Issue date | Title | Topic | |
---|---|---|---|
ML20084K498 | 5 October 1976 | Updates AOs 50-265/74-3,50-265/74-13,50-265/74-16 & 50-265/74-19 Re low-low Reactor Water Level Switch LIS-2-263-728 Failure.Surveillance Interval Changed to Monthly.Switch Installation Delayed Pending Analog Trip Sys | |
ML20084S229 | 19 December 1975 | Supplementary Ao:Four Temp Switches Were Found to Trip at Values Exceeding Tech Specs Limits.Caused by Sensors Placed Too Closely to HPCI Turbine & Steam Piping.Different Temp Sensor Will Be Installed | |
ML20084S556 | 19 November 1975 | Preliminary Ao:On 751109,traversing Incore Probe (TIP) Ball Valve 2 Failed to Close.Manual Attempts to Close Valve Failed.No Cause Stated.Addl Info Will Be Submitted in AO 50-265/75-45 | Squib |
ML20084S585 | 17 November 1975 | AO 50-265/75-44:on 751107,RCIC Turbine Tripped.Caused by Failure of Hydraulic Fluid servo-valve Actuator.Actuator Replaced & Overspeed Trip Mechanism Repaired | |
ML20084S573 | 10 November 1975 | Preliminary Ao:On 751107,reactor Core Isolation Cooling (RCIC) Sys Turbine Tripped.Caused by Failure of Hydraulic Fluid servo-valve actuator.Servo-valve Actuator Will Be Replaced.Addl Info Will Be Submitted in AO 50-265/75-44 | |
ML20084S593 | 30 October 1975 | Ao:On 751029,RHR Sys 2 Supply from Emergency Diesel & Core Spray Sys 2 Bus/Logic Power Failure Alarms Received.Caused by Switch 12 in Off Position.Switch Returned to on Position. Addl Info Will Be Submitted in AO 50-265/75-43 | |
ML20084S602 | 28 October 1975 | AO 50-265/75-42:on 751018,differential Pressure Across B Train of Standby Gas Treatment Sys Exceeded Tech Spec Limit. Caused by Fouling of High Efficiency Prefilter.Filter Changed & Tested Satisfactorily | |
ML20084S619 | 27 October 1975 | AO 50-265/75-41:on 751018,while Performing Monthly Diesel Generator Surveillance Test,Diesel Generator Reactive Power Meter in Control Room Pegged Full Scale.Megawatt Output Load Erratic.Operator Tripped Diesel.Caused by Equipment Failure | |
ML20084S777 | 24 October 1975 | AO 50-265/75-38:on 751014,weld Exams Indicated Crack on B Loop of Rx Recirculation Discharge Bypass Line.Caused by Intergranular Stress Assisted Corrosion.Both Bypass Lines Will Be Removed | |
ML20084S647 | 24 October 1975 | AO 50-265/75-40:on 751016,while Performing Routine Surveillance,Three High Drywell Pressure Scram Switches Found to Exceed Tech Spec Limit.Apparently Caused by Instrument Drift.Pressure Switches Recalibr & Tested | |
ML20084S674 | 24 October 1975 | AO 50-265/75-39:on 751016,one Bergen-Patterson & Two Grinnell Hydraulic Snubbers Found W/Empty Oil Reservoirs. Apparently Caused by Equipment Failure.Snubbers Will Be Repaired or Replaced | Earthquake |
ML20084S612 | 20 October 1975 | Telecopy AO 50-265/75-42:on 751018,differential Pressure Across B Train Particulate Filters of Standby Gas Treatment Sys Exceeded Tech Specs.Caused by Smoke from Small Fire Created by Onsite Welders.Work Request Issued | |
ML20084S207 | 20 October 1975 | Telecopy Ao:On 751020,radwaste Discharge Batch 3709 Discharged at Rate Which Exceeded Tech Spec Limit.Further Info to Be Provided in AO 50-254/75-22 | |
ML20084S629 | 18 October 1975 | Telecopy AO 50-265/75-41:on 751017,during Monthly Surveillance Testing of Diesel Generator,Electrical Flash Burned Out Diode Rectifier Array of Generator Exicitation Circuitry.Output Breaker Tripped.Generator Inoperable | |
ML20084S656 | 17 October 1975 | Telecopy AO 50-265/75-40:on 751016,during Routine Monthly Surveillance,Three High Drywell Pressure Switches Found to Exceed Tech Spec Limit.Cause Not Stated.Instruments Recalibr & Tested Satisfactorily | |
ML20084S683 | 17 October 1975 | Telecopy AO 50-265/75-39:on 751016,two Grinnell & One Bergen-Patterson Hydraulic Snubbers Found Defective.Cause Not Stated.Work Request Issued for Repair | |
