 / Accept GFW 1-FW-34 2/11/2008 NDE-006 853430 1-GFW-L-151 Pipe Support Component F1.30WB 12-QHP-5050- VT / VT-08-003 / Accept GFW 1-FW-36 2/11/2008 NDE-006 853610 1-GFW-L-187 Pipe Support Component F1.30WB 12-QHP-5050- VT / VT-08-004 / Accept GFW 1-FW-46 2/11/2008 NDE-006 12-QHP5050-1-AFW-853960 1-AFW-L-912 Pipe Support Component F1.30B 12-QHP50506 VT / VT-08-001 / Accept AFW 86, SH. 2 2/11/2008 NDE-006 OF 2 12-GSF-R-57 Pipe Support Component F1.30A 12-QHP-5050- VT / VT-08-021 / Accept GSF 12-SF-1 2/27/2008 L87_0000 12-GSF-R-57_ PipeSupportComponent F1.30A NDE-006 Note 1: Support 1-GSI-V-608 was evaluated as acceptable by evaluation NCE 00829244-01 Note 2: Support 1-GSI-L-47A was corrected under WO 55317177-01 and sample expansion under WO 55317451 Note 3: Support 1-GSI-L-53 was corrected under WO 55317887-01 and second sample expansion under WO 55317451 and WO 55317932 (Unit 2 for Extent of Condition) 13

Reactor Vessel Bottom Mounted Instrumentation Bare Metal Visual Examination Results.

Bare-metal visual inspection of the CNP Unit 1 reactor pressure vessel (RPV) bottom-mounted instrumentation (BMI) nozzle penetrations was required during the Unit 1 Cycle 22 outage per a regulatory commitment made in a letter from I&M to the NRC, AEP:NRC:3054-14, dated September 17, 2003. The inspection report should include:

1. a summary of the inspections performed,
2. the extent of the inspections,
3. the methods used,
4. a description of the as-found condition of the lower head,
5. any findings of relevant indications of through-wall leakage, and
6. a summary of the disposition of any findings of boric acid deposits and any corrective actions taken as a result of indications found.

Bare-metal visual inspection of the CNP Unit 1 RPV BMI nozzle penetrations was completed during the Unit 1 Cycle 22 refueling outage. This inspection was completed in accordance with I&M's commitment made in response to NRC Bulletin 2003-02, "Leakage from Reactor Pressure Vessel Lower Head Penetrations and Reactor Coolant Pressure Boundary Integrity," dated August 21, 2003.

The inspection was conducted by contractor and CNP personnel in conjunction with Performance Verification personnel qualified as Level 2 examiners. A pole mounted, AC powered camera was used to perform remote VT-2 examination to VT-3 examination criteria on all 58 Unit 1 RPV BMI nozzle penetrations, including 360 degrees around each BMI penetration. No boric acid deposits were found at any RPV BMI nozzle penetration or anywhere on the RPV bottom head surface area. No boric acid residue sampling or analysis was required or performed. The as-found condition of the Unit 1 RPV bottom head was identical to the as-left condition following the inspection performed during the Unit 1 Cycle 21 refueling outage. No indications of through-wall leakage were found during the Unit 1 Cycle 22 RPV BMI inspection. The bottom two sections of insulation were lowered to allow unobstructed access to all penetrations and the membrane areas of the lower reactor vessel. The inspection results were digitally recorded, and copies of the video files were saved to computer drives as video clips.

Both hard copy examination results based upon approved procedures and optical records (i.e., digital video) have been documented. Work Order Task 55287594-04 documents the results of this examination.

14

ABSTRACT OF SYSTEM PRESSURE TESTS INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR.PLANT, UNIT I BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 4 Inservice Inspection System Pressure Tests were performed during the period November 14, 2006, to April 29, 2008. These tests were performed in accordance with the requirements of ASME Section XI, 1989 (no Addenda) and 1992 Editions with 1992 Addenda, Articles IWA-5000, IWB-5000, IWC-5000, IWD-5000, Code Case N-416-1, Code Case N-533, Code Case N-498-1 and N-616, as applicable.

Pressure tests for portions of systems identified below were performed during the Unit 1 Cycle 22 refueling outage. The remainder of the pressure tests for the period were performed in conjunction with functional tests, inservice operation, and special procedures, as applicable. No pressure boundary through-wall leaks were identified.

Completion JO Activity Test Description Date 55269881 01 East Train CCW System 08/06/2007 55269881 02 West Train CCW System 08/09/2007 55269881 04 Misc CCW Supply/Return Headers 08/24/2007 55269881 05 Spare COW Pump 05/22/2007 55238598 01 East Train ESW System, AB EDG 11/15/2007 55238598 02 West Train ESW System, CD EDG 12/13/2007 55248520 01 Accumuiator Discarge Piping 04/29/2008 55248520 05 CCW Exc Letdown, RCP Therm Barr, Oil Coolers 04/29/2008 55248520 06 CST and RWST, CTS, RHR, SIS, AFW Systems 01/14/2008 55248520 07 Main Steam, Feedwater, CVCS Systems 02/21/2008 55248520 08 East Train RHR 04/23/2008 55248520 09 West Train RHR 04/22/2008 55248520 10 Feedwater, Main Steam and Steam Generators 04/29/2008 55248520 16 Excess Letdown Hx, Seal Injection 04/29/2008 55248520 26 Pressurizer Steam Space 04/29/2008 55248520 32 Loop 1 & 3 Hot Leg Sample 04/29/2008 55248520 34 Pressurizer Liquid Space 04/29/2008 55248520 77 1-TK-84, 1-TK-85 04/21/2008 55248520 78 RHR Misc Piping (east train) 04/22/2008 55248520 79 RHR Misc Piping (west train) 04/22/2008 55248520 80 RHR to RCS Boundary 04/23/2008 55293871 01 RCS NOP/NOT 04/29/2008 15

ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 5 ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS Snubber examinations and functional testing were performed in conjunction with the maintenance procedures implemented to satisfy technical specification surveillance requirements. Provided is a summary of the as-found visual examinations and as-found functional test results.

Snubber VT-3 Visual Examinations Snubber No. ]F Exam Date Work Order No. Results 1-GRC-S519 3/28/08 55292558-01 Acceptable 1-GRC-S587 3/28/08 55292558-01 Acceptable 1-GRC-S592 3/28/08 55292558-01 Acceptable 1-GRC-$594 3/28/08 55292558-01 Acceptable 1-GRC-$596 3/28/08 ' 55292558-01 Acceptable 1-GRC-$598 4/16/0.8 55292558-01 Acceptable 1-GRC-$599 3/28/08 55292558-01 Acceptable 1-GRC-S604 3/28/08 55292558-01 Acceptable 1-GRC-S608 4/15/08 55292558-01 Acceptable 1-GRC-S614 3/28/08 55292558-01 Acceptable 1-AFW-S4023 4/8/08 55292559-01 Acceptable 1-AFW-S4024-L 4/8/08 55292559-01 Acceptable 1-AFW-S4024-U 4/8/08 55292559-01 Acceptable 1-AFW-S4021 4/8/08 55292559-01 Acceptable 1-AFW-S4028-L 4/8/08 55292559-01 Acceptable 1-AFW-S4028-U 4/8/08 55292559-01 Acceptable 1-AFW-S4027 4/15/08 55292559-01 Acceptable 1-AFW-S4025 4/15/08 55292559-01 Acceptable 1-AFW-S4031 4/8/08 55292559-01 Acceptable 1-AFW-S4032-L 4/8/08 55292559-01 Acceptable 1-AFW-S4032-U 4/8/08 55292559-01 Acceptable 1-AFW-S4029 4/8/08 55292559-01 Acceptable 1-AFW-S4025 4/15/08 55292559-01 Acceptable 1-AFW-S4036-L 4/8/08 55292559-01 Acceptable 1-AFW-S4036-U 4/8/08 55292559-01 Acceptable 1-AFW-S4035 4/8/08 55292559-01 Acceptable 1-AFW-S4033 4/15/08 55292559-01 Acceptable 1-GCCW-S309 12/27/08 55289164-01 Acceptable I-GCCW-S837 12/27/08 55289164-01 Acceptable 16

