ML20058G251
ML20058G251 | |
Person / Time | |
---|---|
Site: | Big Rock Point File:Consumers Energy icon.png |
Issue date: | 11/02/1990 |
From: | Beverly Clayton NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
To: | |
Shared Package | |
ML20058G247 | List: |
References | |
50-155-90-17, NUDOCS 9011130023 | |
Download: ML20058G251 (1) | |
Similar Documents at Big Rock Point | |
---|---|
Category:NOTICE OF VIOLATION OF A REGULATION
MONTHYEARML20202J8471998-02-14014 February 1998
[Table view]Notice of Violation from Insp on 971205-980202.Violation Noted:Chemical Decontamination Worker Working Under RWP B982035 in High Radiation Area for Approx 55 Minutes & Did Not Monitor Dosimetry Time IR 07100008/20120041997-12-17017 December 1997 Notice of Violation from Insp on 971008-1204.Violation Noted:On 971029,items Hanging from Spent Fuel Pool Rail Span 19 Had Combined Weight of 497 Pounds.Length of Time That Weight on Rail Exceeded Weight Restriction Not Determined ML20199J4571997-11-19019 November 1997 Notice of Violation from Insp on 961216-971107.Violations Noted:Certain Radiation Surveys Required by Station Procedure RP-29,not Completed.Also Certain Radiation Survey Records Required to Be Maintained,Not Accurate ML20211J7341997-10-0606 October 1997 Notice of Violation from Insp on 970902-05.Violation Noted: on 970902,maintenance Worker Preparing to Participate in Reactor Head Detensioning Operations Laid Down in Contaminated Area for Several Minutes ML20217J3391997-08-12012 August 1997 Notice of Violation from Insp on 970303-0428.Violation Noted:On 970202 Rj Flowers,Employee of Consumers Power Co, Did Not Exit High Radiation Area After Receiving Alarm on Electronic Dosimeter as Required ML20217K5521997-08-12012 August 1997 Notice of Violation from Insp on 970303-0428.Violations Noted:Licensee Failed to Properly Evaluate Potential Radiological Hazards Associated W/Transfer of Highly Contaminated Filters ML20151J7721997-07-22022 July 1997 Notice of Violation from Insp on 970430-0616.Violation Noted:Inspector Identified That on 960403 & 970502,seven & Five CRDs Respectively Were Left After Insertion Time Testing W/Insert Speeds Greater than 28 ML20140G8851997-06-10010 June 1997 Notice of Violation from Insp on 970313-0429.Violation Noted:Procedures Were Not Followed,In That Required Working Clearances & Protective Tagging Were Not Obtained by Workers Prior to Performing Work Activities ML20135D4431997-02-24024 February 1997 Notice of Violation from Insp on 961130-970117.Violation Noted:Use of Inappropriate Surveillance Procedure Causing Uncontrolled Leak & Inline Relief Valve Lifting Due to Failure to Remove Installed Blank Flange ML20134C9421997-01-29029 January 1997 Notice of Violation from Insp on 961019-1129.Violations noted:961108 Operators Closed EC Number 1 Loop Inlet Valve (MO-7062) Making Number 1 EC Loop Inoperable & Operability Test Number 2 EC Loop Outlet Valve Not Performed within 1 H ML20133C5111997-01-0202 January 1997 Notice of Violation from Insp on 961202-06.Violation Noted: High Radiation & Contaminated Areas Was Not Posted W/Signs Bearing Radiation Symbol ML20029E8381994-05-12012 May 1994 Notice of Violation from Insp on Stated Date.Violation Noted:On 940322,licensee Failed to Ensure That VTG-1A Was Open Before Resetting Ipr ML20059C1031993-12-21021 December 1993 Notice of Violation from Insp on 931020-1214.Violation Noted:Results of Static Votes Testing at Final Asleft Torque Switch Setting for MO-7053 Were Not Evaluated Prior to Return to Svc of Valve ML20059J9541993-11-0909 November 1993 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 for Violations from Insp on 930824- 0914.Violations Noted:Control Rod Withdrawal Interlocks Test Not Accomplished in Accordance W/Procedure TR-96/T7-29 ML20059G1861993-11-0101 November 1993 