ML20084S782 | 17 October 1975 | AO 50-265/75-37:on 751007,minor Leakage from B Feedwater Flush Line Observed.Caused by Equipment Failure.Flush Line Being Repaired | |
ML20084S218 | 15 October 1975 | Telecopy Ao:On 751014,two High Drywell Pressure Scram Switches Found in Isolated Condition.Further Info to Be Provided in AO 50-254/75-21 | |
ML20084S768 | 14 October 1975 | Telecopy Ao:On 751014,crack Indication Confirmed on B Loop in heat-affected Zone on Pipe Side of pipe-to-weldolet Weld. Repair Plans Incomplete.Addl Info Will Be Submitted in AO 50-265/75-38 | |
ML20084S785 | 7 October 1975 | Telecopy Ao:On 751007,pipe Crack Found on Feedwater Flush Line 2-3206B-4-C at Main Feedwater Line 2-3204B-18-C.Minor Leakage Did Not Affect Reactor Inventory.Repairs Initiated. Addl Info Will Be Submitted in AO 50-265/75-37 | |
ML20084S039 | 31 August 1975 | Telecopy Ao:On 750830,while Performing Monthly RCIC Operability Surveillance Test RCIC Would Not Reach Normal Conditions.Possibly Caused by Overspeed Mechanism.Required Testing of HPCI Sys Initiated | |
ML20084R987 | 31 August 1975 | Telecopy of AO 50-265/75-36:on 750831,during Shutdown, Instability Was Experienced on Feedwater Control Sys Which Caused 3/4 Inch Drain Lines to Sever from Low Flow Feedwater Regulating Valve.No Radioactive Matl Released | |
ML20084S004 | 31 August 1975 | Telecopy Ao:On 750830,while Testing Operability of HPCI Sys, Auxiliary Oil Pump Kept Tripping & HPCI Turbine Failed to Start.Orderly Shutdown Was Initiated.Further Info to Be Provided in AO 50-265/75-35 | |
ML20084S065 | 25 August 1975 | Telecopy Ao:On 750825,oil Separator Overflowed Into Spray Canal Releasing Contaminated Water.Caused by Rainfall. Remaining Water in Oil Separator Being Discharged as Controlled Batch Release | |
ML20084S099 | 25 August 1975 | Telecopy Ao:On 750824 Grinnel Snubber Had Empty Fluid Reservoir & Bergen-Paterson Snubber Had Leaking Accumulator. Replacement Parts Installed Prior to Reactor Startup on 750825.Further Info to Be Provided in AO 50-265/75-32 | |
ML20084S183 | 18 August 1975 | Telecopy Ao:On 750817,following Maint Outage,Reducer of Low Flow Feedwater Regulating Valve 2-643 Severed Due to Vibration.Unit Manually Scrammed & Reactor Level Maintained W/Rcic Sys | |
ML20084S247 | 15 August 1975 | AO 50-254/74-19:on 750805,reactor High Pressure Scram Switch 1-263-55A Was Isolated.Caused by Switch Left Isolated After Completion of Previous Month Testing.Establishment of Administrative Control Over Valves Initiated | |
ML20084S223 | 13 August 1975 | Telecopy Ao:On 750812,ECCS Low Pressure Permissive Sensor PS-2-263-52A Discovered in Isolated condition.PS-2-263-52A Put Into Svc & All Switches Satisfactorily Functionally Tested.Further Info to Be Provided in AO 50-265/75-30 | |
ML20084S222 | 11 August 1975 | Telecopy Ao:On 750809,standby Liquid Control Pump 1A Produced Flow Rate Below Tech Spec Limit.Caused by Premature Lifting of Relief Valve RV-1-1105A.Relief Valve Reset. Further Info to Be Provided in AO 50-254/75-20 | |
ML20084S237 | 8 August 1975 | AO 50-265/75-28:on 750729,RHR Svc Water Pump 2A Fell Below Required Flow Level & Pump Pressure Limit.Caused by Accumulation of Debris Lodged in Pump Suction & Impeller. Debris Was Removed | |
ML20084S226 | 8 August 1975 | AO 50-265/75-27:on 750729,during HPCI Monthly Surveillance Operation Only Able to Attain Pump Flow Below Tech Spec Limit.Caused by Improper Pinning of Pilot Valve Lever Arm. Lever Arm Adjusted | |
ML20084S254 | 5 August 1975 | Telecopy Ao:On 750805,reactor High Pressure Scram Switch PS-1-263-55A Was Still Valved Out from Previous Month Surveillance.Switch Was Calibr & Valved in Svc.Further Info to Be Provided in AO 50-254/75-19 | |