ABSTRACT OF SNUBBER EXAMINATION AND TEST RESULTS 1-GCCW-S838 12/27/08 55289164-01 Acceptable 12-GCCW-S839 12/27/08 55289164-01 Acceptable Snubber VT-3 Visual Examinations (continued)

Snubber No. Exam Date Job Order No. Results 1-GBD-S573 3/31/08 55292560-01 Acceptable 1-GBD-S574 3/31/08 55292560-01 Acceptable 1-OME-3-1-HSD-3U 3/30/08 55292557-01 Acceptable 1-OME-3-1 -HSD-3L 3/30/08 55292557-01 Acceptable 1-OME-3-1-HSD-1U 3/30/08 55292557-01 Acceptable 1-OME-3-1-HSD- 1L 3/30/08 55292557-01 Acceptable 1-OME-3-2-HSD-3U 3/30/08 55292557-01 Acceptable 1 -OME-3-2-HSD-3L 3/30/08 55292557-01 Acceptable 1-OME-3-2-HSD- 1U 3/30/08 55292557-01 Acceptable 1-OME-3-2-HSD-1L 3/30/08 55292557-01 Acceptable 1-OME-3-3-HSD-3U 3/30/08 55292557701 Acceptable 1-OME-3-3-HSD-3L 3/30/08 55292557-01 Acceptable 1-OME-3-3-HSD-1U 3/30/08 55292557-01 Acceptable 1 -OME-3-3-HSD- 1L 3/30/08 55292557-01 Acceptable 1-OME-3-4-HSD-3U 3/30/08 55292557-01 Acceptable 1 -OME-3-4-HSD-3L 3/30/08 55292557-01 Acceptable 1-OME-3-4-HSD- 1U 3/30/08 55292557-01 Acceptable 1 -OME-3-4-HSD- 1L 3/30/08 - 55292557-01 Acceptable Snubber Fu'nctional Tests Snubber No. Test Date Work Order No. Results Remarks 1-AFW-S4029 4/9/08 55273419-01 Acceptable Small Bore Grinnell l-AFW-S4033 4/9/08 55271823-01 Acceptable Small Bore Grinnell 12-GCCW-S839 3/26/08 55269608-01 Acceptable Small Bore Grinnell 1-GRC-S599 4/13/08 55269613-01 Acceptable Small Bore Grinnell 1-GBD-S573 4/9/08 55270359-01 Acceptable Small Bore Grinnell 1-OME-3-2-HSD-1L 4/5/08 55273035-02 Acceptable Large Bore 1-OME-3-2-HSD-1U 4/5/08 55273037-02 Acceptable Large Bore 1-OME-3-2-HSD-3L 4/5/08 55272854-02 Acceptable Large Bore 1-OME-3-2-HSD-3U 4/5/08 55273036-02 Acceptable Large Bore The minimum 14% Technical Requirements Manual required sample size consists of 5 small bore (Grinnell) and 3 large bore (Steam Generator) snubbers.

17

ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR ASME SECTION XI SUBSECTIONS IWE AND IWL INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN,MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 6 CONTAINMENT INSERVICE INSPECTIONS During the reporting period of November 14, 2006, to April 29, 2008, inservice inspections were performed on the Unit 1 containment pressure retaining structure in accordance with Subsections IWE and IWL of ASME Section XI, 1992 Edition and 1992 Addenda, and 10 CFR 50.55a.

The following attachment provides a listing of the Subsection IWE examinations performed, results, and corrective actions, if any were performed, on Class MC components and the Class CC liner. The examination results were compared to established acceptance criteria. All results were within the established acceptance criteria. There were no areas that were required to be classified as an Augmented Examination area in accordance with IWE-1240.

Containment concrete examinations were completed under Work Order No. 55243961 and a final report was issued under Document No. SD-070718-001, Revision 0. No degradation has been found that impacts the structural integrity of the containment concrete. There were no conditions noted in accessible areas that could indicate the presence of, or result in, degradation to inaccessible areas. .

18

ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR ASME SECTION XI SUBSECTIONS IWE AND IWL rirUr LU UrdL;U piUparU~daLu ad[IU uudLily.

penetration 1-CPN-4, at liner to penetration 55232268-4/3/2008 1 02 interface 4" away from penetration on liner and VT-3 None Accept from liner out on penetration to radius of penetration.

i Liner plate surfaces behind the Ice Condenser Divider Barrier Seal when removed: ZONE 1-612-3, at Elevation 638' near Column 3. Gap at this location is .25 inches wide by 12 inches long. Viewable area starts approximately 8 No evidence of degradation that inches up from seal attachment to liner plate, 55293075- General may affect either containment 4/7/2008 1 04 up approximately 3 feet and 1 foot to either Visual structural integrity or leak Accept side. Zone 1-612-6, at Elevation 638'.between tightness.

Column 17 and end wall, at Column 17. Gap at this location is .75 inches wide by 12 inches long. Viewable area starts from divider barrier steel attachment up approximately 3 feet and 1 foot to either side.

4/8/2008 1 55240765- 1-CPN-83-BOLTING Penetration Bolting VT-1 None Accept 4/9/2008 1 55309441- Elevation 612 Airlock Boltihg: 1ILPLODV- VT-i VT- 1OTN3 None None*: Accept Accept 01 BOLTING Elevation 612 Airlock Bolting: 1-LPLIDE-55240765- BOLTING, 1-LPLODE-BOLTING. Elevation 4/10/2008 01 650 Airlock Bolting: 1-UPLODH-BOLTING, 1- VT-1 None Accept UPLIDH-BOLTING, 1-UPLODE-BOLTING, 1-UPLIDE-BOLTING.

Prior to surface preparation and coating: . Peeling paint, delamination of 4/11/2008 55294146- Surfaces on the Equipment Hatch and VT-3 top coat. No evidence of Accept 06 Elevation 650 Airlock Barrel, surfaces of discoloration or rusting, or signs interior core barrel and airlock, of distress.

4/11/2008 1 55240765- Elevation 650 Airlock Bolting: 1-UPLODB- VT-i None Accept 01 BOLTING (32 bolts, nuts, washers) VT-1 NoneAccept 19

ABSTRACT OF EXAMINATIONS, RESULTS, AND CORRECTIVE ACTIONS FOR STEAM GENERATOR EDDY CURRENT EXAMINATIONS INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 7 The Unit 1 steam generator inspection results are submitted as a separate report to the NRC in accordance with Technical Specifications. No steam generator tube examinations were performed this outage.