Notice of Violation from Insp on 931018-22.Violation Noted: Licensee Failed to Conduct 1991/1992 Requalification Program within Two Year Requirement ML20057A1271993-09-0808 September 1993 Notice of Violation from Insp on 930809-20.Violation Noted: High Pressure Trip Setpoint Periodically Exceeded Limit of Less than or Equal to 2.2 Psig W/No Resulting Orderly Shut Down Being Performed ML20045H1061993-07-12012 July 1993 Notice of Violation from Insp on 930621-25.One non-cited Violation Noted:Meter Not Calibrated from 1986 to 921210, Period Exceeding 18 Months IR 05000155/19920171993-04-23023 April 1993 Notice of Violation from Insp on 930217-0406.Violation Noted:Licensee Failed to Respond in Writing to Commission within Time Prescribed to Address Violation 50-155/92017-03 (DRP) ML20035D7251993-04-0808 April 1993 Notice of Violation from Insp on 921130-1204.Violation Noted:Radiation Protection Technician & Station Engineer Entered Recirculation Pump Room & Steam Drum Area W/O Taking Air Sample ML20126F9321992-12-24024 December 1992 Notice of Violation from Insp on Stated Dates.Violation: on 920214,radiation Protection Technician & Station Engineer Entered Recirculation Pump Room & Steam Drum Area W/O Taking Air Sample ML20024F9011990-12-17017 December 1990 Notice of Violation from Insp on 901016-1126.Violation Noted:Failure to Follow Maint Order 89-SPS-0039 by Replacing Circuit Breaker 52-2A14 Instead of Circuit Breaker 52-1A14 ML20024G0011990-12-14014 December 1990 Notice of Violation from Insp on 900925-28.Violations Noted: Failure to Conduct Suitable Inquiries on Employees Prior to Granting Unescorted Access to Sites ML20058G2511990-11-0202 November 1990 Notice of Violation from Insp on 900904-1015.Violation Noted:Three Individuals Failed to Initial Daily Entry Log Next to Name ML20059N0121990-09-28028 September 1990 Notice of Violation from Insp on 900723-27 & 0806-10. Violations Noted:Procedure 77-EPS-202-13 Issued on 770822, Required Implementation of Coincident Logic in Diesel Generator Overcurrent Trip Circuitry ML20034C4451990-03-0707 March 1990 Notice of Violation from Insp on 900101-0205.Violation Noted:On 900104,two Individuals Failed to Complete Required Entries on Radiation Work Permit Entry Log Sheet ML20245K0851989-08-14014 August 1989 Notice of Violation from Insp on 890710-0801.Violation Noted:On 890712,six Contaminated Items Stored in Normally Clean Areas within Plant Restricted Area,But Not Labelled W/ Contamination Levels,Contents & Date ML20245E6451989-08-0202 August 1989 Notice of Violation from Insp on 890618-0724.Violations Noted:Failure to Complete All Required Entries on Radiation Work Permit Entry Log Sheet & Tools,Not Listed on Log Sheet, Found on Reactor Bldg Crane (Tool Control Area) ML20154N4681988-09-22022 September 1988 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $187,500.Noncompliance Noted:Failure to Qualify Equipment Important to Safety by Appropriate Testing &/Or Analysis ML20154J7991988-09-16016 September 1988 Notice of Violation from Insp on 880711-0906.Violation Noted:Instruments Not Tested Using Detector Current Values Which Were Appropriate to Those Found at Facility Re Satisfactory Inservice Performance of wide-range Monitors ML20151T1961988-08-0505 August 1988 Notice of Violation from Insp on 880602-0718.Violation Noted:Failure to Inspect Complete Disassembly,Repair & Reassembly Process of Single Valve & to Perform Dimensional Check of Diaphragms or Comparison Between Diaphragms ML20196C3241988-06-27027 June 1988 Notice of Violation from Insp on 880523-27.Violation Noted: Maint Procedure MGP-14, Disassembly & Assembly of SMA-0 to SMA-4 Limitorques, Rev 3 & Prints Used for safety-related Valves Inappropriate to Circumstances ML20236U0541987-11-25025 November 1987 Notice of Violation from Insp on 