Discusses Response to Generic Ltr 88-17, Loss of Dhr. Development of Appropriate Tech Spec Changes for Reducing Cooling Flow Rate in Process.Changes Will Provide Increased Margin to Vortexing Conditions
ML20064A747
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 09/18/1990
From: Creel G
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-88-17, TAC-69730, TAC-69731, NUDOCS 9009280025
Download: ML20064A747 (2)


Text

3 y,

.L

'1 Q

gy

,9-BALTIMORE y

OAS AND O

E l. E C T R IC j

o CHAFtLES CENTER _e. P.O.- BOX 1475

n, L'

L

~ oconoc c cacco -

- Vect Passiotut Nucitan ratsov '

1

,f 000 aso aass

,4

{

September 18, 1990 E

C

.U. S. Nuclear Regulatory. Commission 6-

=. Washington, DC 20555 i

ATTENTION:

Document Control Desk 1

SUBJECT:

Calvert Cliffs Nuclear Power Plant

. Unit Nos.1 & 2; Docket Nos. 50-317 & $0-318 1Resnonse to Generic Letter 88-17 (TACs 69730 & 69731)

M l

REFERENCES:

-(a)L Generic Letter ' 88-17, Loss of Decay Heat Removal," dated L

. October 417( 1988 L

w (b)L 1.e'tter from.Mr. J. A. Tiernan -(BG&E) to. NRC - Document' Controli Desk, dated' January-3.1989, same subject

,J.

h (c)J Letter from Mr.' J. A.:..Tiernan2(BG&E) to NRC Document Control

' Desk, dated January 27, 1989, same subject i

li

.. Gentlemen:,

t.

/

Genericitetter 88-17 described : concerns and recommended actions forf operation -of the

};

Reactor v Coolant System (RCS) and Shutdown Cooling o(SDC) - System - during - reduced i

L, inventory conditions. 'In c response. to the Generic Letter, Baltimore Gas. and Electric

- (BGAE) CompanySimplemented the expeditious actions described in ' Reference (b) and is

=l l implementing ' programmatic enhancements as described in Reference (c). -The programmatic l

enhancements in Reference (c) indicated that BG&E would take - action to submit an j

amendment request. which -would reduce the minimum flow rates; allowed' by Technical LSpecifications in order l to reduce the likelihood of air ingestion into ; the SDC system i

as 3 a Tresult of vortexing. Our intent was to submit that license amendment ' request during April" 1990.

4 Baltimore Gas and ! Electric had previously incorporated reduced SDC flow requirements

~during mid-loop operations at Calvert Cliffs (see Amendment'Nos. 38 and 21 for Units 1-Land.' 2, respectively, from - 1979). Subsequent to the Generic Letter, BG&E' has m

N conducted ivortex ? testing and participated in a Combustion Engineering Owners Group I

-effort to' develop appropriate Technical Specification changes for reducing the shutdown.

cooling flow rate.LThe Owners Group report was received by BG&E in August 1990-and is currently under review for plant-specific implementation.

0 +"

49pn743eres y g,

-9009280025 900918 i'

PDR ADOCK 05000317

//O P

9 PDC

/

a.

I4

'.f DocWmelt C:ntrol Desk.

1 m

~ September-. 18,-1990 Page 2'

?

I.

,, :n b

Our license amendment request is~ now expected to be submitted during October i990.

J

. Since Calvert Cliffs has previously - incorporated reduced SDC ' flow ' requirements ' during mid-loopL operations : the proposed: changes will provide increased margin' to vortexing conditions and additional operational-flexibility.

Should - you ' have any questions regarding this matter, we will be pleased to discuss them s

with you.

Very truly yours j

/

\\'

f GCC/tRG/ dim cc:

D. A. Brune, Esquire J. E.

Silberg, Esquire R. A'. Capra, NRC.

D. G. Mcdonald, Jr., NRC

--T. T. Martin, NRC =,

L. E. Nicholson, NRC '

R. L McLean, DNR; i

H.

1

(..