20

NIS-2 REPAIR AND REPLACEMENT REPORTS INDEX INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 8 NIS-2 REPAIR AND REPLACEMENT REPORTS INDEX 21

NIS-2 REPAIR AND REPLACEMENT REPORTS INDEX U1C22 Class 1 and 2 Repair and Replacement Reports Index Work Order Description Component Code Class 55230883-01 REPLACED SAFETY VALVE 1-SV-104W 2 55247730-01/09 REPLACED VALVE IADD LOOP SEAL 1-NRV-151 1 55247730-02 REPLACED VALVE / ADD LOOP SEAL 1-NRV-152 1 55247730-03 REPLACED VALVE / ADD LOOP SEAL 1-NRV-153 1 55250094-01 REPLACED VALVE INTERNALS 1-CS-536 2 55253343-02 REPLACED VALVE IPIPING 1-MS-135-1 2 55270359-01 REPLACED SNUBBER AND LOAD PIN 1-GBD-S573 2 55271823-01 REPLACED SNUBBER 1-AFW-S4033 2 55273419-01 REPLACED SNUBBER 1-AFW-S4029 2 55281975-01 ADDED PLATE AND PIPE 1-TK-33 2 55288542-01 REPLACED VALVE INTERNALS 1-MRV-221 2 55288822-01 REPLACED MECHANICAL SEAL GLAND PLATES 1-PP-50E 2 55290281-05 REPLACED SAFETY-VALVE 1-SV-45A. 1 REPLACED MANWAY BOLT - The NIS-2 Report is to be 55291871-07 provided in a subsequent submittal due to a missed preservice 1-TK-11 2 examination. See Condition Report AR00832956.

55291872-01 REPLACED VALVE INTERNALS 1-CTS-124E 2 55292537-08 REPLACE PIPING 1-MS-543-L1.8 2 55294264-01 REPLACED BRACKET AND LOAD PIN 1-AFW-S4023 2 55294293-05 REPLACED SAFETY VALVE 1-SV-45B 1 55294294-05 REPLACED SAFETY VALVE 1-SV-45C I 55294550-01 REPLACED SAFETY VALVE 1-SV-104E 2 55303819-02 INSTALL FLANGE AND PIPING 1-TK-33 2 1-RH-128E 55305753-14/15 SWAP OF VALVE INTERNALS/BONNETS 1-RMO-314 2 55305753-17 REPLACED VALVE / PIPING 1-RH-164E 2 55305754-15 SWAP OF VALVE INTERNALS/BONNETS 1-RH-128W 2 1-IMO-324 2 55313439-05 REPLACE SUPPORT ITEMS 1-GRC-R-603 1 55316254-02/09 REPLACE SECONDARY MANWAY BOLTING 1-OME-3-3 2 55316254-10 INSTALL SECONDARY MANWAY HELICOIL 1-OME-3-3 2 55316901-01/13 REPLACE VALVE INTERNALS 1-ICM-265 2 55317435-02 REPLACE SUPPORT ITEMS 1-GRH-R-508 2.

55317887-01 REPLACE SUPPORT ITEMS 1-GSI-L-53 2 55318117-04 WELD OVERLAY REPAIR 1-NFP-222-V2 1 22

NIS-2 REPAIR AND REPLACEMENT REPORTS INDEX INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT, UNIT 1 BRIDGMAN, MI COMMERCIAL SERVICE DATE 8-23-1975 SECTION 9 NIS-2 REPAIR AND REPLACEMENT REPORTS 23

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/13/2008 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-SV-104W Name One Cook Place, Bridagman, M1 49106 JOB ORDER No. 55230883-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, Ml 49106 Expiration Date N/A Address
4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 No Addenda 6,. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-SV-104W SAFETY CROSBY Cat-ID NA MODEL # N/A REPLACED NO VALVE 0430036394 JB25-3-TD-SPL UTC-0001317091 TYPE - E SERIAL #

N69972-00-0014

7. Description of Work REPLACED SAFETY VALVE
8. Test Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure I Other -- Pressure N/A psi. Test Temp. N/A F e7> '

p.

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55230883-01

9. Remarks: VT-2 Performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type'Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phi Rh e roaram Aministrator Date , May 19 2008 Owner or Owner's Designee,. Title Reviewed by dp".i--s A. / Q4Lý (1 Date A oZ )/' ,20 0, Engineering lOrodrams, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board~of Boilerand Pressure Vessel Inspectors and the State or Province of Michiqan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period -/. -- '-on 9 to Lf - 3 a - z0o ' ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,"7.L ( L..Q' /f1e.-- .£ "'.Ic Commissions: NB11412ANI, Mi. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 5-7-.7 20.9'o

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/10/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet t of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-NRV-151 Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No 55247730-01 /09 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A OnA_ fnnk PlinP_ Rridnm~n MI 4Q106 Ml 49106 Expiration Date N/A One Cook Place Bridnman Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N 416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-NRV-151 VALVE MASONNEILAN 'Cat ID N/A Model # N/A REPLACED NO GLOBE 0430042110 38-20771 2"X 3" UTC-1318446 A351 CF8M PIPE N/A Cat ID n/a ASME SA376, N/A REPLACED NO 3" 0497001333 TP-316 PIPE ELBOW N/A Cat ID N/A ASME SA-403, N/A REPLACED NO 3" 900 0430015931 GRWP-S 316 PIPE ELBOW N/A Cat ID n/a ASME SA-403, N/A REPLACED NO 3" 450 0430019696 GR WP-S 316
7. Description of Work REPLACE VALVE AND ADD LOOP SEAL TO SYSTEM
8. Test Conducted: Hydrostatic 0 Pneumatic F]Nominal Operating Pressure Other F-I Pressure. N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55247730-01 / 09

9. Remarks' Fit-up/Final VT/PT plus RT, VT-2 System Leakage Test per Code Case N 416-1.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Siel im Administrator Date May 15 , 2008 Owner or Owner's Designee, Title Reviewed by -/A/" /1. 67ýýkj / 9; /"i , Date dur /3" ,20 6*?

Engineering Prodrams CERTIFICAtE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period e-f- /- zo.o to ZY.. - Z 0o ,' and state that to the best of my knowledge and belief, the Owner has performed examinationsand taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor-his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date G ~-3, 20 'C'

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/16/2008 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit I Component 1-NRV-152 Name One Cook Place. Bridaman. Ml 49106 JOB ORDER No. 55247730-02 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridciman, Ml 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-NRV-152 VALVE GLOBE MASONNEILAN Cat. ID N/A Model # N/A REPLACED NO 2" X 3" 0430042110 38-20771 1500# UTC-1318446 ASTM A351 CF8M PIPE N/A Cat. ID N/A ASME-SA376 N/A REPLACED NO 3" S.S. 0497001333 TP-316 UTC-1 313449 PIPE N/A Cat. ID N/A ASME-SA403 N/A REPLACED NO ELBOW 3" 0430019696 GR-WP-S316 450 UTC-1295337 PIPE N/A Cat. ID N/A ASME-SA403 N/A REPLACED NO ELBOW 3" 0430015931 GR-WP-S316 900 UTC-1294644
7. Description of Work INSTALL LOOP SEALS ASSOCIATED PIPING
8. Test Conducted: Hydrostatic El Pneumatic ENominal Operating Pressure I Other El . Pressure N/A psi. Test Temp. N/A F tL-S

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55247730-02

9. Remarks: 3" piping fit-up / final VT/PT AND RT. VT-2 Leakage test per Code Case N-416-1 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Philip e M* d ia dministrator Date May 15 ,2008 Owner or Owner's Designee, Title ReviewedEby /Mwg P' 20 Engineerir~g IPfograms CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectdrs and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 4-/! - 2_-oo to /- '7- z.2oý , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • -e* i1. -C"..e,c /77-*&C -6'Commissions:

U NB11412ANI. Mi. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 6 ' 20 0 g6