870831-1117.Violation Noted:As of Sept 1987,licensee Had Failed to Correct Administrative Weaknesses Identified During March 1987 QA Surveillance of Inservice Testing Program ML20238D9161987-09-0404 September 1987 Notice of Violation from Insp on 870803-07.Violation Noted:On 870704 & 05,licensee Failed to Analyze Two Independent Samples & Verify Rate Calculations & Discharge Line Valving Prior to Initiating Planned Release ML20214N4071987-05-21021 May 1987 Notice of Violation from Insp on 870128-0423 ML20207J4411987-01-0505 January 1987 Notice of Violation from Insp on 861208-12 ML20214F8771986-11-17017 November 1986 Notice of Violation from Insp on 860711-0923 ML20212B7001986-08-0101 August 1986 Notice of Violation from Insp on 851209-860718 ML20207J3091986-07-18018 July 1986 Notice of Violation from Insp on 860409-0710 IR 05000730/20100311986-02-24024 February 1986 Notice of Violation from Insp on 850730-1031 ML20023C3011983-04-27027 April 1983 Notice of Violation from Insp on 830101-0304 & 14 ML20032D7211981-11-0606 November 1981 Notice of Violation from Insp on 810928-1002 ML20032E5241981-11-0505 November 1981 Notice of Violation from Insp on 811001.Noncompliance Noted: Radiation Level of Up to 300 Mr/Hr Was Measured on Undersurface of Transport Vehicle Containing Low Level Radwaste ML20032E5851981-11-0404 November 1981 Notice of Violation from Insp on 810921-25 ML20030B9981981-08-12012 August 1981 Notice of Violation from Insp on 810613-0710 ML20004E3231981-05-0505 May 1981 Notice of Violation from Insp on 810310-0409 ML19345G4291981-03-11011 March 1981 Notice of Violation from Insp on 810110-0209 ML19341B3581980-12-17017 December 1980 Notice of Violation from Insp on 801020-24 ML19351F2301980-12-0202 December 1980 Notice of Violation from Insp on 801103-06 ML19343C1811980-11-26026 November 1980 Notice of Violation from Insp on 801008-1107 ML20148L3301980-06-13013 June 1980 Notice of Violation from Health Physics Appraisal on 800303-14 1998-02-14 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000155/19990051999-09-30030 September 1999
[Table view]Insp Rept 50-155/99-05 on 990731-0921,site Insp & 990929 Public Meeting.No Violations Noted.Major Areas Inspected: Routine Decommissioning Insp Covered Aspects of Facility Mgt & Control & Decommissioning Support Activities IR 05000155/19990041999-08-12012 August 1999 Insp Rept 50-155/99-04 on 990609-0730.No Violations Noted. Major Areas Inspected:Aspects of Facility Mgt & Control, Decommissioning Support Activities Including Security, Spent Fuel Safety & Radiological Safety IR 05000155/19990031999-06-21021 June 1999 Insp Rept 50-155/99-03 on 990416-0608.No Violations Noted. Major Areas Inspected:Facility Mgt & Control,Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety IR 05000155/19990021999-04-26026 April 1999 Insp Rept 50-155/99-02 on 990226-0415.No Violations Noted. Major Areas Inspected:Aspects of Facility Mgt & Control, Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety IR 05000155/19990011999-03-19019 March 1999 Insp Rept 50-155/99-01 on 990113-0225.One non-cited Violation Noted.Major Areas Inspected:Aspects of Facility Mgt & Control,Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety IR 05000155/19980091999-01-15015 January 1999 Insp Rept 50-155/98-09 on 981201-990112.No Violations Noted. Major Areas Inspected:Licensee Management & Control, Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000155/19980081998-12-0303 December 1998 Insp Rept 50-155/98-08 on 980827-1130.No Violations Noted. Major Areas Inspected:Radiological Safety IR 05000155/19980071998-10-14014 October 1998 Insp Rept 50-155/98-07 on 980827-1007.No Violations Noted. Major Areas Inspected:Facility Mgt & Control,Physical Security,Spent Fuel Safety & Radiological Safety IR 05000155/19980061998-09-0303 September 1998 Insp