__-

Cuc t.Es H. C3SE Baltimore Gas and Electric Company Vice President Calvert Cliffs Nuclear Power Plant Nuclear Energy 1650 Cdvert Cliffs Parkway Lusby, Maryland 20657 410 495-4455 t

May 18,1999 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calven Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Request for Additional Information Regarding Baltimore Gas and Electric Company Wind Tunnel Tests and Their Comparison with ARCON96 Comnutations

REFERENCE:

(a)

Letter from Mr. C.11. Cruse (BGE) to NRC Document Control Desk, dated March 19, 1999, Request for Additional Information Regarding Baltimore Gas and Electric Company Wind Tunnel Tests and Their Comparison with ARCON96 Computations As part of our desire to properly address General Design Criteria 19 regarding Control Room IIabitability, we forwarded you numerous documents regarding wind tunnel tests and their comparison with ARCON96 Computations (Reference a). You noted that four pages were missing from its Attachment (1), Wind Tunnel Modeling of Calven Cliffs Nuclear Power Plant - CPP Project 94-1040.

Since this document is quite lengthy, we are forwarding you pages C-30, C-31, C-114 and C-115. You also noted missing pages from the 1985 report " Wind Flows and Dispersion Conditions of Calvert Cliffs," which was part of its Attachment (4). We have a complete copy of the 1985 report and are forwarding it to you. Previously, we had only ponions ofit.

Should you have additional questions regarding this matter, we will be pleased to discuss them with you.

Very truly yours, 9905260034 990518

~

g PDR ADOCK 05000317 (g.__ i\\

}

P PDR _

CliC/JMO/ dim Attachments: (1) Wind Tunnel Modeling of Calven Cliffs Nuclear Power Plant - CPP Project 94-1040 (pages C-30, C-31, C-114 and C-115 only)

(2) Memo: Meteorology; Wind Flows and Dispersion Conditions of Calvert Cliffs

ij E

\\

1 Document Control Desk j

l.

. May 18,1999 l.

Page 2 -

l.

1 cc:

A. W. Dromerick, NRC (Without Attachments)

R. S. Fleishman, Esquire Resident Inspector,NRC J. E. Silberg, Esquire R. I. McLean, DNR l

S. S. Bajwa, NRC J. H. Walter, PSC l

H. J. Miller, NRC l

l l

l l

I i

l f

l i

(:.-

l

)

p-i i

ATTACHMENT (1) i l

l 1

i WIND TUNNEL MODELING OF CALVERT CLIFFS NUCLEAR POWER PLANT--

CPP PROJECT 94-1040 (PAGES C-30, C-31, C-114 AND C-115 ONLY) 1

)

l l

Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant Msy 18,1999

Cermak Peterka Petersen, Inc.

C-30 CPP Project 94-1040 FULL SCALE CONCENTRATION RESULTS Calvert Cliffs NPP Project: 1040 Run Nunber: 30C Wind Speeds Wind dir: 90 Scales 300 Site Anemometer Buildings: In Date:

07-12 94 Uref (m/s) 4.98 U (m/s) 2.87 2ref (m) 300 Z (m) 10.00 Source names H

D F

  1. of sources operating:

1 1

1 Stack height (m) 15.2 4.6 30.5 Emission Rate (g/s) 1.000 1.000 1.000 Loc c (1) C (2) C (3)

Description

( g/m') (#g/m8) (#g/m')

1 Control Room In #1

.9

.2 4.4 2 control Room In #2

.0

.0 5.3 3 Control Room out

.5

.1 4.1 4 Exhaust vent VU 54

.0

.0 2.3 5 Smoke Removal Fan

.2

.0 5.2 6 Control Room HVAC

.0

.0 6.9 7 Equip. Room Supply

.0

.1 6.2 8 Alternate Location

.0

.0 2.4 9 Alternate Location

.1

.0 4.4 10 Alternate Location

.0

.0 1.5 11 Alternate Location

.1

.2 2.1 12 Alternate Location

.0

.0 3.6 13 Alternate Location

.3

.1 1.0 14 Alternate Location

.0

.0

.0 15 Alternate Location

.0

.3

.8 16 Alternate Location

.0

.0

.0 17 Alternate Location 43.0 7.2 19.8 18 Alternate Location

.C

.0

.0 19 Alternate Location

.0

.0 131.8 20 Alternate Location 977.9 163.0 285.1 Maximums:

9 77.9 163.0 285.1 CPP#

r

Cermak Peterka Petersen, Inc.