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/09/08 Name P.O. Box 60 Fort Wavne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-NRV-153 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55247730-03 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N 416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-NRV-153 VALVE MASONNEILAN Cat ID N/A Model # N/A REPLACED NO GLOBE 0430042110 38-20771 2" X 3" UTC-1318447 A351 CF8M PIPE N/A Cat ID n/a ASME SA376, N/A REPLACED NO 3" 0497001333 TP-316 PIPE ELBOW N/A Cat ID N/A ASME SA-403, N/A REPLACED NO 3" 900 0430015931 GR WP-S 316 PIPE ELBOW N/A Cat ID n/a ASME SA-403, N/A REPLACED NO 3" 450 0430019696 GR WP-S 316
7. Description of Work REPLACE VALVE AND ADD LOOP SEAL TO SYSTEM
8. Test Conducted: Hydrostatic -- Pneumatic F- Nominal Operating Pressure I-Other F__ Pressure N/A psi. Test Temp. N/A F I.e

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55247730-03

9. Remarks: Fit-up/Final VT/PT plus RT, VT-2System Leakage Test per Code Case N 416-1.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Sig Phh4i0Rl e ldinciProoram Administrator Date May 15 , 2008 Owner or Owner's Designee, Title Reviewed by-,/1A*L*Ui,-ii.e./ Ai. 9A- /l1" Date JUc4i6 /3 , 204 Engineering'Pre rams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors-and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I. Reuel K. Schenck have inspected the components described in this Owner's Report during the period L-.-, - Zoo 0 to /--) -IV- 7-00 5' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1-iZe-,te-li H-LA , -- 41119 Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date &*--1 20 0 (

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/10/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-CS-536 Name One Cook Place, Bridcqman, MI 49106 JOB ORDER No. 55250094-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: CHEMICAL VOLUME & CONTROL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ASME Sec. Il1 1986 Add. N/A Code Case N/A (b) Applicable Edition.of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-CS-536 BALL VALVE BNLI Cat ID N/A 1-FCN-622-RO-14 N/A REPLACE NO ASSEMBLY 0430033374
7. Description of Work REPLACE VALVE INTERNALS
8. Test Conducted: Hydrostatic 11 Pneumatic F-1 Nominal Operating Pressure[J Other 0-- 'Pressure N/A psi. Test Temp. N/A F

[INT-_2%__

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55250094-01

9. Remarks: VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phi fiew Q p#ýý!n-mro dministrator Date May 15 ,2008__

Owner or Owner's Designee, Title Reviewed by JAJZS /41. n20 Date ;UeC 2r 6Y Engineering f'rogramis CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period I-/-I- "Z.Oo S to i- t-2.0 ro _, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- . e , Commissions: NB++3,4AN4-MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 6--3 20 tD

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/16/2008 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-MS-135-1

. Name One Cook Place., Bridgman, MI 49106 JOB ORDER No. 55253343-02 Address Repair Org. P.O. No., Job No., etc

3. Work Performed by AEP/D.C. COOK Maint Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. M1 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-MS- 135-1 GATE HANCOCK Cat-ID NA Model # N/A REPLACED NO VALVE 0430037420 950W UTC-0001318824 SA-105 2" CLASS 800 PIPE N/A Cat-ID N/A ASME N/A REPLACED NO 2" Sch 80 0430014981 SA-106 GR-B UTC-0001312399
7. Description of Work REPLACED VALVE AND PIPING
8. Test Conducted: Hydrostatic D Pneumatic - ] Nominal Operating Pressure Other D" Pressure N/A _psi. Test Temp. N/A F

<14-S

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55253343-02

9. Remarks: VT-2 Performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this. REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Sig ned ilR Uin Pioqram Administrator Date May 19 2008 Owner or Owner's Designee, Title Reviewed by 4

,_ /A/). 9 L

/ii. c9L)Z/6 Date 11M Y lo ,20

Engineerind Pr*grams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I. Reuel K. Schenck have inspected the components described in this Owner's Report during the period q-// -7oo 0 to L./- 3 o oe 0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

VL, Sc.ke*-^ /Tt.f \-L$' Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date ,. -17 20O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/09/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1_, Component 1-GBD-S573 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55270359-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: BLOWDOWN SYSTEM ISI 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or-Replacement Stamped ASP, PO) (Yes or No) 1-GBD-S573 SNUBBER GRINNELL Cat-ID N/A Model # N/A REPLACE NO CONFIG -A 0430024691 200N-1.5X5 UTC-1296057 SN-33378 PIN N/A Cat-ID N/A TAPERED N/A REPLACE NO 0430024975 LOAD UTC-1296118 3/4" NOM
7. Description of Work REPLACE SNUBBER AND COMPONENTS
8. Test Conducted: Hydrostatic F-' Pneumatic Fý Nominal Operating PressureE Other El __Pressure N/A psi. Test Temp. N/A F tc..S

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55270359-01

9. Remarks: VT-3 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed P1RIew;eldeI 6Pr Administrator Date May 15 ,2008.

Owner or Owner's Designee, Title Reviewed by 'J/A,6 /1. fi-rJc/t~a 1 , PA c ( Date *Jcj. /9 ,20 0,?

Engineeririg Pr6grams CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period -I -Zo *

- to ty / 2-2o0 5' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

`ReiŽce- I Lc-. SJ-,.C^ Lt, omsin:NI1IAIM.305 Commissions: NB11412ANI, Mi. 300959 Inspectors Signature National Board, State, Province, and Endorsements Date 20 0E8

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/09108 Name P.O. Box60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-AFW-S4033 Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. 55271823-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. NIA One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: FEEDWATER SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1. 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-AFW-S4033 SNUBBER GRINNELL Cat ID# N/A Model # N/A REPLACED NO 0430024700 200/201 N2.5X5 UTC-0001319046 Serial # 36969
7. Description of Work REPLACE SNUBBER
8. Test Conducted: Hydrostatic 1: Pneumatic D Nominal Operating Pressure D Other E- ._Pressure N/A psi. Test Temp. N/A F fIdII-- .

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 55271823-01

9. Remarks: VT-3 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phirt- Date May 15 ,2008.

Owner or Owner's Designee, Title Reviewedby Engineering IP/rojams Jii. Date I__*' -o ;20 O-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period LI- q- 2-o 6 to .1-3o- ?_oo8 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-Commissions: NB149A-,,-NI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 5-.?_Z_7200B

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/09/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit .l.j_ Component 1-AFW-S4029 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55273419-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Pl~ic Rridnm~n. M1 491O6 IVII 49106 Expiration Date N/A One Cook Place Bridnman Address
4. Identification of System: FEEDWATER SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI-B31.1 - 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)

I -AFW-S4029 SNUBBER GRINNELL Cat ID N/A S/N N/A REPLACE NO 0430024683 32548 UTC 0001309814

+ I t -t I t -t

7. Description of Work REPLACE EXISTING SNUBBER WITH NEW SNUBBER
8. Test Conducted: Hydrostatic D Pneumatic E Nominal Operating Pressure D1 Other Pressure N/A psi. Test Temp. N/A F INIT

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55273419-01

9. Remarks: VT-3 Performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Philli Pro amAdministrator Date May 15 2008 Owner or Owner's Designee, Title Reviewed by Jam-S /.. (7ii*JA - 2&-ta Date /1 "1#04 2 20 O "

Engineeridg FPograms CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company. of Boston MA. 02108. I, Reuel K Schenck have inspected the components described in this Owner's Report during the period '-/- q- .aoo to - 7.o0o ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

e a A v-srýeC*A*-

X.. .ek /* .%. Commissions: NB11412ANI, Mi. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date -5 7 - 2009

