Text

INDIANA Indiana Michigan Power MICHIGAN Cook Nuclear Plant POWERe One Cook Place Bridgman, MI 49106 A unit of American Electric Power lndianaMichiganPower.com February 7, 2014 AEP-NRC-2014-13 10 CFR 50.55a Docket No.: 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 2 Form OAR-1 Owner's Activity Report This letter provides a copy of Form OAR-1 Owner's Activity Report for inservice inspection activities performed at Donald C. Cook Nuclear Plant (CNP) Unit 2 through the completion of the U2C21 refueling outage. This report meets the requirements of the American Society of Mechanical Engineers (ASME) Code Case N-532-4, "Repair/Replacement Activity' Documentation Requirements and Inservice Summary Report Preparation and Submission, Section Xl, Division 1."

This code case is used as an alternative to the requirements of the ASME Boiler and Pressure Vessel Code, Section Xl, Article IWA-6000 as approved by Regulatory Guide 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 16."

The Authorized Code Inspection Company is OneCIS Insurance Co., of Lynn, Massachusetts. The Authorized Nuclear Inspector is Reuel Schenck.

There are no new or revised commitments in this letter. Should you have any questions, please contact Mr. Michael K. Scarpello, Regulatory Affairs Manager, at (269) 466-2649.

Sincerely,

/ShaneLies Engineering Vice President RAW/amp

Enclosure:

Form OAR-1 Owner's Activity Report for the Donald C. Cook Nuclear Plant Unit 2 Cycle 21 2013 Refueling Outage

U. S. Nuclear Regulatory Commission AEP-NRC-2014-13 Page 2 c: J. T. King - MPSC, w/o enclosure S. M. Krawec - AEP Ft. Wayne, w/o enclosure MDNRE - WHMD/RPS, w/o enclosure NRC Resident Inspector C. D. Pederson - NRC Region III W. Vallance - DLEG/BCCFS/BD T. J. Wengert - NRC Washington DC

Enclosure to AEP-NRC-2014-13 FORM OAR-1 OWNER'S ACTIVITY REPORT FOR DONALD C. COOK NUCLEAR PLANT UNIT 2 CYCLE 21 2013 REFUELING OUTAGE

D.C..Cook Nuclear Unit 2 Form OAR-I Ownerws Activity Report::

Report Number 2-2013-4-2-01 Plant Donald C. Cook Nuclear Plant, One Cook Place, Bridgman, Michigan 49106 (Name and Address of Plant)

Unit No. 2 Commercial Service Date 711/1978 Refueling Outage No. U2C21 (ifapplicable)

Current Inspection Interval 4th for Components and Supports (C&S) and 2nd for Containment ISI (CISI) Program (1st, 2nd, 3rd, 4th, other)

Current Inspection Period 2nd for C&S and 2nd for CISI (1st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 2004 Edition/No Addenda Date and Revision of inspection plans 1/8/2013, Revision 3 for C&S, and 6/27/2012, Revision 2 for CISI Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the Inspection plans Edition and Addenda same as the inspection plans Code Case used: N-526, N-566-2, N-624, N-716, N-722-1, N-729-1 for C&S and N-649 for CISI (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made In this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repairfreplacement activities and evaluations supporting the completion of U2C21 conform to the r ments of Section XI. Dat (Refueling Outage Number)

Signed 5, N oc IC11Date 121@7 t 0 1g Ownera or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Michigan and employed by One CIS Insurance Co. of Lynn, MA have inspected the items described in this Owner's ActivityReport, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report In accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repalr/replacement activities and evaluation described In this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or loss of any kind arising from or connected with this Inspection.

I~=i M" .

S*"SJs-Lr~ ," k__LO Commisslons Michigan 300959, NB 11412, Endorsements: A, I, N, NS & IS Inspectors Signature National Board, State, Province, and Endorsements Date '7 72-,, 4/

Page 1 of 3

Table I Items with flaws or relevant conditions that required evaluation for continued service Page 2 of 3

D.C. Cook Nuclear Unit 2 Table 2 Abstract of repair/replacement activities required for continued service Code Class Item Description Description of Work Date Complete Repair/ Replacement Plan Number None None None None None Page 3 of 3