y 1
August 26, 1998 Westinghouse Electric Corporation ATTN: Mr. J. B. Allen. Manager Columbia Plant Commercial Nuclear Fuel Division Drawer R Columbia. SC 29250
SUBJECT:
NRC INSPECTION REPORT NO. 70-1151/98-06 AND NOTICE OF VIOLATION
Dear Mr. Allen:
This refers to the ins)ection conducted on August 3-7. 1998, at the Columbia Nuclear Fuel Plant.
T1e purpose of the inspection was to determine whether activities authorized by the license were conducted safely and in accordance with NRC requirements. At the conclusion of the inspection, the findings were discussed with those members of your staff identified in the enclosed report.
Areas examined during the inspection are identified in the report. Within these areas. the inspection consisted of selective examinations of procedures and representative records. interviews with personnel, and observation of activities in progress.
Based on the results of this inspection certain of your activities a)peared to be in violation of NRC requirements, as specified in the enclosed lotice of Violation (Notice). The violation involved three individuals who were not i
adequately instructed in the general safety information required by 10 CFR 19.12.
The violation is of concern because it involved persons with access to Special Nuclear Material that were not properly informed on the importance of and techniques for protecting personnel from exposure to radiation, and could have led to an unnecessary radiation exposure to plant
}/
personnel.
The NRC has concluded that information regarding the reason for the violation.
'/
the corrective actions taken and planned to correct the violation and prevent recurrence is already adequately addressed on the docket in the enclosed inspection report.
Therefore, you are not required to respond to this letter unless the description therein does not accurately reflect your correction actions or your position.
In that case or if you choose to provide additional information, you should follow the instructions specified in the enclosed Notice.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice." a copy of this letter and its enclosures will be placed in the NRC Public Document Room.
980909021e 980826 PDR ADOCK 07001151 C
PDR g
_.zr 07
}
I WEC 2
Should you have any questions concerning this letter, please contact us.
Sincerely, (original signed by E. J. McAlpine)
Edward J. McAlpine, Chief Fuel Facilities Branch Division of Nuclear Materials Safety Docket No. 70-1151 License No. SNM-1107
Enclosures:
1.
NRC Inspection Report cc w/encis:
Wilbur Goodwin, Manager Regulatory Affairs Westinghouse Electric Corporation Commercial Nuclear Fuel Division Drawer R Columbia, SC 29250
' Virgil R. Autry, Director Div. of Radioactive Waste Mgmt.
S. C. Department of Health and Environmental Control 2600 Bull Street Columbia. SC 29201 i
Distribution w/encls:
E. McAlpine. RIl D. Ayres RII P.. Harich. NMSS P. Hiland. RIII W. Britz RIV B. Spitzberg, RIV P. Ting. NMSS M. Weber, NMSS i
PUBLIC (See next page for previous concurrences)
OFFICE RII DMES RII DIRES RII DIOES SISEkTURE IBMIB RE8watsell DAseymour DAAyres D&TE 8/
/98 8/
/98 8/
/98 8/
/98 8/
/98 8/
/98 8/
/98 COPY?
YES NO YE5 NO YE5 NO YES NO YES NO YES NO YES NO OFFICIAL RECORD COPY DOCUMENT NAME: Gs\\ REPORTS \\IR9806.R0
WEC 2
Should you have any questions concerning this letter, please contact us.
Sincerely.
Edward J. McAlpine. Chief Fuel Facilities Branch Division of Nuclear Materia' Safety Docket No. 70-1 1
License No. SNM-1 7
Enclosures:
1.
Noti e of Violation 2.
NRC I ection Report cc w/encls:
Wilbur Goodwin Manager Regulatory Affairs Westinghouse Electric Corporati Commercial Nuclear Fuel Division Drawer R t
Columbia. SC 29250 Virgil R. Autry. Director Div. of Radioactive Waste Mgmt.
S. C. Department of Health and Environmental Control 2600 Bull Street Columbia. SC 29201 Distribution w/encls:
E. McAlpine. Rll D. Ayres. RII i
D. Seymour. RII P. Hiland. RIII l
C. Cain. RIV F. Wenslawski. RIV P. Harich. NMSS P. Ting. NMSS M. Weber. NMSS PUBLIC Distribution w/o encls:
i License Fee Management Branch UFFICE Ril:DWIE Ril:DIBIE Ril:DIBIS 511MILTIME sgs
'g h.
VW WWE RE5Metzell DA5eyneur DAAyres DATE 5/ g,4 /95 5/ 25 /95 5/_t w /95 5/
/95 5/
/95 5/
/95 5/
/95
'i55 11 0 (T W WO GE[
11 0 YES 11 0 YES 10 0 YES 10 0 YE5 NO wrv r OFFICIAL RECORD CDPY D003ENT IIAfE: G:\\ffBil\\REPOR15\\lR9006.R0 i
!