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 11117/06 Name P.O. Box 60 Fort Wavne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-TK-33 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55281975-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, Ml 49106 Expiration Date NIA Address
4. Identification of System: CONTAINMENT SPRAY SYSTEM ISI CLASS 22 ISI CLASS
5. (a) Applicable Const. Code ANSI-B3,1.1 - 1983 Add. N/A Code Case NIA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-TK-33

/4 PLATE N/A Cat ID N/A ASTM A240 N/A Replacement NO 0430153223 1990 UTC 1305023 10" PIPE N/A Cat ID N/A ASME SA312 N/A Replacement- NO 0497000589 .TP 304

_UTC 1310648

7. Description of Work ADDED PLATE AND PIPE
8. Test Conducted: Hydrostatic 13 Pneumatik j-" Nominal Operating Pressure l Other [-] PT Pressure psi. Test Temp. _ F INiTA

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 55281975-01

9. Remarks: PT performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Date ,20497 Reviewed by J/IMt6 Al.

M*6f-.,ut/0 A 92ýL/ Date JLL ,20 6-7 Engineefinl'Programs CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board.of Boiler and Pressure Vessel Inspectors and the State or Province of - MichicQan and employed by ABS GROUP INC. 16855 Northchase Drive of HOUSTON, TEXAS 77060-6008. I. James Loncienberger have inspected the components described in this Owner's Report during the period Agr it 4. to 1 AW C. 2el, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____________________ Commissions: VBIWt. 3apr . Arr 6*pector's7Signr4ture National Board, State, Province, and Endorsements Date J,."2007 ABS INC

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/15/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-MRV-221 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55288542-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM IS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-MRV-221 VALVE FISHER Cat-ID N/A 2" 600# N/A REPLACE NO STEM & PLUG 04300688864 TYPE- EAS ASSEMBLY VALVE
7. Description of Work REPLACE VALVE INTERNALS
8. Test Conducted: Hydrostatics-1 Pneumatic ] Nominal Operating PressurF-l Other [E N/A psi. Test Temp. N/A F <1

__I___________Pressure 1*'1Z11-1 I

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55288542-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed hjllip' Rhv (e P ram Administrator Date May 15 2008 Owner or Owner's Designee, Title Reviewed by -'%.'ýt/11.. *1i*!/ -,,4,-. fl.r2L Date Jui',/ =3 ,20 0,R Engin 96 rir6 Programs

, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K.' Schenck have inspected the components described in this Owner's Report during the period q.- /- 2.0 o to e

- /1- -2 a, ? and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

%-Z.LL*C1 1:. .*i-t-

-CknC" '" / Commissions: NB11412ANI, Mi. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date (,4 j 20 o

FORM NIS-2AsOWNER'SRequired REPORT FOR REPAIRS OR REPLACEMENTS by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/12/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-PP-50E Name One Cook Place, Bridgiman, M1 49106 JOB ORDER No. 55288822-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEPID.C. COOK Maint Department Type Code Symbol Stamp N/A Name Authorization No. N/A OnA (ook Place Rridmrnan Ml 491fl MI 49106 Expiration Date N/A One Conk Place Bridnman Address
4. Identification of System: CHEMICAL VOLUME & CONTROL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code A.SME DRAFT CODE. 1968. PN Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-PP-50E MECH SEAL FLOWSERVE Cat ID N/A BOM # N/A REPLACE NO DISCHARGE 0430015098 426224N-QI MECH SEAL FLOWSERVE Cat ID N/A BOM # N/A REPLACE NO SUCTION 0430015099 426328N-Q1
7. Description of Work REPLACE DISCHARGE AND SUCTION MECH SEALS GLAND PLATES
8. Test Conducted: Hydrostatic Dý Pneumatic '] Nominal Operating Pressure Other r Pressure N/A _psi. Test Temp. N/A F INIT I ZE-S

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 55288822-01

9. Remarks: VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Ph llipUv em Administrator Date May 15 ,2008__

Owner or Owner's Designee, Title Reviewed by /-< M 6-. *fi4. -/ ( L4i Date A/),* 3A ,20 66" Engineeridg I9rograms CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company. of Boston MA. 02108 I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 4-R --2-0 , Z to ,4- ' 3- -zoo V . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer

.shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

. . tF'-f\. t Commissions: NB11412ANI, Mi. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date S.' ) 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Page 1 of 2

1. Owner AMERICAN ELECTRIC POWER . Date 04/19/2008 Name P.O. Box 60 Fort Wayne, IN, 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-SV-45A Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55290281-05 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ASME SEC. III 1968 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-SV-45A SAFETY CROSBY Cat-ID NA Model. # N/A REPLACED NO VALVE 0430036392 6M6-HB-BP-86 UTC-0001317762 TYPE.E Serial. #

56499-00-0001

7. Description of Work REPLACED SAFETY VALVE
8. Test Conducted: Hydrostatic LI] Pneumatic [] Nominal Operating Pressure x-I Other LJ Pressure _ psi. Test Temp. F

'7~L S

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55290281-05

9. Remarks: Pre-service NDE VT-3, VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Ph i eno4 Prooram &m"insrator Date May 15 I2008

. Owner or Owner's besignee, Title Reviewed by JAPIpws's/.A "A*-,/(*,4 /9. c9J.LZ Date / aY o0 ,20 Enginee(inJ Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I. Reuel K. Schenck have inspected the components described in this Owner's Report during the period -I -1 ZO- _ . to -*/ Z2.O o; , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/ .Commissions: NB1.1412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 6 - 3 20 08

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 03/28/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit I Component 1-CTS-124E Name One Cook Place, Bridgman, MI 49106 JOR ORDIER Nin qr9q1R72-7_1 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgqman, Ml 49106 Expiration Date N/A Address
4. Identification of System: CONTAINMENT SPRAY SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add, N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-CTS-124E DISC N/A Cat ID N/A ASTM 351 N/A REPLACE NO 0430033688
7. Description of Work REPLACE VALVE INTERNALS
8. Test Conducted: Hydrostatic F] Pneumatic F Nominal Operating Pressure D Other E----_ Pressure N/A psi. Test Temp. N/A F

-"? tL*-

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55291872-01

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed _ & e .q Program Administrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by . I4Al £4 l. Date AYAV'IV ' 20 6?

Engineering Vrograms CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I. Reuel K. Schenck have inspected the components described in this Owner's Report during the period 3 - L1- 2.. o a .to - 2oo Zo/. 0' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section.XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

e*Z u.e t t,'HI . A ' Commissions: NB44-4,ANI. MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date S- Z- 2 0 o0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

1. Owner AMERICAN ELECTRIC POWER Date 04/20/08 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-MS-543-L1.8 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55292537-08 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridqman, MI 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM SI 3
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-MS-543-L1.8 PIPE 1" N/A Cat-ID N/A SA182, GR 304 N/A REPLACE NO

ý,HALF 0430016958 SW, 3000 #

COUPLING PIPE 4" N/A EXISTING N/A ASME SA376 N/A EXISTING NO Sch. 80 GR. TP316

7. Description of Work REPLACE PIPING COMPONENTS
8. Test Conducted: Hydrostatics Pneumatics- Nominal Operating Pressur---]

Other El Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55292537-08

9. Remarks: Fit-up/Final VT and PT.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed hilli U 07 e Administrator Date May 15 2008 Owner or Owner's Designee, Title Reviewed by V) Ami'-S/l- P c4-,,-/ §,.,,s4 /'. Date Jai, /J" ,20 -"