Rept 50-155/98-06 on 980716-0826.No Violations Noted. Major Areas Inspected:Aspects of Licensee Mgt & Control, Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety ML20195C6211998-08-18018 August 1998 EN-98-059,informing Commission That Staff Intends to Exercise Broad Discretion Pursuant to Section VII.B.6 of Enforcement Policy & Not Issue NOV or Propose Civil Penalty for Severity Level II Violation Identified by Licensee IR 05000155/19980051998-07-24024 July 1998 Insp Rept 50-155/98-05 on 980528-0715.No Violations Noted. Major Areas Inspected:Licensee Mgt & Control,Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety IR 05000155/19980021998-04-21021 April 1998 Insp Rept 50-155/98-02 on 980203-0406.No Violations Noted. Major Areas Inspected:Licensee Mgt & Control,Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety IR 05000155/19970151998-02-14014 February 1998 Insp Rept 50-155/97-15 on 971205-980202.Violations Noted. Major Areas Inspected:Facility Management & Control, Decommissioning Support Activities,Spent Fuel Safety & Radiological Safety ML20202J8471998-02-14014 February 1998 Notice of Violation from Insp on 971205-980202.Violation Noted:Chemical Decontamination Worker Working Under RWP B982035 in High Radiation Area for Approx 55 Minutes & Did Not Monitor Dosimetry Time ML20199A2571997-12-30030 December 1997 EN-97-117:on 980105,informs Commission That Order Prohibiting Involvement in NRC-licensed Activities Issued to Dt Rich.Action Based on Investigation Conducted by Oi,Which Determined on 960721 & 0915,DT Rich Falsified Records ML20197E5901997-12-17017 December 1997 Insp Rept 50-155/97-13 on 971008-1204.Violations Noted. Major Areas Inspected:Major Aspects of Licensee Decommissioning Activities,Including Facility Mgt & Control, Decommissioning Support & Spent Fuel Safety Controls IR 07100008/20120041997-12-17017 December 1997 Notice of Violation from Insp on 971008-1204.Violation Noted:On 971029,items Hanging from Spent Fuel Pool Rail Span 19 Had Combined Weight of 497 Pounds.Length of Time That Weight on Rail Exceeded Weight Restriction Not Determined IR 05000155/19970101997-11-26026 November 1997 Insp Rept 50-155/97-10 on 970802-1007.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20199J4571997-11-19019 November 1997 Notice of Violation from Insp on 961216-971107.Violations Noted:Certain Radiation Surveys Required by Station Procedure RP-29,not Completed.Also Certain Radiation Survey Records Required to Be Maintained,Not Accurate IR 05000155/19970121997-10-17017 October 1997 Insp Rept 50-155/97-12 on 970812-1007.Violations Noted.Major Areas Inspected:Miscellaneous Security & Safeguards Issues IR 05000155/19970091997-10-0909 October 1997 Insp Rept 50-155/97-09 on 970617-0804.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering ML20211J7341997-10-0606 October 1997 Notice of Violation from Insp on 970902-05.Violation Noted: on 970902,maintenance Worker Preparing to Participate in Reactor Head Detensioning Operations Laid Down in Contaminated Area for Several Minutes ML20217K5521997-08-12012 August 1997 Notice of Violation from Insp on 970303-0428.Violations Noted:Licensee Failed to Properly Evaluate Potential Radiological Hazards Associated W/Transfer of Highly Contaminated Filters ML20217J3391997-08-12012 August 1997 Notice of Violation from Insp on 970303-0428.Violation Noted:On 970202 Rj Flowers,Employee of Consumers Power Co, Did Not Exit High Radiation Area After Receiving Alarm on Electronic Dosimeter as Required ML20151J7721997-07-22022 July 1997 Notice of Violation from Insp on 970430-0616.Violation Noted:Inspector Identified That on 960403 & 970502,seven & Five CRDs Respectively Were Left After Insertion Time Testing W/Insert Speeds Greater than 28 IR 05000155/19970081997-07-22022 July 1997 Insp Rept 50-155/97-08 on 970430-0616.