ML20153C475
| ML20153C475 | |
| Person / Time | |
|---|---|
| Site: | Westinghouse |
| Issue date: | 09/18/1998 |
| From: | Ting P NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Allen J WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| References | |
| 70-1151-98-203, NUDOCS 9809240102 | |
| Download: ML20153C475 (2) | |
Text
_. _ _
r..
September 18, 1998 Westinghouse Electric Corporation
~ Commercial Nuclear Fuel Division ATTN:. Jack Allen, Columbia Plant Manager P.O. Drawer R Columbia, SC 29250
SUBJECT:
REPLY TO NOTICE OF VIOLATION
Reference:
NRC Inspection Report No. 70-1151/98-203
Dear Mr. Allen:
Thank you for your response of August 6,1998, to the Notice of Violation (NOV) issued with the reference inspection report of July 7,1998. We have reviewed your response to the NOV and your corrective actions and determined that it meets the requirements of 10 CFR 2.201. The j
implementation of your corrective actions will be reviewed during future inspections.
In accordance with the requirements of 10 CFR 2.790, a copy of this letter will be placed in the Public Document Room. Should you have any questions concerning this letter, please contact Dennis Morey of my staff at (301) 415-6107.
Sincerely, Original signed by W. Troskoski for P. Ting Philip Ting, Chief Operations Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1151 License No. SNM-1107 DISTRIBUTION NRC File Center CGaskin, FCLB FCSS r/f
}'
Docket File 70-1151 TPham,FCLB FCOB r/f
'}
PDR EMcAlpine, Ril Case File LPDR JKirby, Ril NMSS r/f BGloerien, Ril ggf) $
a:\\(Westinghouse disk) respwest.nov FCOB l Cl FCOB l6 FCOB FCOB l
l PHarich [
DMoregM WTroskoskFm/
PTing /g 9A%8 94~{98 9W98-9/fl98M OFFICIAL RECORD COPY 9809240102 980918 Y
PDR ADOCK 07001151 i C
PDR ME WHE WY
P
$ CtCO o
8-J&
UNITED STATES E ' ) *'
E NUCLEAR REGULATORY COMMISS!ON 1
E
%'s W A SHf NGTON, D.C. 20557.r.0001 September 18, 1998
)
Westinghouse Electric Corporation Commercial Nuclear Fuel Division ATTN: Jack Allen, Columbia Plant Manager P.O. Drawer R Columbia, SC 29250
SUBJECT:
REPLY TO NOTICE OF VIOLATION
Reference:
NRC Inspection Report No. 70-1151/08-203
Dear Mr. Allen:
Thank you for your response of August 6,1998, to the Notice of Violation (NOV) issued with the reference inspection report of July 7,1998. We have reviewed your response to the NOV ar.d your corrective actions and determined that it meets the requirements of 10 CFR 2.201. The implementation of your corrective actions will be reviewed during future inspections.
in accordance with the requirements of 10 CFR 2.790, a copy of this letter will be placed ia the Public Document Room. Should yoa have any questions concerning this letter, please contact Dennis Morey of my staff at (301) 415-6107.
Sincerely, Ye Philip Ting, Chief Operations Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1151 License No. SNM-1107