Engineering'Pro* rams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding avalid commission issued bythe National Board of Boilerand PressureVessel Inspectorsand the State or Province of Michigan and employed by OneCIS Insurance Company " of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period !51- , - Z7-0 o to Z 2.-. oo b1 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1Ze~-..I, . /, i. T

/-q 91...4 Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 6, - 20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/13/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-AFW-S-4023 Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55294264-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Departmen t Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
4. Identification of System: FEEDWATER SYSTEM ISI 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-AFW-S-4023 BRACKET N/A Cat-ID N/A REAR N/A REPLACE NO 0497003250 MOUNTING UTC-1 317833 PIN N/A Cat-ID N/A 1" NOM N/A REPLACE NO 0430024977 TAPERED UTC-1296119 LOAD
7. Description of Work REPLACE SUPPORT BRACKETS AND COMPONENTS
8. Test Conducted: Hydrostatic Pneumatic . FNominal Operating Pressure [*

Other __ Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55294264-01

9. Remark:VT-3 performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phillipo Phew /eldin Proaram Administrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by JEginein- P s Date 20 Engineerin6-Pr~grams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 5-/- - Z. 0 i to ' /5"- Zoo9 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I CLA K. SC-4eAr- f Commissions: NBI 1412ANI. Mi. 300959 Inspectors Signature National Board, State, Province, and Endorsements Date &_-Ko 2000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Page 1 of 2

1. Owner AMERICAN ELECTRIC POWER Date 04/19/2008 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-SV-45B Name One Cook Place, Bridqman, MI 49106 JOB ORDER No. 55294293-05 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ASME SEC. III 1968 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-SV-45B SAFETY CROSBY Cat-ID NA Model # N/A REPLACED NO RELIEF 043*0036392 6M6-HB-BP-86 VALVE UTC-0001317760 TYPE.E Serial #

N56499 0007

7. Description of Work REPLACED SAFETY VALVE
8. Test Conducted: Hydrostatic D PneumaticFl- Nominal Operating Pressure Other--] Pressure psi. Test Temp. F e12-, - S.

Page 2 of 2 NIT~!L FORM NIS-2 (Back)

Job Order/File 55294293-05

9. Remarks: VT-3 performed on internal surfaces; Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phili Pr mn Administrator Date May 19 2008 Owner or Owner's Designee, Title Reviewed by 'J.AMf,-. AM /1- , 5%.*-Z Date /A914-' !o 20 0.P Engineering P/ogfams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued bythe National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 14- I oo n to --- I - Zooa , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7 -Commissions: NB11412ANI,. MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date . 3.. 20 C

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/19/2008 Name P.O. Box60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-SV-45C Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. 55294294-05 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, M1 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ASME Sec. 1111968 N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-SV-45C SAFETY CROSBY Cat-ID NA SN# N/A REPLACED, NO VALVE 0430036392 N56499 UTC-0001310444 0002
7. Description of Work REPLACED SAFETY VALVE
8. Test Conducted: Hydrostatic Pneumatic FINominal Operating Pressure 51-Other Pressure N/A psi. Test Temp. N/A F INlRIT~

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 55294294-05

9. Remarks: VT-2 Performed & VT-3 performed on internal surfaces.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phillip R-w- Date May 19 2008 Owner or Owner's De~ignee, Title Reviewed by, }4A,.iS /41 . F 1"C_.L, / /,I. c ZL Date 11A,', ) ,20 (39 Engineerin! Irograms CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 4/" 9- 2-oOR to L/ 3o-z.0- 68 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 5- 7.1 20 o

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/13/2008 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT unit 1 Component 1-SV-104E Name One Cook Place, Bridgman, MI 49106 JOB ORDER No. 55294550-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989. No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-SV-1 04E VALVE CROSBY Cat-ID NA Model # N/A REPLACED NO SAFETY 0430036394 JB25-3-TD-SPL 2"X3" SERIAL # TYPE E N-69972-00-0018
7. Description of Work REPLACED SAFETY VALVE
8. Test Conducted: Hydrostatic [: Pneumatic 1 Nominal Operating Pressure Other FD_-] Pressure N/A psi. Test Temp. N/A F I'-- "'

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55294550-01

9. Remarks: VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. . N/A Expiration Date N/A Signed Phillip RJlw Proaram Administrator 3Weldinq Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by 40A1Y 4/2, 4iQ4, . Date ,104,1'2 . ,20 6?

Enginee ind'Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period I Z-I-

".oo- 16 to L4/- /R-Z.e~O8' , and state that to the best of my knowledge and belief,- the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I l~f/ z.

Commissions: NB-I44-2ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date £-Z? 20 Q

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 11/09/07 Name P.O. Box 60 Fort Wayne. IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-TK-33 Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. 55303819-02 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code' ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-TK-33 FLANGE N/A Cat ID N/A ASME SA-182 N/A REPLACE NO SLIP ON 10" 0497003073 GR. 304 RAISED FACE FLANGE Cat ID N/A ASME SA-182 N/A REPLACE NO BLIND 10" N/A 497003072 GR. 304 RAISED FACE NUT N/A Cat ID N/A 7/8 IN DIA, 9 N/A REPLACE NO HEAVY HEX 0430212110 UNC, SA194 GR. 8F ROD N/A Cat ID N/A ASME SA453 N/A REPLACE NO THREADED 0430212300 GR. 660
7. Description of Work INSTALL FLANGE AND PIPING COMPONENTS
8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure-Other x Open Flow Path Verified Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55303819-02

9. Remarks: Final VT / PT Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed`ý Ph*` a m Administrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by J1A1L, ./ng /1.e1erir Date JL)PL 2 Engine/erirý Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108: I, Reuel K Schenck have inspected the components described in this Owner's Report during the period (0 - '- 0oo E to G - '-- Zoo , , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I . ACommissions: NB11412ANIMI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date * Ž(20 Q

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/10/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of_2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-RH-128E/ 1-IMO-314 Name One Cook Place, Bridqman, MI 49106 JOB ORDER No. 55305753-14 / 15 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, M1 49106 Expiration Date N/A Address
4. Identification of System:  : RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year. Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-RH-128E 1-IMO-314 VALVE N/A EXISTING N/A N/A N/A N/A NO BONNET VALVE N/A EXISTING N/A N/A N/A N/A NO INTERNALS
7. Description of Work SWAPPED EXISTING VALVE INTERNALS AND BONNETS
8. Test Conducted: Hydrostatic F Pneumatic D Nominal Operating Pressure W-Other E- Pressure N/A psi. Test Temp. N/A F Is

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55305753-14115

9. Remarks: VT-2 Performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phlip"  ? d : Adm inistrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by 'Ja/me's . /1/4-HL/ . /*, , Date ,J 'iii-- /3 ,20 Oý?

Engineerng(Programs CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. , I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period .- 3 - 2.U o P to tF -- Z.ovo ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ŽUr, £Jc&L-f64 CC / - ý-ý' Commissi .ons: -NB1 1412ANI. Mi. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 9"/3 200

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/13/2008 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-RH-164E Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. 55305753-17 Address Repair Org. P.O, No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31..1 1983 Add. N/A Code Case N-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda 6.. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-RH-164E VALVE CHECK FLOWSERVE Cat-ID NA ANSI CLASS N/A REPLACED NO TILTING DISC 0497001386 600 8 IN,, SA351-CF-8M PIPE N/A ,Cat- ID NA ASME NA REPLACED NO 8" Sch 40 0497001317 SA-312/376 GR TP304
7. Description of Work REPLACED VALVE AND ASSOCIATED PIPING
8. Test Conducted: Hydrostatic FI- Pneumatic FI] Nominal Operating PressureX-]

Other El Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55306753-17

9. Remarks: Fit-up VT, PT plus RT VT-2 System leakage test per Code Case N-416-1 performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed *ll'*i/ldinlProgram Administrator Date May 15 , 2008_

Owner or Owner's Designee, Title Reviewed by L4J. 61lpaAl. Date A' 7L ,20 0ý?

