j, '

DEdONTROLLE.D WHEN 2.790 INFORMATION IS REMOVED DOCUZENT TRANSMITTED HEREWITH CONTAINS 2.790 INFORMATION Westinghouse Electric Company May 10, 1999 j ATTN: Mr. J. B. Allen, Plant Manager Columbia Fuel Fabrication Facility l P.O. Drawer R l Columbia, SC 29250

SUBJECT:

INSPECTION REPORT NO. 70-1151/99-202

Dear Mr. Allen:

A routine inspection of your facility's material control and accounting (MC&A) safeguards program was conducted by the Nuclear Regulatory Commission (NRC) on April 19-23,1999.

The enclosed report presents the scope, results and details of the inspection.

The inspection consisted of selective examinations of MC&A procedures and representative j records, interviews with personnel, and observations of activities in progress. At the conclusion of the inspection, the findings were discussed with you and members of your staff.

Under the provisions of Section 2.790(d), reports containing information related to a licensee's MC&A program are exempt from public disclosure. Accordingly, the enclosure will not be placed l' in the Public Document Room.

Should you have any questions concerning this inspection, please contact ae at (301) 415-7156.

l Sincerely, I Original /s/

Philip Ting, Chief Operations Branch b0 00k51 Division of Fuel Cycle Safety C PDR and Safeguards, NMSS Docket No. 70-1151 1,Mense No. SNM-1107 Enciosure: As stated cc w/ enclosure: W. Goodwin, Manager, Regulatory Affairs, Westinghouse cc w/o enclosure: Max K. Batavia, P.E., Chief j, Bureau of Radiological Health, State of South Carolina i DISTRIBUTipN:

NRC File Center Case File FCSS r/f NMSS rif Docket 70-1151 FCOB r/f CCollins, FCOB EMcAlpine, Ril PDR/LPDR CEmeigh, FCLB JOlencz, FCOB /

LHarris, FCOB CGaskin, FCLB k MMessier, (w/o enc!) FCOB r/f ,

t g ANorris, PMDA (w/o enc!)

DOCUMENT NAME:(Westinghouse disk) wes99202.wpd 0FC FCOB h FCOB FCOB FCOB N FCOB [-

NAME PHarich DWhaley k a/ WSmith (JS $ WSchwink h PT ingf DATE I/ d/99 I/de/99 5 / 7/99 (/l099

/ 17/9/99 C= COPY E - COVER & E L OSURE N = NO COPY d Lf4 L rN ( L I i >

l . -

P D r-DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED I) f DOCUMENT TRANSMITTED HEREWITH CONTAINS 2'.790 INFORMATION

~

i .

  • DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED Ad DOCUMENT TRANSMITTED HEREWITH CONTAINS 2.790 INFORM ATION g l

~

pA 4 UNITED STATES g NUCLEAR REGULATORY COMMISSION

..... May 10, 1999 Westinghouse Electric Company ATTN: Mr. J. B. Allen, Plant Manager )

Columbia Fuel Fabrication Facility {

P.O. Drawer R Columbia, SC 29250

SUBJECT:

INSPECTION REPORT NO. 70-1151/99-202

Dear Mr. Allen:

)

1 A routine inspection of your facility's material control and accounting (MC&A) safeguards program was conducted by the Nuclear Regulatory Commission (NRC) on April 19-23,1999.

The enclosed report presents the scope, results and details of the inspection.

The inspection consisted of selective examinations of MC&A procedures and representative records, interviews with personnel, and observations of activities in progress. At the conclusion of the inspection, the findings were discussed with you and members of your staff.

Under the provisions of Section 2.790(d), reports containing information related to a licensee's MC&A program are exempt from public disclosure. Accordingly, the enclosure will not be placed in the Public Document Room.

Should you have any questions concerning this inspection, please contact me at (301) 415-7156.

i Sincerely, Philip Ting, Chief Operations Branch Division of Fue! Cycle Safety and Safeguards, NMSS i l

Docket No. 70-1151 License No. SNM-1107

Enclosure:

As stated cc w/ enclosure: W. Goodwin, Manager, Regulatory Affairs, Westinghouse cc w/o enclosure: Max K. Batavia, P.E., Chief Bureau of Radiological Health, State of South Carolina DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED DOCUMENT' , NSMITTED HEREWITH CONTAINS 2.790 INFORMATION