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support PNO-III-97-055, on 970611,decision to Permanently Shut Down Plant Three Yrs Before Expiration of Operating License in Yr 2000.Capacity of 67 Megawatts & Future Needed Improvements Would Be Too Expensive.State of Mi Will Be Informed1997-06-11011 June 1997 PNO-III-97-055:on 970611,decision to Permanently Shut Down Plant Three Yrs Before Expiration of Operating License in Yr 2000.Capacity of 67 Megawatts & Future Needed Improvements Would Be Too Expensive.State of Mi Will Be Informed ML20140G8851997-06-10010 June 1997 Notice of Violation from Insp on 970313-0429.Violation Noted:Procedures Were Not Followed,In That Required Working Clearances & Protective Tagging Were Not Obtained by Workers Prior to Performing Work Activities ML20140G8931997-06-10010 June 1997 Insp Rept 50-155/97-04 on 970313-0429.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000155/19970071997-06-0606 June 1997 Insp Rept 50-155/97-07 on 970426-0501.No Violations Noted. Major Areas Inspected:Licensee Fire Protection Program IR 05000155/19970061997-05-23023 May 1997 Insp Rept 50-155/97-06 on 970428-0502.No Violations Noted. Major Areas Inspected:Review of Vehicles Barrier Sys,Audits & Self Assessment,Testing,Maint,Security Contingency Capability & Protected Area Detection ML20141J9951997-05-19019 May 1997 Insp Rept 50-155/97-05 on 970303-0428.Violations Noted. Major Areas Inspected:Event in Which Workers Entered Power Block While Reactor at 9% Power Level Prior to Performance of Adequate Evaluation of Area Radiological Conditions IR 05000155/19970031997-05-13013 May 1997 Insp Rept 50-155/97-03 on 970331-0404.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program PNO-III-97-012, on 970224,licensee Notified NRC Resident Inspector Ofc That Loose Radioactive Surface Contamination Spread Throughout Turbine Bldg,During Transfer of Radwaste Processing Filters from Temporary Storage Barrel1997-02-26026 February 1997 PNO-III-97-012:on 970224,licensee Notified NRC Resident Inspector Ofc That Loose Radioactive Surface Contamination Spread Throughout Turbine Bldg,During Transfer of Radwaste Processing Filters from Temporary Storage Barrel IR 05000155/19960121997-02-24024 February 1997 Insp Rept 50-155/96-12 on 961130-970117.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20135D4431997-02-24024 February 1997 Notice of Violation from Insp on 961130-970117.Violation Noted:Use of Inappropriate Surveillance Procedure Causing Uncontrolled Leak & Inline Relief Valve Lifting Due to Failure to Remove Installed Blank Flange IR 05000155/19960011997-01-29029 January 1997 Insp Rept 50-155/96-01 on 961019-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20134C9421997-01-29029 January 1997 Notice of Violation from Insp on 961019-1129.Violations noted:961108 Operators Closed EC Number 1 Loop Inlet Valve (MO-7062) Making Number 1 EC Loop Inoperable & Operability Test Number 2 EC Loop Outlet Valve Not Performed within 1 H ML20133C5111997-01-0202 January 1997 Notice of Violation from Insp on 961202-06.Violation Noted: High Radiation & Contaminated Areas Was Not Posted W/Signs Bearing Radiation Symbol ML20133C5231997-01-0202 January 1997 Insp Rept 50-155/96-11 on 961202-06.Violations Noted.Major Areas Inspected:Radiological Protection & Chemistry Controls,Status of Rp&C Facilities & Equipment IR 05000155/19960071996-12-0606 December 1996 Insp Rept 50-155/96-07 on 960909-12.No Violations Noted. Major Areas Inspected:Emergency Plan & Procedures IR 05000155/19960061996-10-28028 October 1996 Insp Rept 50-155/96-06 on 960727-0906.