Engineerir~g P/,ograms CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period q - I cO6 9 to U - IS"- Z& o* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

T?*e ,,. t. Z5Ic.ie*'CS t ItL J Commissions: NB44.44ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 5-) 0) ct

, '1 1 ' '" I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

1. Owner AMERICAN ELECTRIC POWER Date 04/10/2008 Name P.O. Box60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT unit 1 Component 1-RH-128W/ 1-IMO-324 Name One Cook Place, Bridgiman, Ml 49106 JOB ORDER No. 55305754-15 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. MI 49106 Expiration Date N/A Address
4. Identification of System: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-RH-128W 1-IMO-324 VALVE ANCHOR EXISTING NA Model. # N/A N/A NO GATE 8" DARLING S70WDD
7. Description of Work REMOVED BONNET / STEM AND INSTALLED IN 1-IMO-324
8. Test Conducted: Hydrostatic 0 Pneumatic [ Nominal Operating Pressure[E Other E- Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55305754-15

9. Remarks: VT-2 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phillip Rhew Weldin, ro.ram Administrator Date May 15 ,2008 Owner or Owners Designee, Title Reviewed by /vl, /)4 Date -- ,20 .. ,

Engineefing 4rograms CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued bythe National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. 1, Reuel K Schenck have inspected the components described in this Owner's Report during the period &I- I - Zoop .. to Z4-' 7...- 2.00 ' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

itic -.

"T _*r- VI V_.Cc-el ri -I-"ýJ' Commissions: NB+-4-3+2AN1, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date5)"- - 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

1. Owner AMERICAN ELECTRIC POWER Date 03/31/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet I of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-GRC-R-603 Name One Cook Place, Bridgman, Ml 49106 JOB ORDER No. 55313439-05 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place. Bridaman. M1 49106 Expiration Date N/A Address
4. Identification of System:
5. (a) Applicable Const. Code ANSI 531.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)

I-GRC-R-603 BAR N/A Cat-ID N/A ASTM A-36 N/A REPLACE NO FLAT 0430153131 W"X 4 1" UTC-1304890 BAR N/A Cat-ID N/A ASTM A-36 N/A REPLACE NO FLAT 0430153154 Y1/4" X 1 W UTC-1304924 BEAM, N/A Cat-ID N/A ASTM A-36 N/A REPLACE NO STRUCTURAL 0430153249 S - SHAPE UTC-1305083 BEAM, N/A Cat-ID N/A ASTM A-36 N/A REPLACE NO STRUCTURAL 0430153288 W - SHAPE UTC-1305106

7. Description of Work REPLACE PIPE SUPPORT COMPONENTS
8. Test Conducted: Hydrostatic D-Pneumatic . Nominal Operating Pressure11 Other 0 Pressure N/A psi. Test Temp. N/A F

-72te-S

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55313439-05

9. Remarks: VT plus MT or PT VT-3 performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NIA Expiration Date N/A Signed P \Id~aPram , Administrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by JAP /A XEngi Date  %"ya -20 0s Engineering P.f'ograms CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 3 -. 'q - z2- 0 to I- / - zoo Er , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I 2e.eJ, C.SA),e-..itL ! ,-' L ' Commissions: NBI1412ANI, Ml. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date ý-16 2000

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/24/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-OME-3-3 Name One Cook Place, Bridgman, M1 49106 JOB ORDER No. 55316254-02 / 09 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: MAIN STEAM SYSTEM ISI CLASS 2
5. (a) Applicable Const Code ASME SEC.III CI A 1965 thru 1966 Winter Add Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer. Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No)

I-OME-3-3 BOLT N/A Cat ID N/A SA-193 N/A REPLACE NO 1 1/4" X 5" 0430009778 GR. B7 P/N 651B293H03 8 UNC

7. Description of Work REPLACE FLANGE FASTENER
8. Test Conducted: Hydrostatic I- Pneumatic E]I Nominal Operating Pressure -- I Other E'--] Pressure N/A psi. Test Temp. N/A F

~Th~s

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 55316254-02 / 09

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made inthe report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Sianed PhilliD ew eldina roarm Administrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by JAl(-*! /1. (f f K. . A, c" L Date ,IJd/6 ,20 ok' Enginegrini Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 41- / & - "Zao 8 to Z ZS-- -.2,0

.0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1' -eu-.c(.Ic4. 5"A.*.& Commissions: NBI1412ANI, MI. 300959 Inspectors Signature National Board, State, Province, and Endorsements Date 00 aO

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/23/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 1 Component 1-OME-3-3 Name One Cook Place, Bridgiman, Ml 49106 JOB ORDER No. 55316254-10 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A OnA C~ook Place_ Rridaman_ MI 4910f6 MI 49106 Expiration Date N/A One Cook Place Bridaman Address
4. Identification of System: MAIN STEAM SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ASME SEC. III CI A 1965 thru 1966 Winter Add Code Case N-496-2 (b) App!icable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer . Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-OME-3-3 HELl-COIL BABCOCK Cat ID N/A Model # N/A REPLACE NO WILCOCX CO. 040009806 5IR 18-8 S.S.
7. Description of Work INSTALL HELl-COIL IN FLANGE THREADS
8. Test Conducted: Hydrostatic El Pneumatic 1l Nominal Operating PressureD Other E' Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job OrderlFile 55316254-10

9. Remarks:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR &REPLACEMENT conforms to the rules of the ASME Code, Section X1. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed PhgifflR rV"-q&roqiram Administrator Date May 15 ,2008 Owner or Owner's Designee, Title Reviewed by JAiu 5 /1. ,1/'- /( i. 9*, I Date J*,& "' ,20 OQ Engine'erirdg Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period Lý_

1 2.1 ooO to k-1 -7 V,- Zo0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exam inations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2

-.LeuI.-( Lc-.ScJ*e',,tc //7 .[ - Commissions: NB11412ANI,MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date .'20 09

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/17/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit. 1._. Component 1-ICM-265 Name OnA Cook Pi~rac Rridnm~n_ M1 491OR JOB ORDER No. 553M6901-01 /13 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEPID.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, Ml 49106 Expiration Date N/A Address
4. Identification of System: EMERGENCY CORE COOLING SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI 631.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-ICM-265 VALVE DISC ýANCHOR Cat ID N/A ASME SA-182 N/A REPLACE NO DARLING 0430034023 TYPE UTC-1297460 F316 VALVE WEDGE ANCHOR Cat ID N/A ASTM A351 N/A REPLACE NO LOWER DARLING 0430034089 CF8M UTC-1297539 VALVE WEDGE ANCHOR Cat ID N/A ASTM A351 N/A REPLACE NO UPPER DARLING 0430034088 CF8M UTC-1297538 VALVE N/A Cat ID N/A ASTM A276 N/A REPLACE NO PIN 0430034200 T 316 UTC-1297607
7. Description of Work REPLACE VALVE INTERNALS
8. Test Conducted: Hydrostatic Pneumatic [*Nominal Operating PressureF Other LLRT Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55316901-01113

9. Remarks: LLRT Test.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A 4 Date May 15 2008 Signed Ifhi 0e[n krh/rrm Administrator ,

Owner or Owner's Designee, Title Reviewed by. -4A'&* /1. /* ii'* / /9. Date It-Ju, _ ,20 0 Engineering Pfgrams CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA.- 02108. I, Reuel K. Schenck have inspected the components described in this Owner's Report during the period 1-/- - - .o 0 E to 1-i- /I - 20 a S. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage ora loss of any kind arising from or connected with this inspection.