C-31 CPP Project 94-1040 FULL SCALE CONCENTRATION RESULTS Calvert Cliffs NPP Projects 1040 Run Number 31C Wind Speeds Wind dir:

101.2 l

Scate:

300 Site Anemometer Buildings: In Date:

07 12-94 Uref (m/s) 4.98 U (m/s) 2.87 Zref (m) 300 2 (m) 10.00 i

Source names H

D F

1

  1. of sources operating:

1 1

1 Stack height (m) 15.2 4.6 30.5 Emission Rate (g/s) 1.000 1.000 1.000

)

Loc C (1)

C (2) C (3)

Description

(#g/m8) (pg/m8) (pg/m8) 1 Control Room in #1 5.9 5.9 19.2 2 Control Room In #2 7.9 7.1 30.6 3 control Room out 5.5 5.8 19.3 4 Exhaust Vent W-54 7.1 5.6 16.4 j

5 Smoke Removat Fan 5.9 5.3 14.6 6 Control Room HVAC 7.0 6.2 23.5 7 Equip. Room Supply 5.2 6.6 26.1

{

8 Alternate Location 6.4 5.8 18.3

)

l 9 Alternate Location 5.5 6.3 22.4 10 Alternate Location 7.0 8.0 37.9 s

11 Alternate Location 6.0 8.6 41.7 12 Alternate Location 6.8 8.1 42.4 13 Alternate Location 5.7 4.2 8.2 14 Alternate Location 6.5 4.2 9.7 15 Alternate Location 5.4 4.0 6.8 16 Alternate Location 7.4 15.3 195.3 17 Alternate Location 47.2 12.2 60.4 18 Alternate Location 7.4 5.2 14.2 19 Alternate Location 435.8 35.0 310.4 20 Alternate Location 1381.8 94.6 379.4 Maxinuns:

1381.8 94.6 379.4 l

9 CPPA

V Cermak Peterka Petersen, Inc.

C-114 CPP Project 94-1040 i

i l

I FULL SCALE CONCENTRATION RESULTS Calvert Cliffs NPP Projects 1040 Run Number 114B Wind Speeds Wind dir 337.5 i

Scales 300 Site Anemometer Buildings: In Date:

07-12-94 Uref (m/s) 7.48 U (m/s) 4.49 2ref (m) 300 Z (m) 10.00 Source names L

M

  1. of sources operating:

1 1

Stack height (m) 18.3 18.3 Emission Rate (g/s) 1.000 1.000 Loc C (1) C (2)

Description

(#g/m3) (pg/m')

1 Control Room In #1 548.0

.0 2 control Room In #2 509.2 56.9 3 control Room out 542.6 39.3 4 Exhaust vent VU 54 643.4

.0 5 Smoke Removal Fan 763.6

.0 6 Control Room HVAC 694.4 64.4

7. Equip. Room Supply 605.2

.0 8 Alternate Location 687.7 52.7 9 Alternate Location 588.8

.0 10 Alternate Location 482.9 69.4 11 Alternate Location 375.3 195.7 12 Alternate Location 470.9 55.2 13 Alternate Location

.0

.0 14 Alternate Location

.0

.0 15 Alternate Location 21.5

.0 16 Alternate Location 89.3 267.4 17 Alternate Location 47.8

.0 18 Alternate Location 73.3 5.4 19 Alternate Location 239.8 7.6 20 Alternate Location 169.0 9.3 Maxle ms:

763.6 267.4 I

CPPd

E 1

Cermak Peterka Petersen. Inc.

C-115 CPP Projec/ 94-1040 FULL SCALE CONCENTRATION RESULTS Calvert Cliffs NPP Projects 1040 Run Number: 115A Wind Speeds l

Wind dir 0

Scatet 300 Site Anemometer Buildings: In Date:

07 12 94 Uref (m/s) 5.22 U (m/s) 3.01 Zref (m) 300 Z (m) 10.00 Source names L

M

  1. of sources operating:

1 1

Stack height (m) 18.3 18.3 Emission Rate (g/s) 1.000 1.000 Loc C (1) C (2)

Descriptlon (pg/m8) (pg/m')

1 Control Room In #1 966.0 47.0 2 Control Room In #2 739.0 96.9 l

3 Control Room out 725.6 53.5 l

4 Exhaust Vent VU 54 1412.0 55.3 5 Emoke Removal Fan 994.0

.0 6 Control Room HVAC 816.1 55.3 7 Equip. Room Supply 647.8 57.1 8 Alternate Location 891.2 45.4 t

1 9 Alternate Location 686.1 61.5 l

10 Alternate Location 513.7 266.0 11 Alternate Location 336.7 614.7 12 Alternate Location 393.8 210.6 13 Alternate Location 317.8

.0 14 Alternate Location 2 75.0 12.1 15 Alternate Location 283.9

.0 16 Alternate Location 87.2 374.0 17 Alternate Location 82.8

.0 18 Alternate Location 420.2 26.0 19 Alternate Location 241.7 62.3 20 Atternate Location 153.0 27.1 Maximuns:

1412.0 614.7 l

l

/

~

l 1

CPE

ATTACHMENT (2) i MEMO: METEOROLOGY; WIND FLOWS AND DISPERSION CONDITIONS OF CALVERT CLIFFS 1

i Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant May 18,1999