AEP-NRC-2010-56, Submittal of Owner'S Activity Report for Inservice Inspection Activities

From kanterella
Jump to navigation Jump to search
Submittal of Owner'S Activity Report for Inservice Inspection Activities
ML101940343
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/01/2010
From: Carlson M
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP-NRC-2010-56
Download: ML101940343 (6)


Text

INDIANA MICHIGAN Indiana Michigan Power POWER@ One Cook Place Bridgman, MI 49106 A unit ofAmerican Electric Power Indiana Michiga nPower. corn July 1, 2010 AEP-NRC-2010-56 10 CFR 50.55a Docket No.: 50-315 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 1 OWNER'S ACTIVITY REPORT FOR INSERVICE INSPECTION ACTIVITIES This letter provides Form OAR-I, Owner's Activity Report, for inservice inspection activities performed at Donald C. Cook Nuclear Plant Unit 1, National Board State of Michigan Number 20761 (Mich. M-096762-M), located in Bridgman, Michigan, for the period of April 29, 2008 to April 9, 2010. The plant is owned by Indiana Michigan Power Company, P.O. Box 60, Fort Wayne, Indiana, 46801. This summary report satisfies the reporting requirements described in American Society of Mechanical Engineers (ASME) Code Case N-532-4, Repair/Replacement Activity Documentation Requirements and Inservice Summary Report Preparation and Submission,Section XI, Division 1.

The Authorized Code Inspector is Mr. R. K. Schenck, who is employed by One CIS Insurance Co.,

of Boston, Massachusetts.

There are no new or revised commitments in this letter. Should you have any questions, please contact Mr. Michael K. Scarpello., Regulatory Affairs Manager, at (269) 466-2649.

Sincerel Michael H. Carlson Vice President - Site Support Services MCS/jmr

Attachment:

D.C. Cook Nuclear Plant, Form OAR-1 Owner's Activity Report

U. S. Nuclear Regulatory Commission AEP-NRC-2010-56 Page 2 c: R. Aben - DLEG/BCCFS/BD K. D. Curry - AEP Ft. Wayne, w/o attachment J. T. King - MPSC, w/o attachment MDEQ - WHMD/RPS, w/o attachment NRC Resident Inspector M. A. Satorius - NRC Region III P.S. Tam - NRC Washington DC

U. S. Nuclear Regulatory Commission AEP-NRC-2010-56 Page 3 bc: M. H. Carlson J. M. Fitchuk J. P. Gebbie C. R. Lane Q. S. Lies J. E. Newmiller J. M. Petro, Jr.

R. G. Pickard L. J. Weber

D..Co~ok Nuclear Plant

_Form OAR-I Owner's Activity Report Report Number 1-2010-3-3-02 Plant Donald C. Cook (Name and Address of Plant)

Unit No. 1 Commercial Service Date 8/23/1975 Refueling Outage No. U1C23 (if applicable)

Current Inspection Interval 3rd for Components and Sjjpet (C&S) and 2nd for Containment ISI (CISI) Program Zý 11 N b/,1dV~gp (1st, 2nd, 3rd, 4th, other)

Current Inspection Period 3rd for C&S and 1st for CISI (1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 1989 Edition/No Addenda for C&S 2004 Edition for CISI Date and Revision of inspection plans 2/19/2010, Revision 8 for C&S 11/10/2009, Revision 0 for 2nd CISI Interval Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans Edition and Addenda is the same as the inspection plans Code Cases used: N-307-3, N-416-1, N-481, N-491-2, N-498-4, N-509, N-521, N-524, N-532-4, N-533, N-616, N-623, N-627, N-652-1, N-706, N-716, N-722, N-729-1 for C&S and N-649 for CISI (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME' Code, Section Xl; and (c) the repair/replacement activities and evaluations supporting the completion of ULC23 conform to th re

  • nts of Section Xl. (Refueling Outage Number)

Signed *L'0Qjb H FW1 Date 11/7/ o 0 Owners or Owner.s Designee, T e rj. .

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by One CIS Insurance Co. of Boston, MA have inspected the items described in this Owner's ActivityReport, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions Michigan 300959, NB 11412, Endorsements; A,N & I Inspector's Signature National Board, State, Province, and Endorsements Date *-i7-.OIO 6/15/20.10 U1C23 Refueling Outage Page' .1 -3

D.C. Cook Nuclear Piant Table I Items with flaws or relevant conditions that required evaluation for continued service Examination Item Number Item Description Evaluation Description Category B-N-2 B13.60 Interior Attachments Beyond Beltline Region AR 2010-1804-18, Unit 1 Reactor Vessel Core Support Lug Bolting Anomalies F-A F I.10A Class 1 Piping Supports 1-GCS-R-540 AWAY# 201 00733, Identified discrepancies during visual examination F-A. F1.30A Class 3 Piping Supports 1-GCCW-R-60 eSAT# 10042044, Identified discrepancies during visual examination F-A FI.30A Class 3 Piping Supports .1-GCCW-R-22 eSAT# 10042048, Identified discrepancies during visual examination F-A Fl.30A Class 3 Piping Supports 1-GCCW-L-236 eSAT# 10013050, Identified discrepancies during visual examination F-A F1.30A Class 3 Piping Supports 1-GFW-R-179 eSAT# 10013056, Identified discrepancies during visual examination F-A F1.30WB Class 3 Piping Supports 1-AFW-L-915, AR 00861050-01, NCE for broken lug on piping, found outside normal ISI examination 6/15/2010 U1C23 Refueling Outage Page 2 of .3

D.C. Cook Nuclear Plant Table 2 Abstract of repair/replacement activities required for continued service Code Class item Description Description of Work Date Complete Repair/ Replacement Plan Number 1 Class 1 Piping Support Replace Bolt 3/21/2010 55359762-01 6/15/2010 U1C23 Refueling Outage Page 3 of 3