ML20235G931

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 70-1151/87-10 on 870615-19 & Notice of Violation.Concerns Noted Re Similarity of Encl Violation & Violation Noted in NRC ,Per 870625 Telcon
ML20235G931
Person / Time
Site: Westinghouse
Issue date: 07/02/1987
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Loch E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20235G932 List:
References
NUDOCS 8707140431
Download: ML20235G931 (2)


Text

_ -. . _- . . --

L- i

.. f s

}

c ,

.. .JU L O'21987 Docket No. 70-1151-License No. SNM-1107-f i Westinghouse Electric Corporation 6 ATTN: Mr. E. P. Loch, Manager Columbia Plant Commercial Nuclear Fuel Division Drawer R

-Columbia, SC 29250

.. Gentlemen:

1

SUBJECT:

NOTICE OF VIOLATION (NRCINSPECTIONREPORTNO. 70-1151/87-10)

.This refers to the Nuclear Regulatory Commission'(NRC) inspection conducted by G. L. Tioup. on June 15-19, 1987. The inspection included a review of activities authorized for your Columbia ' facility. At the conclusion of the

-inspection,. the findings.were discussed with you and members of your staff.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of' selective examinations of procedures and ~ representative records, interviews with personnel, and observation of activities in progress.

The inspection findings indicate that certain activities appeared to violate NRC requirements. The violation, references to pertinent requirements, and elements to be included in your response are described in the enclosed Notice of Violation.

The violation described in the enclosed Notice is similar to a violation contained in the Notice sent to you by our letter dated March 28, 1986.

Because "similar violations," as described in the NRC Enforcement Policy, are-of significant concern to the NRC, please give particular attention in your response to the identification of the root cause of this problem and your corrective action to prevent recurrence. The NRC concerns regarding similar violations-were discussed in a tele) hone conversation on June 25, 1987, between W. L. Goodwin of your staff and W. E. Cline of this office. 4 In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and its enclosures

.will be-placed in the NRC Public Document Room.

Theresponsesdirectedbythisletteranditsenclosuresarenotsubjecttothe clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

8707140431 870702 1 PDR ADOCK 0700 C

1 l' I LEoq

r__-__-__ . _ _ _ _ - __ . _ _ _ _ . _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ ._

}

Westirjghouse Electric Corporation 2 At 0 21997 Should you have any questions concerning this letter, please contact us.

Sincerely, V'

{\f[l)\00.b4LSYi20)00Ylb5 J. Philip Stohr, Director Division of Radiation Safety and Safeguards

Enclosures:

1. Notice of Violation
2. NRC Inspection Report bgc w/o encl:

t/icenseFeeManagementBranch Document Control Desk State of South Carolina O

RII RII RI e k E p e fWCine Je- d 730/07 6/30/87 6/fo/87 27I/l /87 g

--