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support PNO-III-96-064, on 961023,shutdown for Evaluation of Environ Qualification Data Made.Licensee Performed Preliminary Assessment of Effect of Higher than Anticipated Temp Profile on safety-related Electrical Equipment Located1996-10-24024 October 1996 PNO-III-96-064:on 961023,shutdown for Evaluation of Environ Qualification Data Made.Licensee Performed Preliminary Assessment of Effect of Higher than Anticipated Temp Profile on safety-related Electrical Equipment Located IR 05000155/19960051996-09-20020 September 1996 Insp Rept 50-155/96-05 on 960608-0726.No Violations Noted. Continued Attention Needed on Maint Work on Plant TS Required Equipment.Major Areas Inspected:Engineering,Maint, & Plant Support PNO-III-94-039, on 940517,two Persons,Russian Visitor & Interpreter Were Killed in Traffic Accident Near Charlevoix,Mi.Cause of Accident Under Investigation1994-05-18018 May 1994 PNO-III-94-039:on 940517,two Persons,Russian Visitor & Interpreter Were Killed in Traffic Accident Near Charlevoix,Mi.Cause of Accident Under Investigation ML20029E8381994-05-12012 May 1994 Notice of Violation from Insp on Stated Date.Violation Noted:On 940322,licensee Failed to Ensure That VTG-1A Was Open Before Resetting Ipr IR 05000155/19940061994-05-12012 May 1994 Insp Rept 50-155/94-06 on 940321-25.No Violations Noted. Major Areas Inspected:Operational Status of Emergency Preparedness Program IR 05000155/19940071994-05-12012 May 1994 Insp Rept 50-155/94-07 on Stated Date.Violations Noted.Major Areas Inspected:Operational Safety Verification,Engineered Safety Feature Sys Walkdown,Maint & Surveillance,Engineering & Plant Support Activities IR 05000155/19930191993-12-21021 December 1993 Insp Rept 50-155/93-19 on 931020-1214.Violations Noted.Major Areas Inspected:Operational Safety Verification,Engineered Safety Feature Sys Walkdowns & Maint & Surveillance Activities ML20059C1031993-12-21021 December 1993 Notice of Violation from Insp on 931020-1214.Violation Noted:Results of Static Votes Testing at Final Asleft Torque Switch Setting for MO-7053 Were Not Evaluated Prior to Return to Svc of Valve 1999-09-30 |
Text
NOTICE OF VIOLATION Consumers Power Company Docket No. 50-155 As a result of the inspection conducted September 4 through October. 15,.1990, and in accordance with 10 CFR Part 2, Appendix C - General Statement of Policy and Procedure for NRC Enforcement Actions (1990), the follcwing violation was
. identified:
Section 6.8.1 of the Technical Specifications states in part, " Written procedures shall be established, implemented and maintained for all structures, systems, components and 1,afety ections defined in the Big Rock Point Quality List."
Section 5.3.1.c of Administrative Procedure Volume 1, Procedure 5.5 " Radiation Work Permit" Rev. 3, dated June 17, 1990, states in part, " The worker shall review the Radiation Work Permit package and/or be briefed on radiation protection requirements and survey data, then initial the Daily Entry Log next to his name to indicate they understand and will comply with the stated requirements."
Contrary to the above, on September 18, 1990, three individuals failed to initial the Daily Entry Log (Form BRP052) next to their name. This is the same problem discovered during the 1989 refueling and maintenance outage that resulted in a Severity Level V violation documented in Inspection Report (155/89013(DRP)) and a Severity Level IV violation documented in Inspection Report (155/90002(DRP)).
This is a Severity Level IV violation (Supplement IV).
Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or and the results achieved; (2) g for each violation (1) corrective action taken explanation in reply, includin corrective action to be taken to avoid further violations; and (3) the date when full compliance will be achieved.
Consideration may be given to extending your response time for good cause shown.
h NOV c 21HO Mted Brent Clayton, Chief Reactor Projects Branch 2 Obbk $h,1j8[,
PDC i