ML20084S259 | 4 August 1975 | AO 50-265/75-26:on 750725,oxygen Level of Unit 2 Suppression Chamber Exceeded Tech Spec Limit.Caused by Insufficient Nitrogen Available to Inert Primary Containment Due to Leaking Flange.Gasket in Nitrogen Line Replaced | |
ML20084S331 | 1 August 1975 | AO 50-254/75-18:on 750724,pressure Switch PS-1-1622B Tripped at Value Exceeding Tech Spec.Caused by Instrument Drift.Pressure Switch Recalibr | |
ML20084S375 | 31 July 1975 | AO 50-254/75-17:on 750721,traversing Incore Probe Machine Three Ball Valve Failed to Close When Detector Was Withdrawn to in-shield Position.Caused by Failure of Spring to Close Ball Valve Completely.New Valve Installed | |
ML20084S232 | 31 July 1975 | Telecopy Ao:On 750731,4 of 16 HPCI Area High Temp Switches Tripped at Values in Excess of Tech Spec Limits.Switches Calibr.Further Info to Be Provided in AO 50-265/75-29 | |
ML20084S318 | 31 July 1975 | AO 50-265/75-25:on 750721,two Hydraulic Snubbers Found to Have Empty Oil Reservoirs.Caused by Several Oil Leaks for One Snubber.Failure of Second Snubber Unknown.One Snubber Fitting Tightened & Other Snubber Replaced | Earthquake |
ML20084S242 | 30 July 1975 | Telecopy Ao:On 750729,RHR Sys Svc Water Pump 2A Failed to Meet Tech Specs Required Flow Rate.Work Request 2794-75 Immediately Issued for Investigation & Repair.Further Info to Be Provded in AO 50-265/75-28 | |
ML20084S246 | 29 July 1975 | Telecopy Ao:On 750729,HPCI Sys Could Not Obtain Tech Spec Required Flow Rate.Cause Unknown.Eccs Testing Begun as Investigation.Further Info to Be Provided in AO 50-265/75-27 | |
ML20084S664 | 29 July 1975 | AO 50-265/75-24:on 750720,crack Found on Reactor Feedwater Sys Flushing Line 2-3206B-4-C.Caused by Stress Point Due to Improper Blending of Fillet Weld.New Section of Pipe Welded | |
ML20084S336 | 28 July 1975 | Telecopy Ao:On 750724,pressure Switch 1-1622B Found to Trip at Value Exceeding Tech Specs Limit.Switch Was Immediately Recalibr.Further Info to Be Provided in AO 50-254/75-18 | |
ML20084S264 | 25 July 1975 | Telecopy Ao:On 750725,during Completion of Inerting,Primary Containment Oxygen Concentration Was Not within Tech Spec Limits.Further Info to Be Provided in AO 50-265/75-26 | |
ML20084S693 | 25 July 1975 | AO 50-265/75-23:on 750718,high Drywell Pressure Switch 2-1001-89B Failed to Operate.Caused by Dirt & Scale Plugging Pressure Pulsation Damper.Damper Cleaned | |
ML20084S390 | 25 July 1975 | AO 50-254/75-16:on 750717,unsampled Laundry Water Added to Floor Drain Sample Tank River.Caused by Operator Error. Radwaste Foreman Must Verify Valve Checkoff List Prior to Discharging to River | |
ML20084S713 | 24 July 1975 | AO 50-265/75-22:on 750716,two of Four High Drywell Pressure Switches Exceeded Tech Specs Limit.Caused by Instrument drift.PS-2-1001-88B & C Calibr to Trip at 1.90 Psi | |
ML20084S626 | 22 July 1975 | Telecopy Ao:On 750721,traversing Incore Probe (TIP) 3 Ball Valve Failed to Close.Shift Foreman Went to TIP Cubicle & Tapped Valve,Causing Valve to Close.Further Info to Be Provided in AO 50-254/75-17 | |
ML20084S326 | 22 July 1975 | Telecopy Ao:On 750721,one Grinnell & One Bergen-Paterson Snubber Found Defective.Work Request Issued for Repair. Further Info to Be Provided in AO 50-265/75-25 | |
ML20084S679 | 21 July 1975 | Telecopy Ao:On 750720,water Discovered in MSIV Room.Caused by Crack on Feedwater Flush Line B.Preparations Currently Being Made for Repair of Cracked Line | |
ML20084S616 | 18 July 1975 | Telecopy Ao:Laundry Drain Sample Tank Level Dropped & Floor Drain Sample Tank a Level Rose.Caused by Not Verifying Closing of Laundry Tank Discharge Valve.Discharge Immediately Stopped | |
ML20084S698 | 18 July 1975 | Telecopy Ao:On 750718,pressure Switch 2-1001-893 Failed to Operate at Any Pressure.Work Request 2640-75 Initiated to Investigate & Correct Problem |