05000317/LER-1987-002, Closes LER 87-002 (Ref 4) Re Main Steam Pipe Flaw.Results of Review of Several Analyses & Other Info Transmitted in Several Ref Ltrs Being Awaited

From kanterella
(Redirected from ML20154C905)
Jump to navigation Jump to search
Closes LER 87-002 (Ref 4) Re Main Steam Pipe Flaw.Results of Review of Several Analyses & Other Info Transmitted in Several Ref Ltrs Being Awaited
ML20154C905
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 09/07/1988
From: Gahan M
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8809150071
Download: ML20154C905 (2)


LER-2087-002, Closes LER 87-002 (Ref 4) Re Main Steam Pipe Flaw.Results of Review of Several Analyses & Other Info Transmitted in Several Ref Ltrs Being Awaited
Event date:
Report date:
3172087002R00 - NRC Website

text

e.

O

. =,l .

BALTIMORE GAS AND I ELECTRIC '

CHARLES CENTER P.O. BOX 1475 BALTIMORE. MARYLAND 21203 NUCtEAR ENGINEERING SERVICES DEPARTMENT cavant curas Nvettaa Powse PW wsey. uAanano eas' September 7, 1988 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 l

ATTENTION: Document Control Desk l l

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit No.1; Docket No. 50 317 Main Steam Pipe Flaw

REFERENCES:

(See Attached)

Centlemen:

This letter is written to close LER 87-02 (Reference 4). There has been considerable correspondence between us on this subject. Hence, we have concluded it would be redundant to issue a supplement to the LER.

Currently, we are awaiting the results of your review of several analysas and other information transmitted to you in several of the referenced letters. We anticipate that with this information you will j conclude that no further actions need to be taken on our part.

l We appreciate your attention to this matter.

I

Very trtily yours, g [ -s 7 l Michact J. Cahan, III
Principal Engineer Plant & Project Engrg. Section ,

KJC/dj t ec: D. A. Brune, Esquire J. E. Silberg, Esquire R. A. Capra, NRC '

S. A. McNeil NRC W. T. Russell, NRC D. C. Trimble/V. 1.. Pritchett, NRC T. Magette, CNR gL

@"MA 828% PNU

'/B

e o .~.

.. Document Centrol Deck September 7, 1988 Page 2

REFERENCES:

(1) Letter from Mr. A. R. Thornton (BC&E) to Mr. Ashok C. i Thadani (NRC), dated December 16, 1986; Request for i Approval of Main Steam Piping Evaluation per ASME Section XI, IWB 3600 and Relief from IWB-3610(b).

(2) Letter from Mr. A. R. Thornton (BC&E) to Mr. Ashok C.

Thadani (NRC), dated December 19, 1986; Request for Approval to Update to Later Edition of ASME Code Section XI for Acceptance Standards, t

(3) Letter from Mr. Frank J. Miraglia (NRC) co Mr. J. A.

Tiernan (BC&E), dated December 19, 1986; Interim i Approval of ASME Code Update and Relief for Main [

Steam Piping Flaw at Calvert Cliffs Unit 1.

i (4) Letter from Mr. J. R. Lemons (BC&E) to Document Control Desk (NRC), dated February 5, 1987 transmitting LER ,

87 02 1

, (5) Letter from Mr. Ashok C. Thadani (NRC) to Mr. J. A. l Tiernan (BC&E), dated March 26, 1987; Final Approval of and Safety Evaluation concerning ASME Code Update and l Relief for Main Steam Piping Flaw at Calvert Cliffs i:

Unit 1 (6) Letter from Mr. Robert A. Capra (NRC) to Mr. J. A.

Tiernan (BC&E), dated March 11, 1988; Relief Extension for Main Steam Piping Flaw at Calvert Cliffs Unit 1 (TAC 66454)

(7) Letter f. Mr. W. J. Lippold (BC&E) to Document .

Control Desk (NRC), dated May 4, 1988; Main Steam Thin  !

Wall  !

(8) Letter from Mr. S. R. Cowne (BC&E) to Document Control Desk (NRC), dated June 6, 1988; Main Steam Thin Wall t

[

[

l i

L l

.- r v 4.,-.,. --.----_,-..,,--,,.n_,,. ,

. - --..,. ,- .-.,- - - - ,_=., - - , - - _ - - - , - - - - , - - , . . -