T,.. .I 5LeA Se. ' C- "* Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 6-1I 20

N F }

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/20/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 3 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit 2 Component 1-GRH-R-508 Name One Cook Place, Bridoman, MI 49106 Design Chan-ae 55317435-02 Address Repair Org. P.O. No., Job No., etc.

3, Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridaman, MI 49106 Expiration Date N/A Address

4. Identification of System: _: RESIDUAL HEAT REMOVAL SYSTEM ISI CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N 416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements. 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Manufacturer ASME Name Serial No. National Other Year Repaired, Code Component Manufacturer (Material M&E, Board Identification Built Replaced, Stamped ASP, PO) No. or Replacement (Yes or No) 1-GRH-R-508 PIPE, N/A Cat-ID N/A SCH 80 N/A REPLACE NO 2"NPS 0430014981 ASME SA106 UTC-1 312399 GR-B NUT N/A Cat-ID N/A ASTM A194 N/A REPLACE NO HEX HEAVY 0430034412 GR. 2H 7/8" 9 UNC BOLT N/A Cat-ID N/A ASTM A 325-94 N/A REPLACE NO

%" X 3 3/4" 0430047214 ,

BAR N/A Cat-ID N/A ASTM A36 N/A REPLACE NO ROUND " 0430047214 BAR N/A Cat-ID N/A ASTM A36 N/A REPLACE NO ROUND 7/8" 0430153094 PLATE N/A Cat-ID N/A ASTM A36 N/A REPLACE NO CS. 1/41" 0430153202

FORM NIS-2 (Back)

Job OrderiFile 55317435-02 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section xi

6. Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer National Other Year. Repaired, Manufacturer Serial No. Board Identification Built Replaced, ASME (Material M&E, No. or Replacement Code ASP, PO) Stamped (Yes or No)

PLATE N/A Cat-ID N/A ASTM A36 N/A REPLACE NO Cs. %" 0430153210 PLATE N/A Cat-ID N/A ASTM A36 N/A REPLACE NO CS. 3/4/" 0430153217 SCREW N/A Cat-ID N/A SA193 N/A REPLACE NO CAP %"X 6" 0430211350 GR. B7 NUT N/A Cat-ID N/A SA194 N/A REPLACE NO HEX HEAVY 0430211890 GR. 2H

7. Description of Work REPLACE PIPING SUPPORT
8. Test Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D Other F_1 Pressure N/A psi. Test Temp. N/A F LLS Page 2 of 3

FORM NIS-2 (Back)

Job OrderlFile 55317435-02

9. Remarks: VT plus MT or PT, VT-3 Performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE We certify that the statements made in.the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed "PWldrin r m Administrator Date May 15 ,2008_

Owner or Owner's Designee, Title Reviewed byv // 1* A*. " I" Date -JV-4g. /r ,20 Of Engineering I(ograms CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I. Reuel K. Schenck have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

" IC*C.5*.k.^"- t Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date -' 20 O)

Page 3 of 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner AMERICAN ELECTRIC POWER Date 04/24/08 Name P_0- Box 60 Fort Wavne_ IN 49801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit I Component 1-GSI-L-53 Name One Cook Place. Bridaman. MI 49106 JOB ORDER No. 55317887-01 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: SAFETY INJECTION SYSTEM 11 CLASS 2
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-GSI-L-53 PLATE N/A Cat- ID N/A ASTM A240 N/A REPLACED NO 1/2,, 0430153226 (90-02A ED)

UTC-1314558 T304, SS PLATE N/A Cat- ID N/A ASTM A240 N/A REPLACED NO 11 gage 0430153240 TYPE 304,SS UTC-1 317504

7. Description of Work REPLACE HANGER MATERIALS
8. Test Conducted: Hydrostatic F-I Pneumatic
  • Nominal Operating Pressure L Other El Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55317887-01

9. Remarks: PT of pipe after existing lug are removed. Fit-up/Final VT/PT of new lugs VT-3 Performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Sianed Phi nD e "'Vldina r Administrator Date May'15 2008 Owner or Owner's Designee, Title Reviewed by JlA1t.( M -.r/ 9*- '-a. /4t. Date 'Ju'4 /3 ,20 6 Engineering/Progfams CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. I., Reuel K. Schenck have inspected the components described in this Owner's Report during the period 41' .Z- oq to Z-/-2.*- 20.2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer

.shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~TheL (C~

X - 5 L4 0-~ -. ,if ~Commissions: NB1 1412ANI. MI. 300959 Inspectors Signature National Board, State, Province, and Endorsements Datei1 2 L

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner AMERICAN ELECTRIC POWER Date 04/27/08 Name P.O. Box 60 Fort Wayne, IN 46801 Sheet 1 of 2 Address
2. Plant D.C. COOK NUCLEAR POWER PLANT Unit I Component 1-NFP-222-V2 Name One Cook Place. Bridgman, Ml 49106 JOB ORDER No. 55318117-04 Address Repair Org. P.O. No., Job No., etc
3. Work Performed by AEP/D.C. COOK Maint. Department Type Code Symbol Stamp N/A Name Authorization No. N/A One Cook Place, Bridgman, MI 49106 Expiration Date N/A Address
4. Identification of System: REACTOR COOLANT SYSTEM ISI CLASS 1
5. (a) Applicable Const. Code ANSI B31.1 1983 Add. N/A Code Case N -666 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code (Material M&E, No. or Replacement Stamped ASP, PO) (Yes or No) 1-NFP-222-V2 PIPE N/A EXISTING N/A SA-182 N/A REPAIR NO ELBOW 900 GR. F304 SS.

PIPE N/A EXISTING N/A ASME S-376 N/A REPAIR NO 3/4" SCH. 160 GR. TP304 WELD ROD N/A UTC-1299652 N/A ER-309L N/A REPLACE NO

7. Description of Work REPAIR PIPING COMPONENTS
8. Test Conducted: Hydrostatic El Pneumatic 1 Nominal Operating PressureF W Other E__ Pressure N/A psi. Test Temp. N/A F

Page 2 of 2 FORM NIS-2 (Back)

Job Order/File 55318117-04

9. Remarks: VT-I Seal Weld, VT-I/PT on complete overlay, VT-I IAW Code Case N-666.

NRC approval to use Code Case N-666 was provided on 4/26/08.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR & REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. N/A Expiration Date N/A Signed Phillip, &)W e--diSn~qProqr am Administrator Date May 15 , 2008 Owner or Owner's Designee, Title Reviewed by J4lhts Al. f'iH~ /Q/s. /7. t* / Date ILi--' ,20 Engineerir~g Programs CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by OneCIS Insurance Company of Boston MA. 02108. 1, Reuel K. Schenck have inspected the components, described in this Owner's Report during the period -'?--G a 5 to  %- '- Zo0 fr , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

C*.*

Le.- I.S'ke ,et Ic P4 Commissions: NB11412ANI, MI. 300959 Inspector's Signature National Board, State, Province, and Endorsements Date 200O

'l